Viega 8350.33 User manual

For concealed cistern 1F in combination with WC flush plates
Visign for Public 1, Visign for Style 10, 13, 14 and standard
Model Year built:
8350.33 from 05/2012
en_INT
WC flush actuation
Instructions for Use

WC flush actuation 2 from 42

Table of contents
1About these instructions for use 4
1.1 Target groups 4
1.2 Labelling of notes 4
1.3 About this translated version 5
2Product information 6
2.1 Standards and regulations 6
2.2 Safety advice 6
2.3 Intended use 7
2.3.1 Areas of use 7
2.4 Product description 8
2.4.1 Overview 8
2.4.2 Technical data 9
2.4.3 Operating mode 10
2.4.4 System expansions 11
2.4.5 Setting options 15
2.5 Accessories 16
3Handling 18
3.1 Assembly information 18
3.1.1 Mounting conditions 18
3.1.2 Required material and tools 19
3.2 Assembly 20
3.2.1 Mounting the power pack 20
3.2.2 Preparing the installation 21
3.2.3 Mounting the flush actuation (cistern 1F) 24
3.2.4 Connecting external sensors 31
3.3 Commissioning 32
3.3.1 Setting the flush 32
3.3.2 Setting Viega Hygiene+ function 35
3.4 Faults, faults and remedy 40
3.5 Care and maintenance 40
3.5.1 Care tips 40
3.5.2 Replacing the battery 41
3.6 Disposal 42
Table of contents
WC flush actuation 3 from 42

1 About these instructions for use
Trade mark rights exist for this document; for further information, go to
viega.com/legal
.
1.1 Target groups
The information in this instruction manual is directed at the following
groups of people:
nHeating and sanitary professionals and trained personnel
nQualified electricians
nOperators
nConsumers
It is not permitted for individuals without the abovementioned training or
qualification to mount, install and, if required, maintain this product. This
restriction does not extend to possible operating instructions.
The installation of Viega products must take place in accordance with
the general rules of engineering and the Viega instructions for use.
1.2 Labelling of notes
Warning and advisory texts are set aside from the remainder of the text
and are labelled with the relevant pictographs.
DANGER!
This symbol warns against possible life-threatening injury.
WARNING!
This symbol warns against possible serious injury.
CAUTION!
This symbol warns against possible injury.
NOTICE!
This symbol warns against possible damage to property.
About these instructions for use
WC flush actuation 4 from 42

Notes give you additional helpful tips.
1.3 About this translated version
This instruction for use contains important information about the choice
of product or system, assembly and commissioning as well as intended
use and, if required, maintenance measures. The information about the
products, their properties and application technology are based on the
current standards in Europe (e. g. EN) and/or in Germany
(e. g. DIN/DVGW).
Some passages in the text may refer to technical codes in Europe/
Germany. These should serve as recommendations in the absence of
corresponding national regulations. The relevant national laws, stand-
ards, regulations, directives and other technical provisions take priority
over the German/European directives specified in this manual: The
information herein is not binding for other countries and regions; as said
above, they should be understood as a recommendation.
About these instructions for use
WC flush actuation 5 from 42

2 Product information
2.1 Standards and regulations
The following standards and regulations apply to Germany / Europe.
National regulations can be found on the relevant web site of your
country at
viega.com/standards
.
Regulations from section: Fields of application / Mounting conditions
Scope / Notice Regulations applicable in Ger-
many
suitable masonry walls EN 1996-1-1
Protection area for installation of
the power pack in shower and
bath rooms
VDE 0100-701
Regulations from section: Technical data
Scope / Notice Regulations applicable in Ger-
many
Electrical approvals EN 60950
Electrical approvals EN 60335
Electrical approvals EN 61558
2.2 Safety advice
DANGER!
Danger due to electrical current
An electric shock can lead to burns and serious injury and
even death.
– Work on the electrics may only be carried out by trained
electricians.
Product information
WC flush actuation 6 from 42

2.3 Intended use
2.3.1 Areas of use
WCs in barrier-free sanitary rooms should be equipped with flush actua-
tors that can be easily reached by users and carers. For this purpose,
the flush plate of the WC can be combined with a radio-controlled or
cabled sensor using an electronic flush actuation. A sensor such as this
can be fitted on e. g. the handles of the WC or in any position in the
room.
An electrical connection must be planned for the electronic
actuation in the area of the cistern when planning.
Only the large flush volume can be actuated with electronic
actuation.
Flushes can be actuated at certain times via the Hygiene+ function to
prevent stagnation in the drinking water lines.
Installation is only possible in the following Viega concealed cisterns:
nCistern model 1F
Ascertain which model is installed before mounting. The following infor-
mation will help you to determine the model of the cistern installed:
Cistern 1F
Hygiene+ function
Suitable cisterns
Platzhalter-Bild
Product information
WC flush actuation 7 from 42

Mounting of the electronic flush actuation is only possible with the fol-
lowing WC flush plates:
Product range Name within the
product range
Model number
Standard 1 8180.1
Visign for Public 1 8326.1
Visign for Style 10, 13, 14 8315.1, 8333.1, 8334.1
2.4 Product description
2.4.1 Overview
7
8
6 45
3
2
1
Fig. 1: Scope of delivery
1 Control
2 cable tie
3 connection cable external button
4 Bowden cable unit
5 drive unit
6 drive unit holder
7 power pack 230 V
8 holder for control
Suitable manual flush plates
Product information
WC flush actuation 8 from 42

2.4.2 Technical data
The product has the following technical data:
The flush volumes for the manual flush actuation are:
nSmall flush volume: 3–4 litres
nLarge flush volume: 6–9 litres
With electronic actuation, only the large flush volume of 6 or 9 litres can
be actuated.
Input (power pack) 100–240 V AC, 50–60 Hz, 180 mA
Output (power pack) 6.5 V DC, 920 mA
Electrical approvals see section ĄRegulations from sec-
tion: Technical data“ on page 6.
Intervals 24 / 72 / 168 hours
Hygiene flush volumes 6 / 9 litres
Flush volume
Electronics
Hygiene+ function
Product information
WC flush actuation 9 from 42

2.4.3 Operating mode
Fig. 2: Actuation of the flush via an external sensor
A signal is sent to control the flush actuation through an external sensor,
e. g. a button or photo sensor.
Fig. 3: Signal transmission from the control to the motor
The control transmits the electronic signal to the drive unit.
Fig. 4: The motor operates the Bowden cable
The motor opens the drain valve via the Bowden cable.
Electronic actuation of a flush
Product information
WC flush actuation 10 from 42

Fig. 5: The water flows into WC via the open drain valve
As long as the drain valve is open, the set flush volume will flow into the
WC.
Stagnation can lead to the build up of germs (e. g. legionella) in drinking
water pipes. It is important to rinse the pipeline regularly to prevent the
build up of bacteria. The Viega Hygiene+ function was developed for
this reason.
Flushes can be actuated at certain times with the Hygiene+ function.
Interval and flush volume will be set as required and saved by the con-
trol. All settings remain saved during a power cut.
2.4.4 System expansions
The system's range of functions can be expanded through the connec-
tion of accessories onto the control.
Hygiene+ function
Product information
WC flush actuation 11 from 42

Fig. 6: Connection of the radio receiver
One requires the following accessories to be able to connect a radio
receiver – instead of a cable-connected external sensor – as shown:
Signals to actuate the flush (e. g. on support hinged handles) sent by
HEWI radio transmitters can be received by the radio receiver model
8350.35.
Radio controlled actuation
Product information
WC flush actuation 12 from 42

Fig. 7: Connection of a second external button
One requires the following accessories to be able to connect an addi-
tional external sensor as shown:
Multiple sensors can be connected at the same time using the exten-
sion cable adapter model 8350.36. This is how e. g. two external, cable-
connected buttons can be connected.
Additionally required: 1 connection cable sensitive.
Buttons, switches or photo sensors for actuating the flush can be con-
nected to the control on site via the connection cable sensitive model
8355.90.
Additional external sensors
Product information
WC flush actuation 13 from 42

Fig. 8: Connection of radio and cable sensors
One requires the following accessories to be able to connect a radio
controlled actuator alongside an external sensor as shown:
Multiple sensors can be connected at the same time using the exten-
sion cable adapter model 8350.36. This is how e. g. a button can be
combined with a radio controlled actuation.
Signals to actuate the flush (e. g. on support hinged handles) sent by
HEWI radio transmitters can be received by the radio receiver model
8350.35.
Additional radio controlled actuation
Product information
WC flush actuation 14 from 42

Fig. 9: Connection of the redundant power supply
To create a redundant power supply with an additional battery compart-
ment as shown, you will need the following accessories:
The battery compartment can be connected for a redundant power
supply using the adapter model 8355.91. The battery compartment is
included in the adapter's scope of delivery.
2.4.5 Setting options
For electronically actuated flush cycles (including Hygiene+
flushes), only large flush volumes of 6 or 9 litres can be
actuated for technical reasons although the programming
also provides for smaller flush volumes. If smaller flush vol-
umes are set, the flush is always actuated with the smallest
flush volume of 6 litres.
Flush volume
This criterion relates exclusively to the flush volume for flush cycles
actuated electronically. The flush volume for hygiene flushes is set sep-
arately.
The following settings are possible:
n4.5 litre flush volume (the flushes are always with the smallest flush
volume of 6 l) for technical reasons
n6 litre flush volume (factory setting)
n9 litre flush volume
Redundant power supply
Flush settings
Product information
WC flush actuation 15 from 42

The Hygiene+ interval
The following settings are possible:
nHygiene+ function deactivated (factory setting)
nHygiene flush 24 hours after the last use
nHygiene flush 72 hours after the last use
nHygiene flush 168 hours after the last use
Hygiene+ flush volume
The following settings are possible:
nHygiene+ flush volume 3 litres (factory setting) (For technical rea-
sons, the flushes occur with the smallest possible flush volume of 6 l)
nHygiene+ flush volume 6 litres
nHygiene+ flush volume 9 litres
2.5 Accessories
You require a flush plate so that the flush can be actuated directly at the
WC. The Viega models that can be used are found at
ĄSuitable
manual flush plates“ on page 8
.
Installation set
The set model 8350.14 contains a hollow wall socket to house the
power pack and an empty pipe with the right clip to connect the cistern
(2H).
Extension cable
2 metre cable model 8352.690 for the extension of the power supply to
a maximum of 4.75 metres in length.
Required accessories
Optional accessories
Product information
WC flush actuation 16 from 42

Programming set
This programming set is required to change the flush setting or activate
the Hygiene+ function. It contains a connection cable with a program-
ming contact and a magnetic pin. The programming contact is mounted
behind the panel and connected to the blue terminal on the control. The
programming can then take place using the magnetic pin.
Product information
WC flush actuation 17 from 42

3 Handling
3.1 Assembly information
3.1.1 Mounting conditions
The model may only be used for the models mentioned in
ÄChapter
2.3.1 „Areas of use“ on page 7
.
The power pack should be mounted in an easily accessible place to
allow subsequent access.
Before beginning to tile, a concealed socket should be installed for the
power pack with protective pipe to the cistern (installation set
Ä„Optional accessories“ on page 16
).
If necessary, the power pack cable can be extended to a length of
4.75 metres (two extension cables
Ä„Optional accessories“
on page 16
).
X1
X2
X3
Fig. 10: Installation position of the power pack
X1 max. 0.75 m
X2 max. 2.75 m with an extension cable (article number 628 505)
X3 max. 4.75 m with two extension cables (article number 628 505)
An extension of the mains supply by more than 5 metres
can lead to a situation in which the power is not sufficient to
actuate the flush.
Protected zone
Installation position of the power pack
Handling
WC flush actuation 18 from 42

Fig. 11: Protected zones
According to the applicable regulations, installation of the power pack in
the protected zones 0 and 1 of shower rooms and bathrooms is not per-
mitted, see
ĄRegulations from section: Fields of application /
Mounting conditions“ on page 6
.
Viega recommends installing the power pack outside of the protected
zones 0–2.
If external sensors are to be connected to the control, their connection
cables or empty pipes must be laid in the cistern before tiling is begun.
3.1.2 Required material and tools
The following material is required for mounting:
na suitable flush plate
Ä„Suitable manual flush plates“ on page 8
nProgramming set
Ä„Optional accessories“ on page 16
nif necessary, empty pipe from power pack into the cistern
nif necessary, accessories for the extension of the system
ÄChapter
2.4.4 „System expansions“ on page 11
The following tools are required for mounting:
nflat screwdriver
nspanner (SW 19)
nknife (cutter)
External sensors (optional)
Material
Tool
Handling
WC flush actuation 19 from 42

3.2 Assembly
3.2.1 Mounting the power pack
DANGER!
Danger due to electrical current
An electric shock can lead to burns and serious injury and
even death.
– Only allow electrical work to be carried out by qualified
electricians.
– Always de-energise the connection cable before work is
commenced.
Requirements:
nA 230 V mains connection is available on site.
nThe installation position of the power pack complies with the require-
ments in acc. with
Ä„Installation position of the power pack“
on page 18
.
nThe connection cable is de-energised.
Remove approx. 1 cm of the insulation on the connection cable.
Push the connection cable into the terminals.
Handling
WC flush actuation 20 from 42
Table of contents
Other Viega Toilet manuals