Operating and maintenance instructions
SDFC Series for lay in ceiling
Product Description
SDFC Fixed Blade Swirl Diffusers
Tools Required
1 x Large cross head screwdriver
1 x Pop riveter
1 x ø3.5mm drill bit
1 x Power drill
Plenum Installation:
1- ,QVWDOO WKH SOHQXP ER[ SULRU WR ¿WWLQJ WKH FHLOLQJ
grid by suspending it from its mounting holes with
drop rods (supplied by others). When the grid has
EHHQ ¿WWHG FHQWUDOLVH WKH SOHQXP LQ ERWK GLUHFWLRQV
ZLWKLQ WKH RSHQLQJ ZKHUH WKH GLIIXVHU LV WR EH ¿WWHG
(Figures 1).
2- 2QFH\RXDUHVDWLV¿HGZLWKLWVDOLJQPHQWZLWKLQWKH
FHLOLQJ JULG UDLVH WKH SOHQXP ER[ DERYH WKH JULG WR
DOORZVXI¿FLHQWVSDFHWRLQVWDOOWKHWLOHFigures 2).
3- 7DNHDFHLOLQJWLOHPDUN RXW WKH UHTXLUHGGLIIXVHU
position then cut out the appropriate clearance hole
size (Figures 3). The recommended hole sizes are as
follows:
4- /RFDWHRQHHQGRIWKHWLOHLQWRWKHFHLOLQJRSHQLQJ
and in a sliding motion move it to the far end of the
opening (Figures 4).
Figure 1: Centralise plenum
Figure 2: Raise plenum box
Figure 3: Cut clearance hole in tile
Figure 4: Slide diffuser into opening
Model Cutout Size
SDFC-125 160
SDFC-160 200
SDFC-200 250
SDFC-250 300
SDFC-315 370
SDFC-400 460
Refer to table for
recommended size

3
www.waterloo.co.uk Tel: +44 (0) 1622 711500
Operating and maintenance instructions
SDFC Series for lay in ceiling
Plenum Installation:
5- 2QFHWKHWLOHLVSRVLWLRQHGORZHULWLQWRWKHRSHQLQJ
HQVXULQJWKDWLWLV¿UPO\VHDWHGDJDLQVWWKHWHHEDUVRI
the ceiling grid (Figures 5).
6- Lower the plenum box into the opening in the
WLOHHQVXULQJWKDWWKHERWWRPRIWKHSOHQXPFROODULV
between 20 and 25mm from the tile face (Figures 6).
'RQRWWLJKWHQWKHGURSURGORFNQXWVDWWKLVWLPHDV
VRPHDGMXVWPHQWPD\EHUHTXLUHG
7- 2QFHWKHSOHQXPLVSRVLWLRQHGRIIHUXSWKHGLIIXVHU
into the tile opening making sure that the stack on the
rear of the diffuser is correctly located in the plenum
mounting collar (Figures 7 7DNH WKH ¿[LQJ VFUHZ
IURP WKH ¿WWLQJ NLW VXSSOLHG UHPRYH LWV SODVWLF FDS
and secure the diffuser to the plenum mounting bar
using hand tools only as shown in (Figures 7a). Take
care not to over tighten the screw as this could distort
to the diffuser face.
Figure 5: Lower diffuser into position
Figure 7: Offer diffuser up into opening
Figure 6: Lower plenum into opening
Figure 7a: Screw diffuser to plenum
20 to 25mm

4
www.waterloo.co.uk Tel: +44 (0) 1622 711500
Operating and maintenance instructions
SDFC Series for lay in ceiling
Plenum Installation:
8- &OLSWKHSODVWLFFDSEDFNRQWRWKHKHDGRIWKH¿[LQJ
screw (Figures 8).
9- This operation may cause the tile to be lifted off the
FHLOLQJJULGFUHDWLQJDJDSSLQJHIIHFWRUDOWHUQDWLYHO\
the diffuser may not pull all the way up to the tile
IDFH,IWKLVRFFXUVDGMXVWWKHKHLJKWRIWKHSOHQXPE\
raising or lowering the assembly using the lock nuts
on the plenum drop rods until the desired effect is
DFTXLUHGFigures 9 and Figures 9a).
Figure 9a: Raise plenum to close gap
Figure 9: Lower plenum to close gap
)LJXUH5H¿WFDSRQ¿[LQJVFUHZ
,IµJDSSLQJ¶KHUHORZHUWKHSOHQXP
box on the drop rods
,IµJDSSLQJ¶KHUHUDLVHWKHSOHQXP
box on the drop rods

5
www.waterloo.co.uk Tel: +44 (0) 1622 711500
Operating and maintenance instructions
SDFC Series for lay in ceiling
Duct Mount Installation
An alternative method of installing this range of
diffusers is the use of a steel duct mount collar.
7KLV DOORZV ERWK ULJLG DQG ÀH[LEOH GXFWZRUN WR EH
connected directly to the rear of the diffuser.
7KHVH GXFW PRXQWV DUH VXSSOLHG WR RUGHU DQG WKH
installation instructions are as follows:
1- Take the diffuser and place it face down on the
WDEOHWDNLQJFDUHWROD\LWRQVRPHWKLQJWRSURWHFWWKH
SDLQW¿QLVK
2- Orientate the duct collar so that its mounting bar
µ8¶ FKDQQHO LV RSHQ WR WKH WRS WKHQ SODFH WKH FROODU
over the rear stack of the diffuser. Take care to ensure
that the stack is positively located within the collar
(Figures 10).
3- 5HPRYH WKH SODVWLF FDS IURP WKH ¿[LQJ VFUHZ
supplied. Stand the diffuser on edge whilst still holding
WKH GXFW FROODU LQ SODFH WKHQ LQVHUW WKH ¿[LQJ VFUHZ
and secure the diffuser to the duct collar using hand
tools only (Figures 11). Take care not to over tighten
the screw as this could distort to the diffuser face.
4- 5H¿W WKH SODVWLF FDS RQWR WKH KHDG RI WKH ¿[LQJ
screw.
5- Lay the cut tile over the stack of the diffuser and
centralise its position. Take the ceiling mounting
brackets (Figures 12DQG¿[WKHPDURXQGWKHRXWVLGH
RIWKHGXFWFROODUDWLQWHUYDOVRUDVUHTXLUHGXVLQJ
pop rivets or self tapping screws as shown in (Figures
12a :KHQ SRVLWLRQLQJ WKHVH EUDFNHWV HQVXUH WKDW
WKHUH LV VXI¿FLHQW WHQVLRQ RQ WKHP WR SLQFK WKH 7LOH
and prevent any movement of the diffuser. Please
QRWHWKDWWKHVHEUDFNHWVDUHVXSSOLHGXSRQUHTXHVW
Figure 10: Position duct collar on stack
Figure 12a: Fit mounting brackets
Figure 11: Screw diffuser to duct collar
Figure 12: Ceiling mounting bracket

6
www.waterloo.co.uk Tel: +44 (0) 1622 711500
Operating and maintenance instructions
SDFC Series for lay in ceiling
Figure 13: Slide into ceiling grid
Figure 13a: Lower diffuser into place
Duct Mount Installation
6- Locate one end of the tile and diffuser into the
FHLOLQJRSHQLQJDQGLQDVOLGLQJPRWLRQPRYHLWWRWKH
far end of the opening (Figures 13).
7- 2QFH WKH GLIIXVHU LV SRVLWLRQHG ORZHU LW LQWR WKH
RSHQLQJHQVXULQJWKDWLWLV¿UPO\VHDWHGDJDLQVWWKH
tee bars of the ceiling grid. (Figures 13a).
8- Rigid Ductwork
a- Lower the ductwork on the drop rods to allow
it to slide over the exterior of the duct collar
(Figures 14). Anchor it in position using the lock
nuts on the supporting drop rods.
b- Secure the ductwork by drilling through it and
WKHGXFWFROODUDERYHWKHVZDJHOLQHWKHQULYHWLQJ
or screwing them in place (Figures 15). Do not
XQGHUDQ\FLUFXPVWDQFHV¿[WKHGXFWZRUNEHORZ
the swage line as damage to the diffuser may
occur.
9- Flexible Ductwork
3ODFHWKHRSHQHQGRIWKHÀH[LEOHGXFWZRUNRYHUWKH
outside of the duct collar and secure in place using a
worm drive hose clip.
Cleaning and Maintenance:
7R FOHDQ XVH ZDUP VRDS\ ZDWHU DQG D GDPS FORWK
Wipe down the blades and face of the diffuser and
leave to dry.
Figure 15: Secure ductwork in place
Figure 14: Lower the ductwork
Drill and secure
DVUHTXLUHG
Do not drill below this swageline or
damage to the diffuser could occur

7
www.waterloo.co.uk Tel: +44 (0) 1622 711500
Waterloo Product Range
GRILLES
$FRPSOHWHUDQJHRISURGXFWVVXLWDEOHIRUDOOZDOOFHLOLQJDQGÀRRUDSSOLFDWLRQV
0RVWJULOOHVDUHPDGHIURPDOXPLQLXPDQGKDYHDUDQJHRI¿[HGRUPRYHDEOH
blades designed to give performance whilst remaining aesthetically pleasing
WRWKHH\H*ULOOHVDUHPDGHWRFXVWRPHUVSHFL¿HGVL]HVDQGFRORXUV330*
standard colour PPM9010 (20% Gloss White). The range is complemented by
the Aircell range of polymer Grilles.
DIFFUSERS
'HVLJQHGWREHLQVWDOOHGLQYDULRXVFHLOLQJV\VWHPVZHKDYHDFRPSOHWHUDQJH
WRVXLWERWKSHUIRUPDQFHDQGDHVWKHWLFDOUHTXLUHPHQWV0RVWGLIIXVHUVDUHPDGH
from aluminium and can be ordered with or without plenum boxes for easy
GXFW ZRUN 'LIIXVHUV FDQ EH RUGHUHG LQ FXVWRPHU VSHFL¿HG FRORXUV 330*
standard colour is PPM 9010 (20% Gloss White). This range is complemented
by the Aircell range of polymer Diffusers.
DISPLACEMENT
$IXOOUDQJHRIUHFHVVHGVHPLUHFHVVHGÀRRUZDOODQGFRUQHUXQLWVSURYLGLQJ
KLJK YHQWLODWLRQ HI¿FLHQF\ DQG H[FHOOHQW FRPIRUW 7KH YHU\ ORZ SUHVVXUH
LQYROYHGDOVRRIIHUTXLHWLQVWDOODWLRQV'LVSODFHPHQWXQLWVDUHDYDLODEOHDVZDOO
RUÀRRUPRXQWHGRULQGHHGLQWHJUDWHGZLWKLQWKHDUFKLWHFWXUDOGHVLJQ
EXTERNAL LOUVRES
$TXDOLW\UDQJHRISURGXFWVIRUH[WHUQDOZDOODSSOLFDWLRQV0DGHIURPDOXPLQLXP
with birdscreen or insect screen options. All louvres are made to customer
VSHFL¿HGVL]HVDQG330*FRORXUVVWDQGDUGFRORXULV330
AIR VOLUME CONTROL DAMPERS
Pressure independent Variable Air Volume and Constant Air Volume dampers
made from zintec plate. Most volume dampers are regulated with an electronic
PRWRUDQGVHQVRUVDQGDUHFDOLEUDWHGWRFXVWRPHUVSHFL¿FDWLRQVEHIRUHGHOLYHU\
7KH&RQVWDQW$LU9ROXPHGDPSHUUHTXLUHVQRSRZHUVRXUFHDVLWLVFRQWUROOHG
via a mechanical device and calibrated before delivery. All volume dampers can
be ordered with a single or double (insulation) skin.
ACTIVE AND PASSIVE CHILLED BEAMS
7KH¿QHVWTXDOLW\UDQJHRIKLJKRXWSXWDFWLYHEHDPVXVHGIRUYHQWLODWHGKHDWLQJ
and cooling applications. These units have 4 pipe coils to allow heating and
FRROLQJFLUFXLWVWRUXQVLPXOWDQHRXVO\JLYLQJFRQVWDQWDQGUHVSRQVLYHFRQWURO
The design allows a large optimum capacity and also allows the customer to
specify the nozzle type and pitch for individual circumstances.
$FWLYHEHDPVDUHPDGHIURPVWHHOWRDODUJHUDQJHRIFXVWRPHUVSHFL¿HGVL]HV
DQGDVVXFKDUHVXLWDEOHIRUYDULRXVGLIIHUHQWFHLOLQJV\VWHPV6WDQGDUG¿QLVKLV
330KRZHYHURWKHU330*FRORXUVDUHDYDLODEOHRQUHTXHVW
standard
colour
PPM9010
(20%
Gloss
White
the Aircell ran
ge
of
pol
yme
rG
rilles.
e
Aircell
range
of
pol
yme
me
me
rG
r G
r G
r G
ril
ril
ril
ril
les
les
les
le
.
)
g
p
.
E
E
RS
t
l
k
¿HG
VL]HV
DQG
330*
FRORXUV
V
EXTERNAL LOUVRES
Waterloo Product Range

All products conform to the Terms and Conditions of Waterloo Air
3URGXFWVSOFDFRS\RIZKLFKDUHDYDLODEOHXSRQUHTXHVW'XHWRRXU
FRQWLQXRXVUHVHDUFKDQGGHYHORSPHQWSURJUDPPH:DWHUORR$LU
Products plc reserve the right to alter products and prices without prior
QRWL¿FDWLRQ
Copyright Waterloo Air Products plc 2019
:DWHUORRGHFODUHWKDWDWWKHWLPHRISULQWDOOSURGXFWVDUHLQ
DFFRUGDQFHZLWKUHOHYDQWGLUHFWLYHVDVLGHQWL¿HGE\+(9$&
and other European Organisations and will display the
&(0DUNLQJZKHUHUHTXLUHG
Waterloo Air Products plc
+HDG2I¿FH
0LOOV5RDG$\OHVIRUG
0DLGVWRQH.HQW0(1%
Tel: +44 (0)1622 711 500
Fax: +44 (0)1622 710 648
internet: www.waterloo.co.uk
1RUWKHUQ2I¿FH
+\GH3DUN+RXVH&DUWZULJKW6WUHHW
1HZWRQ+\GH6.(+
Tel: +44 (0)161 367 1264
Fax: +44 (0)161 367 1262
internet: www.waterloo.co.uk
March 2019
FM 27823 EMS 590755
This manual suits for next models
6
Table of contents
Other Water-Loo Fan manuals
Popular Fan manuals by other brands

Home Decorators Collection
Home Decorators Collection WINDWARD IV Use and care guide

Caframo
Caframo SEEKR Bora 748 operating instructions

Maxxair
Maxxair MAXXFAN Replacement instructions

Lasko
Lasko T42700 instruction manual

Revolutions
Revolutions Sprint owner's manual

Flexit
Flexit Pro7 User and installation manual