Water-Loo SDFC-125 Manual

SDFC Series for Plasterboard ceiling
Operating and Maintenance

2
www.waterloo.co.uk Tel: +44 (0) 1622 711500
Operating and maintenance instructions
SDFC Series for Plasterboard ceiling
Product Description
SDFC Fixed Blade Swirl Diffusers
Tools Required
1 x Large cross head screwdriver
1 x Pop riveter
1 x ø3.5mm drill bit
1 x Power drill
Plenum Installation:
1- Install the plenum box in its desired position prior to
¿WWLQJRIWKHFHLOLQJE\VXVSHQGLQJLWIURPLWVPRXQWLQJ
KROHV ZLWK GURS URGV VXSSOLHG E\ RWKHUV 5DLVH RU
lower the plenum as required to give a dimension of
20 to 25mm from the proposed ceiling face (Figures
12QFH\RXDUHKDSS\ZLWKLW¶VSRVLWLRQWKHQVHFXUH
the plenum in place using the lock nuts on the drop
rods.
2- After the ceiling has been installed, mark out the
required diffuser position then cut out the appropriate
clearance hole size (Figures 27KHUHFRPPHQGHG
hole sizes are as follows:
3- Offer up the diffuser into the ceiling opening
making sure that the stack on the rear of the diffuser
LV FRUUHFWO\ ORFDWHG LQ WKH SOHQXP PRXQWLQJ FROODU
(Figures 3
7DNH WKH ¿[LQJ VFUHZ IURP WKH ¿WWLQJ NLW VXSSOLHG
remove its plastic cap and secure the diffuser to the
SOHQXPPRXQWLQJEDUXVLQJKDQGWRROVRQO\DVVKRZQ
in(Figures 3a
7DNHFDUHQRWWRRYHUWLJKWHQWKHVFUHZDVWKLVFRXOG
distort to the diffuser face.
Figure 1: Install plenum box
Figure 2: Cut out clearance hole
Figure 3: Offer up diffuser to ceiling opening
Figure 3a: Screw diffuser in place
20 to 25mm
Proposed ceiling face
Model Cutout Size
SDFC-125 160
SDFC-160 200
SDFC-200 250
SDFC-250 300
SDFC-315 370
SDFC-400 460
5HIHUWRWDEOHIRUUHFRPPHQGHGFXWRXWVL]H

3
www.waterloo.co.uk Tel: +44 (0) 1622 711500
Operating and maintenance instructions
SDFC Series for Plasterboard ceiling
Plenum Installation:
4- &OLSWKHSODVWLFFDSEDFNRYHUWKHKHDGRIWKH¿[LQJ
screw (Figures 4
Figure 4: Fit plastic cap over screw
Figure 5: Insert collar in ductwork
Figure 6: Position duct above the proposed ceiling
face location
Duct mount
bar this end
20 to 25mm
Proposed ceiling face position
Duct Mount Installation
An alternative method of installing this range of
diffusers is the use of a steel duct mount collar.
7KLV DOORZV ULJLG GXFWZRUN WR EH FRQQHFWHG GLUHFWO\
WR WKH UHDU RI WKH GLIIXVHU 7KHVH GXFW PRXQWV DUH
supplied to order, and the installation instructions are
as follows:
1- 3ULRUWRWKHLQVWDOODWLRQRIWKHGXFWZRUN¿WWKHGXFW
mount collar into the vertical section of the ductwork,
E\¿UVWRULHQWDWLQJWKHFROODUVRWKDWLW¶VPRXQWLQJEDU
µ8¶FKDQQHOLVRSHQWRWKHEDVHRIWKHGXFWZRUN
2- Slide the collar up inside the ductwork until the end
of the ductwork is level with the top of the swage line
(Figures 56HFXUHWKHFROODUWRWKHGXFWZRUNE\SRS
riveting or screwing them together (Figures 5a
3- Install the ductwork in its desired position prior to
¿WWLQJ RI WKH FHLOLQJ E\ VXVSHQGLQJ LW IURP WKH ÀRRU
VODEZLWKGURSURGVVXSSOLHGE\RWKHUV
4- 5DLVHRUORZHUWKHGXFWZRUNDVUHTXLUHGWRJLYHD
dimension of 20 to 25mm from the bottom of the duct
mount collar to the proposed ceiling face (Figures 6
2QFH\RXDUHKDSS\ZLWKLW¶VORFDWLRQWKHQVHFXUHWKH
ductwork in position using the lock nuts on the drop
rods.
Figure 5a: Secure collar in place
Drill and secure
as required Do not drill below this swageline or
damage to the diffuser could occur

4
www.waterloo.co.uk Tel: +44 (0) 1622 711500
Operating and maintenance instructions
SDFC Series for Plasterboard ceiling
Figure 8a: Screw diffuser to duct collar
)LJXUH5H¿WSODVWLFFDS
Figure 8: Offer diffuser into opening
Figure 7: Cut clearance hole
Duct Mount Installation
5- After the ceiling has been installed, mark out the
required diffuser position then cut out the appropriate
clearance hole size (Figures 7 7KH UHFRPPHQGHG
hole sizes are listed in the plenum installation
instructions.
6- Offer up the diffuser into the ceiling opening
making sure that the stack on the rear of the diffuser is
FRUUHFWO\ORFDWHGLQWKHGXFWPRXQWLQJ&ROODUFigures
8
7DNH WKH ¿[LQJ VFUHZ IURP WKH ¿WWLQJ NLW VXSSOLHG
remove its plastic cap and secure the diffuser to the
SOHQXPPRXQWLQJEDUXVLQJKDQGWRROVRQO\DVVKRZQ
in (Figures 8a
7DNHFDUHQRWWRRYHUWLJKWHQWKHVFUHZDVWKLVFRXOG
distort to the diffuser face.
7- &OLSWKHSODVWLFFDSEDFNRYHUWKHKHDGRIWKH¿[LQJ
screw (Figures 9
Cleaning and Maintenance:
7R FOHDQ XVH ZDUP VRDS\ ZDWHU DQG D GDPS FORWK
Wipe down the blades and face of the diffuser and
OHDYHWRGU\
5HIHUWRWDEOHIRUUHFRPPHQGHG
cut out size

5
www.waterloo.co.uk Tel: +44 (0) 1622 711500
:DWHUORR3URGXFW5DQJH
*5,//(6
$FRPSOHWHUDQJHRISURGXFWVVXLWDEOHIRUDOOZDOOFHLOLQJDQGÀRRUDSSOLFDWLRQV
0RVWJULOOHVDUHPDGHIURPDOXPLQLXPDQGKDYHDUDQJHRI¿[HGRUPRYHDEOH
EODGHV GHVLJQHG WR JLYH SHUIRUPDQFH ZKLOVW UHPDLQLQJ DHVWKHWLFDOO\ SOHDVLQJ
WRWKHH\H*ULOOHVDUHPDGHWRFXVWRPHUVSHFL¿HGVL]HVDQGFRORXUV330*
VWDQGDUGFRORXU330*ORVV:KLWH7KHUDQJHLVFRPSOHPHQWHGE\
WKH$LUFHOOUDQJHRISRO\PHU*ULOOHV
',))86(56
'HVLJQHGWREHLQVWDOOHGLQYDULRXVFHLOLQJV\VWHPVZHKDYHDFRPSOHWHUDQJH
to suit both performance and aesthetical requirements. Most diffusers are made
IURP DOXPLQLXP DQG FDQ EH RUGHUHG ZLWK RU ZLWKRXW SOHQXP ER[HV IRU HDV\
GXFW ZRUN 'LIIXVHUV FDQ EH RUGHUHG LQ FXVWRPHU VSHFL¿HG FRORXUV 330*
VWDQGDUGFRORXULV330*ORVV:KLWH7KLVUDQJHLVFRPSOHPHQWHG
E\WKH$LUFHOOUDQJHRISRO\PHU'LIIXVHUV
',63/$&(0(17
$IXOOUDQJHRIUHFHVVHGVHPLUHFHVVHGÀRRUZDOODQGFRUQHUXQLWVSURYLGLQJ
KLJK YHQWLODWLRQ HI¿FLHQF\ DQG H[FHOOHQW FRPIRUW 7KH YHU\ ORZ SUHVVXUH
involved also offer quiet installations. Displacement units are available as wall
RUÀRRUPRXQWHGRULQGHHGLQWHJUDWHGZLWKLQWKHDUFKLWHFWXUDOGHVLJQ
(;7(51$//2895(6
$TXDOLW\UDQJHRISURGXFWVIRUH[WHUQDOZDOODSSOLFDWLRQV0DGHIURPDOXPLQLXP
with birdscreen or insect screen options. All louvres are made to customer
VSHFL¿HGVL]HVDQG330*FRORXUVVWDQGDUGFRORXULV330
$,592/80(&21752/'$03(56
3UHVVXUHLQGHSHQGHQW9DULDEOH$LU9ROXPHDQG&RQVWDQW$LU9ROXPHGDPSHUV
made from zintec plate. Most volume dampers are regulated with an electronic
PRWRUDQGVHQVRUVDQGDUHFDOLEUDWHGWRFXVWRPHUVSHFL¿FDWLRQVEHIRUHGHOLYHU\
7KH&RQVWDQW$LU9ROXPHGDPSHUUHTXLUHVQRSRZHUVRXUFHDVLWLVFRQWUROOHG
YLDDPHFKDQLFDOGHYLFHDQGFDOLEUDWHGEHIRUHGHOLYHU\$OOYROXPHGDPSHUVFDQ
EHRUGHUHGZLWKDVLQJOHRUGRXEOHLQVXODWLRQVNLQ
$&7,9($1'3$66,9(&+,//('%($06
7KH¿QHVWTXDOLW\UDQJHRIKLJKRXWSXWDFWLYHEHDPVXVHGIRUYHQWLODWHGKHDWLQJ
DQG FRROLQJ DSSOLFDWLRQV 7KHVH XQLWV KDYH SLSH FRLOV WR DOORZ KHDWLQJ DQG
FRROLQJFLUFXLWVWRUXQVLPXOWDQHRXVO\JLYLQJFRQVWDQWDQGUHVSRQVLYHFRQWURO
7KHGHVLJQDOORZVDODUJHRSWLPXPFDSDFLW\DQGDOVRDOORZVWKHFXVWRPHUWR
VSHFLI\WKHQR]]OHW\SHDQGSLWFKIRULQGLYLGXDOFLUFXPVWDQFHV
$FWLYHEHDPVDUHPDGHIURPVWHHOWRDODUJHUDQJHRIFXVWRPHUVSHFL¿HGVL]HV
DQGDVVXFKDUHVXLWDEOHIRUYDULRXVGLIIHUHQWFHLOLQJV\VWHPV6WDQGDUG¿QLVKLV
330KRZHYHURWKHU330*FRORXUVDUHDYDLODEOHRQUHTXHVW
VWD
QGD
UG
FRO
RXU
330
*OR
VV
:KLWH
WKH
$LUFHOO
UDQ
JH
RI
SRO\PH
U
*ULOOHV
H
$LU
FHO
O
UDQJH
RI
SRO
\PH
PH
PH
U
U
U
U
*UL
*UL
*UL
*UL
OOH
OOH
OOH
OO
V
J
S
(
(
5
6
t
l
k
¿HG
VL]HV
DQG
330*
FRORXUV
V
(;7(51$/
/2895(6
:DWHUORR3URGXFW5DQJH

$OOSURGXFWVFRQIRUPWRWKH7HUPVDQG&RQGLWLRQVRI:DWHUORR$LU
3URGXFWVSOFDFRS\RIZKLFKDUHDYDLODEOHXSRQUHTXHVW'XHWRRXU
continuous research and development programme, Waterloo Air
Products plc reserve the right to alter products and prices without prior
QRWL¿FDWLRQ
&RS\ULJKW:DWHUORR$LU3URGXFWVSOF
Waterloo declare that, at the time of print, all products are in
DFFRUGDQFHZLWKUHOHYDQWGLUHFWLYHVDVLGHQWL¿HGE\+(9$&
DQGRWKHU(XURSHDQ2UJDQLVDWLRQVDQGZLOOGLVSOD\WKH
&(0DUNLQJZKHUHUHTXLUHG
Waterloo Air Products plc
+HDG2I¿FH
0LOOV5RDG$\OHVIRUG
0DLGVWRQH.HQW0(1%
7HO
)D[
internet: www.waterloo.co.uk
1RUWKHUQ2I¿FH
+\GH3DUN+RXVH&DUWZULJKW6WUHHW
1HZWRQ+\GH6.(+
7HO
)D[
internet: www.waterloo.co.uk
March 2019
FM 27823 (06
This manual suits for next models
6
Table of contents
Other Water-Loo Fan manuals
Popular Fan manuals by other brands

Hunter
Hunter 41953-01 installation guide

Harbor Breeze
Harbor Breeze PRESTWICK 42868 instructions

Suntec Wellness
Suntec Wellness Klimatronic CoolBreeze 3000 TV instruction manual

Progress Lighting
Progress Lighting AirPro Midvale P250011 installation manual

cecotec
cecotec 05912 instruction manual

Casablanca
Casablanca M6016-01 owner's manual