Item no. Rec.
pump size dimension UVC ID
pipe
size
filtering
capacity Filter
height
UPC#
0069037
EF-3000UVC 700-1300
GPH 15" x
14.25" 5 w 1.25
in.
or
1.5
in.
15.5 L 14.25
in. 2953 6
EF-4000UVC 1300-2100
GPH 15" x
18.25" 9 w 21.5 L 18.25
in. 2955 0
EF-5000UVC 1300-3000
GPH 15" x
22.25" 9 w 27.5 L 22.25
in. 2957 4
EF-6000UVC 1300-4000
GPH 15" x
26.25" 9 w 33.5 L 26.25
in. 2959 8
1. Intake
2. Ouput
3. Backwash/sludge removal
4. Backwash knob
5. Terminatorâ„¢ UVC Sterilizer (optional)
6. Barbed fitting
7. Lid retainer clamp
8. Intake & Output tube
9. Fine bio foam
10. Medium bio foam
11. Coarse bio foam
12. Intake & output flares
13. Ceramic bio strainer
14. Ceramic bio chamber with media
15. Coarse prefilter
15. Filter body
Copyright ©2022 - SeaSun aquarium - https://seasunaquarium.com/shop _PN_PAGE 3 _PN_OF 9

TYPICAL OPERATION
For proper filtration, operate the pressure pond filter 24 hours a day, year
round.
Start the ViaAqua® pond pump. Verify that all seals and connections are not
leaking.
BACKWASH OPERATION
Remove the cap from the backwash/drain port. Connect a barbed fitting with a
piece of tubing and secure with a hose clamp. To activate backwash, turn off
the pond pump and switch the flow control knob so that the arrow points to the
backwash/drain discharge port. Turn the pond pump back on. Drain the water
into a sewage system or garden.
Backwashing filter should be performed at least once a week.
The filter needs to be cleaned when:
- Dirty/cloudy water is in the filter.
- Reduced water flow.
FILTER SPONGES
When backwashing, if the filter does not produce expected results, it is necessary to clean or replace
foam media. This should be performed at least once a season. However, this is not a rule for pond
and outdoor environments vary thus more frequent cleaning may be required.
1. Unplug the Terminatorâ„¢ UV Sterilizer and turn the pond pump off.
2. Disconnect the barbed fitting from the filter.
Copyright ©2022 - SeaSun aquarium - https://seasunaquarium.com/shop _PN_PAGE 7 _PN_OF 9

3. Flip out safety lock and remove lid retainer clamp.
4. Remove the lid of the filter. Handle with care. The UV bulb and quartz sleeve is made of glass.
5. Remove the intake and output flares.
6. Remove and rinse foam pads. Replace them if necessary.
7. Remove the bio-chamber and rinse well with pond water only. Biological media beneficial bacteria will
be killed if tap water is used to rinse.
8. Remove and rinse pre-filter foam pads. Replace them if necessary.
9. Rinse and clean the filter body.
10. Place the filtering media back in their original locations. Replace intake and output flares.
11. Replace o-ring and verify that it is clean. We recommend using a small amount of silicone lubricant
on the o-ring to ensure a proper seal.
12. Secure lid with lid retainer clamp. The lid retainer clamp must be aligned so that the notches in the
top of the clamp fit under the intake and discharge port.
13. Filter is ready to use. See installation instructions.
REPLACEMENT OF UV BULB (UV Model)
1. Follow all the safeguards and warnings of the manufacture.
2. Before doing any maintenance on the UV sterilizer, the power supply and water supply must be
disconnected.
3. Only in rare situations does the quartz sleeve ever have to be removed. If necessary loosen screws
carefully, then remove the quartz sleeve. If excess force is used the quartz sleeve will break. After
removed, use a soft clean cloth to gently remove any excess grim and/or debris. Reassemble using a
small amount of silicone lubricant placed on the o-ring prior to sliding it into the main body of the UV
sterilizer.
4. The UV bulb needs to be replaced every 8,000 to 9,000 hours. This will ensure optimum performance.
5. The efficiency of the Terminatorâ„¢ UV Sterilizer depends on the duration the UV light is in contact with
water. Thus the rate of water flow, not the way the water travels, will relate to the efficiency of the UV
sterilizer.
Number pieces in packaging:1 Number pieces in box:2
Customer Reviews: There are yet no reviews for this product.
Please log in to write a review.
Copyright ©2022 - SeaSun aquarium - https://seasunaquarium.com/shop _PN_PAGE 8 _PN_OF 9
This manual suits for next models
3
Table of contents
Other ViaAqua Pond Pump manuals
Popular Pond Pump manuals by other brands

Clarke
Clarke SSP3 Operating & maintenance instructions

MATALA
MATALA MEA Lake Pro Kits manual

Messner
Messner MultiSystem M 20000 operating instructions

Oase
Oase AquaMax Eco Classic 9000 C operating instructions

HEISSNER
HEISSNER Smartline HSP5000-00 Instructions for use

Oase
Oase AquaMax Eco Titanium 31000 operating instructions