Vista QSW16 User manual

1
QSW16_24 User manual V1.0
QSW16_24
16 and 24 Chn PoE switch

2
QSW16_24 User manual V1.0
Before You Begin
Read these instructions before installing or operating this product.
Note: This installation should be made by a qualified service person and should conform to local codes.
This manual provides installation and operation information. To use this document, you must have the following minimum
qualifications:
• A basic knowledge of CCTV systems and components
• A basic knowledge of electrical wiring and low-voltage electrical connections
Intended use
Only use this product for its designated purpose; refer to the product specification and user documentation.
Customer Support
For assistance in installing, operating, maintaining and troubleshooting this product refer to this document and any other
documentation provided. If you still have questions, please contact Norbain Technical Support and Sales:
Norbain SD, 210 Wharfedale Road, IQ Winnersh, Wokingham, Berkshire RG41 5TP, England.
UK +44 (0) 118 912 5000
Note: You should be at the equipment and ready with details before calling Technical Support.
Conventions Used in this Manual
Boldface or button icons highlight command entries. The following WARNING, CAUTION and Note statements identify
potential hazards that can occur if the equipment is not handled properly:
* WARNING:
Improper use of this equipment can cause severe bodily injury or equipment damage.
* CAUTION:
Improper use of this equipment can cause equipment damage.
Note: Notes contain important information about a product or procedure.
This apparatus is manufactured to comply with the radio interference.
A Declaration of Conformity in accordance with the following EU standards has been made. The
manufacturer declares that the product supplied with this document is compliant the provisions of the EMC
Directive 2004/108/EC, the CE Marking Directive 93/68 EEC and all associated amendments.
All lead-free products offered by the company comply with the requirements of the European law on the
Restriction of Hazardous Substances (RoHS) directive: 2011/65/EU, which means our manufacture
processes and products, are strictly “lead-free” and without the hazardous substances cited in the directive.
The crossed-out wheeled bin mark symbolizes that within the European Union the product must be
collected separately at the product end-of-life. This applies to your product and any peripherals marked
with this symbol. Do not dispose of these products as unsorted municipal waste.
* This symbol indicates electrical warnings and cautions.
** This symbol indicates general warnings and cautions.
NORBAIN SD reserves the right to make changes to the product and specification of the product from time to time without
prior notice.

3
QSW16_24 User manual V1.0
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
.
WARNINGS AND CAUTIONS:
To reduce the risk of fire or electric shock, do not insert any metallic objects through the ventilation grills or other openings
on the equipment.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Clean only with dry cloth.
6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
7. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
8. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
9. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from
the apparatus.
10. Only use attachments/accessories specified by the manufacturer.
11. Unplug this apparatus during lightning storms or when unused for long periods of time.
12. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
13. CAUTION –THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY. TO REDUCE THE
RISK OF ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER THAN THAT CONTAINED IN THE OPERATING
INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO.
14. Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed Class 2 power source only.
15. ITE is to be connected only to PoE networks without routing to the outside plant.
CE COMPLIANCE STATEMENT
WARNING
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.

4
QSW16_24 User manual V1.0
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Contents
1.Introduction................................................................................................................................................5
1.1 Overview.............................................................................................................................................5
1.2 Product Features.................................................................................................................................5
1.3 Front panel..........................................................................................................................................5
2 Installation.................................................................................................................................................6
2.1 Contents .............................................................................................................................................6
2.2 Installation requirements.....................................................................................................................6
2.3 Rack mount.........................................................................................................................................6
2.4 Desk mount........................................................................................................................................7
2.5 Wall mounting.....................................................................................................................................7
2.6 Cable connections...............................................................................................................................8
2.6.1 Power connection.........................................................................................................................8
3.0Technical spec.....................................................................................................................................9

5
QSW16_24 User manual V1.0
1.Introduction
1.1 Overview
This manual covers the installation set up and use of the QSW16 and 24 PoE Switches
1.2 Product Features
•16 /24 100Mbps downlink PoE Ethernet ports, 2 x gigabit uplink ports and 1 gigabit fibre port
•PoE ports support PoE+ ( Max 30W per channel , total budget 180/270 W)
•CCTV Mode –Allows extended PoE and Data (up to 250M of cat5e cable)
•LED indication of Power consumption
•Standards: IEEE802. 3、IEEE802. 3u、IEEE802. 3ab、IEEE802. 3af/at
•4K MAC address, 2.75Mb cache
•Quick installation, easy operation, wall mount, desk or racks mount.
1.3 Front panel

6
QSW16_24 User manual V1.0
2 Installation
2.1 Contents
Please ensure that all items are present when un-packing the switch
2.2 Installation requirements
The switch should only be installed in an indoor environment , either in a rack mount cabinet, secured to a
wall or desk mounted. The following requirements should be observed:
•Leave a minimum of a 10cm air gap to allow sufficient ventilation
•The wall or cabinet should be of sufficient strength to support the switch
•The Cabinet should be well grounded
2.3 Rack mount
Installation process:
1. Check rack grounding and stability
2. Use the provided screws to fit the connection ears to the switch
3. Use the provided screws to fit the switch in the rack

7
QSW16_24 User manual V1.0
2.4 Desk mount
The Switch can simply be mounted on a desk or table top, please ensure the environment is stable and
clean.
If required the rack mount ears can be used to secure the switch to the desk top.
2.5 Wall mounting
The switch can be hung on a wall, please ensure the wall is of sufficient strength to support the switches
weight, and that the correct fixings are used for the wall construction.
Procedure:
1. Use the provided screws to fit the connection ears to the switch
2. Use the correct fixings for the wall construction to mount the switch to the wall

8
QSW16_24 User manual V1.0
2.6 Cable connections
2.6.1 Power connection
The switch requires 230VAC mains connection. Ensure the power supply conforms to this.
The AC power connection LED will show when power is applied.

9
QSW16_24 User manual V1.0
3.0Technical spec
Item
QSW16
QSW24
Port
Description
Downlink Ethernet Ports
16×RJ45,PoE+10/100Base-TX
24×RJ45,PoE+10/100Base-TX
Port
Description
Uplink Ethernet Ports
2*10/100/1000Base-T+1*1000Base-X(combo)
2*10/100/1000Base-T+1*1000Base-X(combo)
Port
Description
Power Input
1×AC Female Terminal
1×AC Female Terminal
Port
Description
Grounding Terminal
1×Grounding Terminal
1×Grounding Terminal
PoE&Power
Power Input
Mains on load,100~240VAC 50/60Hz
Mains on load,100~240VAC 50/60Hz
PoE&Power
PoE Power Supply
End-span(1/2,3/6),IEEE802.3 af/at
End-span(1/2,3/6),IEEE802.3 af/at
PoE&Power
PoE Max. Power budget
180W
270W
PoE&Power
Single Port Power Output&
Voltage
Single Port PoE Power Output≤30W,Voltage 54VDC
Single Port PoE Power Output≤30W,Voltage 54VDC
One-key CCTV
CCTV Mode
1. Downlink ports only communicate with uplink ports;
2. Restrain network storm under 2Mbps;
3.Extend transmission distance to 250m
1. Downlink ports only communicate with uplink ports;
2. Restrain network storm under 2Mbps;
3.Extend transmission distance to 250m
Network
Parameters
Network Standard
IEEE 802.3,IEEE 802.3u,IEEE 802.3 ab
IEEE 802.3,IEEE 802.3u,IEEE 802.3 ab
Network
Parameters
Transmission Distance
250m in CCTV mode
250m in CCTV mode
Network
Parameters
Exchange Capacity
7.2Gbps
7.2Gbps
Network
Parameters
Packet Transfer Rate
5.36Mpps
6.55Mpps
Network
Parameters
MAC Address
4K
4K
Network
Parameters
Packet Data Cache
2.75Mb
2.75Mb
Protection
Level
ESD
6KV/8KV, Per:IEC61000-4-2
6KV/8KV, Per:IEC61000-4-2
Surge Protection
6KV,Per:IEC61000-4-5
6KV,Per:IEC61000-4-5
Operation
Environment
Operation Temperature
-10℃~45℃
-10℃~45℃
This manual suits for next models
1
Table of contents
Other Vista Switch manuals