DefendRx® 5000
Electronic Air Purifier
Installation Instructions
•Turn OFF the POWER to the Furnace/Air Handler and Fanswitch.
•Open the door of the unit and remove the old pleated media(Fig.6).
•Position the new 5" replacement box such that the metal mesh on
media faces the metal screen of the cabinet, the end with a hole goes
in first, then push the box in strictly following the direction on labels
on the box, (Fig.7).
•Close the door (Fig. 4 and Fig. 5).
•Switch the Power back ON.
Fig. 6 Fig. 7
For Technical Assistance call: 1-800-565-5326
Low Pressure Filter Media DefendRx 5000 5”
OPERATION, INSTALLATION & MAINTENANCE
INSTRUCTION GUIDE
IMPORTANT: Please complete the information below and leave this
brochure with your customer after installation is complete.
INSTALLED BY:
Contractor Name & Phone No.:
PRODUCT INFORMATION:
MODEL: Viking DefendRx 5000 Electronic Air Purifier
FILTER SIZE:
INSTALLATION DATE:
5" Polarized-Media
Electronic Air Cleaner
WARNINGS
•The air filter is not energized in the absence of air flow in the HVACsystem.
•CAUTION - THE AIR CLEANER SHALL NOT BE INSTALLED IN A
SYSTEM WITH AIR FLOW LESS THAN 375 CFM, TO ENSURE OZONE
LEVELS ARE NOTEXCEEDED.
•THIS AIR CLEANER SHALL NOT BE INSTALLED ON THE HOT-AIR
SIDE OF DUCT-TYPE SYSTEMS.
•The POWER to the Furnace/Air Handler MUST BE TURNED OFF whenever
installing, removing, or replacing the MicroPower Guard air cleaner.
•Failure to change the Replacement Media on a 6-month Basis could reduce
airflow and cause damage to the heating and cooling system.
•Only qualified Electricians/HVAC Technicians should perform electrical wiring.
When non-original DefendRx filter media is used, no matter what the makers
claim, we are forced to decline your Lifetime Warranty.
This product complies with the maximum allowable concentration of ozone of 0.050 parts
per million by volume (ppmv) in a 24 h period. The Health Canada Guideline 2010
recommends that the maximum exposure limit, based on an averaging time of 8 hours, be
0.020 ppmv or less when tested in an ASHRAE 52.2 conforming test duct.
DEALER INSTALLATION GUIDE
Please read the DEALER INSTALLATION GUIDE carefully BEFORE
INSTALLING the Electronic Air Cleaner.
IMPORTANT
This unit is designed to operate from a SUPPLY OF 24 VOLTS AC AT
2VA.
DO NOT CONNECT TO 110 V AC POWER!
Connecting the DefendRx 5000 Electronic Air Purifier to a higher voltage
than specified may cause damage and/or failure of equipment.
ELECTRICAL HOOKUP: Most forced air heating or cooling systems, or
heat pumps, have an internal 24 V AC power source to which the MODEL
8000 ELECTRONIC AIR CLEANER can be safely connected without
overloading other circuits. CHECK if the system is protected by a low
voltage fuse and make sure connections are made on the FUSED SIDE. If
no fuse is present, a low-voltage in line fuse should be installed. BEFORE
connecting the unit to this power source, POSITIVELY identify that this IS
a 24 V (max 30 V) AC source, and not some other voltage. This is usually
best accomplished with a test meter.
NOTE: IF ONE TERMINAL OF POWER SOURCE IS GROUNDED,
HOOK THE SOLID BLACK WIRE TO THIS TERMINAL (C in Fig.1).
24 V AC POWER (FROM FURNACE CIRCUIT)
GROUND
24 VAC
R
C
W
G (FAN)
Y
Fig. 1
Connect the wire with black & white stripes to terminal G / FAN
(Fig.1) to ensure that the air cleaner is not energized in the absence
of air flow. Use a Voltmeter to confirm 24 volt (not 110 volt) on
unmarked terminals.
When wiring is completed, test the power by pressing the pushdown
switch (Fig.2) in the front of the cabinet. If there is power, the power
indicator (Fig. 3) will illuminate.
Fig. 2 Fig. 3
Next, insert the lower clips (Fig.4) of the door into the slots at the
bottom, then move the hook (A in Fig. 5) at the upper end over the
rim (B in Fig. 5) of the cabinet, and push it down till the rim gets all
the way into the hook.
Fig. 4 Fig. 5
Solid
Black
Black & White
Stripes

Other Viking Air Cleaner manuals

Viking A350 User manual

Viking

Viking A350 User manual

Viking KJ600 User manual

Viking

Viking KJ600 User manual

Viking DefendRx 1000 User manual

Viking

Viking DefendRx 1000 User manual

Popular Air Cleaner manuals by other brands

Silentnight ZERA-500 user manual

Silentnight

Silentnight ZERA-500 user manual

Daikin MC55YPVM Operation manual

Daikin

Daikin MC55YPVM Operation manual

Sharp KI-N51R Operation manual

Sharp

Sharp KI-N51R Operation manual

VOVO Imunsen M-003W user manual

VOVO

VOVO Imunsen M-003W user manual

Honeywell INSIGHT HPA080 Series user manual

Honeywell

Honeywell INSIGHT HPA080 Series user manual

Signature S40004N Your safety & instruction manual

Signature

Signature S40004N Your safety & instruction manual

Genano 525 manual

Genano

Genano 525 manual

WINFORM Trinity user manual

WINFORM

WINFORM Trinity user manual

HEXTIO Radic 8 USER GUIDE AND INSTRUCTIONS

HEXTIO

HEXTIO Radic 8 USER GUIDE AND INSTRUCTIONS

eBuddies HSAP001 instruction manual

eBuddies

eBuddies HSAP001 instruction manual

Sanyo VW-VF8AG Electrical wiring diagram

Sanyo

Sanyo VW-VF8AG Electrical wiring diagram

Safeology M Series operating instructions

Safeology

Safeology M Series operating instructions

Somogyi Elektronic Home Air 50 instruction manual

Somogyi Elektronic

Somogyi Elektronic Home Air 50 instruction manual

GOTEL LP-2202 operating instructions

GOTEL

GOTEL LP-2202 operating instructions

IQAir HealthPro Compact user manual

IQAir

IQAir HealthPro Compact user manual

AllerAir AirMedic+ Series Operation and maintenance manual

AllerAir

AllerAir AirMedic+ Series Operation and maintenance manual

Oregon Scientific WS907 user manual

Oregon Scientific

Oregon Scientific WS907 user manual

Luma AP170W owner's manual

Luma

Luma AP170W owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.