Vemer memo RF User manual

INTERRUTTORE ORARIO/ASTRONOMICO
DIGITALE CON BUS RF Manuale d’Uso
memo RF
Digital time/astronomical switch
with RF BUS: User Manual
PDF


English
- 1 -
User manual memo RF
Index
■Technical features page 3
■Safety warnings page 4
■Battery management page 4
■Dimensions page 5
■Wiring diagrams page 5
■Display and keyboard description page 6
■Initial operation page 7
■Start page (or main) page 8
■Menu description page 11
■Settings menu page 12
Language setting menu page 13
Date setting menu page 14
Time setting menu page 15
Daylight saving time (DST)/winter time (CET)
change setting menu page 16
Astronomical coordinates setting menu page 18
Random switchings setting menu page 20
Protection PIN setting menu page 21
■Manual operation menu page 22
■Program menu page 24
Program menu: new page 29
Program menu: new daily timed page 30
Program menu: new weekly timed page 31
Program menu: new holiday timed page 32
Program menu: new astro night page 34
Program menu: new astro daily page 38
Program menu: new astro weekly page 39
Program menu: new astro holiday page 40
Program menu: check page 42
Program menu: modify page 44
Program menu: copy page 46
Program menu: delete page 47
■Bluetooth menu page 48
■Bus RF menu page 50
Simple network configuration with one or
more remote actuators page 52
Connection test page 53
■Hour couter menu page 54
■Reset menu page 56
■Firmware menu page 58
■Error signals page 59
■Reference standards page 60

English
- 2 -
User manual memo RF
USER MANUAL
memo RF is a digital electronic clock for managing electrical users over time. Allows hourly programming (periodicity: daily or weekly) or
astronomical. memo RF does not have on-board relays but is able to drive up to 8 different channels (relays) made by radio frequency remote
actuators (available as accessories), connected through the RF BUS. Each channel can be associated with a different programming (hourly or
astronomical).
The bluetooth interface allows pairing with mobile devices (smartphone or tablet). Thanks to the free app that can be downloaded from the
App Store and Google Play stores, you can make programming and settings directly on your smartphone, and then transfer all the data to the
device. The reverse procedure is also possible, ie copying the programming of a clock on your mobile device.
The backup battery allows you to keep the settings even in the event of a black-out and can be replaced through the cover on the back of the
device.
Code Model Description
VE790200 memo RF Time / astronomical switch with Bluetooth and RF bus for controlling radio frequency remote actuators
VE736500 RX.16A Remote flush-mounted actuator for radiofrequency devices with 1 relay 16A / 250V
VE471900 RX1-8A P Remote wall-mounted actuator for radiofrequency devices with 1 relay 8A / 250V
VE015400 RX1-8A Remote modular actuator for radiofrequency devices with 1 relay 8A / 250V
VN943700 RX4-8A Remote modular actuator for radiofrequency devices with 4 relays 8A / 250V
VE443800 RX7-5A Remote modular actuator for radiofrequency devices with 7 relay 5A / 250V
VE017000 RX.ANT Radiofrequency receiver antenna

English
- 3 -
User manual memo RF
TECHNICAL FEATURES
• Power supply: 230 Vac (-15% ÷ +10%) 50/60 Hz
• Power consumption: 3,5 VA (1 W)
• Lithium backup battery: 3 V CR2032 type (replaceable)
• Output: 8 channels available (no relays on board), realized
physically by as many relays, trough the connection via Bus RF
of additional modules (see product table on page 2).
• Terminal block for connection:
- power supply (terminal blocks 1-2)
- input Rx.Ant antenna (terminal blocks 7-8) available as
accessory
• Maximum cable section: 2,5 mm2
• Display LCD with backlight (active with AC power supply)
• RF communication interface with Vemer protocol:
- Operating frequency band: 433.92MHz
- Maximum transmitted power: 10 dBm
• Bluetooth BLE 4.2 communication interface
(active with mains power supply):
- Operating frequency band: 2400-2483,5 MHz
- Maximum transmitted radiofrequency power: 4 dBm
• Storable programs: 120 events (divisible on 8 channels)
• Operating temperature: -20 ÷ 50°C
• Operating humidity: 20 ÷ 90% not condensing
• Storage temperature: -20 ÷ 70°C
• Conteiner: 2 DIN modules
• Protection degree: IP20
• Insulation: reinforced between accessible parts (front)
and all the other terminals

English
- 4 -
User manual memo RF
SAFETY WARNINGS
nDuring product installation and operation it is necessary
to observe the following instructions:
1) The instrument must be installed by a qualified person,
strictly in observance of the connection diagrams shown
in this manual.
2) After installation inaccessibility to the terminals without
using dedicated tools must be guaranteed.
3) Before accessing the connection terminals, make sure
that the leads are not live.
4) Do not connect or feed the instrument if any part of it is
damaged.
5) The product must be installed and activated in com-
pliance with current electric systems standards.
6) Do not use the instrument for anything other than the
indicated purpose.
7) In the electrical system upstream of the instrument
must be installed a protection device against the
overcurrents
8) The product can be used in environments with
overvoltage category III and pollution degree 2,
according to the Standard IEC 60730-1
BATTERY MANAGEMENT
When the battery is close to empty, on the first line of the display
appears . In this case, the battery must be replaced as
soon as possible. Use only batteries of CR2032.
To replace the battery:
- disconnect the mains
- remove the battery slot cover, turning it anti-clockwise
and replace the battery
- remount the cover, turning it clockwise
- connect the power supply
Warning: do not use metal objects (such as screwdrivers) to remove
the battery because this may cause the power reserve to be canceled,
resulting in a loss of date and time.
Warning: in order not to lose the programming steps and carried out
settings, it is necessary to ensure that the time for the battery repla-
cement doesn’t exceed 60 seconds (in absence of power by means).
It is necessary to remove the batteries
before the instrument is scrapped.
In case of replacement, dispose of the batteries in the
appropriate places separate waste collection containers.

English
- 5 -
User manual memo RF
WIRING DIAGRAMSDIMENSIONS
35
87
65

English
- 6 -
User manual memo RF
DISPLAY AND KEYBOARD DESCRIPTION
General indications
Time indication
Channel status
blocked switchings
active random switchings
active holiday program
active pulse program
active manual program
Channels status indication (CHANNEL) / days of the week (DAY)
configured channel (in off status)
configured channel (in on status)
Turn on the display,
access the menu,
ESC (one level back)
Increase / decrease value,
scroll through the menu items
Confirm selection
Hardware reset

English
- 7 -
User manual memo RF
INITIAL OPERATION
• Once out of the package, memo RF is off: press the key and
wait a moment before activating the display
• The set language is Italian. To change it, press the key for
at least 3 seconds. Choose among: Italian, English, Spanish,
French or German and confirm with
• Make connections following the diagrams on page 5 of this
manual
• Power memo RF: the backlight turns on permanently. Power
possible additional connected modules
• The presence of the backup battery allows the memo RF to
have updated date and time.
To make the other settings follow the following steps:
Date - format: DD/MM/YY
- 1st day of the week: Monday
Astronomical coordinates - country: Italy
- city: Agrigento
- latitude: North (37° 19’ 12”)
- longitude: East (13° 34’ 12”)
Daylight Saving time (DST)
change: active
- start of daylight saving time (DST):
last Sunday of March at 02:00
o’clock
- end of daylight saving time (DST):
last Sunday of October at 03:00
o’clock
Time correction: - sunrise: +0:00
- sunset: +0:00
Time zone: +1:00 UTC
Random switchings: - minimum: 1 minute
- maximum: 5 minutes
PIN protection: disabled (---)
Bluetooth: active
Password Bluetooth: 123456

English
- 8 -
User manual memo RF
START PAGE (or main)
• Press the key:
to access the menu of the memo RF
to display the calculated sunrise and sunset times***
*** The displayed times take into account possible entered values
of correction (see page 18)
if the display shows means that the calculated sunrise
time is after the sunset time if the display show
means that the calculated sunrise time is before 00:00 or that
the calculated sunset is at 23:59
Information messages
- day of the week
- product identification code and serial number
- battery status (only if discharged)
- **
* See page 6. In this case there isn’t any configured channel
(no number turned on)
** Only if memo RF is not powered by mains.
In this condition the backlight is not active.
NOTE: Bluetooth interface is active only when memo RF displays
the start page (main) and only if it’s mains power supplied.
Therefore, to transfer programs from and to the time witch it
is necessary to respect these conditions.
information messages
data
hour
channels status*
date

English
- 9 -
User manual memo RF
Access the store of your device, install and start the free app memo – Vemer.
Memo
Add memo
NEARBY DEVICES
Connect to a new memo
VE790200–18E97132
CE:61:CB:15:C6:DB
1 2 3
456
789
0
ABC DEF
GHI JKL MNO
PRQS TUV WXYZ
Connect to a new memo
NEARBY DEVICES
Bluetooth pairing request
Enter PIN to pair with VE790200–18E97132
(Try 0000 or 1234).
PIN
Usually 0000 or 1234
Cancel OK
Memo
BT RF
LAST UPDATE
DEVICE
18-05-2022 09:48:09
BT RF
VE790200–18E97132
bt
RF
Device detail
LAST UPDATE 18-05-2022 09:48:09
SINCHRONISE
RELAY OUTPUTS
SETTINGS
PARAMETERS
PROGRAMS
VE790200 – 18E97132

English
- 10 -
User manual memo RF
At the start the app displays the list of the associated memo devices.
To associate a new device, press the symbol “+” in the upper right corner.
All the Bluetooth devices detected nearby are displayed: select the device to be associated from the list.
Note: each device is identified by the product code (for example VE790200) and by the serial number (for example 00000020).
These informations can be viewed from the main page of the memo RF.
Warning: make sure that the memo RF is mains powered and that the display shows the main page (initial).
Otherwise the Bluetooth interface is not active and the device is not visible.
Enter the password to associate the memo RF with your device (if not modified the password is 123456).
After successfully completing the procedure, the memo RF is added in the list of the associated devices.
Select the memo RF on which you want to act from the list of the associated devices.
Note: communication between the app and the memo RF is point-to-point. This means that,
even in the presence of multiple memo RF, the app can communicate with one only at a time.
The memo RF currently connected to the app displays the symbol * immediately after the serial number.
The app displays the initial page of the selected memo RF. From this page you can:
a. Create new programs that will then be copied to the memo RF
b. Change the settings of the memo RF
c. View the parameters and associate an alias (name that identifies the time switch, such as “memo RF Belluno”)
to the memo RF
d. Manually control the relay output/s and activate the random switching function

English
- 11 -
User manual memo RF
MENU DESCRIPTION
“Bus RF” menu allows you to configure
the radiofrequency remote actuator modules
“Hour counter” menu allows you to check the
operation hours (relay on) of the loads connected
to each channel (relay).
“Reset” menu allows you to reset settings,
programmed settings, operating hour counter.
“Ver FW” menu allows you to check the firmware
version installed on the device.
“Settings” menu allows you to change: language, date, time, daylight saving time (DST),
astronomical coordinates, minimum and maximum duration of the interval between
two switchings with random program, PIN for keyboard lock.
“Manual” menu allows you to switch or to lock the status of any
channel and to activate the function of random or cycle switchings.
“Programming” menu allows you to set a new
program or to check, to copy, to modify or to
delete a set program.
“Bluetooth” menu allows
you to configure the Bluetooth
communication.

English
- 12 -
User manual memo RF
SETTINGS MENU
“Settings” menu allows you to view and eventually to modify
the general operation settings of memo RF, such as:
language
date
time
automatic daylight saving time (DST) change
position (astronomical coordinates)
interval duration between two random switchings
keys protection by PIN

English
- 13 -
User manual memo RF
Language setting menu
Available languages:
Italian, English, Spanish, French, German.
Quick access: from the main page it’s possible to access the language
setting by pressing the key for at least 3 seconds.

English
- 14 -
User manual memo RF
Date setting menu
Parameters modification
1Possible date formats: day-month-year ( ), year-month-day ( ),
month-day-year ( ).
2Choose, by convention, the first day of the week. In Italy, for example, the first day of the week
is Monday, in the UK it’s Sunday.
3Enter the date: day, month, year.
Parameters
modification
1
2
3

English
- 15 -
User manual memo RF
Time setting menu
1
Parameters modification
1Set the time: hours, minutes.
2Set the time zone.
Range: -14:00 ÷ +14:00 at 15 minutes steps.
For Italy set +1:00.
Parameters
modification

English
- 16 -
User manual memo RF
Daylight saving time (DST)/winter time (CET) change setting menu
Daylight saving time (DST) / winter time (CET) change and vice versa can occur in an automatic way. In this case, memo RF:
- increases by an hour in the passage from winter time (CET) to daylight saving time (DST)
- decreases by an hour in the passage from daylight saving time (DST) to winter time (CET)
For every change it’s necessary to specify:
the week of the month during
which the time change occurs
(first, second, third, fourth, last)
the day of the week
(Monday: 1, Tuesday: 2, ...)
the month hour and minutes
In Italy,for example, daylight saving time (DST) begins the last ( ) Sunday ( ) of March ( ) at o’clock and ends the last
( ) Sunday ( ) of October ( ) at o’clock.

English
- 17 -
User manual memo RF
2
Parameters modification
1Choose to activate ( ) or to disable ( ) the automatic time change.
2Set date and time of the winter time (CET)-daylight saving time (DST) change.
3Set date and time of the daylight saving time (DST)-winter time (CET) change.
Parameters
modification

English
- 18 -
User manual memo RF
Astronomical coordinates setting menu
The setting of the geographical coordinates of the installation place allows memo RF to calculate, for each day of the year, sunrise and sunset
times.
To simplify the procedure, in the memo RF are stored the coordinates of the locations listed below; if your location is among them you can
select it from the menu , otherwise it’s necessary to enter the coordinates of latitude and longitude (menu ).
Note: the display on point shows “---------” if the coordinates have been entered manually.
In the memo RF the locations of all the provinces of Italy and the main English, French, German, Spanish and Finnish cities are stored.
The correction of sunrise and sunset times is useful for applications that require the turning on of lights in particular localities. It’s possible, in
fact, that the presence of disturbing elements, such as the mountains, can influence actual times of sunrise and sunset, making it necessary
to advance or delay of a few minutes the calculated times.
The twilight is the time interval before sunrise, or after sunset, characterized by the permanence of the light due to the spread by the
atmosphere of the sun light. During these time intervals it’s possible to distinguish clearly objects and conduct outdoor activities without
using additional lighting. Therefore, in some applications it is more interesting to take as times of switching on and off the twilight (civil) in
place of sunrise and sunset. With memo RF it’s possible to choose to turn on/off the loads depending on the times of sunrise and
sunset or the civil twilight. The calculated time correction also applies to the times of twilight. To view the calculated switching on time
(sunset) and switching off time (sunrise), from the main page press the key (see page 8).
Table of contents
Other Vemer Switch manuals

Vemer
Vemer memo BT1 GPS User manual

Vemer
Vemer CR1DIN User manual

Vemer
Vemer memo AST1 User manual

Vemer
Vemer memo User manual

Vemer
Vemer DUET-D User manual

Vemer
Vemer DUET-D User manual

Vemer
Vemer memo AST Series User manual

Vemer
Vemer memo AST2 User manual

Vemer
Vemer ELO-D User manual

Vemer
Vemer ELO-D User manual
Popular Switch manuals by other brands

Danfoss
Danfoss RT 260A installation guide

AMX
AMX Enova DVX-3156HD-SP datasheet

Texas Instruments
Texas Instruments TPS2149 user guide

Extreme Networks
Extreme Networks ExtremeSwitching CES 2000 Series Hardware installation guide

SMC Networks
SMC Networks EZ Switch SMC-EZ108DT quick start guide

Eaton
Eaton BZM1-XA installation instructions