BVC75-INST Rev. Jun08
TM
Connections
Theinletandoutletportsonthelterhousingareprominentlymarkedwitheitherthewordsorwitharrowsshowing
thedirectionofow.Whenmakingtheconnections,makesurethattheowpathisfollowedcorrectly.
StandardmodelsareprovidedwithNPTpipethreadportsasstatedontheboxorontheproductlabel.When
adaptingtheltertootherpipesizes,thoseadaptingttingsmustbeobtainedfromlocalsources.
Installthelterwhereitwillnotbehitorsubjectedtodirectsunlight,freezing,orotherpotentialabuse.Afterturning
offthesystemwaterpressureanddrainingthesystem,cutoutalengthofpipethatisthelengthofthelterplus
thenecessaryadaptorttings.Usemoderatetorquewhentighteningthettingstoavoidcrackingthelterhead.
Filter Start-Up Procedure
Putthecorrectcartridgeinthelter.CartridgesmaybeobtainedfromyourBlakeWaterSystemsdealer.Secure
thesumptothelterheadbyscrewingtheringnutontotheheadngertight.Ifneeded,carefullyusethewrench
provided.
For valve-in-head housings, models: BVC75 & BVC100
Pressurizetheunitafteritissealed.TurnthevalveknobfromtheONpositiontotheBYPASSposition2-3•
times,oruntilasmallamountofwaterescapesfromtheventunderneaththeknob.Thisventsexcessairfrom
the housing.
SetthevalveknobintheONpositionfornormaloperation.•
Checkforleaksandcorrectifnecessary.Flushtheunitforfteenminutestopurgethelterofairanddebris.•
Operation
For valve-in-head housings, models: BVC75 & BVC100
Valve-in-Headmodelsofferthreepositionsforeaseinoperation:
ONPosition:Thisisthestandardoperatingmodeforthelterinservice.•
BYPASSPosition:Usedtoallowwatertobypassacloggedcartridgetemporarilywhilechangingacartridge.•
OFFPosition:Thisshutsoffowthroughthelterwhenchangingthecartridgeorwheneverowmustbe•
stopped.Donotleaveinthispositionformorethan48hours.
Filter Cartridge Replacement
Changethelterwhen:
Thewaterowdropsduetoclogging.•
Theodororoff-tastereturnsduetothelterreachingitscapacity.•
Aftersixmonthsorwheneveritsefciencyhasdecreased.•
Cartridge Change Procedure
For valve-in-head housings, models: BVC75 & BVC100
RotatethevalveknobtoBYPASSallowingthewatertobypassthecartridgeandventthewaterfromthe•
sump.
Separatethesumpfromthelterheadsbyunscrewingtheringnuttotheleft.Usethewrenchprovidedif•
necessary.
Removetheusedcartridge,inspecttheo-ringforanydamage.Wipetheo-ringcleanandlubricatewithsili-•
cone grease to help future replacement of the cartridge.
GotoFILTERSTART-UPPROCEDUREaboveforthenextsteps.•