Vtronix LAKEPRO-1 User manual

LAKEPRO-1 WI-FI TOUCHSCREEN
PROGRAMMABLE THERMOSTAT

Contents
APPLICATION................................................................................................................................ 1
FEATURES....................................................................................................................................... 2
SPECIFICATIONS......................................................................................................................... 3
INSTALLATION..............................................................................................................................5
WIRING..........................................................................................................................................13
POWERING UP THE THERMOSTAT..........................................................................................30
INSTALLER SETUP.................................................................................................................... 33
OPERATION...................................................................................................................................44
PROGRAMMING A SCHEDULE................................................................................................... 66
FCC Note..................................................................................................................................... 71
TROUBLESHOOTING.................................................................................................................... 73


1
APPLICATION
The Lakepro-1 Wi-Fi touchscreen programmable thermostat is an easy to use 7-Day
programmable thermostat that provides universal system compatibility, precise comfort
control and ease of programming.
The Lakepro-1 provides temperature control for gas, oil, electric conventional systems
and heat pumps for up to 3 heat stages and 2 cool stages.
Above all, it allows you to remotely monitor and control the heating and cooling system in
your home or business — you can stay connected to your comfort system wherever you
go.

2
FEATURES
·Large, clear display with backlight shows room temperature, set temperature and
humidity.
·Menu-driven programming makes for easy setup.
·Capacitance touchscreen interaction.
·Optional connection to the Internet to monitor and control the heating/cooling system
remotely.
·Compressor protection.

3
SPECIFICATIONS
Temperature Setting Range:
Heating: 40°F to 90°F (4°C to 32°C).
Cooling: 50°F to 99°F (10°C to 37°C).
Operating Ambient Temperature:
32°F to 122°F (0°C to 50°C).
Shipping Temperature:
14°F to 140°F (-10°C to 60°C).
Temperature Accuracy:
±2℉.
Operating Relative Humidity (Non-condensing):
5% to 95%.
Humidity Display Range:
0% to 99%.
Humidity Accuracy:
+/- 10%RH.
Clock Accuracy:
+/- 2 minutes per month.
Cool Indication:

4
Displays "Cool On" on the screen when Cool is activated.
Heat Indication:
Displays "Heat On" on the screen when Heat is activated.
Auxiliary Heat Indication:
Displays "Aux On" on the screen when Auxiliary Heat is activated.
Emergency Heat Indication: (heat pump with backup heat only)
Displays “Emer” on the screen when Emergency Heat is manually activated.
Automatic Changeover Indication: (when enabled)
Displays “Auto” when Automatic Changeover (Heat/Cool) is activated
System OFF Indication:
Displays “OFF” when system is turned OFF.

5
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow the instructions can damage the
product or cause a hazardous condition.
2. Check the ratings given in the instructions to make sure the product is suitable for
your application.
3. The installer must be a trained, experienced service technician.
4. After completing the installation, use these instructions to check out the operation of
the product.
Selecting Location
Install the thermostat about 5 feet (1.5m), above the floor in an area with good air
circulation at average temperature. See Fig.4.
Do not install the thermostat where it can be affected by:
---Drafts or dead spots behind doors and in corners.
---Hot or cold air from ducts.
---Radiant heat from the sun or appliances or concealed pipes and chimneys.
---Unheated or uncooled areas such as an outside wall behind the thermostat.
Mounting Means:
Mounts directly on the wall in the living space using mounting screws and anchors
provided or on a horizontal 2x4 electrical box.

6
Dimensions:
1. Lakepro-1 front and side dimensions: see Fig. 1.
2. Lakepro-1 rear dimensions: see Fig. 2.
3. Lakepro-1 wall plate dimensions: see Fig. 3.
Fig. 1. Lakepro-1 front and side dimensions in inches. (mm).

7
Fig. 2. Lakepro-1 rear dimensions in inches. (mm).

8
Fig. 3. Lakepro-1 wall plate dimensions in inches. (mm).

9
Fig.4. Selecting the thermostat location.

10
Installing the Wall plate
CAUTION
Electrical hazard! Can cause electrical shock or equipment damage. Disconnect
power before wiring.
The thermostat should be mounted horizontally on the wall.
If mounting on dry wall:
1. Position and level the wall plate on the wall.
2. Use a pencil to mark the inner mounting holes.
3. Remove the wall plate from the wall and drill two holes in the wall as marked. Gently
tap the anchors (provided) into the drilled holes until flush with the wall.
4. Position the wall plate over the holes, pulling wires through the wiring opening. See
Fig.5.
5. Insert the mounting screws (provided) into the holes and tighten.
If mounting on a horizontal 2x4 electrical box:
1. Align the outer holes with the holes on the electrical box.
2. Insert machine screws (not provided) into the holes.
3. Pull wires through the wall opening.
4. Level the wall plate and tighten the screws.

11
Note: If you are mounting on a vertical 2x4 electrical box or on a 4x4 electrical box you
will need to purchase an adapter ring.

12
Fig.5. Mounting wall plate.

13
WIRING
All wiring must comply with local electrical codes and ordinances.
1. See Table 1 and Fig.6 for terminal designation descriptions. Insert wires in the
terminal block under the loosened screws. See Fig.7.
2. Securely tighten each screw.
3. Push excess wire back into the hole in the wall.
4. Plug the hole with nonflammable insulation to prevent drafts from affecting the
thermostat.

14
Table 1. Terminal Designation Descriptions.
Terminal Designation
Description
RC (see Note 1)
Power for cooling--connect to secondary side of cooling system 24v
transformer
R (see Note 1)
Power for heating--connect to secondary side of heating system 24v
transformer
C
Common wire from secondary side of 24V transformer
Y
Compressor contactor
G
Fan relay
Y2
Second stage cooling
O/B/W (see Note 2)
Changeover valve for heat pump systems or Heat relay
AUX/W2
Auxiliary heat relay for heat pump systems or Second stage heat relay
E
Emergency heat relay for heat pump systems
L (see note 3)
Equipment alarm monitor for heat pump systems

15
NOTES:
1. When used in a single-transformer system, leave the metal jumper wire in place
between RC and R. If used on a two-transformer system, remove the metal jumper
wire between RC and R.
2. If the thermostat is configured for a heat pump system, configure the changeover
valve for energized on cool or heat in the Installer setup.
3. The L terminal is an input for optional system alarm monitoring. If the terminal is
connected to 24V, ES (emergency signal) will appear on the screen, overriding the
room temperature display.
Fig.6.Terminal identifications.

16
Fig.7. Inserting wires in terminal block.
IMPORTANT: Use 18 gauge thermostat wire.
Table of contents
Other Vtronix Thermostat manuals
Popular Thermostat manuals by other brands

Beok Controls
Beok Controls TDR-83 user guide

Giacomini
Giacomini K492DY012 Instructions for use

Crestron
Crestron CHV-TSTAT-FCU-PIR-10-W-T quick start guide

Olimpia splendid
Olimpia splendid Bi2 B0659 Instructions for mounting and use

Aprilaire
Aprilaire S84N 1H1C owner's manual

AMX
AMX VST-TSTAT Dimensional drawing