VWR 531-1368 User manual

VWR®LCD Digital Rotary Evaporator
INSTRUCTION MANUAL
European Catalogue Number(s):
Main Unit
Heating Bath
Glassware
LCD Rotary Evaporator, set V17, bath
531-1368
531-1382
531-1375(Vertical, 1700cm²)
LCD Rotary Evaporator, set V17C, bath
531-1368
531-1382
531-1376(Vertical,1700cm²,Coated)
LCD Rotary Evaporator, set D17, bath
531-1368
531-1382
531-1378(Diagonal, 1700cm²)
LCD Rotary Evaporator, set V12, bath
531-1368
531-1382
531-1380(Vertical, 1200cm²)
Version: 1
Issued: 25, May, 2020

2/ 20
Legal Address of Manufacturer
Europe
VWR International bv
ResearchparkHaasrode 2020
Geldenaaksebaan 464
B-3001 Leuven
+ 32 16 385011
http://be.vwr.com
Country of origin
P. R. CHINA

3/ 20
Table of Contents
Warning....................................................................................................................................4
Safety Information .....................................................................................................................4
Package Contents.......................................................................................................................7
Unpacking.................................................................................................................................7
Installation................................................................................................................................8
Intended use............................................................................................................................11
Symbols and conventions..........................................................................................................11
Product Specifications ..............................................................................................................12
Overview................................................................................................................................13
Description of Buttons and Switches ..........................................................................................13
Operation................................................................................................................................15
Troubleshooting.......................................................................................................................15
Maintenance and Cleaning ........................................................................................................16
User replaceable accessories and spare parts................................................................................17
Technical service......................................................................................................................18
Warranty.................................................................................................................................18

4/ 20
Warning
Please carefully read the Instructions, and use the product safely under the direction of the
Instructions.
•
Our products are under the patent protection of the origin country and other countries and
regions (including obtained patents and patents being applied for).
•
We elaborately prepared the manual in the attitude of being responsible for the users. But we
can’t guarantee that the contents of the manual are fully correct. If any occasional or subsequent
loss is caused by the use of the Manual, the company will not be liable for this at all.
•
The manual is a pure technical document, free of any implication or oblique hint of any third
party. Moreover, we won’t be liable for any user’s misunderstanding upon the printer’s error(s).
•
The company and any of the company’s employees will not bear any liability for direct/indirect
loss of information or stop of business (if any) caused by the information of the manual or the
product it mentions.
•
The company reserves the right to change specification and price of the product.
•
If any information of the manual changes, we will not notify this otherwise.
•
The manual and any content of it must not be copied, abstracted or modified in any form
without the company’s written approval in advance.
Safety Information
•Read the operating instructions in full before starting up and follow the safety instructions.
•Keep the operating instructions in a place where they can be accessed by everyone.
•Ensure that only trained staff work with the appliance.
•Follow the safety instructions, guidelines, occupational health and safety and accident
prevention regulations. When working under a vacuum in particular!
•Wear your personal protective equipment in accordance with the hazard category of the
medium to be processed. Otherwise there is a risk of:
-splashing liquids,
-body parts, hair, clothing and jewelry getting caught,
-injury as a result of glass breakage.
•CAUTION! Inhalation of or contact with media such as poisonous liquids, gases, spray mist,
vapors, dusts or biological and microbiological materials can be hazardous to user.
•Set up the device in a spacious area on an even, stable, clean, non-slip, dry and fireproof

5/ 20
surface.
•Ensure that there is sufficient space above the device as the glass assembly may exceed the
height of the device.
•Prior to each use, always check the device, accessories and especially the glass parts for
damage. Do not use damaged components.
•Ensure that the glass assembly is tension-free! Danger of cracking as a result of:
-stress due to incorrect assembly,
-external mechanical hazards,
-local temperature peaks.
•Ensure that the stand does not start to move due to vibrations respectively unbalance.
•Beware of hazards due to:
-flammable materials,
-combustible media with a low boiling temperature,
-glass breakage.
•CAUTION! Only process and heat up media that has a flash point higher than the adjusted
safe temperature limit of the heating bath that has been set.
•The safe temperature limit of the heating bath must always be set to at least 25 °C lower than
the fire point of the media used.
•Do not operate the appliance in explosive atmospheres, with hazardous substances or under
water.
•Only process media that will not react dangerously to the extra energy produced through
processing. This also applies to any extra energy produced in other ways, e.g. through light
irradiation.
•Tasks with the device must only be performed when operation is monitored.
•Operation with excess pressure is not permitted (for cooling water pressure see "Technical
Data").
•Do not cover the ventilation slots of the device in order to ensure adequate cooling of the
drive.
•There may be electrostatic discharges between the medium and the drive which could pose a
direct danger.
•The appliance is not suitable for manual operation.
•Safe operation is only guaranteed with the accessories described in the ”Accessories”
chapter.
•Refer to the operating instructions for the accessories, e.g. vacuum pump.
•Only use the device under an all side-closed exhaust, or a comparable protective device.
•Adapt the quantity and the type of distill and to the size of the distillation equipment. The
cooler must work properly. Monitor the coolant flow rate at the cooler outlet.
•The glass equipment must always be ventilated when working under normal pressure (e.g.
open outlet at cooler) in order to prevent a pressure build-up.
•Please note that dangerous concentrations of gases, vapors or particulate matter can escape
through the outlet at the cooler. Take appropriate action to avoid this risk, for example,
downstream cold traps, gas wash bottles or an effective extraction system.
•Evacuated glass vessels must not be heated on one side; the evaporating flask must rotate

6/ 20
during the heating phase.
•The glassware is designed for operation under a vacuum of up to 10 mbar. The equipment
must be evacuated prior to heating (see chapter “Commissioning”). The equipment must only
be aired again after cooling. When carrying out vacuum distillation, uncondensed vapors
must be condensed out or safely dissipated. If there is a risk that the distillation residue could
disintegrate in the presence of oxygen, only inert gas must be admitted for stress relief.
•CAUTION! Avoid peroxide formation. Organic peroxides can accumulate in distillation and
exhaust residues and explode while decomposing!
•Keep liquids that tend to form organic peroxides away from light, in particular from UV rays
and check them prior to distillation and exhaust for the presence of peroxides. Any existing
peroxides must be eliminated. Many organic compounds are prone to the formation of
peroxides e.g. dekalin, diethyl ether, dioxane, tetrahydrofuran, as well as unsaturated
hydrocarbons, such as tetralin, diene, cumene and aldehydes, ketones and solutions of these
substances.
•DANGER OF BURNING! The heating bath, tempering medium, evaporator piston and glass
assembly can become hot during operation and remain so for a long time afterwards! Let the
components cool off before continuing work with the device.
•ATTENTION! Avoid delayed boiling! Never heat the evaporating flask in the heating bath
without switching on the rotary drive! Sudden foaming or exhaust gases indicate that flask
content is beginning to decompose. Switch off heating immediately. Use the lifting
mechanism to lift the evaporator piston out of the heating bath. Evacuate the danger zone
and warn those in the surrounding area!
•When the device is switched off or the power supply disconnected, the internal safety lift
removes the evaporator piston from the heating bath.
•CAUTION! Never operate the device when the evaporator piston is rotating and the lift is
raised. Always lower the evaporator piston into the heating bath first before starting the
rotation drive. Otherwise hot tempering medium may be sprayed out!
•Set the speed of the drive so no tempering medium is sprayed out as a result of the
evaporator piston rotating in the heating bath. If necessary, reduce the speed.
•Do not touch rotating parts during operation.
•Imbalance may result in uncontrolled resonance behavior of the device or assembly. Glass
apparatus may be damaged or destroyed. In the event of unbalance or unusual noises,
switch off the appliance immediately or reduce the speed.
•The appliance does not start up again automatically following a cut in the power supply.
•The device is only disconnected from the power
•supply network if the device power switch is off or the plug is pulled out.
•The socket for the mains cord must be easily accessible.
•The voltage stated on the type plate must correspond to the mains voltage.
•Socket must be earthed (protective ground contact).
•Removable parts must be refitted to the appliance to prevent the infiltration of foreign objects,
liquids etc.
•Protect the appliance and accessories from bumps and impacts.
•The appliance may only be opened by experts.

7/ 20
Package Contents
Product
No.
Description
Quantity
Main unit
1
Main unit
1
2
Instruction manual
1
3
Quick Guide
1
4
Wrench
1
5
Fuse6.3A
1
6
Fuse1A
1
7
Vapor Tube
1
8
Fastening Frame
1
9
Loop Fastener
1
10
Power Cable(Euro/UK/CH Plug)
3
Heating bath
1
Heating bath
1
Glassware set
(Condenser included is
depending of the set
configuration. For additional
condensers and glassware,
see page 17 for information).
1
531-1375(Vertical condenser, 1700cm²)
531-1376(Vertical condenser,1700cm²,Coated)
531-1378(Diagonal condenser, 1700cm²)
531-1380(Vertical condenser, 1200cm²)
1
2
Evaporating flask(1000ml)
1
3
Receiving flask(1000ml)
1
4
Pipe of PTFE
2
5
Screw cap
4
6
Hose Connection
3
7
Stopcock
1
8
Ball Joint Clamp
1
9
Plastic clip
1
Please refer to User replaceable accessories and spare parts (Page 17) for detail ordering
information including the glass assembly.
Unpacking
If you find any damage on the package, please specify the damage on the receipt. If you find any
internal damage after opening the package, please contact supplier or manufacturer.
Caution:
1. If you find any visible damage on the product, please don’t connect the product
to power supply.
2. Loosen transportation lock before Power ON.

8/ 20
Installation
•Adjustable base (Figure 1).
Figure 1
CAUTION! Loosen transportation lock Figure 2).
•Hold the lift with your hand on the height position and remove the thumb screw on the back of
the appliance (a).
•Once the transportation lock has been removed, the lift moves slowly to its upper end position.
The distance is 150mm.
•Connect the device to the power supply using power cable (b).
•Connect the heating bath to the device (c).
Figure 2
•Remove the clamping device for the angle setting of the rotation drive on the right side of the
lift by rotating the knurled screw (d) counterclockwise.
•Set the drive at an angle of approx.30°(Figure 3)
•Then secure the rotation drive from being accidentally turned by tightening the knurled screw
in a clockwise direction.

9/ 20
Figure 3
•Open the locking device on the drive head by turning it 60°counter clockwise (e), (Figure 4).
•Feed the steam pipe in until it stops.
•Then lock the locking device by turning it clockwise by 60°.
•The plastic screw nut (f) helps loosen evaporating flask(Figure 4)
-Hold the tight-fitting evaporator piston(e) and turn the plastic screw nut (f) until the evaporating
flask loosen.
Figure 4
Note: Prior to commissioning, hand-tighten the plastic screw nut (f) left-aligned.
•Installing condenser seal (Figure 5 and Figure 6).
Figure 5
Figure 6
•Installing condenser (g) (Figure 7 and Figure 8).
-Load the cap nut (h) and locking spring (i) to condenser in turn.
-Tighten the cap nut hand-screwed (h). Start the device at 200 rpm for 2 min. Then tighten

11 / 20
Intended use
This instrument is designed for such application environments as schools, labs and factories, in conjunction
with the optional accessories recommended by the manufacturer, which may be used for:
•Rapid softening of distilled liquid
•Distillation of solutions or suspensions
•Crystallization, synthesis or cleaning of chemicals
•Drying of powder or particulate substances
•Recovery of solvents
This instrument is intended for use in the following environment:
•Altitude: ≤2,000m ASL;
•Ambient temperature: 0-40°C;
•Voltage fluctuation: within the range of -10%~+10% of normal value (the product is designed for
indoor socket);
The product is unusable in residential area or under the restrictions specified inSafety Information.
Symbols and conventions
The following chart is an illustrated glossary of the symbols that are used in this manual.
[The following is an example only]
CAUTION This symbol indicates a potential risk and alerts you to proceed with caution
CAUTION This symbol indicates risks associated with hot surfaces

12 / 20
Product Specifications
Item
Specifications
Voltage [VAC]
100-240
Frequency [Hz]
50/60
Power [W]
1400
Motor
External rotor brushless motor
Speed Range [rpm]
20-280
Speed Display
LCD
Reversible Direction of Rotation
Yes
Temperature range [°C]
RT -180
Heat Control Accuracy[°C]
±1
Temperature Display
LCD
Heat Output[W]
1300
Lift
Motor
Stroke[mm]
150
Timer[mm]
1-999
Overall Dimensions [DⅹWⅹH, mm]
564ⅹ457ⅹ583
Weight [kg]
15
Permissible Ambient Temperature [°C]
5-40
Permissible Relative Humidity
80%
Protection class acc. to DIN 60529
IP20
USB
Yes

13 / 20
Overview
Welcome to choose our products. Users should read this Manual carefully, follow the instructions and
procedures, and be aware of all the cautions when using this instrument.
Fig. 1
Description of Buttons and Switches
Fig. 2
Fig. 3

14 / 20
Fig. 4
Name
Description
Speed key Speed
Push the key and then rotate control knob to set the rated speed in the range from 20
to 280.
Temperature key Temp
Push the key and then rotate control knob to set the rated temperature in the range
from room temperature to 180°C.
Timer key Timer
Push the key and then rotate control knob to set the rated time in the range from 1 to
999min.
Int key Int
Push the key and then rotate control knob to set the interval for right-left running in the
range from 1 to 999s.
Control knob
Clockwise rotate to increase program values. Rotate anti-clockwise to decrease
program values. Press the knob, switch ON/OFF the unit.
Lift-up key
Press the key, the lift goes up. Release the key the lift stops and remains in that
position.
Lift-down key
Press the key, the lift goes down. Release the key the lift stops and remains in that
position.
Fig. 5
Display
Description
Romote
Display in case of remote control.
Mot
Display when the rotating function is switched ON
Temp
Display when the heating function is switched ON.
Timer
Display when timer function is switched ON.
Int
Display when “Int” function is switched ON.
Speed display area
When setting speed, displaying the setting value and flashed. The setting value does not
flash until real speed reaches the set point.
Speed symbol
Display when the rotating function is switched ON.

15 / 20
Display
Description
Temperature display
area
When setting temperature, displaying the setting value. When the heating function is
switched ON, displaying the real value.
Temperature
Display when the heating function is switched ON.
Timer display area
When setting timer, displaying the rated time. When the timer function is switched ON,
displaying remaining time.
Interval display area
Displaying the “Int” target value.
Operation
•Make sure the required operating voltage and power supply voltage match.
•Ensure the socket must be properly grounded.
•Plug in the power cable,ensure the power is on and begin initializing.
•Press Lift-up/Lift-down key, the lift goes up/down. Release Lift-up/Lift-down key, the lift stops.
•Push the speed key and then rotate control knob to set the rated speed.
•Push the temperature key and then rotate control knob to set the rated temperature.
•Push the timer key and then rotate control knob to set the rated time.
•Deactivate the timer by setting the target value to “0”.
•Press the Int key and then rotate control knob to set the rated interval value.
•Deactivate the interval by setting the target value to “0”.
•Press the control knob, switch ON.
If these operations above are normal, the device is ready to operate. If not, the device may be
damaged during transportation and please contact manufacturer/supplier.
Note:
Please don’t remove the evaporating flask and receiving flask while the instrument
is in operation.
Troubleshooting
•Instruments can’t be power ON
-Check whether the power line is unplugged
-Check whether the fuse is broken or loose
•Fault in power on self-test
-Switch OFF the unit, then switch ON and reset the instruments to factory default setting.
•ERR 003, lift operation timeout
-Load overweight
•ERR 005, lift can’t work
-Check whether the transportation lock is loose
-Load overweight
If these faults are not resolved, please contact manufacturer/supplier

16 / 20
Maintenance and Cleaning
Operate and maintain the product properly, so that it is in a good working state, which can extend the
service life of the product. In routine service, keep the product dry and clean, remove the spilled liquid
quickly, clean the outer surface with a non-grinding cleaner, and do not connect the power supply until all
surfaces are dry. If liquid or moist solid enters the product, please disconnect the power supply quickly and
leave off, and contact the manufacturer / supplier for more advice.
•Keep the product clean, and the cleaning solution is not allowed to flow into the machine.
•Power must be disconnected before maintenance and cleaning, and please use our recommended
methods to clean the product. The method to clean:
Dye
Isopropanol
Building materials
Aqueous solution /isopropanol with active agent
Cosmetic
Aqueous solution /isopropanol with active agent
Food
Aqueous solution with active agent
Fuel oil
Aqueous solution with active agent
•You can consult the manufacturer about the materials that are not listed in the above table. Before
using other cleaning methods, the user must confirm with the manufacturer / supplier that the method
will not damage the instrument. When cleaning the product, please wear suitable protective gloves.

17 / 20
User replaceable accessories and spare parts
Description
Quantity
Cat. No.
Glassware set V17
1
531-1375
Glassware set V17C
1
531-1376
Glassware set D17
1
531-1378
Glassware set V12
1
531-1380
Evaporating flask 50ml
1
531-1384
Evaporating flask 100ml
1
531-1385
Evaporating flask 250ml
1
531-1386
Evaporating flask 500ml
1
531-1387
Evaporating flask 1000ml
1
531-1388
Evaporating flask 2000ml
1
531-1389
Coated evaporating flask 1000ml
1
531-1428
Receiving flask 100ml
1
531-1396
Receiving flask 250ml
1
531-1397
Receiving flask 500ml
1
531-1398
Receiving flask 1000ml
1
531-1399
Receiving flask 2000ml
1
531-1400
Coated receiving flask 1000ml
1
531-1429
Connector(NS 29/32, NS24/29)
1
531-1401
Connector(NS 29/32, NS19/26)
1
531-1402
Connector NS 29/32, NS14/23)
1
531-1403
Foam brake 250ml
1
531-1407
Vapor tube
1
531-1409
Distillation spider for simultaneous distillation
from 5 evaporating flasks(Without flasks) , 50ml
1
531-1411
Rubber ring with airtight lip-seal from a PTFE
compound with a built-in stainless steel spring
1
531-1413
Full fluorine ether rubber ring with airtight lip-seal
from a PTFE compound with a built-in stainless
steel spring
1
531-1414
Evaporation flask clip(red)
1
531-1415
Vacuum regulator /moisture trap (including the
vacuum meter and pressure regulating valve)
1
531-1417

18 / 20
Technical service
Web Resources
Visit the VWR website at vwr.com for:
• Complete technical service contact information
• Access to the VWR Online Catalogue, and information about accessories and related products
• Additional product information and special offers
Contact us For information or technical assistance contact your local VWR representative or visit vwr.com.
Warranty
VWR warrants that this product will be free from defects in material and workmanship for a period of two (2)
years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, replace, or refund
the purchase price of this product to the customer, provided it is returned during the warranty period. This
warranty does not apply if the product has been damaged by accident, abuse, misuse, or misapplication, or
from ordinary wear and tear. If the required maintenance and inspection services are not performed
according to the manuals and any local regulations, such warranty turns invalid, except to the extent, the
defect of the product is not due to such non-performance.
Items being returned must be insured by the customer against possible damage or loss. This warranty shall
be limited to the aforementioned remedies. IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE
IN LIEU OF ALL WARRANTIES OF FITNESS AND IN LIEU OF THE WARRANTY OF MERCHANTABILITY.
Compliance with local laws and regulations
The product structure conforms to the following safety standard:
EN 61010-1
EN 61010-2-10
The product structure conforms to the following EMC standard:
EN 61326-1
The product material conforms to the following ROHS standard:
Restriction of the Use of Certain HazardousSubstances in Electrical and Electronic Equipment, 2011/65/EU
The customer is responsible for applying for and obtaining the necessary regulatory approvals or other
authorisations necessary to run or use the Product in its local environment. VWR will not be held liable for any
related omission or for not obtaining the required approval or authorisation, unless any refusal is due to a
defect of the product.

19 / 20
Equipment disposal
This equipment is marked with the crossed out wheeled bin symbol to indicate that this equipment must not
be disposed of with unsorted waste.
Instead it's your responsibility to correctly dispose of your equipment at lifecycle -end by handling it over to an
authorized facility for separate collection and recycling. It's also your responsibility to decontaminate the
equipment in case of biological, chemical and/or radiological contamination, so as to protect from health
hazards the persons involved in the disposal and recycling of the equipment.
For more information about where you can drop off your waste of equipment, please contact your local dealer
from whom you originally purchased this equipment.
By doing so, you will help to conserve natural and environmental resources and you will ensure that your
equipment is recycled in a manner that protects human health.
Thank you

20 / 20
Local VWR offices in Europe and Asia Pacific
Austria
VWR International GmbH
Graumanngasse 7
1150 Vienna
Tel.: +43 1 97 002 0
Belgium
VWR International bv
Researchpark Haasrode 2020
Geldenaaksebaan 464
3001 Leuven
Tel.: +32 016 385 011
China
VWR International China Co., Ltd
Shanghai Branch
Room 256, No. 3058 Pusan Road
Pudong New District
Shanghai, 200123
Tel.: +86-21 589 868 88
Fax: +86-21 585 588 01
Czech Republic
VWR International s. r. o.
Veetee Business Park
Pražská 442
CZ - 281 67 StríbrnáSkalice
Tel.: +420 321 570 321
Denmark
VWR International A/S
Tobaksvejen 21
2860 Søborg
Tel.: +45 43 86 87 88
Finland
VWR International Oy
Valimotie 9
00380 Helsinki
Tel.: +358 9 80 45 51
France
VWR International S.A.S.
Le Périgares –Bâtiment B
201, rue Carnot
94126 Fontenay-sous-Bois cedex
Tel.: 0 825 02 30 30* (national)
Tel.: +33 (0) 1 45 14 85 00
(international)
* 0,18 € TTC/min
Germany
VWR International GmbH
Hilpertstrasse 20a
D - 64295 Darmstadt
Freecall: 0800 702 00 07
Tel.: +49 (0) 6151 3972 0
(international)
Hungary
VWR International Kft.
Simon Lászlóu. 4.
4034 Debrecen
Tel.: +36 (52) 521-130
India
VWR Lab Products Private Limited
No.139. BDA Industrial Suburb,
6th Main, Tumkur Road,
Peenya Post,
Bangalore, India –560058
Tel.: +91-80-28078400
Ireland / Northern Ireland
VWR International Ltd / VWR
International (Northern Ireland) Ltd
Orion Business Campus
Northwest Business Park
Ballycoolin
Dublin 15
Tel.: +353 01 88 22 222
Italy
VWR International S.r.l.
Via San Giusto 85
20153 Milano (MI)
Tel.: +39 02-3320311/02-487791
The Netherlands
VWR International B.V.
Postbus 8198
1005 AD Amsterdam
Tel.: +31 020 4808 400
Norway
VWR International AS
Brynsalleen 4
0667 OsloTel.: +47 22 90 00 00
Poland
VWR International Sp. z o.o.
Limbowa 5
80-175 Gdansk
Tel.: +48 058 32 38 210
Portugal
VWR International - Material de
Laboratório, Lda
Centro Empresarial de Alfragide
Rua da Indústria, nº6
2610-088 Amadora
Tel.: +351 21 3600 770
Singapore
VWR Singapore Pte Ltd
18 Gul Drive
Singapore 629468
Tel: +65 6505 0760
Spain
VWR International Eurolab S.L.
C/ Tecnología 5-17
A-7 Llinars Park
08450 - Llinars del Vallès
Barcelona
Tel.: +34 902 222 897
Sweden
VWR International AB
Fagerstagatan 18a
163 94 Stockholm
Tel.: +46 08 621 34 00
Switzerland
VWR International GmbH
Lerzenstrasse 16/18
8953 Dietikon
Tel.: +41 044 745 13 13
UK
VWR International Ltd
Customer Service Centre
Hunter Boulevard
Magna Park
Lutterworth
Leicestershire
LE17 4XN
Tel.: +44 (0) 800 22 33 44
This manual suits for next models
1
Table of contents
Popular Farm Equipment manuals by other brands

Titan Attachments
Titan Attachments GJDHD72RAKE Operator's manual

LEMKEN
LEMKEN Solitair DT/400 operating instructions

Ware Manufacturing
Ware Manufacturing 01465 Assembly instructions

J&M
J&M 1012 Operator's manual

BULK SEED SYSTEMS
BULK SEED SYSTEMS PRO-CHUTE 1 Setup

Landoll
Landoll VT Plus 7431 Operator's manual