W-Link D83 Series User manual

User Manual
---Apply to D83 Series NB/CAT-M1 IP Modem
V2.1
http://www.wlink-tech.com
Feb, 2019

D83 Modem User Manual
www.wlink-tech.com
1
Copyright © Shenzhen WLINK Technology Company Limited 2012 ~2019
Without our written approval, Anyone can’t extract, copy whole or part of content of this file and
can’t spread out in any format.
Caution
Due to product updates or functional upgrading, we may renew the content of this file, and this
file only for reference. All statement, information, suggestion.etc in this file do not compose any
form of guarantee and we WLINK reserves the right of final explanation.
Shenzhen WLINK Technology Company Limited
Add:
3F, Yiben Building, Chaguang Road, Xili, Nanshan District, China, 518054
Web:
http://www.wlink-tech.com
Service Email:
support@wlink-tech.com
Phone:
86-755-86089513
Fax:
86-755-26059261

D83 Modem User Manual
www.wlink-tech.com
2
Contents
1Product Introduction......................................................................................................................3
1.1 Product Overview............................................................................................................... 3
1.2 Typical Application Diagram............................................................................................. 3
1.3 Features............................................................................................................................... 4
2Hardware Installation....................................................................................................................5
2.1 LED Status...........................................................................................................................5
2.2 Dimension............................................................................................................................ 6
2.3 How to Install.......................................................................................................................6
3Configuration..................................................................................................................................8
3.1 Serial Port Settings.............................................................................................................8
3.2 D83 Serial to IP Modem Configuration......................................................................... 10
3.3 D83 Typical Application (point to point)........................................................................ 18

D83 Modem User Manual
www.wlink-tech.com
3
1Product Introduction
1.1 Product Overview
The rugged D83 serial to IP modem which is a cellular modem have been developed
especially for M2M/IoT application. It provides RS232/RS-485/TTL interface and equipped
with PPP, TCP/IP and DDP protocol, it could convert the user data into 4G, NB-IoT/CATM,
3G, EDGE or GPRS network and transmits the data to the customer’s data service center
through complete transparent data channel, allows a simple and rapid integration of
cellular network connectivity into M2M/IoT application.
With the robust, reliable, long life and compact metal case design, the D83 ideally adapts
to onboard standard, easy to deploy and maintenance, it has been widely applied in many
fields worldwide, such as power SCADA, oil field, coal mine, weather forecast,
environment protection, water conservancy, heating, natural gas, petroleum and so on.
1.2 Typical Application Diagram
Wlink 4G/NB/3G/2G modem widely used in AMR, Oil, transportation, power grid, mining and
other industries fields.

D83 Modem User Manual
www.wlink-tech.com
4
Figure 1-1 Network Topology
1.3 Features
Various cellular module optional, 4G/NB/3G/2G optional
Optimized EMC design
Standard PPP, Coap/TCP/IP and UDP/IP protocol
Industrial pluggable terminal block
Industrial 4G/NB/3G/EDGE/GPRS wireless module
Support APN and VPDN wireless private network
Support short message service (SMS)
Support transparent data transmission
Support data service center with dynamic IP address
Support LED status indication
Wide range voltage input
Smart power management
External power on/off control
Reliable, flexible and easy to deploy

D83 Modem User Manual
www.wlink-tech.com
5
2Hardware Installation
This chapter is mainly for installation introduction, there would be some difference
between the scheme and real object. But the difference doesn’t have any influence to
products performance.
2.1 LED Status
LED indicator Status
silk-screen
color
status
Indication
NET
Red
Weak Signal
CSQ<20
Green
Good Signal
CSQ>21
Fast Blinking
Self-checking
Light on
2s,Light off 1s
Standby
Light on 1s,
Light off 2s
Online
PWR
Green
Light on
D83 system runs

D83 Modem User Manual
www.wlink-tech.com
6
2.2 Dimension
2.3 How to Install
2.3.1 SIM/UIM card installation
Open SIM shelter by screw-driver, then insert SIM/UIM card.
Before connecting, please disconnect any power resource of D83.
SIM/UIM Card

D83 Modem User Manual
www.wlink-tech.com
7
2.3.2 Serial port
PIN
1
2
3
4
5
6
7
8
9
RS232
Tx
Rx
GND
RS485
B
A
TTL
Tx
Rx
GND
2.3.4 Power Supply
In order to get high reliability, adapt wide voltage input: +5V~+36VDC, support hot plug
and complex application environment.
2.3.5 Review
After insert the SIM/UIM card, connect serial cable, necessary antenna, then connect
power cable.
Please connect the antenna before connect the power cable, otherwise because of
impedance mismatching, the signal maybe poor.
Notice:
Step 1 Check antenna connection.
Step 2 Check SIM/UIM card, configure SIM/UIM card is available.
Step 3 Power on D83

D83 Modem User Manual
www.wlink-tech.com
8
3Configuration
3.1 Serial Port Settings
Run D83 Config Tool and select serial port, then setup serial port parameters in the
bottom of D83 Config Tool as below.
Run Config Tool, click Config button to setup serial port parameters as below.
Baud Rate: 57600bps

D83 Modem User Manual
www.wlink-tech.com
9
Data Bit: 8bit
Parity: None
Stop Bit: 1bit
Click Connect button, modem will be connected to the tool and enter configuration mode.
If the connection is successful, it will display Connected dialog box as below.
【Config】Tool Serial port configuration.
【Connect】Connect D83.
【Disconnect】Close serial port to leave configuration mode.
【Import】Import configuration file into Config tool.
【Export】Export current settings to file. It’s convenient for butch setup.
【Default】Setup D83 to default settings.
【Read】Inquiry current D83 setting.
【Save】Save settings to D83.

D83 Modem User Manual
www.wlink-tech.com
10
3.2 D83 Serial to IP Modem Configuration
3.2.1 COM Settings
COM settings instruction.
Parameters
Description
Instruction
Default
Baud rate
Serial port properties
300/600/1200/2400/4800/9600/19200/384
00/57600/115200 optional.
RS232 Port for 115200bps as default.
RS485 Port for 115200bps as default.
Data bits
8
8
Stop bits
1/2
1
Parity
NULL/ODD/EVEN
NULL
Trans Proto
Transmission protocol between D83
and device. Under command mode,
terminal might setup D83
configuration.
Transparent and Command are optional.
The default is for transparent protocol.
Transparent
Max Package
Length
The max transmission unit. Once data
package length exceeds to MTU, D83
will split data package as MTU.
1~1024bytes
1024bytes
Min Internal
The Min Interval is the waiting time
interval for transmitting the data
package that is less the MTU. If the
last package equals to the MTU, D83
will transmit it immediately.
100~1000ms
300ms

D83 Modem User Manual
www.wlink-tech.com
11
Parameters
Description
Instruction
Default
Data center 1 IP
Data server center IP address(static
IP address)
D83 will transmit COM1 data to Data
center 1
0.0.0.0
Port
Data server center port
0~65535
40001
Protocol
UDP/TCP
UDP
Domain name
No static IP for server
It’s just available when center IP is
configured as 0.0.0.0,
NULL
3.2.2 Cellular Settings
Cellular settings instruction
Parameters
Description
Instruction
Default
APN
SIM information for dial up
1~63bytes
cmnet
User name
0~63bytes
NULL
Password
0~63bytes
NULL
Ping IP
address
Check destination IP address
0.0.0.0
Domain Name
Check destination domain name. If
IP 0.0.0.0 and domain name is null,
Ping is disable.
0~63byts
NULL
Interval
PING check interval when idle.
0~255mins
0 indicates PING is disable status.
0
Primary DNS
Defined Primary DDNS server IP
address
If configured 0.0.0.0, D83 will use
default DNS IP address as domain name
resolution server.
0.0.0.0

D83 Modem User Manual
www.wlink-tech.com
12
Parameters
Description
Instruction
Default
Secondary
DNS
Defined secondary DDNS server IP
address
If main DNS for 0.0.0.0, the secondary
DNS will be invalid.
0.0.0.0
PIN
SIM card PIN code
If SIM card is defined PIN code. It need
to be configured the correct PIN code in
D83. Otherwise, D83 won’t identify SIM.
If configured an error PIN code in D83,
SIM card will be damage.
We suggest not pre-configure PIN code
in SIM card.
NULL
3.2.3 Data Center settings
Data Center settings instruction
Parameters
Description
Instruction
Default
First center IP
First Data server center IP
address(static IP address)
0.0.0.0
Port
0~65535
40001
Connect type
UDP/TCP
UDP
Domain name
No static IP for server
Only when setup center IP as 0.0.0.0, it’s
just available.
N/A
Second center IP
Second Data server center IP
address(static IP address)
0.0.0.0
Port
0~65535
40002

D83 Modem User Manual
www.wlink-tech.com
13
Parameters
Description
Instruction
Default
Connect Type
UDP/TCP
UDP
Second Domain
Name
No static IP for server
Only when setup center IP as 0.0.0.0, it’s
just available.
N/A
Third center IP
Third Data server center IP
address(static IP address)
0.0.0.0
Port
0~65535
40003
Connect Type
UDP/TCP
UDP
Third Domain
Name
No static IP for server
Only when setup center IP as 0.0.0.0, it’s
just available.
N/A
1. D83 will synchronously connect to 3 data center when configured 3 center IP inside of
tool.
2. D83 will retry connect other centers as long as it has connected one center.
3. D83 will redial up if it’s failed to connect all of 3 centers more than 9times in
succession.
3.2.4 Protocol settings
Communication Protocol settings instruction

D83 Modem User Manual
www.wlink-tech.com
14
Parameters
Description
Instruction
Default
Custom ID
Identify D83 in data server center
4byte length
NULL
Protocol Options
Transparent/WLINK/DDP
[Transparent]Transparent transmission.
[DRMP]WLINK transmission protocol.
[HD-DDP]unavailable
Transparent
ID Position
ID insert data package in order to
identify which D83 sent data.
0~24bytes
1
Heartbeat
Interval
0~65535s
D83 will automatically send heartbeat to
data server as defined setting. It will keep
the connection between D83 and data
center.
0 means no heartbeat
0
ID Position
ID insert data package in order to
identify which D83 sent data.
0~24bytes
0
Custom
Heartbeat
Package
D83 log in data center server and
keep connection.
0~24bytes
NULL
Custom ACK
Package
D83 receive ACK after sent heartbeat.
If no ACK 3times in succession, D83
will reconnect to data center server.
0~24bytes
NULL
3.2.5 Work Mode Setting

D83 Modem User Manual
www.wlink-tech.com
15
Parameters
Description
Instruction
Default
Mode Select
ONLINE/WAKEUP
[ONLINE] After powered on, D83
automatically connect and reconnect to
data center server to keep online always.
[WAKEUP] After Powered on, D83 will
work on standby mode. Once D83
received wake up short message from
defined phone number, or received the
triggering data from terminal, D83 will dial
up and connect to data center server. After
idle time, D83 will re-enter wake up mode.
[SMS] D83 works short message mode.
NULL
Reconnect
Interval
D83 reconnect to data center server
after interval time when connection is
failed.
5~65535s
300s
Idle Interval
5~65535s
300s
Discard
WAKEUP DATA
SMS Number
Short message and call wake up and
short message configuration from the
specified number.
0~31bytes
NULL
Allow to Transfer
SMS
D83 will transmit any short message
to terminal
Enable/Disable
Disable
Transfer SMS
Transfer SMS to COM1/COM2
COM1/COM2 Options
COM1
Debug
Control serial port debug information
NONE/DEBUG/STATUS/AT. Configure AT
level during testing with PC. Configure
NULL, then connect D83 to device.
[NONE] D83 won’t send any information to
serial port.
[DEBUG]D83 sends simple information to
serial port. It’s convenient to test D83.
[Status]D83 sends operation status,
signal strength to serial.
[AT] D83 sends all debug information to
serial port. It’s convenient to test D83
Switch CMD
D83 will be switched to configuration
mode from transmission mode. After
switched to configuration mode, The
D83 will enter command mode to
communicate with terminal.
6 visible characters
++++++

D83 Modem User Manual
www.wlink-tech.com
16
3.2.6 Manage settings
Remote management settings instruction
Parameters
Description
Instruction
Default
Run Mode
Online/Timing mode options
Online
Start Interval
D83 will connect to remote
management software as this start
interval time.
0 means this function is invalid.
Reconnection
D83 will reconnect to remote
management software as this interval
time when the connection is down.
0~65535s
1440s
Remote IP
WLINK remote management platform
IP address in HQ
D83 will automatically login WLINK
management platform so that customers
might manage and monitor D83 in platform
0.0.0.0
Port
0~65535
51010
Domain Name
No static IP in HQ
Domain name is available when the IP
address is setup 0.0.0.0
NULL

D83 Modem User Manual
www.wlink-tech.com
17
3.2.7 Upgrade settings
Upgrade settings instruction
Parameters
Description
Instruction
Default
Firmware
Select firmware
The firmware is Bin file
FW Name
Firmware name
FW Version
Firmware version
Firmware Size
Firmware size
Checksum
Firmware Verification
Start
Upgrade firmware
Click Start button to upgrade firmware.
Restart D83 modem after upgrade is
completed.

D83 Modem User Manual
www.wlink-tech.com
18
3.2.8 Production Info
Information instruction
Parameters
Description
Instruction
Default
Product Name
Product Model
Serial Port Type
Version
SN
---End
3.3 D83 Typical Application (point to point)
D83 establishes a TCP connection to data server center. D83 transmits serial port data to
data server center by TCP protocol. D83 acts as TCP client as below settings. The serial
port tool SSCOM32 simulates serial port device. TCP/IP net Assistant tool simulates data
server center.

D83 Modem User Manual
www.wlink-tech.com
19
D83 Settings List
Parameters Menu
Settings
Note
Serial
Serial
Configure baud rate, data bit, stop bit and parity to match
with terminal.
Debug
If test D83 with PC’s serial tool, better select STATUS
which is easy to check D83 status.
If tested D83 with device, better select NONE.
Network
APN
Uninet
User name
NULL
Password
NULL
PING
221.118.79.21
Connection
First Center IP
221.118.79.21
Port
50081
Heartbeat Interval
120
Protocol
Custom ID
13900000001
Protocol Select
NONE
ID position
0
Custom Heartbeat Package
hello
Custom ACK Package
yes
Work Mode
Mode Select
ONLINE
Reconnect Interval
300
Remote
Start Interval
0
Table of contents