6 of 6
INSTALLATION GUIDE
Rev 2 | Mar 2019 ©2019 View, Inc.
Step 5: Check Window Controller LED Indicators (IGU Cable Connection)
1. Wait about 10-15 seconds for the system to identify the IGU Cable. The Module LED
should start flashing blue indicating that it’s recognized the connection of the IGU.
2. The Network LED should stay a solid Blue.
Troubleshooting
LEDs do not illuminate
1. Check to ensure the Control Panel power is ON.
2. Check to ensure all connection points on the Trunk Line are connected properly.
3. Ensure all Power Insert Cables are installed completely
4. Ensure all Drop Cables and IGU Cables are installed completely and fully seated.
Network LED does not illuminate blue
1. Check to ensure the Control Panel power is ON.
2. Check to ensure all connection points back to the Control Panel are connected
properly.
Module LED does not illuminate blue
1. Ensure Network LED is operating properly.
2. Check to ensure the IGU Cable is connected to the IGU Smart Window Connector.