Vario 400 Series User manual

VI 424 610
Stainless steel frame
Width 15" (38 cm)
Installation accessories
In combination of several Vario
cooktops or VL 414 downdraft,
connecting strips must be used.
Choose respective VA 420 strip from
one of the below, depending on type
of installation.
VA 420 010
Connection strip for surface-mount
installation without appliance cover.
VA 420 011
Connection strip for surface-mount
installation with appliance cover.
VA 420 000
Connection strip for flush installation
without appliance cover.
VA 420 001
Connection strip for flush installation
with appliance cover.
VA 440 010
Stainless steel cover with mounting
strip
VA 450 400
Stainless steel adjustment strip, width
15". Necessary accessory in a combi-
nation of 15" Varios with at least one
appliance cover to compensate for the
appliance depth.
Optional accessories
GP 900 001
Stainless steel frying pan
Non-stick cooking, for ø 6"
cooking zone.
GP 900 003
Stainless steel frying pan
Non-stick coating, for ø 8"
cooking zone.
Vario 400 series induction cooktop
VI 424
– 2 cooking zones with Power boost
function
– Total output 3,600 W
– Solid stainless steel control knobs
– Precision-crafted ⅛-inch stainless
steel frame
– For surface-mount installation with
a visible edge or for flush
installation
– Can be perfectly combined with
other Vario 400 series products
Cooking zones
One ø 8 ¼" induction cooking zone
(2,200 W, 3,300 W with Power boost).
One ø 5 ⅞" induction cooking zone
(1,400 W, 1,800 W with Power boost).
Operation
Control knobs with illuminated
ring, cooking zone and output level
markings.
Electronic control in 12 output levels.
Features
Cooking zone marking.
Power boost function for each cooking
zone (only one zone at a time can be
operated with booster function)
Pan detection.
Short-term timer.
Safety
Individual residual heat indication.
Safety shut-off.
Planning notes
Depending on the type of installation —
surface-/ or flush-mounted, with or
without cover — the specific location of
the control knob positions may vary.
When using the appliance cover
VA 440 or adjustment strip VA450
additional space for cut-out depth
needs to be considered.
In a combination of Vario cooktops
with at least one appliance cover, the
adjustment strip VA450 is required.
In a combination of several Vario 400
series cooktops a connection strip
must be used.
Depending on the type of installation —
surface-/ or flush-mounted, with or
without cover — the respective VA 420
connecting strip must be used.
For flush installation the edge height
in the cut-out needs to be at least ½"
and for surface-mount ⅜". Ensure a
continuous cut surface of 90°.
The weight capacity and stability,
especially in case of thin countertops,
must be supported using suitable
substructures. Take the appliance
weight and additional loads into
account.
Flush installation is possible in
countertops made of stone, synthetics
or solid wood. Heat resistance and
watertight sealing of the edges must
be observed. For other materials,
please consult with your countertop
manufacturer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
Do not use discontinuous lining.
The joint width may vary due to size
tolerances of the combinations and of
the countertop cut-out.
If installing several Vario products in
individual cut-outs allow for a minimum
distance of 2" between the cooktops.
Operates with magnetic (induction)
iron pots and pans only. For an optimal
heat distribution, the use of sandwich
bottom cookware is recommended.
Immersion depth 2 ⅝" – 2 ¾"
depending on type of installation.
Built-in control panel can be integrated
in the bottom cabinet at drawer level.
Front panel thickness ⅝" – 1".
The adjacent drawing “Installation of
the control knobs” must be observed
if the panel is more than 1" thick (there
must be a recess at the rear for proper
control module installation).
Appliance clicks into place when
inserted into the countertop from
above.
Please read additional planning notes
on pages 82 – 87.
Rating
Total rating: 3.6 kW.
Total Amps: 16 A.
208/220–240 V / 60 Hz
Total connected load 3.6 kW.
Plan for a 37" connecting cable
without plug (hard wire required).

Numbers indicated
inside parenthesis ( ) = mm
* with appliance cover or adjustment strip.
See separate planning notes.
** 39/16" (90) in the area of the wire connection (rear, right).
R
1
/8" (3)
90°
39" (1.0 m)
min. 4
1
/8" (105)
max. 6
3
/8" (162)
min. 2" (50)
dia. 2
1
/8" (60)
dia. 1
3
/8" (35)
**2
5
/
8" (67)
14
15
/16"
(380)
20
1
/2
" (520)
*21
1
/
16
" (*535)
19
3
/8"
±1
/16" (492
±2)
*20
1
/
4
"
+1
/
16
" (*515
+2
)
1
/8" (3)
14
3
/16"
±1
/16"
(360
±2
)
3
9
/16" (90)
8
15
/16"
(227)
2
13
/16"
(72)
11"
(280)
3"
(76)
1
3
/8" (35)
*
with appliance cover or adjustment strip.
See separate planning notes.
**
3
11
/
16
" (93) in the area of the wire connection (rear, right).
90°
1
/
8
"
(3.5
-0.5
)
R
1
/
8
" (3)
R
3
/
16
"
(5
+1
)
39" (1.0 m)
min. 1
3
/
8
" (35)
min. 4
1
/
4
" (109)
max. 6
1
/
2
" (166)
min. 2"
(50)
dia. 2
1
/
8
" (60)
dia. 1
3
/
8
" (35)
14
15
/
16
"
(380)
20
1
/
2
" (520)
*21
1
/
16
" (*535)
19
3
/
8
"
±1
/
16
" (492
±2
)
*20
1
/
4
"
+1
/
16
" (*515
+2
)
20
11
/
16
"
+1
/
16
" (526
+2
)
*21
1
/
4
"
+1
/
16
" (*541
+2
)
14
3
/
16
"
±1
/
16
"
(360
±2
)
15
3
/
16
"
+1
/
16
"
(386
+2
)
**2
3
/
4
" (70)
1
/
8
"
(3)
3
9
/
16
"
(90)
8
15
/
16
"
(227)
2
13
/
16
"
(72)
11"
(280)
3"
(76)
Surface-mount Installation Flush-mount Installation
Installation of the control knob; surface-mount installation
Control knob installation, surface-mounted installation
ø 13/8" (35) ø 13/8" (35)
min. 3/16" (5)
min. 3/16" (5)
4
1
/8"-6
3
/8"
(105-162)
4
1
/8"-6
3
/8"
(105-162)
5
/8"-1"
(16-26)
D =1" (26)
D >1" (26)
3
1
/8"x12
3
/16"
(80x310)
Control knob installation, flush-mounted installation
ø 13/8" (35) ø 13/8" (35)
min. 3/16" (5)
min. 3/16" (5)
4
1
/4"-6
1
/2"
(109-166)
4
1
/4"-6
1
/2"
(109-166)
5
/8"-1"
(16-26)
D =1" (26)
D
>
1" (26)
3
1
/8"x12
3
/16"
(80x310)
Installation of the control knob; flush-mount installation
fill with
silicone
Longitudinal section
1/8" (3.5
-0.5
)
143/16"±1/16"
(360
±2)
1415/16"
(380)
153/16"+1/16"
(386
+2)
1/2"
(13)
1/2"
(13)
1/8"
(3+1)
1/8"
(3+1)
Longitudinal section
When installing with appliance cover or adjustment strip, pay attention to
the deeper cut-out and the front and rear groove width.
Cross-section
fill with
silicone
1/8" (3.5
-0.5
)
193/8"±1/16"
(492
±2)
2011/16"+1/16"
(526
+2)
11/16"
(17)
11/16"
(17)
1/8"
(3+1)
1/8"
(3+1)
20
1
/2"
(520)
Cross-section
* with appliance cover or adjustment strip
View from above
R 3/16"
(R 5+1)
R1/8"
(R 3)
143/16"±1/16"
(360
±2)
153/16"+1/16"
(386
+2)
2011/16"+1/16"
(526
+2)
*211/4"+1/16"
(*541+2)193/8"±1/16"
(492
±2)
*201/4"+1/16"
(*515+2)
(observe the front and rear asymmetrical support, see separate notes
"Installation with appliance cover/spacer batten").
View from above
* with appliance cover or adjustment strip (observe front and rear asymmetrical
assembly. See separate notes “assembly with appliance cover/adjustment strip”
on page 87).
* with appliance cover or adjustment strip. See separate planning notes on page 87.
** 3 ⁹⁄₁₆"(90) in the area of the wire connection (rear, right).
* with appliance cover or adjustment strip. See separate planning notes on page 87.
** 3 ¹¹⁄₁₆"(93) in the area of the wire connection (rear, right).
This manual suits for next models
2
Other Vario Cooktop manuals