Vision ZL 7261 CL-5 User manual

Federal Communications Commission Statement
This equipment has been followed to comply with Part 15 of the FCC Rules. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try and correct the
interference by one of the following measures:
-Reorient or relocate the receiving antenna,
-Increase the separation between the equipment and receiver,
-Connect the equipment into and outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesirable operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
Limited Warranty
Vision Guarantees that every wireless lighting module is free from physical defects in material
and workmanship under normal use for one year from the date of purchase. If the product
proves defective during this one-year warranty period, Vision will replace it free of charge.
Vision does not issue any refunds. This warranty is extended to the original end user purchase
only and is not transferable. This warranty does not apply to: (1) damage to units caused by
accident, dropping or abuse in handling, or any negligent use; (2) units which have been
subject to unauthorized repair, taken apart, or otherwise modified; (3) units not used in
accordance with instruction; (4) damages exceeding the cost of the product; (5) transit
damage, initial installation costs, removal cost, or reinstallation cost.
For information on addional devices, plesae visit us at www.visionsecurity.com.tw
Operation Manual
ZL 7261 CL-5
ZL 7261 CN-5
ZL 7261 DE-5
ZL 7261 FR-5
ZL 7261 IT-5
ZL 7261 JP-5
ZL 7261 KR-5
ZL 7261 RU-5
ZL 7261 US-5
Z-Wave Power Monitor
ZL7261-5
V0
1070301

Introduction
Thanks for choosing the Vision’s Power Monitor of the home automation device. This Power Monitor
Module is a Z-WaveTM enabled device (interoperable, two-way RF mesh networking technology) and is
fully compatible with any Z-WaveTM enabled network. Every main powered Z-WaveTM enabled device acts
as a signal repeater and multiple devices result in more possible transmission routes, which helps
eliminate “RF dead-sport”.
Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the
manufacturer, and ours can also be used in other manufacturer’s Z-WaveTM enabled networks. It will
send the energy consumption to the controller when it requests. With special design, this module won’t
interfere the other power outlet when plug into the AC outlet. This module acts as repeater. When the
device is secure included into Z-Wave network, above communication will be encrypted, ZD2112 supports
SECURITY S0 / SECURITY S2 UNAUTHENTICATED / SECURITY S2AUTHENTICATED.
Product Description and Specification
Specification:
Package Content:
Protocol: Z-WaveTM (ZM5202)
Frequency:
865.22MHz (ZD2112IN-5)
868.10MHz (ZD2112MY-5)
868.42MHz (ZD2112EU-5)
869.00MHz (ZD2112RU-5)
908.42MHz (ZD2112US-5)
916.00MHz (ZD2112IL-5)
920~923MHz (ZD2112KR-5)
919.80MHz (ZD2112HK-5)
922~926MHz (ZD2112JP-5)
921.42MHz (ZD2112BR-5)
Operating Temp. -15°C~ 60°C (-5°F~ 140°F)
Operating Voltage: AC 100V~230V
Operating Range: Up to 100 feet (about 30m)
Data Rate: Up to 9.6k/40k/100kbps
Application: Indoor use
Max Loading
Type B: 110V/15A/1600W (Resistive)
220V15A/3200W (Resistive)
Type E, F & L: 230V/10A/2300W (Resistive)
1pc Power Monitor f Module
1pc User Manual
Z-Wave™Command Class:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_METER_V5
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_SWITCH_BINARY (Mapping COMMAND_CLASS_BASIC_V2)
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
Z-Wave S2 Support Command Classes :
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_METER_V5
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_VERSION_V3
-2-
-1-
**For making better effect, please press the button as the direction of following diagram.

Operation
If you are installing the entire Z-WaveTM system for the first time, please refer to the installation guide of
Z-WaveTM Interface Controller before installing ZL7261.
1. LED Status:
After Power On, LED will keep flashing Red & Green if ZL7261 has not been included yet.
After Power On, LED will flash the color what power is loading if ZL7261 has been included.
Power Loading vs LED Color
LED Color
Plug Type E, F & L
Plug Type B
Green
0~3A
0~5A
Green+Red
3~7A
5~10A
Red
7A~
10A~
2. For “Inclusion”in (adding to) a network: Put the Z-WaveTM Interface Controller into “inclusion”mode,
and following its instruction to add the ZL7261 into your controller. To get in the “Inclusion”mode.
By power up to get included for first time, press the Program switch 3 times within 3 seconds to
be included.
For “Exclusion”from (removing from) a network: Set up the Z-Wave TM Interface Controller into
“exclusion”mode, and following its instruction to delete the ZL7261 from your controller. Press the
Program Switch 3 times within 3 seconds to be excluded.
For “Association”: the Z-WaveTM interface controller set “Association”, and following its instruction
to associate the ZL7261 with other device. Support one group (5 nodes). ZL7261 will report back
every time ON and OFF status and power consumption, also it will reports every notification to all
devices in the association group.
3. For “Meter Supported Get”: the Z-Wave TM Interface Controller or Gateway can send “Meter Get”
command with any of the following supported scales, and the ZL7261will report back with the energy
consumption values for the requested scale:
Scale: 0x00-kWh
0x01-kVAh
0x02-W (Default)
0X04-V
0X05-A
0X06-Power Factor.
4. Power Level Control:
* Use PowerLevel Set Command to set the RF strength during a specific period.
* Use PowerLevel Test Node Set Command to test the RF strength for specific node.
5. Manually turn the connected appliance On/Off by your controller or pressing the Program Switch.
This is toggle switch. If the connected appliance is OFF, pressing the Program Switch turns the
connected appliance ON and vice versa.
6. The on/off function uses the Z-Wave Switch Binary Command Class (or Basic Command Class) to
control its operation. Sending a switch binary set command with a level of 0 (0x00) will turn off the
device, and sending a level of 255 (0xFF) will turn on the device.
7. Repeater Function: This device acts as a repeater for the Z-Wave mesh network functionality.
8. Configuration:
Parameter
Size
Value
Notes
Auto report
timing
1
1 byte
1 ~ 120 minutess
(Default 1 minute )
Report
kWh/kVAh
Report when
Watt change
2
2 byte
5-3600 watt for Type B plug
5~2300 watt for all other plug
(Default 50 watt)
Report V.A.W
9. Support Meter Auto Report Function.
10. Overload Protection: If load is excess 15.5A for Type B plug or 10.5A for all others, then relay will
automatically cut off. To restore the relay, please power off & power on the device again.
11. Support SECURITY S0, SECURITY S2 UNAUTHENTICATED & SECURITY S2AUTHENTICATED.
12. Support SmartStart, please scan the QR Code from ZL7261 for SmartStart. The Z-Wave SmartStart
QR code is located on the body of the ZL7261DE-5 and is immediately above the text identifying the
Z-Wave Pin Code. Also, the full DSK can be only found on the additional card in the package
13. Reset: Press the Program Switch then power on (plug-in) and hold for 5 seconds before release the
switch. Only use this procedure when the primary controller is lost or otherwise inoperable. (Remark:
This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
14. Support OTA(Over-the Air) Firmware update from controller. Please refer to yourcontroller manual.
Once OTA function success, please make sure to exclude the device & include again before using
the device.
-1-
-3-
-4-
This manual suits for next models
8
Other Vision Measuring Instrument manuals