WatchNet WAB P FCKS User manual

Page 1of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
WatchNET Access Integrated Security Management Software
WAB P FCKS User Manual

Page 2of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
User Manual
WAB P FCKS
Biometric Standalone Controller

Page 3of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Index
................................................................................................................................................................................
Revision History ....................................................................................................................................................4
Chapter 1 Introduction..........................................................................................................................................4
1.1 Summary.................................................................................................................................................4
1.2 Features..................................................................................................................................................5
1.3 Application Mode ...................................................................................................................................6
Chapter2 Wiring Diagram .....................................................................................................................................6
2.1 WAB BEM FCK-S Appearance..................................................................................................................6
2.2 Wiring Diagram.......................................................................................................................................7
2.3 Lock Wiring Diagram...............................................................................................................................8
Chapter3 Instructions .........................................................................................................................................10
3.1 Personnel Management .......................................................................................................................11
3.1.1 Add Personnel ...........................................................................................................................11
3.1. 2 Delete Personnel ......................................................................................................................16
3.1.3 Modify .......................................................................................................................................17
3.1.4 Add Admin.................................................................................................................................17
3.1.5 Delete All...................................................................................................................................18
3.2 Network Configuration .........................................................................................................................19
3.2. 1 Terminal ID ...............................................................................................................................19
3.2.2 Net Configure ............................................................................................................................20
3.2.3 IP Address..................................................................................................................................20
3.2.4 Subnet Mask..............................................................................................................................21
3.2.5 Gateway.....................................................................................................................................22
3.2.6 Host IP .......................................................................................................................................23
3.2.7 Host Port....................................................................................................................................24
3.3 Option...................................................................................................................................................25
3.3.1 Language ...................................................................................................................................25
3.3.2 Clock Setting..............................................................................................................................25
3.3.3 Screensaver ...............................................................................................................................26
3.3.4 Door Relay .................................................................................................................................27
3.3.5 Multi FP Verify...........................................................................................................................27
3.3.6 Tamper Alarm............................................................................................................................28
3.4 Device ...................................................................................................................................................28
3.4.1 FP-Module.................................................................................................................................28
3.4.2 WG Setting ................................................................................................................................30
3.4.3 Card Number Mode...................................................................................................................30
3.4.4 Display Mode.............................................................................................................................31
3.4.5 Terminal Initialize ......................................................................................................................32
3.4 Terminal Info.........................................................................................................................................32
3.5 Door Open Mode..................................................................................................................................33
Chapter 4 Installation..........................................................................................................................................34
4.1 In the Wall.............................................................................................................................................34
4.2 Without Installation Box.......................................................................................................................35
Chapter 5 FAQ .....................................................................................................................................................36

Page 4of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Revision History
Revision
Date
Author
Description of Changes
1.0
03/28/2014
Pradeep Kumaran
Manual Created.
Chapter 1 Introduction
1.1 Summary
WAB BEM FCK-S is a new outstanding biometric standalone controller with TFT color display
developed by WATCHNET. When WAB BEM FCK-S is used as a T&A controller the employees
need to press their finger on the reader sensor to complete attendance. The TFT screen will
display time and staff ID information. This system greatly improves the T&A simplicity and
offer’s a cost saving on traditional tags. When the WAB BEM FCK-S is used as an access
controller the traditional key is no longer needed. The employees can enter their special area
by flashing authorized cards. The WAB BEM FCK-S can by itself control both in and out doors
and at least one reader is needed for one side. The other side can be controlled either by a
reader or a Rex Button. The WAB BEM FCK-S provides a more convenient and secured access
environment and it also makes it possible for managers to verify the time and attendance. The
WAB BEM FCK-S is compatible with a large range of applications including, building
management, enterprise management, government, military and prison.
WAB BEM FCK-S
WAB BEM FCK-S for Standalone

Page 5of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Model Definition:
WAB BEM FCK-S/E------ Built in EM Card Reader
WAB BEM FCK-S/H----- Built in HID Card Reader
WAB BEM FCK-S/U------ Built in Mifare\CPU Card Reader
Supported Card Type:
E:EM Card;Exp EM4100,TK4100 Series.
H:HID Card;Exp: 1326、1386 Series.
U:FM1208 CPU Card,Philips S50,Mifare-1 Compatible
1.2 Features
TFT color display with elegant appearance.
Standard Wiegand 26/34 output and compatibility with Wiegand format access controller.
Dust and water resistant and suitable for a wide range of installations.
Quick responding and anti-interference, low power consumption and stable.
WDT circuit, self-checking function.
High speed fingerprint matching, 3000 fingerprints within 1 second.
Multithreaded code that takes full advantage of multi-core CPU.
500dpi optical biometric sensor, scratch resistant.
World leading fingerprint algorithm, resistant fake fingerprint.
Support Chinese/English interface.
Background picture and company name can be changed base on customer’s requirement.
Display card number, user name, employee ID and etc.
Specifications
CPU:400MHz DSP
Memory:4MB Flash memory+8MB RAM
Fingerprint storage:3000 pcs(expandable to 8000 pcs)
Supported card:
E:Proximity EM4100 series
M:S50 compatible Mifare card or other compatible cards
Biometric sensor:500 dpi optical biometric sensor
Verify mode:FP, Card, Card + FP, ID+FP
Communication interfaces:Wiegand output, TCP/IP communicate
Working voltage:12VDC
Working current ≤200mA
Standby current≤150mA
Temperature:-20°C to 65°C
Humidity:0--95%
Dimension:197mm L x88mm W x 35mm
Weight:490 g

Page 6of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
1.3 Application Mode
3 Application Modes:
Standalone
Outdoor external reader, indoor WAB BEM FCK-S
Indoor external reader, outdoor WAB BEM FCK-S
Chapter2 Wiring Diagram
2.1 WAB BEM FCK-S Appearance
LED:
Blue LED:Power indicator
Green LED:Sensor indicator(Relay on indicator)
Keypad:
NO.
Key
Description
NO.
Key
Description
1
1
Numeral 1
9
9
Numeral 9
2
2
Numeral 2
10
0
Numeral 0
3
3
Numeral 3
11
Esc
Exit
4
4
Numeral 4
12
Door bell
5
5
Numeral 5
13
Delete
6
6
Numeral 6
14
Next/.symbol
7
7
Numeral 7
15
Menu
Menu
8
8
Numeral 8
16
Enter
Enter/Confirm
室内接
读卡器

Page 7of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
2.2 Wiring Diagram
Figure 2-2 Wiring Sketch
Icon
NO
Connect
ion
Definition
Icon
NO
Connecti
on
Definition
J1
1
GND
Power supply
Door contact,
Rex Button,
Auxiliary
output
J3
13
D1_Out
Reader signal
input/output
2
+12V
14
D0_ Out
3
SEN
15
+12V
4
BUT
16
GND
5
GND
17
D1_In
6
IN1
18
D0_In
J2
7
NO1
Relay output
J4
19
RJ45
TCP/IP interface
8
COM1
9
NC1
10
NO2
11
COM2
12
NC2
Figure 2-1
J2:Relay Output
J4:TCP/IP Interface
J3:Reader signal output/input
J1:Power、Door
contact、Switch
inputs

Page 8of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Wiring Description:
J1: Power supply, Magnetic door contact, Rex Button, Auxiliary input
12V:DC 12V Positive
GND:Ground
SEN:Door contact
BUT:Rex Button,
GND:Ground
IN1:Auxiliary input
J2: Relay output
Based on customized lock model and power requirement.
J3 Reader signal input/output
D1_Out :Wiegand signal output
D0_ Out:Wiegand signal output
+12V:DC 12V Positive
GND:Ground
D1_In: Wiegand signal input
D0_In:Wiegand signal input
J4: TCP/IP interface
Customer can set all configurations when it’s connected to host PC. Moreover user
authorization and exporting card events can also be done via manage software.
To use a switch or directly connect to host PC via Ethernet port.
2.3 Lock Wiring Diagram
J4: Relay Output Lock Control
As shown below.
Figure 2-5 Lock Fail safe

Page 9of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Figure 2-6 lock Fail secure

Page 10 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
Chapter3 Instructions
User Management、PIN management、Work mode and Time set are configured in the manage menu.
Menu structure is shown below.

Page 11 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
3.1 Personnel Management
3.1.1 Add Personnel
1.Press the Menu button to enter manage menu when WAB BEM FCK-S is idle. In the
following steps the Esc works as cancel while Enter works as confirm.
2.Press 1 to enter User interface. (As shown below)
3.Press 1 again to enter Add interface (As shown below)
4.Input the new ID and press enter for the next interface. (As shown below)
WatchNET
1. User
2. Network
3. Option
4. Device
5. Terminal Info
6.
7.
WatchNET
1.Add
2.Delete
3.Modify
4.Add Admin
5.Delete All
WatchNET
New ID
--------------
WatchNET
1.FP
2.FP/Card
3.FP+CARD
4.User ID+FP
5.User ID + Card

Page 12 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
3.1.1.1 FP
1. Press 1 to enter Add FP interface. (As shown below)
2. Select a level according to customer’s requirement (High level for high matching accuracy, but
will slow down responding time), press Enter to enter the next interface.
3. Press 0 to confirm that the FP is attached to the User ID, or press 1 for searching FP in
the database. Press Enter to enter the next interface.
4. Place and remove your finger twice to finish registering. The screen will display “Add FP
OK” and then go back to the main menu.
3.1.1.2 FP/Card
To enter the following interfaces refer to section 3.1.1.
1. Press 2 to enter add FP/Card interface. (As shown below)
WatchNET
Level 1:1
(0~9):0
WatchNET
Enable 1:N
:
(N=0/Y=1):
WatchNET
〈Add FP〉
Put Your FP
WatchNET
1.FP
2.FP/Card
3.FP+CARD
4.User ID + FP
5.User ID + Card

Page 13 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
2.Place the card in the sensor area and the system will enter the next interface after a
beeping sound.
3. Select a level according to customer’s requirement (High level for high matching
accuracy, but will slow down responding time), press Enter to enter the next
interface.
4. Press 0 to confirm that the FP is attached to the User ID, or press 1 for searching FP in
the database. Press Enter to enter the next interface.
5. Place and remove your finger twice to finish registering. The screen will display “Add
FP OK” and then go back to the main menu.
3.1.1.3 FP + Card
To enter the following interfaces refer to section 3.1.1.
WatchNET
Add card
Place your card
WatchNET
Level 1:1
(0~9):0
WatchNET
Enable 1:N
:
(N=0/Y=1):
WatchNET
〈Add FP〉
Put your FP

Page 14 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
1. Press 3 to enter add FP + Card interface. (As shown below)
2. Place the card in the sensor area. The system will enter the next interface after a
beeping sound.
3. Select a level according to customer’s requirement (High level for high matching
accuracy, but will slow down responding time), press Enter to enter the next
interface.
4. Place and remove your finger twice to finish registering. The screen will display “Add
FP OK” and then go back to the main menu.
3.1.1.4 User ID + FP
To enter the following interfaces refer to section 3.1.1.
WatchNET
1.FP
2.FP/Card
3.FP+CARD
4.User ID+FP
5.User ID+ card
WatchNET
Add Card
Place your card
WatchNET
Level 1:1
(0~9):0
WatchNET
〈Add FP〉
Put your FP

Page 15 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
1. Press 4 to enter add User ID + FP interface. (As shown below)
2. Select a level according to customer’s requirement (High level for high matching
accuracy, but will slow down responding time), press Enter to enter the next
interface.
3. Place and remove your finger twice to finish registering. The screen will display “Add
FP OK” and then go back to the main menu.
3.1.1.5 User ID + Card
To enter the following interfaces refer to section 3.1.1.
1. Press 5 to enter add User ID + Card interface. (As shown below)
WatchNET
1.FP
2.FP/Card
3.FP+CARD
4.User ID+FP
5.User ID + card
WatchNET
Level 1:1
(0~9):0
WatchNET
〈Add FP〉
Put your FP
WatchNET
1.FP
2.FP/Card
3.FP+CARD
4.User ID + FP
5.User ID + Card

Page 16 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
2. Place the card in the sensor area. The system will enter the next interface after a
beeping sound.
3.1. 2 Delete Personnel
1. Press the Menu button to enter the manage menu when WAB BEM FCK-S is idle. In
the following steps, Esc works as cancel while Enter works as confirm.
2. Press 1 to enter User interface. (As shown below)
3Press 2 to enter the Delete interface.
4Input the User ID which is to be deleted, then press Enter to confirm.
WatchNET
Add Card
Place your card
WatchNET
1. User
2. Network
3. Option
4. Device
5. Terminal Info
WatchNET
1.Add
2.Delete
3.Modify
4.Add Admin
5.Delete All
WatchNET
User ID [DEL]
--------------

Page 17 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
3.1.3 Modify
1. Press the Menu button to enter manage menu when WAB BEM FCK-S is idle. In the
following steps, Esc works as cancel while Enter works as confirm.
2. Press 1 to enter the User interface. (As shown below)
3. Press 3 to enter the Modify interface.
4. Input the User ID which is to be modified the customer can change configuration like
level 1:1 or replace FP or card.
3.1.4 Add Admin
1. Press the Menu button to enter the manage menu when WAB BEM FCK-S is idle. In the
following steps, Esc works as cancel while Enter works as confirm.
2. Press 1 to enter User interface. (As shown below)
WatchNET
1. User
2. Network
3. Option
4. Device
5. Terminal Info
2.
3.
WatchNET
1.Add
2.Delete
3.Modify
4.Add Admin
5.Delete All
WatchNET
Input User ID [MOD]
--------------
WatchNET
1. User
2. Network
3. Option
4. Device
5. Terminal Info
2.
3.

Page 18 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
3. Press 4 to enter Add Admin interface.
4. Input new Admin ID and press Enter for the next interface. Refer to section 3.1.1.
3.1.5 Delete All
1. Press the Menu button to enter manage menu when WAB BEM FCK-S is idle. In the
following steps, Esc works as cancel while Enter works as confirm.
2. Press 1 to enter User interface. (As shown below)
3. Press 5 to enter the Delete All interface.
WatchNET
1.Add
2.Delete
3.Modify
4.Add Admin
5.Delete All
WatchNET
Admin ID (NEW)
--------------
WatchNET
1. User
2. Network
3. Option
4. Device
5. Terminal Info
2.
3.
WatchNET
1.Add
2.Delete
3.Modify
4.Add Admin
5.Delete All

Page 19 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
4. Press the corresponding number to select Yes or No and press Enter to confirm deletion.
3.2 Network Configuration
3.2. 1 Terminal ID
1. Press the Menu button to enter the manage menu WAB BEM FCK-S is idle. In the
following steps, Esc works as cancel while Enter works as confirm.
2. Press 2 to enter the Network interface. (As shown below)
3. Press 1 to enter Terminal ID interface. ( stands for delete button,
stands for symbolic button)
WatchNET
Delete all?
[Y=1/N=2]:
WatchNET
1. User
2. Network
3. Option
4. Device
5. Terminal Info
2.
3.
WatchNET
1.Terminal ID
2.Net Configure
3.IP Address
4.Subnet Mask
5.Gateway
6. Host IP
7. Host Port
WatchNET
〈Terminal ID〉
0001

Page 20 of 36 351 Ferrier Street • Markham, ON • L3R 5Z2
PHONE: 416-410-6865 TOLL FREE: 1-866-331-3341 • FAX: 905-752-0186
4. Input the Terminal ID by using the keypad and press Enter to confirm.
3.2.2 Net Configure
1. Press Menu button to enter the manage menu WAB BEM FCK-S is idle. In the
following steps, Esc works as cancel while Enter works as confirm.
2. Press 2 to enter the Network interface. (As shown below)
3. Press 2 to enter the Net Configuration interface. ( stands for the delete
button, stands for the symbolic button)
4. Select a configuration and input the corresponding number then press Enter to
confirm.
3.2.3 IP Address
1.Press the Menu button to enter the manage menu WAB BEM FCK-S is idle. In the
following steps, Esc works as cancel while Enter works as confirm.
WatchNET
1. User
2. Network
3. Option
4. Device
5. Terminal Info
2.
3.
4.
WatchNET
1.Terminal ID
2.Net Configure
3.IP Address
4.Subnet Mask
5.Gateway
6. Host IP
7. Host Port
WatchNET
Net Configure:0
0=Writable
1=Protected
2=Forced IP
Table of contents
Other WatchNet Controllers manuals
Popular Controllers manuals by other brands

function Innovation & Technology AS
function Innovation & Technology AS KNX MultiLight user manual

Siemens
Siemens MO310 operating instructions

Diagraph
Diagraph 4000-HMI Operation manual

Festo
Festo DFPD-HD-Series operating instructions

iSMA
iSMA MVE2 Series manual

RenewAire
RenewAire DN-Series quick start guide