Vivax Metrotech vLoc3 Series User manual

On/Off button
Frequency selector
Info = Volume, Volts, Ohms,
multi-frequencies, LCD
contrast, frequency menu
Output decrease
Output increase
Transmitter Keypad (Loc3 series transmitters)
1 3
4 5
21
2
3
4
5
Locating Utilities**
Passive location Power 60Hz and Radio
(No compass indicator is available in Power 60Hz or Radio
Modes) All other Passive locate modes will show the Compass
line direction indicator. And left/right arrows as seen in the Classic
Locate Mode section of this document.
Select the passive frequency with the "f"-button. (If the desired
frequency is not preset, switch to the user menu by pressing
and holding the "i"-button and choose it in the sub-menu
"frequency." Press the "Enter" button to highlight it. Go back
with a short press on the "i" button.)
Hold the receiver vertically and adjust the sensitivity by
pressing the "+" / "-" buttons so that the bar graph shows a
signal.
Continue locating in a grid across the area. See illustration (a)
below.
Determine signal maximum by carefully moving the receiver
back and forth. Adjust the sensitivity again with the "+" "-"
buttons.
Continue to locate the position of the line.
1.
2.
3.
4.
5.
(a) (b)
Power 5031dB
94.4
94.4
Power 5031dB
12.1
Power 5031dB
Switch on the transmitter and select the desired frequency
with the "f" button (If the frequency is not present, use the "i"
key to access "frequency selection" in the menu and mark the
desired frequency with the "f" key. Press the "i" key to return.
Always select the lowest possible frequency to minimize
coupling to other lines.
Set the output power accordingly. (less is more)
From this point on, follow points 1 through 6 of the Passive
location 60Hz / Radio / CTV section of this document.
1.
2.
3.
Connect the transmitter with the supplied connection leads. Connect
the red wire to the target conductor and the black wire to ground. The
ground stake should be at a 90o angle to the target line if possible. To
help reduce signal interference, there should be no other lines (if
possible) between the ground spike and the target line.
Active locating
Direct connection**
Connect the signal clamp to the transmitter and place it around the
corresponding target line.
Then follow points 1 - 3 from the Direct connection section of this
document.
Signal clamp** (Frequencies above 8kHz):
Place the transmitter (without connection leads or clamp attached)
on the ground with the handle in the cable's direction. Do not place
the transmitter on manhole covers or other metallic objects as the
signal will not be able to penetrate them. When locating, maintain
a distance of at least 50ft from the transmitter. Otherwise, the
airborne signal from the transmitter will be located and not the
target line. Now follow points 1 through 3 in the Direct Connection
section of this document.
Induction** (Frequencies above 8kHz):
1
2
3
4
5
6
On/Off button
Reduce sensitivity (scroll up when in the user menu)
Frequency selector
Increase sensitivity (scroll down when in the user menu)
Short press = Change between Peak, Null, Sonde, etc.
Long press = Change operational screen
Short press = Enter information screen (Depth/Current/GPS)
Long press = Enter user set-up menus
1
2
3
4
5
6
7
8
Pushbutton keypad & display
Model & Serial numbers
Battery retaining clip
Battery compartment - Li-ion
or Alkaline battery packs
Mini-USB Port for data transfer
and firmware updates
Battery compartment cover
Accessory socket and
charging port
Bluetooth module expansion
port
vLoc3 Series Receivers - Overview
Receiver Keypad
vLoc3 Series Quick guide* V1.1
(vLoc3-Pro, vLoc3-5000, vLoc3-ML, vLoc3-XLF)
1
2
3
4
5
6
78
1 2 543
6
www.vivax-metrotech.com
1 2 3P/N: 4.04.000204

Vivax-Metrotech Corp. (Headquarters)
3251 Olcott Street, Santa Clara, CA 95054, USA
T/Free: 1-800-446-3392 Tel: +1-408-734-1400 Fax: +1-408-734-1415
Visit us at www.vivax-metrotech.com to view our full product line and worldwide locations.
1
2
3
4
5
6
7
8
Percentage signal strength
Peak level indicator
Gain setting
Bar graph signal strength indicator
Signal direction (SD) forward/backward arrows
Compass line direction indicator
Left/Right direction to target line indicators
Frequency selection
2Frequency selectedDepth and current readings
Target line
Lines of confidence (closer these are to the target line indicates
more confidence)
Arrow indicates the direction to move towards the line.
1
3
4
5
Plan View (Refer to the vLoc3 Series manual)
Shows a picture as if you were viewing the line from above the ground.
Advantages: Automatic gain adjustment; easy finding/routing of lines with
the 3D mode.
Advantages: Automatic gain adjustment; line depth is permanently
measured, even when running offset to the line.
Vector Screen (Refer to the vLoc3 Series manual)
Shows a cross-sectional view through the ground.
8.19kHz
1.43m
1.86m
0 2m
85.6mA
3
21
6
7
4
5
14’5’’
4
3
2
1
12.9mA 32.8kHz
5
14’5’’
12.9mA 32.8kHz
1
3
4
5
6
7
Frequency selected
Vertical distance to the target
Horizontal distance to the target
Scaling (adjust with +/- keys)
Shows plan view of the target
Cross-section view that shows vectors to target
Signal current
2
Classic locate modes (refer to the vLoc3 Series manual)
Available modes: peak, peak with arrows, null, broad peak, delta
null, omni direction.
The individual modes within the classic view can be changed by a
short press (<1 sec.) on the "Enter" button. If a mode is not visible
or not desired, it can be switched on or off in the user menu (long
press on the "i" key / classic display/selection with "Enter" key).
Locate Screens**
For all subsequent locating views, except Transverse Graph
and Sonde Mode:
The distortion level is displayed on the bar graph.
Green = low interference, Blue = some interference, and Red = high
interference level, treat the locating results with caution.
NOTE:
Locating views (classic, vector, plan view,
transverse graph, and sonde can be changed by a
long press on the "Enter" key (approx. 2 seconds).
Antenna
configuration:
50ft
(20m)
dd
0.39m
18.3
17dB 116mA
SD-USA
3
21
4
567
8
Peak
Null
Delta-Null
Peak with arrows
Broad peak
Omni direction
If the signal path is distorted, or the two signal peaks are not on the
centerline, there is interference in the electromagnetic field. To
determine the cable's exact position now, please refer to the user
manual, section "Distorted fields."
Advantages: Automatic gain adjustment; Optimal analysis of signal distortion.
Peak signal detector
Signal strength bar graph
Sonde icon
Null point
Direction to sonde
Frequency selection
Numeric signal level
Gain setting
1
2
3
4
5
6
7
8
Bar graph gain setting
Signal strength from marker
Marker detection ball
Marker type graphic
Numeric value of bar graph
Peak level indicator
Marker icon
1
2
3
4
5
6
7
Sonde Location Mode (Refer to the vLoc3 Series manual)
Locating non-metallic pipes with a sonde.
67.2
25dB
8kHz
22
3 4 5
6
8 7
1
*
**
Observe the manual's safety instructions regarding handling the
devices, measurement results, and Li-ion batteries!
Read the exact settings, evaluations, and safety instructions for
locating in the user manual!
Advantages: Simple marker location with immediate depth measurement at
the push of a button. For more details on the dual-mode with parallel line and
marker location, please refer to the user manual.
Marker detection - Pinpointing EMS Markers
Valid for vLoc3-ML or vLoc3 receiver with vLoc3-MLA attached.
19.1
12dB
1
2
34
7 6 5
The target line is below the receiver
when both signal peaks are on the
center line and the signal is not distorted.
The centerline does not indicate the
target line but serves as an orientation
for the two signal peaks and the cable's alignment!
3’9”
33dB 14.1mA 8.19kHz
Transverse Plot Screen (Refer to the vLoc3 Series manual)
Analyze the field shape at a particular location.
Signal overload - When the receiver is too close to the
inductive operated transmitter or a power transformer.
Shallow cable - When the cable is possibly less than 6-inches
deep. Proceed with caution!
Swing alert - When excessively swinging the receiver. Doing
so could result in misleading information.
Overhead cable - When the signal is mainly radiating from
above distorting the below-ground signal.
Warnings - Are audible sound with a vibration of the handle. Warnings
can be activated or deactivated in the user menu.
4 5
www.vivax-metrotech.com
6
NOTE
Other manuals for vLoc3 Series
7
This manual suits for next models
4
Other Vivax Metrotech Receiver manuals

Vivax Metrotech
Vivax Metrotech vLoc3-Pro Instruction Manual

Vivax Metrotech
Vivax Metrotech vLocCam2 User manual

Vivax Metrotech
Vivax Metrotech vLoc3 Series User manual

Vivax Metrotech
Vivax Metrotech vLoc3-DM Instruction Manual

Vivax Metrotech
Vivax Metrotech vLoc-5000 Instruction Manual

Vivax Metrotech
Vivax Metrotech vLoc3-Pro Installation guide

Vivax Metrotech
Vivax Metrotech vLoc3-Pro Instruction Manual

Vivax Metrotech
Vivax Metrotech vLoc3 Series User manual

Vivax Metrotech
Vivax Metrotech vLoc3 Series Instruction Manual