manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Victron energy
  6. •
  7. Controllers
  8. •
  9. Victron energy NV-48030 User manual

Victron energy NV-48030 User manual

1
Intelligent
Intelligent
Intelligent
Intelligent Solar
Solar
Solar
Solar Charge
Charge
Charge
Charge Controller
Controller
Controller
Controller
User
User
User
User
’
’
’
’
s
s
s
s Manual
Manual
Manual
Manual
Please
Please
Please
Please read
read
read
read this
this
this
this manual
manual
manual
manual carefully
carefully
carefully
carefully before
before
before
before you
you
you
you use
use
use
use this
this
this
this product.
product.
product.
product.
2
2
2
2
3
3
3
3
Catalogue
Catalogue
Catalogue
Catalogue
1.
1.
1.
1. Product
Product
Product
Product Introduction
Introduction
Introduction
Introduction …………………………………………
…………………………………………
…………………………………………
………………………………………… .4
.4
.4
.4
2.
2.
2.
2. Installation
Installation
Installation
Installation ……………………………………………………
……………………………………………………
……………………………………………………
…………………………………………………… ..5
..5
..5
..5
3.
3.
3.
3. Operation
Operation
Operation
Operation ………………………………………………………
………………………………………………………
………………………………………………………
……………………………………………………… 6
6
6
6
4.
4.
4.
4. Common
Common
Common
Common Fault
Fault
Fault
Fault and
and
and
and H
H
H
H andling
andling
andling
andling …
…
…
… ..
..
..
.. ………
………
………
……… .
.
.
. ……………………
……………………
……………………
……………………
1
1
1
1
1
1
1
1
5.
5.
5.
5. Technical
Technical
Technical
Technical Data
Data
Data
Data …………………………………………………
…………………………………………………
…………………………………………………
………………………………………………… 1
1
1
1 3
3
3
3
4
4
4
4
1.
1.
1.
1. Product
Product
Product
Product Introduction
Introduction
Introduction
Introduction
NV series controller is a kind of intelligent, multi-purpose solar charge and discharge controller. The
family use the fixed LCD display, with a very friendly interface; various control parameters can be flexibly
set, fully meet your various application requirements. NV series controller has following features:
Image of LCD graphic symbol Simple button operation
Automatic Identification System Voltage level Intelligent PWM charge mode
Automatic Temperature Compensation Adjustable charge-discharge control parameters
Settable Operating mode of Load Overload, Short Circuit Protection
Remote monitoring and control function (custom) Battery reverse-discharge protection
Battery Low V oltage Disconnection (LVD) Battery reverses connection protection
Accumulated function of charge and discharge Ampere hours
A
5
5
5
5
2.
2.
2.
2. Installation
Installation
Installation
Installation
Install
Install
Install
Install
:
1
Ready tools and cables. Encourage you to matching the right cables.
Ensure that the current density <4mm ² that is conductive to reducing
the line voltage drop. Recommended: 30A with 10mm ² cable. Check
weather the installation sites compliance with the relevant safety
requirements. Please avoid the damp, dusty, there is a place flammable,
explosive and corrosive gases use the controller to install.
2
Install the controller into a fixed vertical plan e. See section 5 of the pore
size and pore spacing. In order to ensure a good thermal control
conditions, please set aside each 10cm below the controller space.
3
A s shown on the right, connect the (1) Load, (2) Battery and (3) Solar
Panel to the controller according to the order of (1) (2) (3). Pay attention
to the load, battery, solar panel and controller of same polarity.
4
Put into the external temperature sensor on the left of the controller
(probe port). T he temperature sensor should be similar space with battery. (Otherwise, the controller will control the parameters of all
6
6
6
6
wrong temperature compensation.)
5
If you have remote monitoring and control function, please insert one end of the included communication wire on the right of the
controller (communication port), the other end to connect to the host computer.
Demolition:
Demolition:
Demolition:
Demolition:
To
prevent accidents, please order the d emolition of solar panels, battery and load disconnect with controller.
Note
Note
Note
Note :Battery
Battery
Battery
Battery polarity
polarity
polarity
polarity will
will
will
will not
not
not
not damage
damage
damage
damage the
the
the
the controller,
controller,
controller,
controller, but
but
but
but you
you
you
you will
will
will
will have
have
have
have a
a
a
a load
load
load
load equipment
equipment
equipment
equipment se
se
se
se curity
curity
curity
curity risks.
risks.
risks.
risks.
3.
3.
3.
3. Operation
Operation
Operation
Operation
1
1
1
1 Description
Description
Description
Description of
of
of
of LCD
LCD
LCD
LCD graphic
graphic
graphic
graphic symbol
symbol
symbol
symbol
:
Stop-powered Status for Loads
:
Stop the battery charging
:
Power to the load status,
:
Bulk charging the battery
the load circuit without current :Float charging the battery
:
The load circuit with current
:
The system is working correctly
:Load :The system is not working properly
:Solar Panel :Battery charge capacity instruction
:
Load sensor control
:
Battery
:Load timer control
2
2
2
2 Description
Description
Description
Description of
of
of
of Button
Button
Button
Button Function
Function
Function
Function :
:
:
:
:
:
:
:Interface loop switch button, use the button to cycle between pages in each switch cycle sequence
7
7
7
7
shown in (figure 1)
:
:
:
:Adjustment of parameters plus buttons. In addition, at the state in the parameter view, long press the
button more than 5 seconds, all parameter to restore factory setting.
:
:
:
:Adjustment of parameters minus button. In addition, in the main interface, click this button to switch
the load.
Battery Voltage Battery Solar Panel Load Accumulated
(main interface )temperature charge current discharge current charging power (Ah)
Load working High Voltage Low voltage Low Voltage Accumulated
Mode Disconnection (HVD) Reconnection (LVR) Disconnection (LVD) Discharging power (Ah)
Figure
Figure
Figure
Figure 1
1
1
1
3
3
3
3 View
View
View
View and
and
and
and set
set
set
set the
the
the
the parameters:
parameters:
parameters:
parameters:
The controller will default entry “battery voltage ”interface after correct power-on. This is the main
interface. Use the button could in turn visit the following parameters interface. If that interface could be
8
8
8
8
set, long press the button
( >
5 seconds
,
numbers start flashing
)
To
enter the parameter setting interface;
set out the parameter interface after long press the button again. (The numbers stops flashing)
3.1
3.1
3.1
3.1 Battery
Battery
Battery
Battery Voltage
Voltage
Voltage
Voltage of
of
of
of View
View
View
View
As shown on the right, displays the value for current battery voltage. This
interface (based interface) displays charge status, discharge status, battery
capacity and battery voltage.
3.2
3.2
3.2
3.2 The
The
The
The load
load
load
load on/off
on/off
on/off
on/off control
control
control
control
View the interface in the battery voltage could be used key
On, off the load
In other interface, the key there is no such feature.
3.3
3.3
3.3
3.3 Environment
Environment
Environment
Environment Temperature
Temperature
Temperature
Temperature of
of
of
of View
View
View
View
As shown on the right, displays the ambient temperature of the controller,
the value used for temperature compensation on LVD function.
The sensor must be plug in before using the controller.
3.4
3.4
3.4
3.4 Solar
Solar
Solar
Solar Panel
Panel
Panel
Panel charging
charging
charging
charging current
current
current
current of
of
of
of View
View
View
View
9
9
9
9
As shown on the right, display the value of charging current from solar panel.
3.5
3.5
3.5
3.5 Load
Load
Load
Load discharging
discharging
discharging
discharging current
current
current
current of
of
of
of View
View
View
View
As shown on the right, display the value of discharging current for Loads.
3.6
3.6
3.6
3.6 View
View
View
View the
the
the
the Accumulated
Accumulated
Accumulated
Accumulated charging
charging
charging
charging power
power
power
power (Ah)
(Ah)
(Ah)
(Ah) by
by
by
by solar
solar
solar
solar panel
panel
panel
panel and
and
and
and back
back
back
back to
to
to
to zero
zero
zero
zero
As shown on the right, display the accumulated charging power from solar panel
(Total ampere hour), long press the button more than 5seconds,
the value will back to zero.
3.7
3.7
3.7
3.7 View
View
View
View the
the
the
the Accumulated
Accumulated
Accumulated
Accumulated discharging
discharging
discharging
discharging power
power
power
power (Ah)
(Ah)
(Ah)
(Ah) by
by
by
by Load
Load
Load
Load and
and
and
and back
back
back
back to
to
to
to zero
zero
zero
zero
As shown on the right, display the accumulated discharging power for loads
(Total ampere hour), long press the button more than 5seconds, the value will
back to zero.
3.8
3.8
3.8
3.8 View
View
View
View and
and
and
and set
set
set
set the
the
the
the Low
Low
Low
Low Voltage
Voltage
Voltage
Voltage Disconnection
Disconnection
Disconnection
Disconnection Protection
Protection
Protection
Protection
As shown on the right, shows the values for the LVD protection voltage.
When the battery voltage is lower than protection voltage, the controller will
disconnect the load circuit to prevent battery over-discharge.
Long press the button (> 5 seconds )in this interface ,numbers start flashing,
10
10
10
10
that has entered the LVD setup interface, you can use the key
、
to adjust
the parameter. After long press the key
(>
5 seconds
)
to exit parameter setting
interface, the controller will save the settings.
3.9
3.9
3.9
3.9 View
View
View
View and
and
and
and set
set
set
set the
the
the
the Low
Low
Low
Low Voltage
Voltage
Voltage
Voltage Reconnection
Reconnection
Reconnection
Reconnection
As shown on the right, shows the values for the LVR voltage. Under the LVD
protection in the controller, when the battery voltage is restored to the higher voltage
than LVR voltage, the controller will re-connect the load circuit.
Long press the button
(>
5 seconds
)
in this interface
,
numbers start flashing,
that has entered the LVR setup interface, you can use the key
、
to adjust the
parameter. After long press the key
(>
5 seconds
)
to exit parameter setting interface,
the controller will save the settings.
3.10
3.10
3.10
3.10 View
View
View
View and
and
and
and set
set
set
set the
the
the
the High
High
High
High Voltage
Voltage
Voltage
Voltage Disconnection
Disconnection
Disconnection
Disconnection
As shown on the right, shows the values for the HVD voltage. When the battery
voltageis reach to HVD voltage, the controller will cut off the charging circuit to
prevent over-charging battery. Battery voltage drops under the value the charging
circuit will be re-connected.
11
11
11
11
Long press the button
(>
5 seconds
)
in this interface
,
numbers start flashing,
that has entered the HVD setup interface, you can use the key
、
to adjust the
parameter. After long press the key
(>
5 seconds
)
to exit parameter setting interface,
the controller will save the settings.
3.11
3.11
3.11
3.11 View
View
View
View and
and
and
and set
set
set
set Load
Load
Load
Load Working
Working
Working
Working Mode
Mode
Mode
Mode
As shown on the right is Load working mode interface, different values represent different load working
patterns.
24h — said Normal Mode, in case of no fault state of the load is always in power.
1h ~23h — said Light Control with Time Control Mode, Load power after dark,
and close the load according to the timer setting.
0h — said Light Control Mode, Load power after dark, turn off the load after drawn.
Long press the button
(>
5 seconds
)
in this interface
,
numbers start flashing,
that has entered the Load Working Mode setup interface, you can use the key
、
to adjust the parameter.
After long press the key
(>
5 seconds
)
to exit parameter setting interface, the controller will save the
settings.
4.
4.
4.
4. Common
Common
Common
Common Fault
Fault
Fault
Fault and
and
and
and H
H
H
H andling
andling
andling
andling
LVD
LVD
LVD
LVD Protection
Protection
Protection
Protection and
and
and
and Treatment:
Treatment:
Treatment:
Treatment:
12
12
12
12
Screen display as shown in the figure that the battery drops below the LVD
protection voltage. The controller has entered the LCD protection state, load circuit
has been disconnected. Use the solar panels recharge the battery or charger when the
battery voltage reaches LVR voltage, the controller will resume on the load power
supply, into the normal working state.
Overload
Overload
Overload
Overload Protection
Protection
Protection
Protection and
and
and
and Treatment:
Treatment:
Treatment:
Treatment:
Screen display (see the figure) and flashing expressed load loop circuit current
sustained 60seconds than 1.5times rated current, the controller has entered into
overload protection state. After reduce the load, press the button to restore
power to the load.
Short
Short
Short
Short Circuit
Circuit
Circuit
Circuit Protection
Protection
Protection
Protection and
and
and
and Treatment:
Treatment:
Treatment:
Treatment:
Screen display (see the figure on the right) and flashing expressed there is short
circuit on the load loop circuit. The controller has enter into Short Circuit Protection
state Check the load if there is damage or not, if there is cable short circuit or not,
after trouble shooting short press the button for restoration.
Solar
Solar
Solar
Solar Panel
Panel
Panel
Panel Fault
Fault
Fault
Fault and
and
and
and Treatment
Treatment
Treatment
Treatment :
Symbol flashing represent the controller was not detected solar panels within 24hours. Check if there
is a connection from solar panel, check if there is an open circuit between solar panels with controller.
Load
Load
Load
Load Shock
Shock
Shock
Shock Fault
Fault
Fault
Fault
:
Open load if the flashing , that indicate the load impulse current is more than twice rated current of the
13
13
13
13
controller. The controller is restarting the load in action many timers do.
5.
5.
5.
5. Technical
Technical
Technical
Technical Data
Data
Data
Data
Data
Data
Data
Data
Model
Model
Model
Model
NV-12030D
NV-12030D
NV-12030D
NV-12030D NV-48030
NV-48030
NV-48030
NV-48030
Data
Data
Data
Data
Model
Model
Model
Model
NV-12030D
NV-12030D
NV-12030D
NV-12030D NV-48030
NV-48030
NV-48030
NV-48030
Rated
Rated
Rated
Rated Current
Current
Current
Current 30A 0 30A
Installation
Installation
Installation
Installation cable
cable
cable
cable
area.
area.
area.
area.
≤
≤
≤
≤7# AWG (16mm
2
)
Rated
Rated
Rated
Rated Voltage
Voltage
Voltage
Voltage 12V/24V 48V
Operating
Operating
Operating
Operating
Temperature
Temperature
Temperature
Temperature
-10 ℃~60 ℃
Open
Open
Open
Open Circuit
Circuit
Circuit
Circuit
Voltage
Voltage
Voltage
Voltage of
of
of
of solar
solar
solar
solar panel
panel
panel
panel
≤
≤
≤
≤50V ≤
≤
≤
≤100V
Storage
Storage
Storage
Storage
temperature
temperature
temperature
temperature
-30 ℃~70 ℃
Low
Low
Low
Low Voltage
Voltage
Voltage
Voltage
Disconnection(LVD)
Disconnection(LVD)
Disconnection(LVD)
Disconnection(LVD)
10.7V/21.4V 42.8V
Humidity
Humidity
Humidity
Humidity
requirements
requirements
requirements
requirements
≤ 90 %, no condensation
Float
Float
Float
Float Voltage
Voltage
Voltage
Voltage 13.8V/27.6V 55.2V Size
Size
Size
Size 90 mm × 188 mm × 48 mm
Low
Low
Low
Low Voltage
Voltage
Voltage
Voltage
Reconnection(LVR)
Reconnection(LVR)
Reconnection(LVR)
Reconnection(LVR)
12.5V/25.0V 50.0V
Mounting
Mounting
Mounting
Mounting hole
hole
hole
hole
spacing
spacing
spacing
spacing
60 mm × 178 mm -- Φ 5
14
14
14
14
No
No
No
No load
load
load
load loss
loss
loss
loss ≤
≤
≤
≤30mA
≤
≤
≤
≤
weight
weight
weight
weight 360g
Loop
Loop
Loop
Loop Voltage
Voltage
Voltage
Voltage Drop
Drop
Drop
Drop ≤
≤
≤
≤170mV
≤
≤
≤
≤
Notes
Notes
Notes
Notes
Model suffix “ Z ” represent automatic
identify system voltage level ,
“ T ” represent controller with remote
monitoring.
Charging
Charging
Charging
Charging Mode
Mode
Mode
Mode
PWM mode
Temperature
Temperature
Temperature
Temperature
Compensation
Compensation
Compensation
Compensation
-4mV/Cell/ ℃

This manual suits for next models

1

Other Victron energy Controllers manuals

Victron energy BlueSolar MPPT 75/15 User manual

Victron energy

Victron energy BlueSolar MPPT 75/15 User manual

Victron energy BlueSolar MPPT 150/35 User manual

Victron energy

Victron energy BlueSolar MPPT 150/35 User manual

Victron energy CCGX User manual

Victron energy

Victron energy CCGX User manual

Victron energy VBC-HV User manual

Victron energy

Victron energy VBC-HV User manual

Victron energy SHS 200 MPPT User manual

Victron energy

Victron energy SHS 200 MPPT User manual

Victron energy SmartSolar MPPT 100/50 User manual

Victron energy

Victron energy SmartSolar MPPT 100/50 User manual

Victron energy BlueSolar PWM Series User manual

Victron energy

Victron energy BlueSolar PWM Series User manual

Victron energy BlueSolar MPPT 150/70 User manual

Victron energy

Victron energy BlueSolar MPPT 150/70 User manual

Victron energy BlueSolar MPPT 150/45-MC4 User manual

Victron energy

Victron energy BlueSolar MPPT 150/45-MC4 User manual

Victron energy BlueSolar MPPT 150/35 User manual

Victron energy

Victron energy BlueSolar MPPT 150/35 User manual

Victron energy Lynx Smart BMS User manual

Victron energy

Victron energy Lynx Smart BMS User manual

Victron energy SmartSolar MPPT 150/85 Series User manual

Victron energy

Victron energy SmartSolar MPPT 150/85 Series User manual

Victron energy BlueSolar MPPT 150/85 User manual

Victron energy

Victron energy BlueSolar MPPT 150/85 User manual

Victron energy BlueSolar MPPT 150/70 User manual

Victron energy

Victron energy BlueSolar MPPT 150/70 User manual

Victron energy Digital Multi Control 200/200A User manual

Victron energy

Victron energy Digital Multi Control 200/200A User manual

Victron energy BlueSolar MPPT 75/10 User manual

Victron energy

Victron energy BlueSolar MPPT 75/10 User manual

Victron energy CCGX User manual

Victron energy

Victron energy CCGX User manual

Victron energy BlueSolar MPPT 150/35 User manual

Victron energy

Victron energy BlueSolar MPPT 150/35 User manual

Victron energy SmartSolar MPPT RS 450 100 User manual

Victron energy

Victron energy SmartSolar MPPT RS 450 100 User manual

Victron energy SmartShunt IP65 User manual

Victron energy

Victron energy SmartShunt IP65 User manual

Victron energy CCGX User manual

Victron energy

Victron energy CCGX User manual

Victron energy BlueSolar MPPT 150/60-Tr User manual

Victron energy

Victron energy BlueSolar MPPT 150/60-Tr User manual

Victron energy EasySolar-II GX User manual

Victron energy

Victron energy EasySolar-II GX User manual

Victron energy BlueSolar PWM-Light 12/24-5 User manual

Victron energy

Victron energy BlueSolar PWM-Light 12/24-5 User manual

Popular Controllers manuals by other brands

Duomo GS300Mc manual

Duomo

Duomo GS300Mc manual

Intermec 4980 Programmer's guide

Intermec

Intermec 4980 Programmer's guide

Bodet Scorepad user manual

Bodet

Bodet Scorepad user manual

Emerson Bettis G Series Installation, operation and maintenance manual

Emerson

Emerson Bettis G Series Installation, operation and maintenance manual

ELPRO ULTIMA LLC-2 operating manual

ELPRO

ELPRO ULTIMA LLC-2 operating manual

Deif CGC 200 Operator's manual

Deif

Deif CGC 200 Operator's manual

Autonics TZ Series product manual

Autonics

Autonics TZ Series product manual

Konica Minolta bizhub PRO C5501 Release notes

Konica Minolta

Konica Minolta bizhub PRO C5501 Release notes

gefran GFW 40-300A installation manual

gefran

gefran GFW 40-300A installation manual

iNels KEY2-01 Manual instructions

iNels

iNels KEY2-01 Manual instructions

Cielo Breez Lite user manual

Cielo

Cielo Breez Lite user manual

Vacon 100 INDUSTRIAL user manual

Vacon

Vacon 100 INDUSTRIAL user manual

INVT SV-DA200 Series Operation manual

INVT

INVT SV-DA200 Series Operation manual

Mitsubishi Electric AJ65BT64DAV/DAI user manual

Mitsubishi Electric

Mitsubishi Electric AJ65BT64DAV/DAI user manual

Ruida Technology RDLC320 user manual

Ruida Technology

Ruida Technology RDLC320 user manual

VDH Products MC 785-SC operating manual

VDH Products

VDH Products MC 785-SC operating manual

IOTA IQ-AGM owner's manual

IOTA

IOTA IQ-AGM owner's manual

Chauvet DMX-55 user manual

Chauvet

Chauvet DMX-55 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.