~ 3 ~
This mark located outside the
connection box is a warning for
an electrical hazard.
Before operation, please check if the
voltage is correct and be sure if the circuit
breaker and grounding connectors are all
connected in accordance with local
regulations.
Single-phase power supply
3. Wiring diagram
WARNING:
Risk of Electric Shock - This pump is
supplied with a grounding conductor and
grounding-type attachment plug. To reduce
the risk of electric shock, be certain that it
is connected only to a properly grounded,
grounding-type receptacle".
L2
Input power Grounding
L1
4. Operation
Never run pump when no water is available.
When you have successfully installed the
pump and fill the chamber with water,
please follow the instructions on Fig. 2 to
start up the operation.
4.1.1. Remove the filling plug and fill the
chamber with water and then replace the
plug.
a. Remove the filling plug
b. Fill water in chamber
Water
c. Replace the filling plug
Fig. 2
4.1.2. When the pump inlet is lower than the
water supply level, please remove the
filling plug to let water back flow to the
chamber. It can be repeated as many
times as necessary till the air is
completely released from system. Then,
replace your filling plug.
4.1.3. For start up of the first operation or
after long time inactivity, please place a
screwdriver against the shaft at motor
end and turn clockwise to see if rotor
spins freely. (Fig. 3). If it is, you are free
to run the pump.
4.1.4. When the pump is running normally,
please measure the running current with
a wattmeter. If it exceeds the rated value
on nameplate, please check if your power
supply voltage is within ±10%. Please
contact your pump supplier if you are not
sure how to correct it.
2.1.11. For your safety, please hook up a
circuit breaker and connect grounding
connections to the pump in accordance
with local regulations.
~ 4 ~
5.2 Pump doesn't start:
a). Not enough water supply, the security
system has been activated and the LED
(FAILURE) is on --- check the water
supply and restart the pump through
the reset switch(RESET).
b). Pump is blocked: LED (FAILURE) is on
and the security system is activated.
When we act on the manual start switch
(RESET) the LED (ON) is activated but
the pump doesn't work --- consult your
dealer.
c). Failure in the electronic circuit --- switch
off power supply, wait a few seconds
and turn it on again. If the pump doesn't
start immediately then replace the
circuit.
d). No electrical supply --- check the proper
electric feeding. The tension LED
(POWER) should be on.
e). Not enough pump pressure --- the
security system has been activated and
the corresponding LED (FAILURE) is
on. Check that the pump pressure is
0.8kg/cm² higher than the starting
pressure of the controller.
f). Air in the pump aspiration --- the
pressure gauge will indicate a pressure
lower than the nominal or constant
oscillations.The security system will act
by stopping the pump and the LED
(FAILURE) will be on. Check the sealing
of the connections and O-ring of the
aspiration conduct.
5.3 The pump starts and stops repeatedly:
a). Small leakage in some point of the
installation --- verify possible tap of
tank leakages and repair them.
5.POSSIBLE PROBLEMS
5.1 Pump doesn't stop:
a). Water leakage higher than 1.2 l/min at
some point --- check the system,the
tap,etc.
b). Manual start switch (RESET) is blocked
--- press it for several times. Consult
your dealer if the problem persists.
c). Breakdown on the electronic board ---
proceed to its substitution
Fig. 3
4.2.1. Be sure that the pump is correctly
primed, and then gently open the tap.
4.2.2. Connect the controller to the electric
supply. The tension LED will light
(POWER)
4.2.3. The pump starts working automatically
and within a period of 20-25 seconds the
pressure gauge will reach approximately
the maximum pressure provided by the
pump.
During its working the corresponding LED
(ON) will be on.
4.2.4. If there is no discharge flow after a few
minutes, please turn off the pump and
repeat the Process of 4.2.1. Turn the
pump on and off several times until it is
working normally.
4.2.5. Close the tap indicated on point 1 After
7-9 seconds the pump will stop. The
tension LED (POWER) will be the only
one to remain on. Any problem after this
procedure will be due to defective pump
priming.