14
SOFTWARE VERSION
XXX
xx
TOTAL GALLONS
0
X1K
TOTAL DAYS
970
TOTAL REGENS
190
1
ERROR LOG
101
52
3
Second Level History Screens
Accessed by pressing +and —simultaneously for three seconds.
Once screen changes, press +and —simultaneously again for three seconds.
Non-resettable history.
Displays software version.
Displays total gallons used
by Meter 1 since startup.
Displays total days unit has
been in service.
Displays total regens since startup.
Displays last ten valve errors that occurred.
Scroll through with + or — buttons.
Return to general display
Error Code Error Code Description
101 UNABLE TO START: Valve not sensing valve movement with motor energized.
102 MOTOR STALLED: Valve unable to find next cycle position (stalled).
103 MOTOR RAN TOO LONG: Valve unable to find next cycle position.
104 VALVE HOMING: Valve unable to find Home position.
106 MAV 1 RAN TOO LONG: MAV 1 motor ran too long. Unable to find proper park position.
107 MAV 1 STALLED: MAV 1 motor ran too short. Unable to find proper park position (stalled).
109 INVALID MOTOR STATE: Control can no longer operate properly due to detection of an invalid motor state.
116 MAV 2 RAN TOO LONG: MAV 2 motor ran too long. Unable to find proper park position.
117 MAV 2 STALLED: MAV 2 motor ran too short (stalled). Unable to find proper park position.
201 INVALID REGEN STEP: Control can no longer operate properly due to detection of an invalid
regeneration cycle step. Internal software issue.
204 LEAK DETECTED
402 POWER DOWN MEMORY: Check sum error for operational data and status section of EEPROM memory
- specific type of memory error.
403 PROGRAM MEMORY: Check sum error for programming section of EEPROM memory
- specific type of memory error.
404 DIAGNOSTIC MEMORY: Check sum error for diagnostic section of EEPROM memory
- specific type of memory error.
405 HISTORY MEMORY: Check sum error for history section of EEPROM memory
- specific type of memory error.
406 CONTACT MEMORY: Check sum error for contact screen section of EEPROM memory
- specific type of memory error.
407 STATUS RAM MEMORY
FAILURE:
Control can no longer operate properly due to corrupted data detected in the Operational Data and Status
Section of RAM memory. Once generated, the Error Mode is not entered nor an error displayed, instead
previously stored data (<6 hours old) is used to maintain control operation.
408 DIAGNOSTIC RAM
MEMORY FAILURE:
Control can no longer operate properly due to corrupted data detected in the Operational Data and Status
Section of RAM memory. Once generated, the Error Mode is not entered nor an error displayed, instead
previously stored data (<6 hours old) is used to maintain control operation.
410 CONFIG DOWNLOAD: Configuration file downloaded to the control was not originally uploaded from
another control with the identical software revision.
Error Codes and Descriptions
REMINDER: Press and hold NEXT and REGEN for three seconds to perform a soft reset and clear an error on screen.