Multiple Streams Ultra High Definition Fisheye IP Camera (Outdoor) Quick Guide
The Quick Guide is for quick installing and connecting the V9360W-1 Fisheye IP Camera (Outdoor). For more details,
please refer to the User’s Manual of the camera in the supplied CD.
Function Cables
No.
Connector
Pin
Definition
Remarks
1 Audio I/O
Pink
Audio In
Two-way audio transmission
Green
Audio Out
2 Power (DC 12V/AC 24V)
(2-Pin Terminal Block)
Black
AC 24 V –
Power connection
DC 12V –
Red
AC 24V +
DC 12V +
3 Alarm I/O
(4-Pin Terminal Block)
1
Alarm In –
Alarm connection
2
Alarm In +
3
Alarm Out –
4
Alarm Out +
4
GND
-
GND
Ground connection
5
RJ-45
-
For network and PoE connections
microSD Card Slot / Default Button
The camera’s microSD card slot and default button are inside the camera cover. To use them, loosen the two security
screws of the camera with the supplied security torx and detach the cover. Refer to the followings for their positions
and function.
microSD Card Slot
Insert the microSD card (not supplied) into the card slot to store videos and snapshots. Do not remove the microSD
card when the camera is powered on.
NOTE: It is not recommended to record with the microSD card for 24/7 continuously, as it may not be able to
support long term continuous data read/write. Please contact the manufacturer of the microSD card for
information regarding the reliability and the life expectancy.
Default Button
Press the button with a proper tool for at least 20 seconds to restore the system.
Camera Cabling
Please follow the instructions below for cable connections.
Power Connection
Please use a DC 12V/AC 24V power adaptor and plug it to the camera and the power outlet. Alternatively, users can
use an Ethernet cable and connect it to the RJ-45 connector of the camera and a Power Sourcing Equipment (PSE)
switch.
NOTE: If PoE is used, make sure PSE is in use in the network.
Ethernet Cable Connection
Connect one end of the Ethernet cable to the RJ-45 connector of the camera, and plug the other end of the cable to
the network switch or PC.
NOTE: In some cases, Ethernet crossover cable might be needed when connecting the camera directly to the
PC.
NOTE: Check the status of the link indicator and activity indicator LEDs. If the LEDs are unlit, please check
the LAN connection.
Green Link Light indicates good network connection.
OrangeActivity Light flashes for network activity indication.
Before Login to the Camera
A client program will be automatically installed to the PC when connecting to the camera. Before logging in to the
camera, please ensure downloading the ActiveX control is allowed by either changing the ActiveX controls and
plug-ins or setting Internet’s security level to default. For further details, please refer to the User’s Manual in the
supplied CD.
ActiveX Controls and Plug-ins Settings
Internet Security Level
Step 1: Start the Internet Explorer (IE).
Step 2: Select <Tools> from the
main menu of the
browser. Then click on <Internet Options>.
Step 3: Click on the <Security> tab
and select
<Internet>
, and click on <Custom level> to
change ActiveX settings.
Step 4: Set “ActiveX controls and plug-ins”
items to
<Prompt> or <Enable>.
Step 1: Start the Internet Explorer (IE).
Step 2: Select <Tools> from the
main menu of the
browser. Then click on <Internet Options>.
Step 3: Click on the <Security> tab
and select
<Internet>.
Step 4: Down the page, click <Default Level> and click
on <OK> to confirm the setting. Close the
browser window, and open a new one later for
accessing the IP camera.
Camera Login
The default IP address of the camera is found via DHCP for example:
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0
Login ID and Password
•Key in the camera’s IPaddress in the URL bar of the web browser window and hit on “Enter”.
•Enter the default username (ADMIN) and password (1234) in the prompt request dialog. Note that username is
case sensitive.
Install the ActiveX Control
•After connecting to the camera, the request for installing theActiveX control will appear just below the URL bar.
•Right click on the information bar, and then click on <Install ActiveX Control…> to permit ActiveX control
installation.
•In the pop-up security warning window, click on <Install> to start downloading DC Viewer software on the PC.
•Click on <Finish> after DC Viewer installation is completed.
Browser-based Viewer
The main page of the IP camera user interface is shown as the figure below. Please note that function buttons will
vary depending on the camera model.

Other manuals for V9360-1

4

This manual suits for next models

1

Other Vicon IP Camera manuals

Vicon I-Onyx MP-955 User manual

Vicon

Vicon I-Onyx MP-955 User manual

Vicon I-Onyx MP-955 User manual

Vicon

Vicon I-Onyx MP-955 User manual

Vicon IQeye R5 Series User manual

Vicon

Vicon IQeye R5 Series User manual

Vicon V661D-312D Operating instructions

Vicon

Vicon V661D-312D Operating instructions

Vicon IQeye Alliance-mx User manual

Vicon

Vicon IQeye Alliance-mx User manual

Vicon XX258-10-00 User manual

Vicon

Vicon XX258-10-00 User manual

Vicon XX247-20-04 User manual

Vicon

Vicon XX247-20-04 User manual

Vicon I-ONYX VND-970IP Owner's manual

Vicon

Vicon I-ONYX VND-970IP Owner's manual

Vicon VC2430B User manual

Vicon

Vicon VC2430B User manual

Vicon SurveyorVFT SVFT-M User manual

Vicon

Vicon SurveyorVFT SVFT-M User manual

Vicon V9360 User manual

Vicon

Vicon V9360 User manual

Vicon XX235-10-00 Operating instructions

Vicon

Vicon XX235-10-00 Operating instructions

Vicon ROUGHNECK V910 User manual

Vicon

Vicon ROUGHNECK V910 User manual

Vicon VN-755IPV3 User manual

Vicon

Vicon VN-755IPV3 User manual

Vicon I-ONYX MP-955IR User manual

Vicon

Vicon I-ONYX MP-955IR User manual

Popular IP Camera manuals by other brands

Vista VK2-1080MD37PTW quick guide

Vista

Vista VK2-1080MD37PTW quick guide

AVer VC320 user manual

AVer

AVer VC320 user manual

Okina WDEM-7680 Quick setup guide

Okina

Okina WDEM-7680 Quick setup guide

Phylink PLC-325PW Bullet HD Quick install guide

Phylink

Phylink PLC-325PW Bullet HD Quick install guide

Alfa Network AWOR-315 Specifications

Alfa Network

Alfa Network AWOR-315 Specifications

KT&C ACE-M321 Operation manual

KT&C

KT&C ACE-M321 Operation manual

Taser Axon Flex 2 quick start guide

Taser

Taser Axon Flex 2 quick start guide

ACTi KCM-5211 Hardware manual

ACTi

ACTi KCM-5211 Hardware manual

Moxa Technologies VPort 36-1MP Quick installation guide

Moxa Technologies

Moxa Technologies VPort 36-1MP Quick installation guide

cycliq Fly12 quick start guide

cycliq

cycliq Fly12 quick start guide

ZyXEL Communications AURORA CAM3115 user guide

ZyXEL Communications

ZyXEL Communications AURORA CAM3115 user guide

Wansview M SERIES user manual

Wansview

Wansview M SERIES user manual

Planet Networking & Communication ICA-W3250V Quick installation guide

Planet Networking & Communication

Planet Networking & Communication ICA-W3250V Quick installation guide

Bosch TC9376H instruction manual

Bosch

Bosch TC9376H instruction manual

Tenvis JPT3815W quick start guide

Tenvis

Tenvis JPT3815W quick start guide

Inscape Data AirGoogle NVC360 user manual

Inscape Data

Inscape Data AirGoogle NVC360 user manual

XIMEA xiQ quick start guide

XIMEA

XIMEA xiQ quick start guide

SWIT CH-1100LG(2GB) manual

SWIT

SWIT CH-1100LG(2GB) manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.