INSTALLATION INSTRUCTIONS FOR RC05
2. WIRING CONNECTIONS (Linea)
Isolate the appliance from the electrical supply and
remove the appliance casing and input PCB cover
(fig. 3 & 4). Refer to the installation instructions for
details. Connect a suitable cable between te S & -
terminals of the RC05 and the S & - terminals of the
control PCB (see fig.5). Remove the link-wire (if fitted)
between terminals TA & TA of the control PCB.
Refer to paragraph 4.2 if an external sensor (part no.
2359259) is also being connected.
Once the wiring connections have been completed
re-attach the RC05 to the wall mounting plate.
The PCB cover and appliance casing can now be
refitted.
2. WIRING CONNECTIONS (Hydra)
The RC05 must be used with the Hydra remote
control interface (part no.410). Carry out the
installation of the interface as detailed in the
instructions supplied.
Connect the RC05 to the remote control interface as
shown in fig. 6.
If an external sensor (part no. 2359259) is also being
connected, refer to the instructions supplied with the
sensor.
Once the wiring connections have been completed
re-attach the RC05 to the wall mounting plate.
3. WIRING CONNECTIONS (Compact)
The RC05 must be used with the Compact remote
control interface (part no.409). Carry out the
installation of the interface as detailed in the
instructions supplied.
Connect the RC05 to the remote control interface as
shown in fig. 7.
Refer to paragraph 4.2 if an external sensor (part no.
2359259) is also being connected.
Once the wiring connections have been completed
re-attach the RC05 to the wall mounting plate.
4. ADDITIONAL FUNCTIONS
The RC05 is equipped with additional functions.
These functions enable the RC05 to be used with an
external sensor, underfloor heating systems and
calibration of the unit.
F1 - Frost Protection Circuit. When enabled, this
function will allow a heat request should the room
temperature (the room in which the RC05 is
located) drop below 6.6°C.This function is not active
when the RC05 is used for boiler only control.
F2 - Thermo-regulation. When enabled, this
function automatically adjust the outlet flow
temperature based on the current temperature of
the external sensor.
F3 - Under-floor heating. When enabled, this
function fixes the maximum flow outlet temperature
to 40.0°C.
F4 - Service Scheduling. When enabled, this
function will alert the end-user that the appliance
requires it’s annual service.
F5 - Internal Sensor Calibration. Used to calibrate
the indoor sensor.
F6 - External Sensor Calibration. Used to calibrate
the exteral sensor (Linea/Compact only).
F7 - Alarm History. Used to display the last 5 alarm
codes generated by the boiler.