Value VES-50B User manual

OPERATING MANUAL
www.worldvalue.cn
Refrigerant Recover
/Charge Scale

CONTENT
1. UNPACKING INSPECTION 3
2. SAFETY GUIDE……………………………………………3
3. TECHNICAL PARAMETER…………………………………4
4. LCD DISPLAY………………………………………………4
5. OPERATING MANUAL……………………………………5
FUNCTION SET 5
B/L SET………………………………………………………………………6
SCALE MODE………………………………………………………………6
CLEAR SET…………………………………………………………………6
CHARGE MODE……………………………………………………………6
RECOVER MODE…………………………………………………………8
REPEAT MODE……………………………………………………………10
6. MAINTENANCE……………………………………………10
………………………………
……………………………………………………………
Dear User:
Thank you for choosing Product. For best result and
right way to use it, please read this operating manual carefully
before using, and especially “Safety Guide”. We suggest that
you’d better keep this manual with the product or a place where
you can easily find for later reference.
VES-50B/100B
2
1
VES-50B/100B

1. UNPACKING INSPECTION 3. TECHNICAL PARAMETER
34
Unit Indicator
Company Logo Scale Overload
Indicator
Battery Level
Indicator
Charge Mode
Indicator
Recover Mode
Indicator
Main Numeric Display
Alarm
Indicator
VES-50B/100B VES-50B/100B
2. SAFETY GUIDE
Model
Weighing range
Resolution
Accuracy
Display
Power
Working
Environment
Platform Size
Weight
Anti-collision
VES-50B
50Kg/110Lb/1764oz
2g/0.01Lb/0.1oz
VES-100B
100Kg/220Lb/3528oz
5g/0.01Lb/0.2oz
0.05%
LCD(7 segment)
-℃ ℃(1 F~104°F)
≤75%RH
10 ~40 4°
237×237mm/ 9 1/3 ×9 1/3" "
6.2Kg
YES
Inlet/Outlet Port
9V DC & AC(110V~240V)
1/4"SAE
4. LCD DISPLAY
Part description Qty
Operating Manual 1
Carrying Case 1
Scale (fixed scale pan) 1
Backup Battery 1
Power Cord
Hook 1
1
Open the package case and please check the following parts to see
if any missing or damaged. If so, please contact your dealer immediately.
2.1 Check the scale before. Please do not use it if any part missing or
damaged.
2.2 Please do not weight items that are over the maximum capacity of
the scale. This could damage the scale.
2.3 Please try to place the item in the middle of the scale pan and do
not shake, never let any items (include the helix line) contact with
the scale, otherwise will influence the precision.
2.4 Please do not storage or use the scale at a place where is high
temperature, high humidity, explosive, flammable or strong
electromagnetic fields.
2.5 Please do not change the internal circuit of electronic scale.
2.6 Please do not pull the helix line, this could damage the scale.
2.7 Please replace the battery when battery alarm on.
2.8 Before use, please confirm whether the power is for single-phase
AC power use, otherwise it will damage the scale.
2.9 Cover the cap on inlet/outlet port after each use.
2.10 Turn the scale off after each use. If the unit is to be stored or not used
for long time, take the battery out of the electronic scale. The scale
turns off automatically after 30 minutes without pressing any buttons.

5. OPERATING MANUAL
5.1 FUNCTION SET
Press “Function” key, switch to oz .
Press “Function” key again, switch to Lb.
5.2 B/L SET
According to different needs, press “B/L” key the scale can turn B/L
(backlight) on or off. The color of the B/L is blue. The scale will not set
backlight as automatically. It will turns B/L off automatically after 30s
without pressing any buttons.
56
Kg
OZ
Lb
5.4 CLEAR SET
1. Press “CLEAR” key to cancel all function and back to SCALE MODE;
2. Press “ENTER” key to exit CLEAR MODE and display actual weight.
1. Make sure all connections
are correct and tight (refer
to following illustration):
VES-50B/100B VES-50B/100B
There are three weight units: Kg(kilogram)、oz(ounce)、Lb(pound).
Pressing “Function” key to scroll among kg, oz and lb. The scale will
set weight units as kg (kilogram) automatically.
5.3 SCALE MODE
The first weight will be more than1Kg(include 1Kg), and after that
the weight will display accurately as the resolution in the technical
parameter form.
5.5 CHARGE MODE
This function allows the user
to quickly and conveniently
charge a system in a minimal
amount of time. Simply turns
on the CHARGE MODE and
enter the weight (minimum
50g) to be charged.
CHARGESYSTEM
Air-conditioning
System
Tank
Power Supply

78
Caution:
a.
previous operation, then press “CHARGE” key, the previous screen will appear.
b. If you want to finish earlier during charge mode, press “CLEAR” key to stop.
If you press a wrong key during charge mode, press “ENTER” key to cancel the
5.6 RECOVER MODE
with a recovery/recycle machine component of a system.
The scale is not only a stand-alone scale but also can be compared
1. Make sure all connections are correct and tight (refer to following
illustration):
2. Turn the scale on.
3. Place refrigerant tank on scale. Wait for the reading to settle out.
e.g. The refrigerant tank is 12 Kg, the following screen will appear:
VES-50B/100B VES-50B/100B
Kg
Kg
Kg
6. If the scale is not connected to the AC power, the solenoid valve will
not work. The scale’s buzzer will alarm when charging nearly finish
(refrigerant ≤0.05 Kg). when the charge is completed, stop the charge
system manually. Press the “Enter” key exit to screen, the scale will
display the gross weight of refrigerant tank.
2. Turn the scale on.
3. Place refrigerant tank on scale. Wait for the reading to settle out.
e.g. The refrigerant tank is 12 Kg, the following screen will appear:
4. Press “Charge” key, the Charging Indicator will appear, and enter the
weight to be charged, then press “Enter” key. The solenoid valve will
open and the refrigerant will start to transfer.
e.g. The weight to be charged is 1 Kg, press “Charge”、“1”、 “Enter”
step by step.
5. When the entered amount of refrigerant has been transferred, the
solenoid valve will shut off automatically and the scale will display
the gross weight of refrigerant tank.
Power Supply
Air-conditioning
System
RECOVERYSYSTEM
Tank

910
VES-50B/100B VES-50B/100B
Kg
Kg
4. Press “Recover” key, the Recovering Indicator will appear, and enter
the weight to be recovered, then press “Enter” key. The solenoid valve
will open and the refrigerant will start to transfer.
e.g. The weight to be recovered is 1.5 Kg, press “Charge”、 “1”、“·”、
“5” 、“Enter” step by step.
Kg
6. If the scale is not connected to the AC power, the solenoid valve will
not work. The scale’s buzzer will alarm when recovering nearly finish
Caution:
a. If you press a wrong key during recover mode, press “ENTER” key to cancel the
previous operation, then press “RECOVER” key ,the previous screen will appear.
b. If you want to finish earlier during recover mode, press “CLEAR” key to stop.
c. If the entered recover weight is more than the gross weight of tank, the scale
will display “ERROR”, please re-enter the recover weight.
d. It is very dangerous if the recovering weight is more than 80% capacity of the
refrigerant tank.
The “Repeat” key is used to repeat the previously entered charge
/recover weight. After the first charge/recover cycle is complete, press
the “Repeat” key, it will start to charge/recover the same quantity as
last time.
5.7 REPEAT MODE
Caution: If there is a mistake or system is down, please press
“POWER” key to shutdown and wait for three seconds,
then press “POWER” key to restart.
1. Clean the surface of scale can only use a damp cloth and a little mild
detergent. Do not use chemical solvents.
2. Turn the scale off after each use. Take the battery out for storage.
3. Do not use or store the scale in a place of humidity, high temperature,
explosive, inflammable or strong magnetic field.
4. For overhaul and repair of the machine, ask an appointed VALUE
distributor or contact with VALUE company directly. It will be out of
warranty if the product disassembled by unauthorized individual.
5. Before each using please check the solenoid valve inlet whether
there is any visible admixture. If yes, please clip out the metal filter
to clean then put it back again.
6.MAINTENANCE
(refrigerant ≤0.05 Kg). when the recover is completed, stop the recover
system manually. Press the “Enter” key exit to screen, the scale will
display the gross weight of refrigerant tank.
5. When the entered amount of refrigerant has been transferred, the
solenoid valve will shut off automatically and the scale will display
the gross weight of refrigerant tank.
Other manuals for VES-50B
1
This manual suits for next models
1
Table of contents
Other Value Scale manuals