VOKERA RC05 User manual

Installation
Instructions
THESE INSTRUCTIONS
TO BE RETAINED
BY USER
RC05
Programmable room thermostat

INSTALLATION INSTRUCTIONS FOR RC05
CONTENTS
Installation instruction
Instructions for use
RC05 panel
Fixing screws and wall plugs
INTRODUCTION
The Vokera RC05 remote control enables full control
of the Linea, Compact and Hydra range of boilers.
The RC05 can also be used as a programmable room
thermostat and has a facility for the connection of an
external temperature sensor.
INSTALLATION REQUIREMENTS
To enable the correct functioning of the RC05, the
following instalaltion requirements must be adhered to:
the installation of the RC05 and the external sensor
(if required), must only be carried out by suitably
qualified personnel
the sensor should be mounted on an internal wall
away from any source of heat and/or confined
space (fig. 1)
the connecting cable length between boiler and
control panel should not exceed 50-metres
ideally, the RC05 should be mounted directly to a
single-gang box. The RC05 can also be wall-
mounted, however tha cabling will require to be
flush with the finished wall surface as the RC05 is
not suitable for surface wiring
all wiring between the RC05 and the appliance must
conform to BS6500 and sized from 0.5 to 1.0mm2
the RC05 should be mounted approximately 1.5-
metres above floor level
the RC05 when used with an external sensor, may
not be suitable for systems that incorporate fan
warm air heaters.
fig. 1
1. INSTALLATION OF RC05 (fig’s. 2, 3 & 4)
Remove the RC05 from the packaging and detach
the panel from it’s wall mounting plate.
Using the wall mounting plate as a guide, mark the
position of the fixing holes on the chosen location for
the RC05.
Drill two 6mm-diameter holes at the previously
marked positions on the wall.
Route the wiring through a suitable cable entry point
ensuring that the wiring does not become trapped.
Using the screws and wall plugs provided, secure
the mounting plate to the wall.
fig. 2
fig. 3
fig. 4
1,50 m
NO
NO
SI
YES
NO
NO

INSTALLATION INSTRUCTIONS FOR RC05
2. WIRING CONNECTIONS (Linea)
Isolate the appliance from the electrical supply and
remove the appliance casing and input PCB cover
(fig. 3 & 4). Refer to the installation instructions for
details. Connect a suitable cable between te S & -
terminals of the RC05 and the S & - terminals of the
control PCB (see fig.5). Remove the link-wire (if fitted)
between terminals TA & TA of the control PCB.
Refer to paragraph 4.2 if an external sensor (part no.
2359259) is also being connected.
Once the wiring connections have been completed
re-attach the RC05 to the wall mounting plate.
The PCB cover and appliance casing can now be
refitted.
2. WIRING CONNECTIONS (Hydra)
The RC05 must be used with the Hydra remote
control interface (part no.410). Carry out the
installation of the interface as detailed in the
instructions supplied.
Connect the RC05 to the remote control interface as
shown in fig. 6.
If an external sensor (part no. 2359259) is also being
connected, refer to the instructions supplied with the
sensor.
Once the wiring connections have been completed
re-attach the RC05 to the wall mounting plate.
3. WIRING CONNECTIONS (Compact)
The RC05 must be used with the Compact remote
control interface (part no.409). Carry out the
installation of the interface as detailed in the
instructions supplied.
Connect the RC05 to the remote control interface as
shown in fig. 7.
Refer to paragraph 4.2 if an external sensor (part no.
2359259) is also being connected.
Once the wiring connections have been completed
re-attach the RC05 to the wall mounting plate.
4. ADDITIONAL FUNCTIONS
The RC05 is equipped with additional functions.
These functions enable the RC05 to be used with an
external sensor, underfloor heating systems and
calibration of the unit.
F1 - Frost Protection Circuit. When enabled, this
function will allow a heat request should the room
temperature (the room in which the RC05 is
located) drop below 6.6°C.This function is not active
when the RC05 is used for boiler only control.
F2 - Thermo-regulation. When enabled, this
function automatically adjust the outlet flow
temperature based on the current temperature of
the external sensor.
F3 - Under-floor heating. When enabled, this
function fixes the maximum flow outlet temperature
to 40.0°C.
F4 - Service Scheduling. When enabled, this
function will alert the end-user that the appliance
requires it’s annual service.
F5 - Internal Sensor Calibration. Used to calibrate
the indoor sensor.
F6 - External Sensor Calibration. Used to calibrate
the exteral sensor (Linea/Compact only).
F7 - Alarm History. Used to display the last 5 alarm
codes generated by the boiler.
fig. 6
fig. 7
fig. 5
Hydra remote control interface
Compact remote control interface

INSTALLATION INSTRUCTIONS FOR RC05
4.1 ENABLING/DISABLING ADDITIONAL
FUNCTIONS
To access the RC05 additional functions, set the
control to the OFF position (see fig. 8).
Press and hold the PROG button for 10-seconds, F?
will now appear on the display (see fig. 9).
To access the functions press ENTER within 10-
seconds (see fig. 10).
Use the ENTER button to scroll to the required
function (F1 to F7). Use the +/- buttons to enable (1)
or disable (0) the selected function (F1 to F3), to set
the service schedule (F4) or to calibrate the sensors
(F5 & F6).
fig. 8
fig. 9
fig. 10
Function Default setting
F1 (0 or 1) Enabled (1)
F2 (0 or 1) Disabled (0)
F3 (0 or 1) Disabled (0)
F4 (up to 365 days) 365 (days)
F5 (-3°C to +3°C) 0 (actual)
F6 (-3°C to +3°C) 0 (actual)
F7 (last 5 records) - - (no record)
4.2 EXTERNAL SENSOR
When the external sensor is connected to the RC05
(Linea & Compact only) a temperature curve can be
set to suit the system and location (fig. 13). Connect
the sensor to the EXT terminals of the RC05 (see
fig. 11).
Use the water temperature and +/-adjustment
buttons to select and store the required curve (fig.
12). Curve ‘C5” is the default setting.
5. REPLACING THE BATTERY
The RC05 is supplied with long-life battery (CR1220)
that is already inserted and activated. The battery
should last for approximately 4-years.
Should it be necessary to replace the battery, the
following procedure should be used:
isolate the appliance from the electrical supply
remove the RC05 control panel from its wall-
mounting plate
*remove the jumper tag from JP1
*remove the battery from its location and *insert
the new battery (observing correct polarity)
*refit the jumper tag to JP1
refit the RC05 control panel to the wall-mounting
plate
restore the electrical supply.
fig. 11
fig. 12
RC05 Wall-mounting plate

INSTALLATION INSTRUCTIONS FOR RC05
Cod.10024478 - Ed.1 - 06/03
TEMPERATURA ESTERNA IN °C
TEMPERATURA DI MANDATA IN °C
20,0
30,0
40,0
50,0
60,0
70,0
80,0
90,0
100,0
C0
C1
C2
C3C4
C9 C5
C6C7C8
fig. 13

Registered address:
Vokèra Ltd
Borderlake House
Unit 7 Riverside Industrial Estate
London Colney
Herts AL2 1HG
www.vokera.co.uk
www.vokera.ie
Sales, General Enquires
T0844 391 099
F0844 391 0998
Vokèra Ireland
West Court, Callan
Co Kilkenny
T056 7755057
F056 7755060
Vokèra Limited reserve the right to change
specification without prior notice
Consumers statutory rights are not affected.
A Riello Group Company.
Company Reg No: 1047779
Cod.10024478 - Ed.1 - 06/03
Other manuals for RC05
1
Table of contents
Other VOKERA Thermostat manuals
Popular Thermostat manuals by other brands

Warmup
Warmup Terra user guide

Honeywell
Honeywell RTH111 series Quick installation guide

Honeywell
Honeywell PRO TH2000DV Series installation guide

oventrop
oventrop R-Tronic installation guide

Synapse
Synapse CONTROL-485-101 quick start guide

Neptronic
Neptronic TMA54-EXT1 Specification & installation instructions