WAC Lighting 9075-TRN-SS User manual

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAY 31, 2016 10:13 AM
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
1
IMPORTANT:
Read all instructions before installing.
• Read all instructions before proceeding with the
installation.
• This power supply complies with the
requirements of UL1838. This power supply
should be installed in compliance with the
National Electrical Code and local electrical
codes. This unit is for use with landscape lighting
systems only.
• WARNING –Risk of Electric Shock. Install power
unit 5 feet (1.5 m) or more from a pool or spa and
10 feet (3.05 m) or more from a fountain. Where
the power unit is installed within 10 feet
(3.05 m) of a pool or spa connect power unit
to a GFCI protected branch circuit.
• Do not modify or change the product in any
way. This product is to be installed by a qualied
electrician only. Failure to do so will void the
warranty and may result in serious injury and/or
damage to the transformer.
• Connect directly to an outlet; do not use an
extension cord with this product. For 120 Volt AC
operation only. Be sure that the supply circuit is
energized. If this occurs, the circuit breaker can
be replaced with a breaker rated for high in-rush
currents and should only be done by a qualied
electrician.
• To avoid risk of re do not use a xture or a
combinations of xtures where the total watts
exceed the rating of the power supply.
IMPORTANTE:
Lea todas las instrucciones antes de instalar.
• No conecte este temporizador en un cable
de extensión u otro adaptador de corriente.
Conecte directamente a una toma eléctrica.
• No conecte el contador a los aparatos que
contienen
• elementos de calefacción (de aparatos de
cocina, calentadores, planchas, etc.)
• El fallo del temporizador para apagar dicho
dispositivo puede provocar un
sobrecalentamiento y un posible incendio.
• No conecte este temporizador si está húmedo.
• No limpie este temporizador cuando está
enchufado int.
• No exceder los valores máximos del
temporizador.
• Posible riesgo de descarga:
Mantener fuera del alcance de los niños.
IMPORTANT:
Lisez toutes les instructions avant de l’installer.
• Ne branchez pas ce temporisateur dans une
rallonge ou un autre adaptateur électrique.
Brancher directement dans une prise électrique.
• Ne pas relier cette minuterie pour les appareils
qui contiennent
• éléments de chauage (appareils de cuisson,
chaue, un fer à repasser, etc.)
• L’échec de l’horloge pour éteindre tel dispositif
peut entraîner une surchaue et un incendie.
• Ne branchez pas cette minuterie si elle est
mouillée.
• Ne nettoyez pas ce temporisateur quand il
est branché int.
• Ne pas dépasser les évaluations maximales
de la minuterie.
• Risque d’électrocution:
Conserver hors de la portée des enfants.
INSTALLATION GUIDELINES
• One or more circuit breakers are included with each transformer. To reset, turn breaker to on position. If circuit breakers trip repeatedly,
have the system inspected by a qualied electrician.
• The transformer includes an internal thermal protector and will run the transformer o if the unit over-heats. The thermal protector will
also automatically reset.
• Where possible, it is best to install the transformer in the center of the lighting installation to minimize long runs reducing voltage drop.
THIS INSTRUCTIONS APPLY TO THE MODEL BELOW:
9075-TRN-SS 9150-TRN-SS 9300-TRN-SS
INSTALLATION INSTRUCTION
Magnetic Transformer
9075-TRN-SS / 9150-TRN-SS / 9300-TRN-SS

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAY 31, 2016 10:13 AM
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
2
FEATURES AND CONTROLS:
1. Take-apart stainless cover
The cover can be removed for greater access to wiring compartment during installation.
To remove, open the cover by unscrewing the four screws from the sides.
2. Operating instructions on the cover
Refer to these instructions for additional information on specications of the product
3. Overload circuit breakers
For reliable automatic secondary circuit protection. Circuit breakers may also be used as on/o rocker switches.
4. 1/2” – 3/4” Knockouts
For conduit and accessory mounting
5. 1/2” – 3/4” Knockouts
For conduit and accessory mounting
6. Terminal strip
For multiple low voltage cable connections
7. Power cord
Heavy-gauge, grounded, water-resistant power cord with integrally molded plug.
8. 120-volt timer module receptacle
For use with optional, removable multi-setting mechanical 24-hour timer or electronic/digital 7-day timer.
9. Photocell plug
For use with photocell, remove jumper and plug photocell here.
10. Locking Hole (for model 9150-TRN-SS and 9300-TRN-SS)
Can be secured to prevent tampering
11. Conduit cover (for model 9150-TRN-SS and 9300-TRN-SS)
Remove the conduit cover and use Trade Size 1-1/4 inch conduit
INSTALLATION INSTRUCTION
Magnetic Transformer
9075-TRN-SS / 9150-TRN-SS / 9300-TRN-SS
10
11
=
use looped wire to test
primary amps under full load
NRsNQs
NPs
NOs
` lj
SUITABLE FOR WET LOCATION
LOW VOLTAGE LANDSCAPE POWER SUPPLY
MADE IN CHINA
DC-2015-11-06
MODEL:JCOBS12D75B1-1-PI
INPUT:120V 60HZ 0.625A
OUTPUT:12V-13V-14V-15V
MAX.RATING:75W 6.25A
` l sb o==j r pq==_b==f kp q^i i ba
j l r kq=qe fp =rk fq =kl =i bpp =qe^k =N=cl l q=
^_l s b=do l rk a=i bs bi =t f qe=^ oolt p
mlf kqb a=r m
ISOLATED WINDING TYPE TRANSFORMER
CIRCUIT INTERRUPTER OUTLET LOCATED AT LEAST 10FT
THIS UNIT IS EQUIPPED WITH A THERMAL PROTECTOR
BREAKER TRIPS CHECK TOTAL WATTAGE OF LAMPS OR FOR A SHORT
IN THE CIRCUIT
PLUG PHOTOCELL
HERE
(CREMOVE JUMPER)
PHOTOCELL PLUG
TIMER MODULE
RECEPTACLE
l cc
l k
1
2
3
4
5
6
7
8

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAY 31, 2016 10:13 AM
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
3
INSTALLATION INSTRUCTION
Magnetic Transformer
9075-TRN-SS / 9150-TRN-SS / 9300-TRN-SS
MOUNTING INSTRUCTIONS:
1. Carefully locate and install the power supply so that it is not
in contact with insulation or combustible materials. Provide
minimum of 12 inches of airspace around the power supply.
Transformer must also be mounted a minimum of 12 inches above
grade. (Fig. 1)
2. Securely mount the power supply using the mounting brackets on
the power supply enclosure. Drill screw holes at the right locations
(see dimensions in Fig. 1) and make sure use appropriate screws
for the selected mounting surface.
3. Hang transformer case securely over the screws.
4. Plug in the power cord to a GFCI protected outlet with a cover that
complies with the National Electrical Code for the location.
5. Use appropriate and approved wiring methods to connect the
power supply and the lighting xtures.
6. When using this power supply, the voltage will be reduced and the
current will be signicantly increased.
7. When complete, use the loop on the photocell terminal to
verify that the input current does not exceed the rating of the
transformer.
TRANSFORMER SIZING VA VALUE
Low voltage lighting systems require the use of a transformer to reduce the standard 120 volt power from ordinary household electricity to
the 12 volt needed to power low voltage lamps. Transformers vary in size of capacity. The total lamp VA (load) of all xtures connected to one
transformer must not exceed the VA capacity of the transformer. Therefore, to determine the transformer size needed, simply add up the VA
of all lamps you plan to use.
TRANSFORMER SIZE > TOTAL FIXTURE VA
Select a transformer that matches as closely as possible to your total lamp VA. If you total VA is too great, either divide the total load between
two transformers or use a more powerful model. Selecting a transformer with about 20% higher capacity than you total lamp VA will allow for
adding a xture or two later.
13 7/16”
18 5/16”
GFCI Outlet
Fig. 1
2”
12” Min

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAY 31, 2016 10:13 AM
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
4
LOW VOLTAGE CABLE LENGTH
In planning a low voltage system, it is necessary to consider the impact of voltage drop. Because of cable’s inherent resistance, voltage drops
along its length: the end-of-run lamps will be dimmer than those at the beginning. Since voltage drop is a function of cable length and cable
size and total xture wattage, voltage drop can be minimized in several dierent ways:
• Use multiple cable runs
• Use heavier gauge cable(8 or 10 gauge)
• Shorten cable lengths or runs
• Reduce VA of individual xtures
• Reduce the total number of xtures on a run
• Use multiple transformers in dierent locations
Cable is measured by gauge. The lower the number, the thicker the cable and the more current it carries. Common cable size for low voltage
lighting is available in three gauges: #12-2, #10-2, and #8-2. To calculate maximum cable length, use the formula below:
Vd=
Vd= Voltage drop in the section of cable, in volts
L = Length of the section of the cable (one way distance), in feet
VA = Total VA values carried by the section of cable for the xtures it supplies
Kc= Cable Constant as follow:
Please refer to WAC Lighting website for voltage drop calculator.
CABLE CONNECTION DETAIL
1. Open the cover of the transformer and remove the Knockouts at
the bottom of the transformer as necessary.
2. Run lighting cables through Knockouts from the bottom of the
transformer.
3. Connect the low voltage cables to the COMs and low voltage
taps labeled on the Terminal Blocks. Make sure that all Cable
Connecting Screws are secure and tight.
L×VA×2
Kc
Cable Size Kc
12
10
8
7500
11920
18960
Do Not Exceed 0.625 Amps on primary
use looped wire to test
primary amps under full load
15V14V
13V
12V
COM
PLUG PHOTOCELL
HERE
(CREMOVE JUMPER)
PHOTOCELL PLUG
TIMER MODULE
RECEPTACLE
OFF
ON
Terminal Blocks
Cable Connecting Screw
Knockouts
INSTALLATION INSTRUCTION
Magnetic Transformer
9075-TRN-SS / 9150-TRN-SS / 9300-TRN-SS

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAY 31, 2016 10:13 AM
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
5
INSTALLATION INSTRUCTION
Magnetic Transformer
9075-TRN-SS / 9150-TRN-SS / 9300-TRN-SS
INSTALLING A PHOTOCELL
1. Unplug the transformer from the outlet, open the enclosure
2. Remove a knockout from the side of the enclosure, and install the
photocell
3. Remove the jumper, plug the photocell into the socket
4. Position the photocell so that the operation is not aected by any
light xture.
5. Note: For remote installation, the L-Bracket can be used to mount
the photocell in desired position.
l k
l cc
TIMER MODULE
RECEPTACLE
PHOTOCELL PLUG
PLUG PHOTOCELL
HERE
(CREMOVE JUMPER)
` l j
NOs
NPs
NQsNRs
=
Do Not Exceed 0.625 Amps on primary
Photocell Jumper
Photocell
Quick Connector
Photocell
Knockout
On - Board Installation
9000-PCH-GY
Photocell
Knockout
Mounting Nut
`
Photocell
Mounting Nut 1
Mounting Nut 2
L-Bracket
Waterproof Plug
Remote Installation
9000-PCR-GY

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MAY 31, 2016 10:13 AM
waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
6
INSTALLING A TIMER
1. Unplug the transformer from the outlet, open the enclosure
2. Unplug the short timer cord inside the enclosure
3. Plug in the timer, plug the short timer cord into the timer
4. Set the timer according to the instructions provided with the time
l k
l cc
TIMER MODULE
RECEPTACLE
PHOTOCELL PLUG
PLUG PHOTOCELL
HERE
(CREMOVE JUMPER)
` l j
NOs
NPs
NQsNRs
=
Do Not Exceed 0.625 Amps on primary
Short Timer Cord
Timer Plug
Timer
INSTALLATION INSTRUCTION
Magnetic Transformer
9075-TRN-SS / 9150-TRN-SS / 9300-TRN-SS
CHECK THE SYSTEM
After installing the entire low voltage system, operate the system for ve minutes. On the low voltage side, all electrical connection spots
should be cool to touch. If a connection is hot to the touch, retighten the connection and check to ensure that the temperature decreases.
Place the transformer cover back and tighten all four provided screws on both sides.
If there’s any irregularities, email or call WAC Lighting “Technical Support” at Sales@waclighting.com, (800)526.2588.
This manual suits for next models
2
Table of contents
Other WAC Lighting Transformer manuals
Popular Transformer manuals by other brands

Titanium
Titanium TT-DR-CV-080 quick start guide

Sea gull lighting
Sea gull lighting AMBIANCE HC-342 Installation and safety instructions

Heidemann
Heidemann 70044 Installation guidelines

France
France P8G-2B installation guide

STERNO HOME
STERNO HOME GL33050 instructions

weschler instruments
weschler instruments Transformer Advantage CT owner's manual