Printed in the U.S.A. Rev AFax Back Doc # 837
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking
Electronics, its affiliates and/or subsidiaries assume no responsibility for errors and/or omissions contained in this information. Revisions
of this document or new editions of it may be issued to incorporate such changes.
Product Support Line...(715) 386-8666 Fax Back Line...(715) 386-4345
5. Unprogrammed Memory Positions
Unused speed dial memory positions should be programmed to duplicate memory position 00.
6. Extension Numbers that Begin with a “0”
Callers that attempt to dial an extension number that begins with a “0” will be transferred to the extension number
programed into memory position 00.
7. Maximum Busy Extension Attempts
After three attempts to a busy extension, the caller will be transferred to the extension number programmed in
memory position 09.
B. Special Speed Dial Memory Positions
Memory position 08 can be used to store the appropriate Touch Tone code needed to re-access a call
transferred to a busy extension (see section E, DIP Switch Programming). This memory position may also be
used as a standard speed dial position if this feature is not required.
2. Memory Position 08
3. Memory Position 09
Memory position 09 is reserved for the extension a caller will default to if a Touch Tone code is not entered
during the “busy” announcement or within 2.5 seconds after. This memory position may also be used as a
standard speed dial position by dialing a 9.
4. Memory Position 00
Memory position 00 is reserved for the extension a caller will default to if a Touch Tone code is not entered
during the “answer” announcement or within 6 seconds thereafter. The ACA-1A can be forced to hang-up if no
selection is made by moving DIP switch 4 to the ON position (see section E).
C. DIP switch programming
Four DIP switches are provided on the back of the ACA-1A to program busy protocols, operational modes, etc.
Description
Hook flash to reaccess a caller attempting to transfer to a
busy extension
Hang up required to reaccess a caller attempting to transfer to
a busy extension
Hook flash and Touch Tone code, memory pos. 08, required to
reaccess a caller attempting to transfer to a busy extension
Double hook flash required to reaccess a caller attempting to
transfer to a busy extension
Switch 1
OFF
OFF
ON
ON
Switch 2
OFF
ON
OFF
ON
Description
Bilingual Mode
Normal Mode
ACA-1A drops the line if the caller does not make a selection
Normal operation
Switch
3
4
ON/OFF
ON
OFF
ON
OFF
CO/PABX
LINE
PROTOCOLS
1 2 3 4
1 2 3 4
Rear View of the ACA-1A
Memory position 07 can store up to 32 digits for international numbers or pager numbers.
1. Memory Position 07
USE ONLY LIMITED CLASS 2
POWER SOURCE
12V
0.5 A MAX
ON
OFF