Quick Guide
Vaisala VaiNet Wireless Access Point
AP10

PUBLISHED BY
Vaisala Oyj
Vanha Nurmijärventie 21, FI-01670 Vantaa, Finland
P.O. Box 26, FI-00421 Helsinki, Finland
+358 9 8949 1
Visit our Internet pages at www.vaisala.com.
© Vaisala 2020
No part of this document may be
reproduced, published or publicly
displayed in any form or by any means,
electronic or mechanical (including
photocopying), nor may its contents be
modified, translated, adapted, sold or
disclosed to a third party without prior
written permission of the copyright holder.
Translated documents and translated
portions of multilingual documents are
based on the original English versions. In
ambiguous cases, the English versions are
applicable, not the translations.
The contents of this document are subject
to change without prior notice.
Local rules and regulations may vary and
they shall take precedence over the
information contained in this document.
Vaisala makes no representations on this
document’s compliance with the local
rules and regulations applicable at any
given time, and hereby disclaims any and
all responsibilities related thereto.
This document does not create any legally
binding obligations for Vaisala towards
customers or end users. All legally binding
obligations and agreements are included
exclusively in the applicable supply
contract or the General Conditions of Sale
and General Conditions of Service of
Vaisala.
This product contains software developed
by Vaisala or third parties. Use of the
software is governed by license terms and
conditions included in the applicable
supply contract or, in the absence of
separate license terms and conditions, by
the General License Conditions of Vaisala
Group.
This product may contain open source
software (OSS) components. In the event
this product contains OSS components,
then such OSS is governed by the terms
and conditions of the applicable OSS
licenses, and you are bound by the terms
and conditions of such licenses in
connection with your use and distribution
of the OSS in this product. Applicable OSS
licenses are included in the product itself
or provided to you on any other applicable
media, depending on each individual
product and the product items delivered
to you.

Table of contents
English.............................................................................................................................................5
Deutsch......................................................................................................................................... 15
Français........................................................................................................................................ 25
Español.........................................................................................................................................35
Português....................................................................................................................................45
日本語...............................................................................................................55
中文.................................................................................................................. 65
3

4 M211821EN-E

Setting up AP10
2
3
1
1Touchscreen.
2Ethernet cable. Use a shielded cable to
meet the rated EMC performance of
the device.
3Cable from DC power supply.
• AP10 requires a network connection to your viewLinc Enterprise Server and a
Network Time Protocol (NTP) server. AP10 can also use its default NTP servers
if Internet is accessible from the network.
• It is usually easiest to configure the access point before mounting it.
1. Connect the Ethernet cable to Ethernet port of AP10. If possible, connect to the same
network where the viewLinc Enterprise Server is, so that you can verify the connection
when doing the setup.
2. If the Ethernet cable does not provide power, connect the DC power supply:
a. Connect the plug to the power supply connector of AP10. Make sure the plug is
oriented correctly and goes in all the way. Rotate the plug to lock it in, otherwise it
will not stay reliably connected.
b. The power supply comes with multiple adapters for wall sockets. Connect the adapter
you need, and plug in the power supply to a wall socket.
5
ENGLISH

3. A setup wizard starts when AP10 is first powered up. Use the touch interface to complete
the wizard:
a. Select a language for the touchscreen display.
b. Configure the network settings so that AP10 can join the network:
• Select Dynamic IP address (DHCP) if you are connecting the access point to a
network that assigns network configuration settings automatically.
• Select Static IP address to configure network settings manually. Using the
information supplied by your IT administrator, enter the IP address, Subnet mask,
and Default gateway.
DHCP is the most common way to assign network settings. Do not use a
static address unless your IT administrator has instructed you to do so.
c. Configure the Network Time Protocol (NTP) servers that the access point will attempt
to synchronize with. If you have a local NTP server in the network, replace one of the
default NTP server hostnames with its IP address or hostname.
d. Select a VaiNet channel (1 ... 8). Each access point in range of each other must have a
unique channel assigned to it.
e. Enter the IP address or hostname of the viewLinc Enterprise Server. Leave the TCP
port at default 12600 unless you know it has been changed.
f. Enable Installation Mode to start connecting data loggers to your system.
g. Wait for the display to change to the home screen.
4. If the setup wizard has already been completed previously, press the symbol to open
the Settings screen and check all of the settings listed in step 3. There are also some
optional settings for display and LED, and for locking the touchscreen using a password.
The default password is ap123456.
6 M211821EN-E

5. After configuring all of the settings, verify the status of the access point from the home
screen. The access point should be connected to the network and the viewLinc Enterprise
Server, and the Installation Mode should be enabled so that new data loggers can be
connected.
The access point will not turn on its radio if it does not have
accurate time. This means that data loggers cannot connect to the access
point until it has synchronized its time with a Network Time Protocol (NTP)
server. To accomplish this, the access point must have a network
connection to one of the configured NTP servers. Connecting to the default
NTP servers requires Internet access, and network firewall must allow the
access point to connect to UDP port 123.
An NTP connection error continues to be shown while AP10 is
synchronizing time with the listed NTP servers. It may take up to 15 minutes
for it to disappear even when the NTP servers are reachable. Wait patiently.
CAUTION!
7
ENGLISH

Mounting AP10
B
A
Figure 1 AP10 mounting methods
AMounting with cable ties (2 pcs)
BMounting with screws (4 pcs)
mm
[in]
116 [4.57]
124 [4.88]
Ø3.50
[0.11]
Figure 2 AP10 screw mounting dimensions
1. Attach AP10 to its mounting location using the most suitable mounting option. Ensure the
unit is securely fixed if you are mounting it higher than 2 m (approx. 6 ft) or in a location
where it would pose a hazard if dropped.
8 M211821EN-E

2. Point the antenna up or down for best wireless performance.
3. Connect the Ethernet cable.
4. If the Ethernet cable does not provide power, connect the DC power supply:
a. Connect the plug to the power supply connector of AP10. Make sure the plug is
oriented correctly and goes in all the way.
b. Rotate the power plug slightly to lock it to the connector.
c. Connect the power supply to the wall socket.
5. Secure the power supply so it does not fall or hang on its cable.
6. Wait for the access point to start up. Verify from the touchscreen that the access point has
an IP address, and is connected to viewLinc. Make sure installation mode is still enabled if
you want to connect new data loggers.
For troubleshooting instructions, see AP10 User Guide (M211860EN) available
at www.vaisala.com/ap10.
Accessing the web interface
Touchscreen interface may be hard to access after AP10 has been installed. AP10 also has a
web interface that you can use to remotely view access point status and configure its settings.
1. Verify the IP address of the access point from the touchscreen interface.
2. Open a web browser.
3. In the address field of the web browser, enter https:// and the IP address of AP10. For
example: https://192.168.10.47
4. The default user interface language is English. If you want to use another language for this
session, select it from the drop-down menu.
5. Enter the login information:
•User name: apadmin
•Password: ap123456 (default)
6. Select Log in to access the interface.
9
ENGLISH

Overview of AP10 Access Point
Vaisala VaiNet Access Point AP10 is a wireless access point that collects data from VaiNet
wireless data loggers and transfers it to the viewLinc Enterprise Server using a wired Ethernet
connection. AP10 implements Vaisala's proprietary VaiNet protocol. It can connect up to 32
RFL100 Data Loggers to the Vaisala viewLinc Monitoring System. The wireless connection
operates on 868 MHz, 915 MHz, or 920 MHz frequency band depending on the model. For
more information on viewLinc system installation, see the viewLinc Setup Guide and viewLinc
User Guide for your viewLinc Enterprise Server version.
viewLinc
Enterprise Server
AP10
Access Point
RFL100
Data Loggers
VaiNet wireless
>100 m (328 ft) range
NTP Server
Wired
network
Figure 3 AP10 in the viewLinc Monitoring System
AP10 can be powered from the Ethernet connector using Power over Ethernet (PoE) or from
the power supply connector using the included AC/DC adapter. If both power sources are
connected, the AC/DC adapter is utilized to power the device. AP10 is IP22 rated, and is
suitable for indoor industrial applications.
AP10 has two user interfaces:
• Touch interface on the front panel. Use this interface to set up the device during
installation and to locally check the connection status.
• Web interface via the Ethernet connection. This interface provides advanced
configuration features and can be accessed remotely.
AP10 installation location and range
In a typical indoor space, the wireless range of AP10 is at least 100 m (328 ft). In an open space
with line-of-sight and no interfering structures, the range can be over 500 m (1640 ft). Up to 8
access points can be placed within range of each other, even side-by-side, as long as they each
have their own VaiNet channel.
Walls and ceilings are good locations for AP10. Line of sight is not required. If possible, place
AP10 in the same floor as the data loggers. Point the antenna up or down for best wireless
performance.
Avoid placing AP10 close to large metal surfaces, as they may reduce the range of the radio
signal.
10 M211821EN-E

Data transfer in a VaiNet network
VaiNet protocol and VaiNet devices are designed for power-ecient operation. To save energy,
VaiNet network transfers data at set intervals, which may be apparent to the user as longer
data transfer times before the data is available in the viewLinc Enterprise Server.
Intermittent radio connections
Access points take turns communicating in a two-minute cycle, and connected data loggers
send their measurement data to their connected access point every 4 minutes. This introduces
the following scenarios:
• Data loggers that are not currently connected (new devices, or devices that have fallen
out of radio contact) scan for available access points for a complete cycle before they can
decide what is the optimal access point for them. Connection attempts typically take at
least a couple of minutes. Additionally, some joining scenarios may take multiple
attempts. For example, when filling a single access point up to its full capacity of 32 data
loggers, it may take an hour for the last data logger to successfully connect to the access
point.
• Access points request missing data and issue management commands to data loggers
within their communication window. Transferring a full month's worth of measurement
data from 32 data loggers using 1 access point takes several hours.
Data logger scanning interval
Scanning for available access points consumes power. To prevent repeated scanning from
draining their batteries, RFL100 data loggers shut down their radio temporarily if they cannot
connect to an access point. They will resume scanning after a waiting interval that gets
progressively longer if they keep failing to find an access point. The maximum interval is 8
hours and 30 minutes.
This means that when access points become available after an outage, it may take several
hours for data loggers to discover them. This is why you should always keep your access points
powered up, and why you should start your network installation by installing the viewLinc
Enterprise Server and access points first.
You can manually wake up the radio of an RFL100 data logger by pressing its Info
button. The button is located next to the service port under the silicone plug.
More information
For more information on AP10 Access Point, see AP10 User Guide (M211860EN) available at
www.vaisala.com/ap10.
11
ENGLISH

AP10 parts
1
2
3
4
5
Figure 4 Front
1Antenna. Can be rotated and tilted.
2Screw holes for mounting (4 pcs),
Ø 3.2 mm
3Ventilation hole (do not cover)
4Touchscreen
5Status LED:
Green Normal operation
Blue Installation mode active
Red Error - check status
1 2 3 4 5
Figure 5 Connector panel
1Power supply connector
(10 ... 30 VDC)
2Service port (micro-USB)
3USB port for hardware expansion
(USB type A)
4Reset button. Push to restart, push
and hold to revert AP10 to factory
settings.
5RJ-45 Ethernet port. Can be powered
by Power over Ethernet (PoE).
1
22
3
Figure 6 Rear
1Product label
2Holes for mounting with tie wraps
3Housing screws (do not remove)
12 M211821EN-E

Technical support
Contact Vaisala technical support at helpdesk@vaisala.com. Provide at least the
following supporting information as applicable:
• Product name, model, and serial number
• Software/Firmware version
• Name and location of the installation site
• Name and contact information of a technical person who can provide further
information on the problem
For more information, see www.vaisala.com/support.
Warranty
For standard warranty terms and conditions, see www.vaisala.com/warranty.
Please observe that any such warranty may not be valid in case of damage due to normal wear
and tear, exceptional operating conditions, negligent handling or installation, or unauthorized
modifications. Please see the applicable supply contract or Conditions of Sale for details of the
warranty for each product.
Recycling
Recycle all applicable material.
Follow the statutory regulations for disposing of the product and packaging.
13
ENGLISH


Einrichten des AP10
2
3
1
1Touchscreen.
2Ethernet-Kabel. Verwenden Sie ein
abgeschirmtes Kabel, damit das Gerät
die EMV-Nennwerte erreicht.
3DC-Netzteil.
• Das AP10 benötigt eine Netzwerkverbindung zu viewLinc Enterprise Server
und zu einem NTP (Network Time Protocol)-Server. Das AP10 kann auch den
NTP-Standardserver verwenden, wenn über das Netzwerk auf das Internet
zugegrien werden kann.
• Normalerweise sollte der Access Point vor dem Mounten konfiguriert werden.
1. Schließen Sie das Ethernet-Kabel an den Ethernet-Anschluss des AP10 an. Schließen Sie
das Gerät nach Möglichkeit an das Netzwerk mit viewLinc Enterprise Server an, damit Sie
während des Setups die Verbindung verifizieren können.
2. Falls über das Ethernet-Kabel keine Stromversorgung möglich ist, schließen Sie das DC-
Netzteil an:
a. Schließen Sie den Stecker an den Netzteilanschluss des AP10 an. Achten Sie darauf,
dass der Stecker richtig ausgerichtet und vollständig in die Buchse eingeführt ist.
Drehen Sie den Stecker, um ihn zu verriegeln, da die Verbindung andernfalls nicht
zuverlässig ist.
b. Das Netzteil ist mit mehreren Steckdosenadaptern ausgestattet. Schließen Sie den
benötigten Adapter an und stecken Sie das Stromversorgungsgerät in eine Steckdose.
15
DEUTSCH

3. Der Setup-Assistent wird gestartet, wenn das AP10 erstmals eingeschaltet wird. Schließen
Sie den Assistenten auf dem Touchscreen ab:
a. Wählen Sie eine Sprache für die Touchscreenanzeige aus.
b. Konfigurieren Sie die Netzwerkeinstellungen, damit das AP10 eine Verbindung zum
Netzwerk herstellen kann:
• Wählen Sie Dynamische IP-Adresse (DHCP), wenn Sie den Access Point mit
einem Netzwerk verbinden, in dem die Netzwerkkonfigurationseinstellungen
automatisch zugewiesen werden.
• Wählen Sie Statische IP-Adresse, um die Netzwerkeinstellungen manuell zu
konfigurieren. Geben Sie unter Verwendung der Daten vom IT-Administrator IP-
Adresse, Subnetzmaske und Standardgateway ein.
DHCP ist die gebräuchlichste Methode zum Zuweisen von
Netzwerkeinstellungen. Verwenden Sie keine statische Adresse, sofern
dies nicht vom IT-Administrator angeordnet wurde.
c. Konfigurieren Sie die NTP-Server, mit denen sich der Access Point synchronisieren
soll. Wenn ein lokaler NTP-Server im Netzwerk vorhanden ist, ersetzen Sie einen
Hostnamen der standardmäßigen NTP-Server durch dessen IP-Adresse oder
Hostnamen.
d. Wählen Sie VaiNet-Kanal (1 ... 8). Wenn sich mehrere Access Points im selben Bereich
befinden, muss jedem einzelnen ein einzigartiger Kanal zugewiesen sein.
e. Geben Sie die IP-Adresse oder den Hostnamen des viewLinc Enterprise Servers ein.
Lassen Sie den Standardwert 12600 für TCP-Port unverändert, sofern dieser nicht an
anderer Stelle geändert wurde.
f. Aktivieren Sie Installationsmodus, damit Datenlogger sich mit dem System verbinden
können.
g. Warten Sie, bis die Anzeige zum Startbildschirm wechselt.
4. Wenn der Setup-Assistent bereits zuvor verwendet wurde, drücken Sie auf das Symbol
, um den Bildschirm Einstellungen zu önen. Prüfen Sie alle Einstellungen, die in
Schritt 3 aufgelistet sind. Es gibt auch einige optionale Einstellungen für Display und LED
sowie zum Sperren des Touchscreens mit einem Kennwort. Das Standardkennwort lautet
ap123456.
16 M211821EN-E

5. Prüfen Sie nach dem Konfigurieren aller Einstellungen den Status des Access Point auf
dem Startbildschirm. Der Access Point muss mit dem Netzwerk und viewLinc Enterprise
Server verbunden und Installationsmodus muss aktiviert sein, damit Verbindungen zu
neuen Datenloggern hergestellt werden können.
Der Access Point aktiviert die Funkverbindung nicht, wenn die
Zeiteinstellung nicht genau ist. Dies bedeutet, dass Datenlogger erst eine
Verbindung zum Access Point herstellen können, nachdem dieser seine Zeit
mit einem NTP-Server (Network Time Protocol) synchronisiert hat. Dazu
muss der Access Point über eine Netzwerkverbindung zu einem der
konfigurierten NTP-Server verfügen. Für die Verbindung zu NTP-
Standardservern ist ein Internetzugang erforderlich und die
Netzwerkfirewall muss dem Access Point Verbindungen zum UDP-Port 123
gestatten.
Während das AP10 die Uhrzeit mit den aufgelisteten NTP-Servern
synchronisiert, wird weiter ein NTP-Verbindungsfehler gemeldet. Es kann
bis zu 15 Minuten dauern, bis die Fehleranzeige verschwunden ist, auch
wenn die NTP-Server erreichbar sind. Warten Sie.
ACHTUNG
17
DEUTSCH

Montieren des AP10
B
A
Abbildung 7 Befestigungsarten für das AP10
AMontage mit Kabelbindern (2 Stück)
BMontage mit Schrauben (4 Stück)
mm
116
124
Ø 3,50
Abbildung 8 Maße für die Befestigung des AP10 mit Schrauben
1. Bringen Sie das AP10 mit der am besten geeigneten Befestigungsart an der gewünschten
Stelle an. Stellen Sie sicher, dass die Einheit fest angebracht ist, wenn sie in einer Höhe von
mehr als 2 m oder an einer Stelle angebracht wird, an der sie ein Sicherheitsrisiko
darstellen würde, wenn sie herunterfiele.
18 M211821EN-E

2. Richten Sie die Antenne für die optimale Drahtlosverbindung nach oben oder unten aus.
3. Schließen Sie das Ethernet-Kabel an.
4. Falls über das Ethernet-Kabel keine Stromversorgung möglich ist, schließen Sie das DC-
Netzteil an:
a. Schließen Sie den Stecker an den Netzteilanschluss des AP10 an. Achten Sie darauf,
dass der Stecker richtig ausgerichtet ist und sich vollständig in den Anschluss drücken
lässt.
b. Drehen Sie den Stecker leicht, um in am Anschluss zu befestigen.
c. Stecken Sie das Netzteil in die Steckdose ein.
5. Befestigen Sie das Netzteil so, dass es nicht herunterfallen kann oder am Kabel hängt.
6. Warten Sie, bis der Access Point startet. Prüfen Sie auf dem Touchscreen, ob der Access
Point eine IP-Adresse hat und mit viewLinc verbunden ist. Der Installationsmodus muss
weiterhin aktiviert sein, wenn Verbindungen zu neuen Datenloggern hergestellt werden
sollen.
Anweisungen zur Fehlerbeseitigung siehe AP10 User Guide (M211860EN),
verfügbar unter www.vaisala.com/ap10.
Zugri auf die Weboberfläche
Der Zugri auf die lokale Touchscreen-Schnittstelle ist nach der Installation des AP10
möglicherweise schwierig. Der AP10 verfügt auch über eine Weboberfläche mit der Sie den
Status des Access Point einsehen und seine Einstellungen konfigurieren können.
1. Überprüfen Sie die IP-Adresse des Access Point über die Touchscreen-Schnittstelle.
2. Önen Sie einen Webbrowser.
3. Geben Sie in das Adressfeld des Browsers https:// und die IP-Adresse des AP10 ein.
Beispiel: https://192.168.10.47
4. Die Standardsprache der Benutzeroberfläche ist Englisch. Wenn Sie eine andere Sprache
für diese Sitzung verwenden möchten, wählen Sie sie im Dropdownmenü aus.
5. Geben Sie die Anmeldedaten ein:
•Benutzername: apadmin
•Passwort: ap123456 (standardmäßig)
6. Wählen Sie Anmelden, um auf die Schnittstelle zuzugreifen.
19
DEUTSCH

Übersicht zum AP10 Access Point
Der Vaisala VaiNet AP10 Access Point ist ein drahtloser Access Point, der Daten von VaiNet
Drahtlos-Datenloggern erfasst und diese über eine Ethernet-Verbindung an viewLinc
Enterprise Server übermittelt. Das AP10 verwendet das VaiNet Protokoll von Vaisala. Er kann
bis zu 32 RFL100 Datenlogger mit dem Vaisala viewLinc Monitoring System verbinden. Die
Funkverbindung arbeitet je nach Modell im Frequenzband 868 MHz, 915 MHz oder 920 MHz.
Weitere Informationen zur Installation des viewLinc Systems siehe viewLinc Setup Guide und
viewLinc User Guide für die jeweilige viewLinc Enterprise Server Version.
viewLinc
Enterprise Server
AP10
Access Point
RFL100
Datenlogger
VaiNet WLAN
Reichweite > 100 m (328 ft)
NTP-Server
Verkabeltes
Netzwerk
Abbildung 9 AP10 im Vaisala viewLinc Monitoring System
Das AP10 kann über Ethernet (PoE) oder über das Netzteil einschließlich AC/DC-Adapter mit
Strom versorgt werden. Wenn beide Stromquellen angeschlossen sind, wird der AC/DC-
Adapter zur Versorgung des Geräts verwendet. Der AP10 entspricht der Schutzart IP22 und ist
für industrielle Innenanwendungen ausgelegt.
Der AP10 verfügt über zwei Benutzeroberflächen:
• Touchscreen-Schnittstelle auf der Vorderseite. Diese Schnittstelle dient zur Einrichtung
des Geräts während der Installation und zur lokalen Überprüfung des Verbindungsstatus.
•Weboberfläche über die Ethernet-Verbindung. Diese Schnittstelle bietet erweiterte
Konfigurationsfunktionen und ermöglicht den Remotezugri.
Installationsstandort und -bereich des AP10
In einer typischen Innenumgebung beträgt die Reichweite des AP10 mindestens 100 m. In
einer oenen Umgebung mit direkter Sichtverbindung und ohne abschirmende Strukturen
kann die Reichweite mehr als 500 m (1640 Fuß) betragen. Bis zu 8 Access Points können in
Reichweite voneinander platziert werden, auch nebeneinander, sofern sie jeweils über einen
eigenen VaiNet-Kanal verfügen.
Der AP10 sollte idealerweise an Wänden oder Decken montiert werden. Eine direkte
Sichtverbindung ist nicht erforderlich. Platzieren Sie den AP10 nach Möglichkeit auf der
gleichen Etage wie die Datenlogger. Richten Sie die Antenne für die optimale
Drahtlosverbindung nach oben oder unten aus.
Vermeiden Sie es, das AP10 in der Nähe von großen Metallflächen zu platzieren, da hierdurch