EC Declaration of Conformity
Manufacturer:
Walrus Pump Co., Ltd.
Address:
No. 83 -14, Dapiantou, Sanjhih Township, Taipei County 252, Taiwan
Declare that the machinery described:
Name : Water Pump
Model : TPRK Series
Conform to the following directive:
98/37/EC-----Machinery directive
2006/95/EC—Low voltage directive
2004/108/EC----EMC (Electromagnetic compatibility) directive
Refer to the following standards:
EN ISO 12100-1:2003 EN ISO 12100-2:2003
EN1050:1996
EN60335-1:2001 EN 809:1998
EN60335-2-41:2001
EN61000-6-2 EN61000-6-3
R&D department manager: Kao Tien-chuan
Manager:
~ 2 ~
Please read this instruction manual
carefully before installing your new
system as failures caused by
incorrect installation and operation
are not cover by the warranty.
1. Application
1.1. The TPRK series is multi-stage centrifugal
pump designed for industrial use,
especially for machine tools.
1.2 The pump can not be used to transfer
explosive liquids; such as gasoline, diesel
oil or similar liquids. It is suitable to carry
liquids such as water, coolant, low viscosity
or other non-corrosive liquids.
2. Product Code Designation
The standard range of pumps includes
complete impeller in chamber combinations.
Upon request, a special length can be supplied
by fitting empty intermediate chambers instead
of standard chambers with impellers. The pump
nameplate indicates the number of chambers
and impellers fitted to the pump.
3. Operating Limits
1. Ambient temperature :Max. 50oC(122oF)
2. Liquid temperature range : 0oC(32oF) to
90oC(194oF)
3. Operating pressure :Max. 25 kg/cm²
4. Submerged depth :Min. 65mm
4. Installation
The pump has hot surface on the
motor. It must be installed so that
persons cannot accidentally come
into contact the hot surface.
4.1. Submerged Depth
To avoid dry running and damage the pump
during operation, the minimum pump
submerged depth is 65mm (2½”) as shown in
Fig 1. In addition, the bottom of the pump
suction inlet must be at least 25 mm (1”) above
the bottom of the tank.
5. Electrical Connection
5.1 The electrical connection should
be carried out in accordance
with local regulations. Never
make any connections unless
the electricity supply has been
switched off.
5.2. The electrical hazard warning
mark is placed outside the
connection box. Be careful.
5.3. Electrical data (voltage and frequency) are
shown on the pump nameplate. Verify if
these data match your electricity supply. A
circuit breaker should be installed and the
grounding be properly connected for your
safety.
5.4. Make electrical connection in accordance
with connecting diagram located inside the
Min. 65 mm (2½”)
25 mm (1”)
Fig.1
TPRK 2T 13 - 12 S
Stainless steel series
Number of Impellers
Number of stages
Standard capacity m3/h
Model code