12
GB
The airow can be continuously adjusted by turning the power regulator (Fig. 10).
MIN: Reduced suction for applications which generate a low level of dust.
MAX: Maximum suction performance for use in applications which generate a high level of dust.
4. Filter Cleaning Operation
IMPORTANT: Only perform the lter cleaning operation when the cartridge lter is installed.
If the suction performance diminishes, you can improve the suction power with the help of the lter
cleaning system.
1) Position the end of the suction hose nozzle into the channel located within the lter cleaner
button.
2) Move the on/off switch to the “I” position.
3) Turn the power regulator to the MAX position.
4) Press the lter cleaning button down and hold it down for 3-4 seconds (Fig. 11).
5) Repeat the process two more times.
5. Wet & Dry Vacuum Operation
WARNING! ENSURE YOU READ, UNDERSTAND AND APPLY SECTION
ENTITLED ‘SAFETY INFORMATION’.
1) Verify that the correct lter is installed and the container latches are secured.
2) Secure the locking end of the hose into the vacuum suction port.
3) Push the desired accessories onto the hose nozzle. The air ow regulation allows you to
change vacuum cleaner suction. For best cleaning results, fully close the air ow regulation
(Fig. 12).
4) Plug the power cord into a power outlet.
5) Turn on the motor by assigning the switch to the “I” ON position.
6) Once you have completed vacuuming, switch to the “O” OFF position and unplug the power
cord from the power outlet.
For Dry Vacuuming:
WARNING: BEFORE INSTALLING, REMOVING OR CLEANING THE VACUUM
CLEANER FILTER, ENSURE THAT THE POWER CORD IS UNPLUGGED AND
SWITCHED OFF.
1) To prepare your vacuum cleaner for dry vacuuming, install the cartridge lter over the lter
cage. Carefully push lter until it sits ush forming a tight seal. Tighten the lter retainer lock
clockwise to secure against the internal lter cage (Fig. 13).
3) Switch the vacuum cleaner to position II, as described in Switching ON/OFF. The moment you
switch on the power tool, the vacuum cleaner will also switch on. Once the electrical appliance
has been switched off, the vacuum cleaner switches off following a time lapse
(around 5 seconds) to allow the suction tube to be emptied.
3. Power Regulator
2. Power Tool Take-Off Operation (Fig. 9)
WARNING: Always check the maximum wattage compatibility of the power tool take
off socket against the desired power tool before connecting to prevent overloading.
1) Connect the power cable of your power tool to the power take-off socket.
2) If applicable, connect the vacuum suction hose to the dust extractor connector on your tool with
the supplied adaptor.