VEVOR SS-Y01 User manual

MODEL:SS-Y01
Warning-To reduce the risk of injury, user must read
instructions manual carefully.
This product is subject to the provision of European Directive
2012/19/EC. The symbol showing a wheelie bin crossed through
indicates that the product requires separate refuse collection in the
European Union. This applies to the product and all accessories
marked with this symbol. Products marked as such may not be
discarded with normal domestic waste, but must be taken to a
collection point for recycling electrical and electronic devices

WARNING:Use in unoccupied spaces only
Cautions:
It is forbidden to use in flammable , explosive , humid and other harsh
environments
It is forbidden to cover the air inlet and outlet . and the exhaust hole is
strictly prohibited to block foreign objects
The ozone generator is a high-voltage product and should be placed in a
safe place and ensured to be in a solid state when in use
When the ozone generator is working , please make sure that there are no
people , pets and living things in the room
Ozone has strong oxidizing properties , we recommend that the operating
time of the device does not exceed 2 hours each time
Ozone is extremely unstable , automatically decomposes into oxygen after
one hours , no pollution and no residue
Ozone has a special smell , if you are sensitive to the smell of ozone ,
please keep away from the device
Non-professionals are not allowed to disassemble the device without
authorization . If it is not used for a long time , the power supply should be
cut off
The device must be powered off during maintenance , and the power must
be cut off immediately when an abnormality is found
The device is for adult use only , do not allow children to operate the device
Functional application:
Ozone ( 03) is an allotrope of oxygen ( O2) . It is gaseous at room
temperature.
When the concentration is low , it is colorless and has a grassy smell . The
chemical properties of ozone are more active and have strong oxidizing
power . When it encounters bacteria and harmful chemicals ( such as
formaldehyde , benzene ,ammonia ) , it will immediately produce an
oxidation reaction , thereby achieving the functions of sterilization and
disinfection , deodorization , and decomposition of harmful gases . Ozone
is extremely unstable and will be reduced to O2 within a few hours , so
there is no pollution and residue . It is the only substance recognized in the

world that can directly sterilize food and beverages so far!
1 . Using the strong oxidizing properties of ozone can remove toxic
substances released by decoration , synthetic boards , and paints , kill
bacteria and viruses in the air , kill microorganisms that breed in carpets .
eliminate cold germs , prevent the occurrence of flu , and increase Indoor
oxygen content .
2 . Ozone has excellent odor removal performance . The main components
of odor are amine R3N , hydrogen sulfide H2S , methyl mercaptan
CH2SH , etc . The strong oxidizing performance of ozone can quickly
decompose odor and other organic or inorganic substances
Parameter Table
HOW TO USE
1 . Insert the plug of the power cord into the socket of the disinfection
machine ,and connect the other end to the 120V 60HZ AC power supply
2 . Turn on the power switch of the sterilizer , the red light is on , it means the
machine is powered on.
Model
SS-Y01
Voltage
AC120 V
AC120 V
AC120 V
Frequency
60 Hz
60 Hz
60 Hz
Power
80 W
100 W
130 W
Ozone
production
12g/h
24g/h
36g/h

3 . Set working status
Normally open : Turn the timing knob counterclockwise , and when the pointer of
the knob is aligned with the " HOLD " gear , the device will start and there is no
timing function
Off : Turn the knob and the pointer is aligned with the " OFF " gear , the equipment
stops working
Timing : Turn the knob clockwise , the pointer is aligned with the number on the
dial , and the device is in timing working mode
The number pointed by the pointer is the set working time . The equipment stops
working at the end of working hours .
( For example : the pointer in the figure below is aligned with 40 ,that is , the device
will shut down after 40 minutes of operation)

Note : Regardless of whether it is in the normally open mode or the
timing mode , the cumulative working time for a single operation
should not exceed1 hour.
Precautions:
1 . It is forbidden to use in flammable , explosive , humid and other harsh
environments
2 . It is forbidden to cover the inlet and outlet
3 . People should be evacuated temporarily when the equipment is working
4 . The power must be cut off during equipment maintenance
5 . Non-professionals are not allowed to disassemble the equipment
without authorization
6 . Cut off the power supply if it is not used for a long time ,
7 . The cumulative working time at one time does not exceed 1 hour , and
the equipment can be restarted after cooling down ,
8 . Regularly check whether the equipment is working normally , and
immediately cut off the power supply if any abnormality is found