viveroo level User manual

Installation Guide level
Content
-Installation instructions for MountingSet Inwall (pp. 2-5)
-Installation and milling dimensions for wall installation (pp. 6-7)
-Assembly instructions MountingSet Inwall zero (pp. 8-11)
-Installation and milling dimensions for furniture installation (pp. 11-12)

Installation Guide
MountingSet Inwall for level
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von212
viveroo GmbH
Wewelsburger Straße 4
33154 Salzkotten
Germany
www.viveroo.de
REV20211014

Safety information
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von312
!
! WARNING
Please read the assembly instructions included carefully. Please
read this level user manual completely before using your level.
Please follow the instructions and recommendations to ensure
proper use and maximum enjoyment.
Safety
information
level and all level mounting sets are intended for use in enclosed
and dry living spaces.
The following conditions must be provided:
- Operating temperature between 0° C (32° F) and 35° C (95° F).
- Relative humidity (during use): 20 % to 90 %, non-condensing.
- No external environmental influences such as oil, chemicals, salt,
extensive dust, etc.
The maximum altitude is 2.000m.
Installation, service or repairs, if necessary, may only be performed
by authorized persons.
The installer is responsible for selecting the proper mounting
location and safe installation of level. This also applies to
installation in movable parts, such as doors. The installer is
responsible for performing and documenting all necessary safety
tests.
All electrical installation work may only be conducted by
authorized, trained electricians, always adhering to the general
rules and regulations applying to electrical installation. Wire end
sleeves and ferrules must be used for flexible cables.
Should it become apparent that safe operation of level is not
assured, then level must immediately be taken out of service and
secured against potential misuse. If the level functions are limited,
blocked or disabled, if an unusual odor is present, if noises such as
scratching are audible or damage is visible, safe operation can no
longer be guaranteed.

Technical Data
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von412
Product
contents
-User manual level
-level
Please note! External cable, power supply and mounting screws
are included in level MountingSet.
Compatability
Electrical operation of level is permitted only in connection with
level MountingSet and power supply and cable included in the
Mounting Set. Operation of level without a MountingSet will lead to
immediate loss of guarantee and warranty.
Measurements
Measurements design cover
364 x 294
Depth level
36
Size of opening (for furniture installation)
Size of opening (for flush-mounted box)
367 x 296,5
344 x 271
Installation depth (for furniture installation)
Installation depth (for flush-mounted box)
20
76
Weight in kg
level
3,8
Electrical
connections
Low voltage
Power consumption
12 Vdc
18 Watt
Removal from
power supply
level may be removed from the power supply via the circuit breaker
in the respective rooms.
Circuit Breaker
16A (EU) , 20A (USA/Canada)
Overvoltage
category
OVC II
wire cross-
section
The permitted conductive cross-section is between 0.75mm²and
2.5mm².
CE & Co.
All levels have CE certification. level is quality "Made in Germany".
We use only high quality parts and components produced by
market leaders. level customers are proud of their iPad Garage.
Technical changes and mistakes are excepted.
iPad is a registered trademark of Apple Inc.

Installation
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von512
Verformung der UPD
Step 1
square can be installed either in portrait or landscape
format, it is your choice. Make an angular opening in the
wall.
Measurements for portrait: 271mm length, 344mm height.
Measurements for landscape: 344mm length, 271mm
length.
The depth should be approximately 75mm. In this guide we
show the installation for mounting in landscape.
Step 2
There is a hole for the power cable already cut in the flush
mount box. Pull 20-25 cm of the cable through the opening.
Step 3
Then insert the flush mount box into the opening in the wall.
Fix and secure the box with the four pre-installed screws in
the corners.
! IMPORTANT: During installation, pay attention that the
flush mount box is fastened parallel to the surface and is
not shifted or offset in the wall.
! IMPORTANT: It is important that the flush mounted box is
not deformed in any way. Do not use any foaming
installation materials that may put pressure on the box and
deform it.
!! WARNING: Make sure that the power supply cord is
unplugged during the entire installation and cannot be
turned on accidentally.
Step 4
Plug the power cord into the power supply. Plug the power
cord into the 3-pin device connecting terminal (N, L, PE).

Technical Details
square
Measurements for installation in drywall, stone or solid wall
(with wallbox), in mm
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von612

Fräsmaße für den Einbau in Mauerwerk, Beton und Hohlwand
(für Unterputz-Hohlwanddose), in mm
! Hinweis: Einbau sowohl im Hoch- als auch im Querformat möglich! Diese Zeichnung zeigt
exemplarisch den Einbau im Hochformat.
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von712

MountingSet Inwall zero square
Incl. MountingSet Inwall + flush mount frame with reinforcing grid
Safety informaion
! Important:
Before installing this MountingSet please read the following information. Follow the instructions and recommendations
described.
General conditions:
The MountingSet Inwall zero is an extension of MountingSet Inwall. Accordingly, it is assumed that both products are built
in combination.
The following embedding materials are approved for the attachment and incorporation of MountingSet Inwall zero: mineral
plaster, polymer modified adhesive and reinforcement cement.
The MountingSystem is designed for installation in dry and closed living spaces.
The following environmental conditions are ensured:
Ambient temperature 0 °C to 35 °C
No environmental influences, such as oil, chemicals, salt and comparable
No direct sunlight
The MountingSet must be processed and installed only by authorized personnel. This includes the proper installation of
electrical connections. The responsibility for proper installation and safe installation of the mounting system is only with
the processor. Basically, the user has to make and certify all safety checks.
Delivery contents
- Installation guide, flush-plastered MountingSet Inwall zero
- Flush mount frame with reinforcing grid
Installation in hollow walls (plasterboard)
Make an angular opening in the wall: Measurements for portrait: 271mm length, 344mm height. Measurements for
landscape: 344mm length, 271mm length. The depth should be approximately 76mm. Place the power cable.
Clean the surface of the gypsum board thoroughly and fix the flush mount frame on the gypsum fibreboard - pay attention
that the flush mount box is fastened parallel to the surface and is not shifted or offset in the wall.
! Important: The gypsum fibreboard must provide a very smooth, surface adhesion for the flush mount frame, stress-
and distortion-free!
Incorporate the flush mount frame with approved embedding material (see above). To do this, prepare the surface
according to VOB, Section C, DIN 18363, DIN 18350 or BFS notices. Then apply the embedding material evenly to the
gypsum fibreboard according to the manufacturer's instructions. Embed the reinforcement fabric of the frame in the wet
coating without any creases. After that apply embedding material again evenly, so that the grid is no longer visible.
Depending on the design ideas the flush mount frame can be plastered up to the upper edge.
After the embedding material has perfectly dried out, please clean the inner surfaces of the frame and insert the wall
case / flush mount box. Please follow the installation guide for the MountingSet Inwall.
! Attention: Install the flush box so deep that it rests firmly on the inner ring of the frame.
! Attention: Screw the wall case / flush mount box so tight that it stabilizes the frame.
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von812

MountingSet Inwall zero square
Incl. MountingSet Inwall + flush mount frame with reinforcing grid
REV20180809
Installation in brick walls and concrete walls (shell)
Make an angular opening in the wall: Measurements for portrait: 271mm length, 344mm height. Measurements for
landscape: 344mm length, 271mm length. The depth should be approximately 76mm. Place the power cable.
Apply subsoil / substrate plaster to the wall and fix the flush mount frame - pay attention that the flush mount box is
fastened parallel to the surface and is not shifted or offset in the wall.
! Important: The subsoil / substrate plaster must provide a very smooth, surface adhesion for the flush mount frame,
stress- and distortion-free!
Incorporate the flush mount frame with approved embedding material (see above). To do this, prepare the surface
according to VOB, Section C, DIN 18363, DIN 18350 or BFS notices. Then apply the embedding material evenly to the
gypsum fibreboard according to the manufacturer's instructions. Embed the reinforcement fabric of the frame in the wet
coating without any creases. After that apply embedding material again evenly, so that the grid is no longer visible.
Depending on the design ideas the flush mount frame can be plastered up to the upper edge.
After the embedding material has perfectly dried out, please clean the inner surfaces of the frame. Insert the wall case /
flush mount box and fix it with fastening material such as plaster or mortar or cement – Please follow the installation
guide for the MountingSet Inwall.
! Attention: Install the flush box so deep that it rests firmly on the inner ring of the frame.
! Attention: Screw the wall case / flush mount box so tight that it stabilizes the frame.
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von912

Images for Illustration
Information:
Follow sequence: 1. Flush Mount Frame, 2. Installation Box, 3. level
Install the flush box so deep that it rests firmly on the inner ring of the frame.
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von10 12

MontageSet Furniture for level
Technical Details
level
Measurements for installation in furniture, cabinets, wooden
materials, in mm
Einbau- und Fräsmaße
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von11 12
20
7

level
Measurements for installation in furniture, cabinets, wooden
materials, in mm
Installation Guide level, Inwall, Inwall zero and Furniture, Seite von12 12
13
Other manuals for level
1
Table of contents
Other viveroo Rack & Stand manuals
Popular Rack & Stand manuals by other brands

Bogen
Bogen TS-70GB product manual

WE-EF
WE-EF FLD111 Installation and maintenance instructions

New Star Computer Products
New Star Computer Products FPMA-D935GROMMET instruction manual

peerless-AV
peerless-AV DS-S555-4X2 manual

peerless-AV
peerless-AV DS-VW765-PQR manual

CommScope
CommScope 639849 instruction sheet