Water Care TC1-TW User manual

For Models:
• TC1-TW
• TC2-TW
• CSE-TW
• CSP-TW
• CSERC-TW
• CSPRC-TW
TotalCare®
, CareSoft Elite®and
CareSoft Pro®Series
Twin Water Softeners and Conditioners

TABLE OF CONTENTS
Preinstallation Instructions for Dealers 3
Bypass Valve 4
Installation 5-6
Programming Procedures 7-8
Operating Displays and Instructions 9-10
Start-up Instructions 11
Troubleshooting Guide 12-15
Service Instructions for Transfer Assemblies 16-17
Replacement Parts 18-30
Specifications 31-32
Warranty 33
Quick Reference Guide 34-35
Your WaterCare twin water softeners and conditioners are precision built, high quality products These units
will deliver conditioned water for many years to come, when installed and operated properly Please study
this manual carefully and understand the cautions and notes before installing This manual should be kept for
future reference If you have any questions regarding your water conditioner, contact your local dealer or the
manufacturer at the following:
1900 Prospect Court • Appleton, WI 54914
Phone: 920-739-9401 • Fax: 920-739-9406
YOUR WATER TEST
Hardness _____________________ gpg
Iron __________________________ ppm
pH ___________________________ number
*Nitrates ______________________ ppm
Manganese ___________________ ppm
Sulphur _______________________ yes/no
Total Dissolved Solids ___________
*Over 10 ppm may be harmful for human consumption
Water conditioners do not remove nitrates or coliform bacteria,
this requires specialized equipment

PREINSTALLATION INSTRUCTIONS FOR DEALERS:
3
The manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and
salt dose refill time
The dealer should read this page and guide the installer regarding hardness, day override, time of regeneration,
service alarm and buzzer alarm settings before installation.
For the installer, the following must be used:
• Program Installer Settings: Time of Day and Hardness (manufacturer has set system to Immediate Regeneration;
see Operating Displays and Instructions for more details), Service Alarms (preset to “OFF”) and Buzzer Alarm
(preset to start at 6 am and end at 10 pm)
• Read Normal Operating Displays
• Set Time of Day
• Read Power Loss & Error Display
• Be sure system and installation are in compliance with all state and local laws and regulations
For the homeowner, please read Programming Procedures and Operating Displays and Instructions
During operation, the normal user display is time of day and gallons per minute
Flow Rate, Vacation Mode, Capacity Remaining and Days to a Regeneration are optional displays but are not normally
used (Vacation Mode is used only when there will be no water usage for an extended period of time Once 50 gallons
of water is used, the unit will automatically regenerate that night and resume normal operation) Each of these can be
viewed by pressing next to scroll through them When stepping through any programming, if no buttons are pressed
within 5 minutes, the display returns to a normal user display Any changes made prior to the 5 minute time out are
incorporated To quickly exit any Programming, Installer Settings, etc, press set clock Any changes made prior to the
exit are incorporated

The bypass valve is typically used to isolate the control valve from the plumbing system’s water pressure in order to perform control
valve repairs or maintenance The 1” full flow bypass valve incorporates four positions, including a diagnostic position that allows
a service technician to have pressure to test a system while providing untreated bypass water to the building Be sure to install
bypass valve onto main control valve, before beginning plumbing Or, make provisions in the plumbing system for a bypass The
bypass body and rotors are glass-filled Noryl® and the nuts and caps are glass-filled polypropylene All seals are self-lubricating
EPDM to help prevent valve seizing after long periods of non-use Internal “O” Rings can easily be replaced if service is required
The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The
handles identify the direction of flow The plug valves enable the bypass valve to operate in four positions
1 NORMAL OPERATION POSITION: The inlet and outlet handles point in the direction of flow indicated by the engraved
arrows on the control valve Water flows through the control valve for normal operation of a water softener During
the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the
distribution system (Fig. 1)
2 BYPASS POSITION: The inlet and outlet handles point to the center of the bypass The system is isolated from the water
pressure in the plumbing system Untreated water is supplied to the building (Fig. 2)
3 DIAGNOSTIC POSITION: The inlet handle points toward the control valve and the outlet handle points to the center of
bypass valve Untreated supply water is allowed to flow to the system and to the building, while not allowing water to exit
from the system to the building (Fig. 3) This allows the service technician to draw brine and perform other tests without the
test water going to the building
NOTE: The system must be rinsed before returning the bypass valve to the normal position
4 SHUT OFF POSITION: The inlet handle points to the center of the bypass valve and the outlet handle points away from
the control valve The water is shut off to the building The water treatment system will depressurize upon opening a tap in
the building A negative pressure in the building combined with the softener being in regeneration could cause a siphoning
of brine into the building If water is available on the outlet side of the softener, it is an indication of water bypassing the
system (Fig. 4) (ie a plumbing cross-connection somewhere in the building)
NORMAL
OPERATION
POSITION BYPASS POSITION DIAGNOSTIC
POSITION SHUT OFF
POSITION
FIGURE 1 FIGURE 3FIGURE 2 FIGURE 4
BYPASS VALVE:
4

GENERAL INSTALLATION & SERVICE WARNINGS
The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments There is a small
amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing
Do not use Vaseline, oils, other hydrocarbon lubricants or spray silicone anywhere A silicone lubricant may be used on black
“O” Rings, but is not necessary Avoid any type of lubricants, including silicone, on red or clear lip seals.
Do not use pipe dope or other sealants on threads. Teflon® tape must be used on the threads of the 1” NPT inlet and outlet, the
brine line connection at the control valve, and on the threads for the drain line connection Teflon® tape is not used on the nut
connections or caps because “O” Ring seals are used The nuts and caps are designed to be unscrewed or tightened by hand
or with the special plastic Service Wrench, #CV3193-02 If necessary pliers can be used to unscrew the nut or cap Do not
use a pipe wrench to tighten nuts or caps Do not place screwdriver in slots on caps and/or tap with a hammer.
SITE REQUIREMENTS
• water pressure – 25-100 psi • current draw is 05 amperes
• water temperature – 33-100°F (05-377°C) • the plug-in transformer is for dry locations only
• electrical – 115/120V, 60Hz uninterrupted outlet
• the tank should be on a firm level surface
1 The distance between the drain and the water conditioner should be as short as possible
2 Since salt must be periodically added to the brine tank, it should be located where it is easily accessible
3 Do not install any water conditioner with less than 10 feet of piping between its outlet and the inlet of a water heater
4 Do not locate unit where it or its connections (including the drain and overflow lines) will ever be subjected to room
temperatures under 33°F
5 Do not subject the tank to any vacuum, as this may cause an “implosion” and could result in leaking If there is a possibility
a vacuum could occur, please make provision for a vacuum breaker in the installation
6 INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control
valve before beginning plumbing (See installation picture to right.
Be sure bypass is connected to treated water inlet
and outlet.) Make provisions to bypass outside hydrant and
cold hard water lines at this time Install an inlet shutoff valve
and plumb to the unit’s bypass valve inlet located at the right
rear as you face the unit There are a variety of installation
fittings available They are listed under Installation Fitting
Assemblies, page 28-30 When assembling the installation
fitting package (inlet and outlet), connect the fitting to the
WELL WATER INSTALLATION MUNICIPAL INSTALLATION
INSTALLATION:
5

6
plumbing system first and then attach the nut, split ring and “O” Ring Heat from soldering or solvent cements may
damage the nut, split ring or “O” Ring Solder joints should be cool and solvent cements should be set before installing
the nut, split ring and “O” Ring Avoid getting solder flux, primer, and solvent cement on any part of the “O” Rings,
split rings, bypass valve or control valve If the building’s electrical system is grounded to the plumbing, install a copper
grounding strap from the inlet to the outlet pipe Plumbing must be done in accordance with all applicable local codes
7 INSTALLING GROUND: To maintain an electrical ground in metal
plumbing of a home’s cold water piping (such as a copper plumbing
system), install a ground clamp or jumper wiring
NOTE: If replacing an existing softener, also replace the ground clamps/
wire If removing a softener, replace the piping with the same type of piping
as the original to assure plumbing integrity and grounding
8 DRAIN LINE: First, be sure that the drain can handle the backwash rate of the system Solder joints near the drain must
be done prior to connecting the drain line flow control fitting Leave at least 6” between the drain line flow control fitting
and solder joints Failure to do this could cause interior damage to the flow control Install a 1/2” ID flexible plastic tube
to the Drain Line Assembly or discard the tubing nut and use the 3/4” NPT fitting for rigid pipe (recommended)
If the backwash rate is greater than 7 gpm, use a 3/4” rigid drain line. Where the drain line is elevated
but empties into a drain below the level of the control valve, form a 7” loop at the discharge end of the line so that the
bottom of the loop is level with the drain connection on the control valve This will provide an adequate anti-siphon trap
Piping the drain line overhead <10 ft is normally not a problem Be sure adequate pressure is available (40-60 psi is
recommended) Where the drain empties into an overhead sewer line, a sink-type trap must be used Run drain tube to its
discharge point in accordance with plumbing codes Pay special attention to codes for air gaps and anti-siphon devices
NOTE: Drain line nut will not be supplied for units having a backwash rate greater than 7 gpm
9 BRINE TANK CONNECTION: Install the 3/8” OD polyethylene tube from the Refill Elbow to the Brine Valve in the
brine tank
10 OVERFLOW LINE CONNECTION: An overflow drain line is recommended where a brine overflow could damage
furnishings or the building structure. Your softener is equipped with a brine tank safety float which greatly reduces
the chance of an accidental brine overflow In the event of a malfunction, however, an overflow line connection will
direct the “overflow” to the drain instead of spilling on the floor where it could cause considerable damage This
fitting is an elbow on the side of the brine tank Attach a length of 1/2” ID tubing to fitting and run to drain Do
not elevate overflow line higher than 3” below bottom of overflow fitting Do not “tie” this tube into the drain line of
the control valve Overflow line must be a direct, separate line from overflow fitting to drain, sewer, or tub Allow an
air gap as per the drain line instructions
CAUTION: Never insert a drain line into a drain, sewer line, or trap. Always allow
an air gap between the drain line and the wastewater to prevent the
possibility of sewage being back-siphoned into the conditioner.
bottom drain line
TYPICAL DRAIN LINE INSTALLATIONS

7
1. Set time of day:
PROGRAMMING PROCEDURES:
NOTE: The manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated
after the hardness is entered
STEP 1 – Press next and + simultaneously for 3 seconds
STEP 2 – HARDNESS:Set the amount of hardness in grains per gallon (default 20)
using the + or — buttons The allowable range is from 1 to 150 in 1 grain
increments
NOTE: If a resin media is used in the softener, increase the grains per
gallon if soluble iron is present (1 ppm = 4 gpg) This display will show
“–nA– (not available)” if “FILTER” is selected or if “AUTO” is not factory set
Press next to go to step 3
Press regen if you want to exit
STEP 3 – DAYS BETWEEN REGENERATION (DAY OVERRIDE): The manufacturer
has factory set OFF as the default When set to “OFF”, regeneration initiation
is based solely on gallons used If any number is set (allowable range from
1 to 28), a regeneration initiation will be called for on that day even if a
sufficient number of gallons were not used to call for a regeneration
Set Day Override using + or — buttons (6 is recommended):
• set number of days between regeneration (1 to 28); or
• set to “OFF”
Press next to go to step 4 Press regen to return to the previous step
2. Programming:
Time of day should only need to be set after extended power outages or when daylight saving time begins or ends If an
extended power outage occurs, the time of day will flash on and off indicating that the time should be reset
STEP 1 – Press set clock
STEP 2 – CURRENT TIME (HOUR): Set the hour of the day using + or — buttons AM/PM toggles after 12
Press next to go to step 3
STEP 3 – CURRENT TIME (MINUTES): Set the minutes using + or — buttons If it is desired to back up to the
previous step press regen button once Press next to go to step 4
STEP 4 – CURRENT DAY: Set the day of the week using + or — buttons Pressing next will exit set clock and
return to the general operating display (page 9)
TIME HOUR
SET
2:00
AM
2
TIME MINUTES
SET
2:10
AM
3CURRENT DAY
SET
MON
4
1
1
WATER HARDNESS
SET
20
GR
2
DAYS BETWEEN REGEN
SET
OFF
3

8
STEP 4 – IMMEDIATE REGENERATION: The manufacturer has set the regeneration to
occur when zero gallons remain When this occurs, the standby tank will switch
into service and provide treated water while the tank requiring regeneration will
start this process
Press next to go to step 5 Press regen to return to the previous step
STEP 5 – SERVICE ALARM GALLONS: The manufacturer has factory set “OFF”
as the default This feature is used to signal service into the future This is
typically set by the installing dealer to warn homeowner that service is
required after a preset number of gallons have been consumed If the
feature is active, a specific gallon amount will appear
Press next three times to advance past this screen
STEP 6 – SERVICE ALARM TIME: The manufacturer has factory set “OFF” as the
default This feature is used to signal service into the future This is typically
set by the installing dealer to warn homeowner that service is required after a
period of time has passed If the feature is active, a specific number of days
will appear
Press next three times to advance past this screen
STEP 7 – ALARM BUZZER: The manufacturer has factory set “ON” as the default An
alarm will sound (at the indicated time) after a regeneration, if there is no salt
or if another error has occurred Turn the alarm “OFF” or “ON” using the + or
— buttons Press next
NOTE: This feature allows you to program the time in which the alarm
buzzer will sound, permitting the installer to pick a time when the owner will
be home or awake to hear it
Setting Alarm Buzzer Start Time: Press + or — button to select the correct
hour the buzzer is to start sounding Be sure to also set AM or PM as necessary
(Default is set to 6:00 am) Press next
Setting Alarm Buzzer End Time: Press + or — button to select the
correct hour the buzzer is to stop sounding in the day Be sure to also set
AM or PM as necessary (Default is set to 10:00 pm) Press next
STEP 8 – DISPLAY BACKLIGHT: The manufacturer has factory set “ON” as the
default Turn the light “OFF” or “ON” using the + or — buttons “OFF”
will turn display backlight off after five minutes of keypad inactivity
Press next to exit installer programming
REGEN IMMEDIATE
ON ZERO
GAL
4
5
SERVICE ALARM GAL
SET
100
GAL
SERVICE ALARM
SET
OFF
GAL
ALARM BUZZER START
SET
ALARM BUZZER END
SET
6:00
AM
10:00
PM
ALARM BUZZER
SET
ON
7
LIGHT NORMALLY
SET
ON
8
6
SERVICE ALARM TIME
SET
1.25
YR
SERVICE ALARM
SET
OFF
YR

9
OPERATING DISPLAYS AND INSTRUCTIONS:
1 GENERAL OPERATION: When the system is operating, one of five displays may be shown and will alternate with the
installing dealer’s name and phone number (if set) for future service Pressing next will alternate between the displays
1 CURRENT TIME OF DAY and GPM. Letter indicates which tank is in service GPM alternates with current flow rate
2 FLOW RATE which is the current treated water flow rate through either tank A or B in Gallons Per Minute
3 VACATION MODE allows the system to be “shut down” when there will be no water usage for an extended
period of time
4. CAPACITY REMAINING for the tank in service (A or B) and the gallons that will be treated before the system
signals a regeneration cycle and switches to the other tank GPM alternates with current flow rate
5 DAYS TO A REGEN is the number of days left before the system goes through a regeneration cycle, based on the
days override value Letter indicates which tank is in service GPM alternates with current flow rate
6 DEALER NAME AND PHONE NUMBER is the dealer information to call when service is needed (this screen will
only appear if set by dealer)
The user can scroll between the displays as desired
2 VACATION MODE: This feature may be used to “shut down” the system while on vacation The manufacturer has
factory set “OFF” as the default Turn feature “OFF” or “ON” using the + or — buttons When turned “ON”, the
unit will not regenerate while there is no water usage Once water usage is observed (minimum of 50 gallons), the
unit will automatically regenerate that night and resume normal operation
CAUTION: Depending on the severity of water conditions and the length of no water
usage, it may not be recommended to use this feature. Please contact
dealer or manufacturer for more information.
3 MANUAL REGENERATION:Sometimes there is a need to regenerate before the control valve calls for it This
may be needed if the system has been operated without salt for an extended period of time To initiate a manual
regeneration immediately, press and hold the regen button for three seconds The system will begin to regenerate
immediately This command cannot be cancelled.
Once a manual regeneration is initiated, the unit will transfer to the second tank in order to supply conditioned
water Upon transfer, the depleted tank will begin its regeneration
4 REGENERATION MODE:Typically a twin system regenerates when the capacity
of the tank providing treated water reaches zero remaining gallons At this time, the
online tank will transfer and put the standby tank online so there is no disruption
of treated water Once this transfer is complete, the depleted tank will regenerate
and return to standby mode ready to enter service upon depletion of capacity of
other tank This two tank configuration provides for a continuous, uninterrupted
supply of conditioned water at all times When the system begins to regenerate, the display will change to include
information about the step of the regeneration process and the time remaining for that step to be completed
The system will run through all remaining steps automatically and will reset to provide treated water when the
regeneration process has been completed
BACKWASH
8:22
REGENERATION MODE
1TIME OF DAY MON
GPM
2:40A
PM
2FLOW RATE
GPM
8.0
A
5
ON VACATION
NO
6PHONE NUMBER
DEALER NA
3
4DAYS TO A REGEN
GPM
3
A
CAPACITY REMAINING
GPM GAL
1600
A

5 POWER LOSS AND BATTERY REPLACEMENT: The transformer comes with a
15 foot power cord and is designed for use with the control valve; the transformer
should only be used in a dry location
In the event of a power outage, the control valve will remember all settings and
time of day If an extended power outage occurs, the control valve will keep time
of day until the battery is depleted When the battery becomes depleted, the only
item that needs to be reset is the time of day and will be indicated by the time of
day flashing All other settings are permanently stored in the nonvolatile memory
If a power loss occurs and the time of day flashes, this indicates that the battery
is depleted The time of day should be reset and the non-rechargeable battery
should be replaced The battery is a 3 Volt Lithium Coin Cell type 2032 and is
readily available at most stores To access battery location, remove front cover
(see diagram on page 18 for battery location).
6 CHECK SALT INDICATOR AND AUDIBLE ALARM: This control valve (not available on CSP and CSPRC twin
models) is equipped with a Low Salt Warning to alert homeowners that the system is operating in a low salt condition
This usually indicates that the salt level in the brine tank is too low to operate properly If “CHECK SALT” appears, there
will usually be an audible alarm that sounds also (if turned on), alerting you to these conditions
To turn off alarm: If the audible alarm sounds due to a low salt condition, press any button on the face of the
control valve to turn off If salt is not added to the brine tank before the next regeneration,
the CHECK SALT indicator will alarm again
IMPORTANT: If you feel that the salt level is adequate (at least 1/3 full) in the brine tank, please contact the dealer
that installed your system for service
7 ERROR MESSAGE: If the word “ERROR” appears and flashes alternately with
the dealer name and phone number, record the ERROR number and your contact
servicing dealer promptly This indicates that the control valve was not able to
function properly
8 BRINE TANK MAINTENANCE AND SALT: Refill the brine tank as necessary,
making sure at least 1/3 of the brine tank is full at all times Without proper salt
levels, the water softener may not operate properly
The manufacturer recommends the use of solar salt for best results The brine tank is manufactured for the use of
solar, pellets or rock salt If pellet or rock salt is used, a cleaning of the brine tank every six months is recommended
CAUTION: With some models the manufacturer does NOT recommend the use of
any resin cleaners, nor placing any resin cleaners into the brine tank.
Furthermore, do not use any salt that indicates it is an iron cleaning salt
or that contains any cleaning additives. This may be harmful to the water
softener and for human consumption. Consult dealer for proper cleaning
instructions and agents.
10
BATTERY REPLACEMENT
ERROR

11
FLUSHING OF SYSTEM:
To flush the system of any debris and air after installation is complete, please perform the following steps:
1 Rotate bypass handles to the bypass mode (see Fig. 2 of page 4)
2 Turn on inlet water and check for leaks in the newly installed plumbing
3 Fully open a cold water faucet, preferable at a laundry sink or bathtub without an aerator
4 Allow water to run until clear to rid pipes of debris which may have occurred during installation
System regeneration sequence is in the following order (If it is desired to change this sequence, please refer to the Dealer
Master Programming Guide or contact the manufacturer)
1) BACKWASH 4) BRINE TANK FILL
2) BRINE and RINSE DOWN 5) END (returns to Standby)
3) RAPID RINSE The system is now ready for filling with water and for testing
1 With the softener in the bypass mode (Fig. 2 on page 4) and the control valve in normal operation where the display
shows either the time of day or the gallons remaining, manually add 8” of water to the regenerant tank
NOTE: If too much water is put into the brine tank during softener start up, it could result in a “salty water” complaint after
the first regeneration
During the first regeneration the unit will draw out the initial volume of brine/regenerant and refill it with the correct preset amount
2 With the softener in bypass mode, press and hold the regen button until the motor starts Release button The display will read
“Pend 0” for about three seconds while the system transfers from one tank to another After the transfer is complete, the valve will
automatically advance to the “Backwash” position Once the valve has stopped in this position, unplug the transformer so that
the valve will not cycle to the next position Open the inlet handle of the bypass valve very slightly, allowing water to fill the tank
slowly in order to expel air from the tank
CAUTION: If water flows too rapidly, there will be a loss of media to the drain.
3 When the water is flowing steadily to the drain, clear and without the presence of air, slowly open the inlet valve Restore
power and momentarily press the regen button to advance the control to the “BRINE” position
4 With the bypass now in diagnostic mode (Fig. 3 on page 4), check to verify that water is being drawn from regenerant tank
with no air leaks or bubbles in the brine line There should be a slow flow to the drain Disconnect brine line from the safety float
valve in the brine tank and check for a vacuum After proper confirmation, reconnect brine line, making sure to tighten securely
5 Momentarily press regen again until the display reads “RINSE” There should be a rapid flow to the drain Unplug transformer
to keep the valve in the “RINSE” position Allow to run until steady, clear and without air While the unit is rinsing, load the
brine tank with water softener salt (refer to page 10, Brine Tank Maintenance and Salt) Restore power
6 Push regen again and the unit will advance to the “Brine Refill” position Check to make sure the brine tank is refilling
The flow rate is usually 5 gpm for all residential and light commercial applications
7 Push next and the unit will return to normal operation
8 Place unit into bypass mode again (see Fig. 2 on page 4) and press and hold the regen button to allow control valve to
transfer to the second tank Follow steps 2-7 to now expel air from this tank
9 When finished expelling air from second tank, return bypass handles to normal operating position (see Fig. 1 on page 4)
The unit is now online and soft water is available for use
10 CONDITIONING OF MEDIA (To flush any remaining debris and air from the system):
1 Fully open a cold water faucet, preferably at a laundry sink or bathtub without an aerator
2 Wait two to three minutes or until water runs clear, then turn water off
3 Turn on hot water and check for air, then turn water off after air is discharged
11 SANITIZING OF UNIT UPON INSTALLATION AND AFTER SERVICE (At this time, it is advised to sanitize the softener):
1 Open brine tank and remove brine well cover
2 Pour 1 oz of household bleach into the softener brine well
3 Replace brine well cover
NOTE: Avoid pouring bleach directly onto the safety float components in the brine well
Unit sanitizing will be complete when the first cycle is run and the bleach is flushed from the softener
12 Check time of day Start-up is now complete
START-UP INSTRUCTIONS:

12
PROBLEM CAUSE CORRECTION
1. No display on
PC board
A No power at electric outlet A Repair outlet or use working outlet
B Control valve power adapter not plugged into
outlet or power cord end not connected to PC
board connection
B Plug power adapter into outlet or connect
power cord end to PC board connection
C Improper power supply C Verify proper voltage is being delivered to
PC board
D Defective power adapter D Replace power adapter
E Defective PC board E Replace PC board
F Dead battery F Replace battery
2. PC board does not
display correct time
of day
A Power adapter plugged into electric outlet
controlled by light switch A Use uninterrupted outlet
B Tripped breaker switch and/or tripped GFI B Reset breaker switch and/or GFI switch
C Power outage
C Reset time of day If PC board has battery
back up present the battery may be depleted
See front cover and drive assembly drawing
for instructions
D Defective PC board D Replace PC board
3. Display does not
indicate that water is
flowing. Refer to user
instructions for how the
display indicates water
is flowing.
A Bypass valve in bypass position A Turn bypass handles to place bypass in
service position
B Meter is not connected to meter connection on
PC board
B Connect meter to three pin connection labeled
METER on PC board
C Restricted/stalled meter turbine C Remove meter and check for rotation or
foreign material
D Meter wire not installed securely into three
pin connector
D Verify meter cable wires are installed securely
into three pin connector labeled METER
E Defective meter E Replace meter
F Defective PC board F Replace PC board
4. Control valve
regenerates at wrong
time of day
A Power outage
A Reset time of day If PC board has battery
back up present the battery may be depleted
See front cover and drive assembly drawing
for instructions
B Time of day not set correctly B Reset to correct time of day
C Time of regeneration set incorrectly C Reset regeneration time
D Control valve set at “on 0” (immediate
regeneration)
D Check programming setting and reset to
NORMAL (for a delayed regen time)
E Control valve set at “NORMAL + on 0”
(delayed and/or immediate)
E Check programming setting and reset to
NORMAL (for a delayed regen time)
5. Time of day flashes on
and off A Power outage
A Reset time of day If PC board has battery
back up present the battery may be depleted
See diagram on page 18 for battery location
6. Control valve does not
regenerate automatically
when the correct button(s)
is depressed and held.
A Broken drive gear or drive cap assembly A Replace drive gear or drive cap assembly
B Broken piston rod B Replace piston rod
C Defective PC board C Defective PC board
TROUBLESHOOTING GUIDE:

13
7. Control valve does not
regenerate automatically
but does when the
correct button(s) is
depressed and held.
A Bypass valve in bypass position A Turn bypass handles to place bypass in
service position
B Meter is not connected to meter connection on
PC board
B Connect meter to three pin connection labeled
METER on PC board
C Restricted/stalled meter turbine C Remove meter and check for rotation or
foreign material
D Incorrect programming D Check for programming error
E Meter wire not installed securely into three
pin connector
E Verify meter cable wires are installed securely
into three pin connector labeled METER
F Defective meter F Replace meter
G Defective PC board G Replace PC board
8. Hard or untreated
water is being
delivered
A Bypass valve is open or faulty A Fully close bypass valve or replace
B Media is exhausted due to high water usage B Check program settings or diagnostics for
abnormal water usage
C Meter not registering C Remove meter and check for rotation or
foreign material
D Water quality fluctuation D Test water and adjust program
values accordingly
E No regenerant or low level of regenerant in
regenerant tank E Add proper regenerant to tank
F Control fails to draw in regenerant F Refer to Troubleshooting Guide number 12
G Insufficient regenerant level in regenerant tank
G Check refill setting in programming Check
refill flow control for restrictions or debris and
clean or replace
H Damaged seal/stack assembly H Replace seal/stack assembly
I Control valve body type and piston type
mix matched
I Verify proper control valve body type and
piston type match
J Fouled media bed J Replace media bed
9. Control valve uses too
much regenerant
A Improper refill setting A Check refill setting
B Improper program settings
B Check program setting to make sure
they are specific to the water quality and
application needs
C Control valve regenerates frequently C Check for leaking fixtures that may be
exhausting capacity or system is undersized
10. Residual regenerant
being delivered to
service
A Low water pressure A Check incoming water pressure – water
pressure must remain at minimum of 25 psi
B Incorrect injector size B Replace injector with correct size for
the application
C Restricted drain line C Check drain line for restrictions or debris
and clean
11. Excessive water in
regenerant tank
A Improper program settings A Check refill setting
B Plugged injector B Remove injector and clean or replace
C Drive cap assembly not tightened in properly C Retighten the drive cap assembly
D Damaged seal/stack assembly D Replace seal/stack
E Restricted or kinked drain line E Check drain line for restrictions or debris and
or unkink drain line
F Plugged backwash flow controller F Remove backwash flow controller and clean
or replace
G Missing refill flow controller G Replace refill flow controller
PROBLEM CAUSE CORRECTION

14
TROUBLESHOOTING GUIDE cont’d:
12. Control valve fails to
draw in regenerant
A Injector is plugged A Remove injector and clean or replace
B Faulty regenerant piston B Replace regenerant piston
C Regenerant line connection leak C Inspect regenerant line for air leak
D Drain line restriction or debris cause excess
back pressure
D Inspect drain line and clean to
correct restriction
E Drain line too long or too high E Shorten length and or height
F Low water pressure F Check incoming water pressure – water
pressure must remain at minimum of 25 psi
13. Water running to
drain
A Power outage during regeneration
A Upon power being restored control will finish
the remaining regeneration time Reset time of
day If PC board has battery back up present
the battery may be depleted See front cover
and drive assembly drawing for instructions
B Damaged seal/stack assembly B Replace seal/stack assembly
C Piston assembly failure C Replace piston assembly
D Drive cap assembly not tightened in properly D Retighten the drive cap assembly
14. E1, Err – 1001,
Err – 101 =
Control unable
to sense motor
movement
A Motor not inserted fully to engage pinion,
motor wires broken or disconnected
A Disconnect power, make sure motor is fully
engaged, check for broken wires, make sure
two pin connector on motor is connected to the
two pin connection on the PC board labeled
MOTOR Press NEXT and REGEN buttons for
3 seconds to resynchronize software with piston
position or disconnect power supply from PC
board for 5 seconds and then reconnect
B PC board not properly snapped into drive bracket
B Properly snap PC board into drive bracket and
then Press NEXT and REGEN buttons for 3
seconds to resynchronize software with piston
position or disconnect power supply from PC
board for 5 seconds and then reconnect
C Missing reduction gears C Replace missing gears
15. E2, Err – 1002, Err –
102 = Control valve
motor ran too short
and was unable to
find the next cycle
position and stalled
A Foreign material is lodged in control valve
A Open up control valve and pull out piston
assembly and seal/stack assembly for
inspection Press NEXT and REGEN buttons for
3 seconds to resynchronize software with piston
position or disconnect power supply from PC
board for 5 seconds and then reconnect
B Mechanical binding
B Check piston and seal/stack assembly, check
reduction gears, check drive bracket and main
drive gear interface Press NEXT and REGEN
buttons for 3 seconds to resynchronize software
with piston position or disconnect power supply
from PC board for 5 seconds and then reconnect
C Main drive gear too tight
C Loosen main drive gear Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds
and then reconnect
D Improper voltage being delivered to PC board
D Verify that proper voltage is being supplied
Press NEXT and REGEN buttons for 3 seconds
to resynchronize software with piston position
or disconnect power supply from PC board for
5 seconds and then reconnect
PROBLEM CAUSE CORRECTION

15
PROBLEM CAUSE CORRECTION
16. E3, Err – 1003, Err –
103 = Control valve
motor ran too long
and was unable to find
the next cycle position
A Motor failure during a regeneration
A Check motor connections then Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds
and then reconnect
B Foreign matter built up on piston and stack
assemblies creating friction and drag enough
to time out motor
B Replace piston and stack assemblies Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position
or disconnect power supply from PC board
for 5 seconds and then reconnect
C Drive bracket not snapped in properly and out
enough that reduction gears and drive gear do
not interface
C Snap drive bracket in properly then Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position
or disconnect power supply from PC board
for 5 seconds and then reconnect
17. E4, Err – 1004, Err –
104 = Control valve
motor ran too long
and timed out trying
to reach home position
A Drive bracket not snapped in properly and out
enough that reduction gears and drive gear do
not interface
A Snap drive bracket in properly then Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position
or disconnect power supply from PC board
for 5 seconds and then reconnect
18. Err -1006, Err – 106,
Err - 116 = MAV/
SEPS/ NHBP/ AUX
MAV valve motor ran
too long and unable
to find the proper
park position
Motorized Alternating
Valve = MAV
Separate Source = SEPS
No Hard Water Bypass
= NHBP
Auxiliary MAV = AUX
MAV
A Control valve programmed for ALT A or B,
nHbP, SEPS, or AUX MAV with out having
a MAV or NHBP valve attached to operate
that function
A Press NEXT and REGEN buttons for 3 seconds
to resynchronize software with piston position
or disconnect power supply from PC board for
5 seconds and then reconnect Then reprogram
valve to proper setting
B MAV/NHBP motor wire not connected to
PC board
B Connect MAV/NHBP motor to PC board two
pin connection labeled DRIVE Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds
and then reconnect
C MAV/NHBP motor not fully engaged with
reduction gears
C Properly insert motor into casing, do not force
into casing Press NEXT and REGEN buttons for
3 seconds to resynchronize software with piston
position or disconnect power supply from PC
board for 5 seconds and then reconnect
D Foreign matter built up on piston and stack
assemblies creating friction and drag enough
to time out motor
D Replace piston and stack assemblies Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position
or disconnect power supply from PC board
for 5 seconds and then reconnect
19. Err – 1007, Err – 107,
Err - 117 = MAV/
SEPS/NHBP/AUX
MAV valve motor
ran too short (stalled)
while looking for
proper park position
Motorized Alternating
Valve = MAV
Separate Source = SEPS
No Hard Water Bypass
= NHBP
Auxiliary MAV = AUX
MAV
A Foreign material is lodged in
MAV/NHBP valve
A Open up MAV/NHBP valve and check piston
and seal/ stack assembly for foreign material
Press NEXT and REGEN buttons for 3 seconds
to resynchronize software with piston position
or disconnect power supply from PC board for
5 seconds and then reconnect
B Mechanical binding
B Check piston and seal/stack assembly, check
reduction gears, drive gear interface, and c
heck MAV/NHBP black drive pinion on motor
for being jammed into motor body Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position or
disconnect power supply from PC board for 5
seconds and then reconnect

Release locking tabs
from each side to
remove back plate.
16
TRANSFER CAP ASSEMBLIES SERVICE INSTRUCTIONS
1 The backplate of the control valve must
first be removed to allow access to the
transfer cap assembly
2 Hold slight downward pressure on the
top left corner of the backplate while
using a thin flat screwdriver or knife
blade to push in on the locking tabs
This will release the backplate and it
will twist to the left of the valve body
3 For removal of the drive motor side
(Fig. 3), remove the drive cover
assembly to access the motorized drive
The drive motor can be removed by
pressing the spring clip loop to the right
then rotating the motor a quarter turn
Pull outward to remove the motor from
the reducing gear cover assembly
4 Remove the three Phillips head stainless
steel screws that retain the reducing
gear cover to the drive cap
5 Once the cover is removed, there will be access to the reducing drive gears Simply slide them off of the gear axles, then
inspect and check them (there are three small black gears with foil decals and one larger black reducing gear)
6 Remove the large white drive gear from the stainless steel drive shaft To remove the large white transfer drive gear, firmly
grab the outside edge of the gear and pull it outward away from the control valve assembly
7 Use a 5/32" or 4mm allen wrench to remove the ¼-#20 screws (six screws on each side) that retain the transfer drive cap
assemblies on both sides of the valve
8 Once the screws are removed from retaining the inlet side transfer valve cap and the outlet drive motor transfer cap from the
control valve, the cap will spring out away from the valve body At this point the transfer discs may be removed by pulling
the discs outward off of the shaft away from the valve body With the disc out, inspect the flat surface area to be sure it is
clean, smooth and free of any debris or scratches Note that the disc is keyed to the drive shaft so that it will only assemble
in one orientation (See parts diagram on page 20.)
9 The transfer discs may be chemically cleaned with a dilute sodium bisulfate
solution (Iron Out), vinegar or just wiped with a soft clean cloth
10 To remove seals, gently pull out on the outer lip of the seal to lift the seal out from
its cavity being careful not to damage the face surface of the seal
11 To reassemble, reseat seals into the seal cavity of the control valve body being
sure that the lip of the seal is facing outward See Fig. 2.
12 With seals in place, put a thin film of Dow #7 silicone grease on the tops of
the seals and the flat surface of the discs
CAUTION: Do not use Vaseline, petroleum jelly or any other hydrocarbon lubricants on
plastic components or O-rings as they will cause damage to the material and
can potentially cause leaks in the system.
13 Prior to reinstalling the discs, the drive shaft should be removed and the O-rings cleaned, inspected and lubricated with
Dow #7 silicone grease The shaft can now be installed into the disc prior to installation
SERVICE INSTRUCTIONS:
FIGURE 1
FIGURE 2

17
14 With the outlet disc assembled to the shaft, the orientation of the shaft to inlet disc can be assured by installing the set
with the through hole on the outlet disc at the 6 o’clock position The easiest way to reassemble is to remove both disc
drives and assemble the outlet side first Then each disc can be fitted on the shaft individually At this point the transfer
valve cap assemblies can be reinstalled
NOTE: Both transfer caps only mount in one orientation Prior to installation of cap assembly, be sure to check that the
stainless steel spring and the plastic spring support is in place and attached to the inside of the assembly
15 Wipe the outside edge of the O-ring on the cap and the inside mating area of the valve with a clean cloth and reapply
a thin layer of Dow #7 silicone grease
16 Noting the one possible orientation of the transfer drive cap, use
one hand to press in and support the transfer drive cap while
using the opposing hand to start two screws in, one on the top
and one opposing it on the bottom Tighten the screws evenly
so that the cap seats the O-ring without getting pinched or
damaged Screws should only be hand tightened with a 5/32”
or 4mm allen wrench DO NOT OVER TIGHTEN SCREWS.
NOTE: Take care to be certain the meter cable doesn’t
get under the drive cap while tightening as it will result in
damaging the cable
17 Position the large white drive gear with the “A”
pointing toward the one o’clock position and
then press it onto the stainless steel drive shaft,
making sure it snaps and locks into position
NOTE: The white drive gear is splined to the drive
shaft and will only assemble in one orientation
Because of this, it is not necessary that the discs and
gear be exactly positioned The positioning needs to
be approximate but they have to fit on the shaft
18 Install the larger black reducing gear onto the stainless
steel shaft, then install the remaining smaller reducing
gears from left to right
19 Reinstall the grey reducing gear cover over the gears and
affix with the three stainless steel screws
20 Reinstall the drive motor by pressing the spring clip loop to the
right, then rotate the motor as you are inserting it so the gear
of the motor meshes properly with the reducing gears
21 Release the spring clip loop and rotate the motor until the motor housing engages with the plastic nub inside the housing
that holds the motor in place, making sure that the top of the motor is flush with the top of the grey gear housing
22 Press the drive motor wires down into the strain relief of the drive cap
23 Reinstall the cover assembly
After completing any valve maintenance involving the valve drive assembly or the transfer drive assembly, press and hold
the next and regen buttons simultaneously for three to five seconds to perform a soft reset which will synchronize the control
valves positions
FIGURE 3

REPLACEMENT PARTS:
18
4
1
23
5
6
7
FRONT COVER AND DRIVE ASSEMBLY
Item No. Part No. Description Qty.
1CV3837-01XB TotalCare cover 1
CV3837-01 CareSoft Pro cover 1
2 CV3107-1 Motor 1
3CV3106-1 Drive bracket & spring clip 1
4 CV4050WB PC board (used on chlorine generator models) 1
CV4062WX PC board (standard) 1
5CV3110 Drive gear, 12 x 36 3
6 CV3109 Drive gear cover 1
7CV3002CC Drive assembly, CC -
not shown
CV3526 Transformer, 110V-15V, DC (used on chlorine generator models) 1
CV3186 Transformer, 110V-12V, AC (standard) 1
CV3543 Optional weather cover 1
NOTE: Battery Location

19
REPLACEMENT PARTS:
4
2
3
5
1
14
PISTON ASSEMBLY
Item No. Part No. Description Qty.
1 CV3005 1” spacer stack assembly 1
2 CV3004 Drive cap assembly 1
3CV3135 O-ring 228 1
4
CV3011 1” piston assembly downflow 1
CV3011-01 1” piston assembly upflow 1
CV3407 125” piston assembly downflow 1
5CV3174 Regenerant piston 1
14 CV3541 Drive backplate 1

20
REPLACEMENT PARTS:
See pages
22-23
This manual suits for next models
8
Table of contents
Other Water Care Water Dispenser manuals

Water Care
Water Care PT-5 User manual

Water Care
Water Care Evolve EV1-1044TW Service manual

Water Care
Water Care CareSoft Series Service manual

Water Care
Water Care CareSoft Series Service manual