WDR WDR Series User manual

WDR and D&N Series Camera
Owner’s Manual
Super Double Scan 3D DNR
www.ltv-cctv.ru
LTV-CDH-821LHW-V2.8-12

Flex IR Vandal Dome Series
TDN Lens, dual power, fan & heater, 36ea ir leds, water-proofe

12
Thank you very much for your purchase.
Please read this manual carefully before attempting to install the device. It contains
useful information for the proper installation of your camera.
INFORMATION-This equipment has been tested and found to comply with limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications.
Operation of this equipment in a residential area may cause harmful
interference in which case the user will be required to correct the interference at
his own expense.
WARNING-Changes or modifications not expressly approved by the manufacturer
could void the user’s authority to operate the equipment.
To prevent electric shock and risk of fire hazards:WARNING-
1) Do NOT use power sources other than that specified.
2) Do NOT expose this appliance to rain or moisture.
The lightning flash with an arrowhead symbol, within an
equilateral triangle is intended to alert the user to the presence
of uninsulated “dangerous voltage” within the product's
enclosure that may be of sufficient magnitude to constitute a
risk of electric shock to persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in
the literature accompanying the appliance.
CAUTION
To reduce the risk of electric shock,
Do not remove cover ( or Back),
No user serviceable parts inside.
Refer servicing to qualified service personnel.
This installation should be make by a qualified service person using
proper installation methods conforming to all local codes.
Contents
Camera Operation
Menu
How to use OSD menu
CAMERA SETUP
CAMERA ID
DNR
MOTION
IRIS
SENS-UP
FLICKERLESS
SHUTTER
DIS
DAY/NIGHT
DIGITAL ZOOM
V-SYNC
DETAIL
AGC COLOR SUP
REVERSE
POSI/NEGA
PIP
WHITE BAL.
OTHER SET
INTELLIGENCE
PRIVACY ZONE
Specification
Troubleshooting
COMMUNICATION
SYSTEM INFO
LANGUAGE
MOTION
MASK AREA
DISPLAY
SENSITIVITY
RESOLUTION
FACTORY DEFAULTS
OSD COLOR
14
14
15
16
16
16
18
19
19
19
19
23
20
21
22
23
23
23
23
23
23
24
24
26
26
26
26
26
27
28
28
28
28
28
30
32
Caution
Features
Warning
2
3
4
Installation
Main Parts
Components
Connection
Drawing
5
6
9
11
12
IR VANDAL CAMERA

1) Do not install the camera in extreme temperature condition.
Only use the camera under conditions where temperatures are between
-10 C and +50 C (if heater have it can operate at : -45 C and +50 C)ºº ºº
Be especially careful to provide ventilation when operating under high temperatures.
2) Do not install or use the camera in a environment where the
humidity is high.
It can cause the image quality to be poor.
3) Do not install or use the camera under unstable lighting conditions.
Severe lighting change or flicker can cause the camera to work improperly.
4) Do not touch the front lens of the camera.
This is one of the most important parts of the camera. Be careful not to leave fingerprints
on the lens cover.
5) Do not drop the camera or protect it from physical shocks.
It can cause malfunctions to occur.
6) Never keep the camera pointed directly at strong light.
It can damage the CCD.
7) Do not expose the camera to radioactivity.
If exposed to radioactivity the CCD will fail.
8) The camera requires periodic inspection.
Contact an authorised technician to carry out the inspection.
9) Stop using your camera when you find it malfunctioning.
If the camera emits smoke or is unusually hot for a long period,
a fire may be caused.
10) Do not Install the camera on a surface that can not support it.
If the camera is installed on an inappropriate surface, it may fall
and cause injury.
11) Do not hold plug with wet hands.
It could cause an electric shock.
12) Do not dis-assemble the camera.
It may result in an electric shock or other hazards.
13) Do not use the camera close to a gas or oil leak.
It may result in a fire or other hazards.
4
3
Ultra High Resolution
By adopting a diagonal 410,000 (PAL) pixel
Sony super high resolution CCD, the camera
produces clear picture quality with a horizontal
resolution of 600 TV lines for color, and 650
TV lines for B/W.
Wide Dynamic Range (WDR)
By adopting a proprietary WDR DSP chip, the
camera delivers clear, high quality pictures
even in backlight, by increasing exposure in
dark areas while decreasing it in bright areas;
a corrected image with clear details results.
Excellent Sensitivity
Adopting a Diagonal 6mm (1/3"), highly
sensitive CCD and digital signal processing
technology, it can clearly distinguish the outline
and color of a subject in an extremely low
luminance environment – even.
DNR (Digital Noise Reduction , 2D+3D)
The DNR technology eliminates noise thus
generating a distinct and clear image.
This camera DNR function utilizes both an
adaptive 2D filter reducing noise in the
brightness of the image and an adaptive 3D
filter reducing noise caused by movement.
True Day & Night
The camera identifies whether it is day or
night and automatically switches to the
appropriate mode, depending on its
environment. By day, the camera switches to
color mode in order to maintain optimal color.
At night, it switches to B/W mode so as to
obtain better picture definition.
DIS (Digital Image Stabilizer)
The DIS function compensates for any camera
movement, to produce more stable pictures.
Sub Monitor Function
The sub monitor function enables easy
adjustment of the camera angle within the
monitoring range during its installation.
RS-485 Communication Built-in
Control Support
Remote OSD menu control via an RS-485
interface is supported.
OSD
The camera control is convenient by using
different foreign language O.S.D. Also the
camera can be controlled by selecting text
displayed on the monitor screen.
Additional Functions
SYNC(INT/LL), SENS-UP, FREEZE,
FLIP(H/V-REV), D-ZOOM, SHARPNESS,
MOTION DETECTION and PRIVACY functions
are provided.
CCVC (Camera Control Via Coaxial cable)
This is a remote control function that overlaps the
coaxial cable with the control signal. In intallation
or repair , this helps you control the communication
controller (optional) without additional cabling.
Features Warning
NOTE:
1) WDR is the main exclusive function for WDR 600TVL
Series Camera.
2) D&N 600TVL has no function. So, OSD MenuWDR
for WDR Camera, may be different with D&N no WDR Camera.

Main Part
Focus Lever
(FAR NEAR)
Zoom Lever
(TELE WIDE)
5) Dual Power Board
4) Base
1) 3 Axis Main Bracket
3) Lens
Front-cover
Flex IR Vandal Dome Series
Shroud
BNC
- Video output
Black Color
- Power input
7) Fan and Heater
> Alarm
> RS485
2) OSD Board
56
1) CameraDome
Components Flex IR Vandal Dome Series
2) Cable for Extra Video
5) Manual
3) Screw for Installation
4) Special L wrench
6) Mounting Template
Flush type Surface type
8) IR LED Board

78
Main Part
1) 3 Axis Main Bracket
Use the 3Axis bracket , it can easy be install to anyplace. Like wall or ceiling.
2) OSD Board
We use the joystick osd board for easily controlled by OSD menu.
}SET : When this switch is pressed for at least
2 seconds, the MAIN MENU appears. This button can be
used to confirm settings after changing the value of the selected
function or current conditions.
}Left / Right and UP / Down :
left and Right : Used when changing item values, by moving
the cursor to the left or right on the menu screen.
Up and Down : Used for selecting items by moving the cursor
up and down on the menu screen.
Extra Video Connector
3) TDN Lens (True Day & Night )
Normal used 2.8~12mm varifocal DC Auto Iris TDN Lens.
4) Base
Smart base for easy install.
5) AC24V/DC12V Dual Power Board
Dual power sported.
12V DC input it is ok. and 24V AC also ok.
OSD Board
Flex IR Vandal Dome Series
6) Inner Shroud
We assemble the inner shroud to the 3 axis bracket, it can
easy be moved with the lens, so lens always at the middle of the inner shroud.
7) Fan and Heater
This is option products, it work under - 0 C .
o
8) IR LED
We have Ø5 36ea high quality IR LEDs.
Main Part
TILT : You can adjust from 0 C to 360 C.°°
You can adjust from 0 C to 90 C.PAN : °°
Drawing (mm)
Flex IR Vandal Dome Series
90 C°
360 C°
355 C°

Installation
Step1. Use the Mounting Template to make the hole on the ceiling, and then fix
the Base Housing to the desired place with screws supplied. After cable and base
connected, before body to the base , please have a check the hole
between body and base, please see
the below picture.
Ceiling
Step 1
Step 2
Step2. Adjusted lens and function by
using the 3 Axis bracket and osd board.
After everything nice, cover the front-cover
to the base by screws that supported.
Flex IR Vandal Dome Series
910
Installation
Flex IR Vandal Dome Series
1. Fix the Base Housing to the desired place with screws supplied.
2. Power Connect & Monitor Impedance.
Made sure which power supply that you selected before you use.
- DC12V regulated power supply (DC12V camera only)
Dual power supply (AC24V/DC12V both can be used)
- To avoid fire or shock hazard, must use a UL listed power supply.
- Set the monitor impedance switch to 75½. Check the impedance switch when
the screen turns blurred.
3. Focus and Functions Adjust
- Open the front cover , and connect the power , and use the extra cable to adjust
the focus and others functions . After finished, please tighten the front cover carefully.
4. Adjust desired scene by turning and moving the camera bracket and fix it with
Stopper Ring by turning it with hands.
5. Put the front-cover over the Base Housing.
6. If you install the flush type camera, please check the below way.
Flush type
Ceiling Ceiling
Ceiling

BNC
- Video output
Black Color
- Power input
> Alarm
> RS485
- As the connecting method varies with the instruments, refer to the manual
supplied with the instrument.
- If necessary, you can connect the monitor to the REMOTE jack on the back of
your camera.
- Only connect the cable when the power is turned off.
- Set the 75Ω / Hi-Z selection switch as shown below if you have an intermediate
device.
VIDEO
1) Connection to Monitor and Power
2) Connection to Power
Connect the adaptor to the power input connector
as shown in the figure right. The Standard voltage
for camera operation : DC 12V ± 10%, AC 24V±10%.
Note
Before connect the power jack , please really have a check the power supply.
Connection
VIDEO
24VAC
Flex IR Vandal Dome Series
11 12
3) Connection to UTP
If you select the UTP camera , you can connect the video signal like below.
When you use the utp camera , please make sure Yellow color jack is video-
output and the black color jack is power input.
Connection
NOTE
Flex IR Vandal Dome Series
1) Yellow color : Video output
2) Black color : Power input
UTP CAT 5/5E
UTP Board
VIDEO VIDEO
Camera
4) Connection to CCVC controller
If you have a CCVC controller, please connect like below, and easy control the
function by the CCVC controller.
Monitor
BNC
- Video output
Black Color
- Power input
> Alarm
> RS485
VIDEO
Hi-Z
75Ω
IN OUT
VIDEO
Hi-Z
75Ω
IN OUT

13
3) Connection to RS-485
Using a RS-485 communication, it will be able to control the OSD menu at the
System Controller or DVR.
(1) The case which it controls from the PC
Using a RS-485 converter, It connects to RS-485 control cable outside camera
and serial cable
EX) SERIAL PORT OF THE PC(COM1) SERIAL CABLE RS-485
→→
CONVERTER RS-485 CONTROL CABLE→
(2)The case which it controls from the DVR or System Controller
It connects the RS-485 control cable in the connection terminal of 485 control
boards which are connected with the DVR or System Controller.
485 Control Board Connection Port RS-485 Control Port
(+) CONNECTION TERMINAL Brown (TRX+)
(- ) CONNECTION TERMINAL Blue (TRX-)
Item
Initial value
Camera ID
1
BAUD RATE
9600
UART MODE
8-NONE-1
RET PKT
ENABLE
çRS-485 Communication establishment initial value
Protocol : SAMSUNG
Baud Rate : 9600bps
Address : 1-255
When using a control system to operate the camera, please use the protocol:-
SAMSUNG, PELCO-P or PELCO-D .
When use RS-485 control , cable isolate the drain wire.-
14
Connection Camera Operation
NOTE
Menu
4) Connection to Alarm
Please see above RS485 connection picture. Normal Alarm output signal open,
and when motion detection operate, alarm output signal low to GND.
NOTE: 1) WDR is the main exclusive function for WDR 600TVL Series Camera.
2) D&N 600TVL has no function. So, OSD Menu for WDR Camera,WDR
may be different with D&N no WDR Camera.
Flex IR Vandal Dome Series
> Alarm
> RS485

16
15
VPS
If you set the VPS (Virtual Progressive Scan)
option, the camera will display the image in
progressive format.

17 18
NOTE: 1) WDR is the main exclusive function for WDR 600TVL Series Camera.
2) D&N 600TVL has no function. So, OSD Menu for WDR Camera,WDR
may be different with D&N no WDR Camera.

19 20
if the function is set , theBACKLIGHT WDR SENS-UP
menu can not be set to .FIX
The of setsBRIGHTNESS DAY NIGHT
the brightness degree of color to BW switching,
for which you can select from , , andLOW MID

2221
HIGH HIGH LOW. As you adjust it from to , the
screen switches to black and white mode under
the darker situation.
DWELL TIME DAY NIGHTOF sets the time to
.maintain switched black and white mode
The OF sets theBRIGHTNESS NIGHT DAY
brightness degree of BW to color switching, for
which you can select from , , and .LOW MID HIGH
As you adjust it from to , the screenHIGH LOW
switches to black and white mode under the
darker situation.
OF sets the time toDWELL TIME NIGHT DAY
maintain switched color mode.

23 24

25 26

27 28
Set the menu to and pressEXTERNAL TRG ON
the switch to display the appropriateSETUP
screen.
EXTERNAL TRG
You can set the to 0~4 seconds.STILL TIME
If is set to FIX, theDELAY TIME DELAY TIME
will be set in sync with the ; ifSTILL TIME
set to , the will be set to yourUSER DELAY TIME
setting.
You can view the system information including
the protocol, address, baud rate, serial number,
camera version, and EEP version
The COMMUNICATION menu is used to configure
the settings regarding UART communications.
Use the connector of the camera to connect the
UART.
Including : SAMSUNG, PELCO-P, PELCO-D,
VICON, PANASONIC, PHILIPS, ERNA,
DIAMOND,VCLTP, KALATEL
Please select a communication protocol.
COMMUNICATION
COMMUNICATION
RS485
PROTOCOL SAMSUNG
9600
1
BAUD RATE
ADDRESS
PROTOCOL
BAUD RATE
ADDRESS : 1-255
Including : 2400, 4800, 9600, 19200, 38400 bps
Baud rate different, depending on theNote:
specified protocol.
The camera supports 5 different languages.
Select a preferred language.
FRANCAIS
DEUTSCH
ESPANOL
ITALIANO
PROTOCOL
ADDRESS
COMM. TYPE
BAUD RATE
SAMSUNG
1
RS485,HALF
9600

29 30
25frame/sec,30frame/sec
lnterlace
60 Hz/NTSC, 50 Hz/PAL
0.00
0.00
0.00
0.00
0.00
0.00
0.2
0.1
0.0007
0.0004
0.4
0.001
NTSC : 768 x 494, PAL : 752 x 582
NTSC 525 Lines / PAL 625 Lines - 2:1 Interlaced
Off/On (x128/NTSC, x160/PAL)
Off/On
6
6
6
(1/50)
3 Floors IR LED Vandal Camera
IR LED ON
NOTE: 1) WDR is the main exclusive function for WDR 600TVL Series Camera.
2) D&N 600TVL has no function. So, OSD Menu for WDR Camera,WDR
may be different with D&N no WDR Camera.
NOTE: 1) WDR is the main exclusive function for WDR 600TVL Series Camera.
2) D&N 600TVL has no function. So, OSD Menu for WDR Camera,WDR
may be different with D&N no WDR Camera.
Double SCAN

31
Max. 820mA (24VAC) /Max.840mA (12VDC)
0.95Kg
149(Ø)×139.6(H)mm
Pan Range
-
Auto Iris [DC]
STD : 2.8~12mm VariFocal Lens/F1.2
TILT Range
0 ~ 90
0~360
STD : RS485 AND DIY Handy Controller
w/BNC-Fe Cable. Option : CCVC Control Key Board
3 Floors IR LED Vandal Camera
NOTE: 1) WDR is the main exclusive function for WDR 600TVL Series Camera.
2) D&N 600TVL has no function. So, OSD Menu for WDR Camera,WDR
may be different with D&N no WDR Camera.
32
If there are problem in operation, please refer to the items below. If the problem
persists, please contact us. Thanks!
Nothing appears on
the screen.
a) Please check the power connection.
b) Please check the video signal line connection.
c) Switch is set to DC (or VIDEO) when using a
VIDEO (or DC) lens.
Problems Troubleshooting
The video image is
not clear.
a) Please check the lens is clean.
b) Please clean the lens with a clean cloth or brush.
c) Please adjust the contrast feature of the monitor.
d) Please make sure that the screen is not exposed
directly to a bright light.
e) Please move the camera if necessary.
f) Please re-adjust the focus of the camera.
The screen is dark.
a) Please adjust the contrast the feature of the monitor.
b) If you have an intermediate device, set the 75/Hi-z
properly, and check the terminals.
c) Please check if an auto iris lens is being used
and adjust the brightness level.
There is a problem with
the camera operation.
The camera surface is
too hot and black stripes
appear on the screen.
Please check if an appropriate power source to
the camera complies with the manufacturer's
standard requirement, or if the voltage keeps
changing.
Troubleshooting

Isn’t DAYNIGHT function setting up the color mode?
Please change it to the EXT mode .
B/W not change?
33
The MOTION
DETECTION function
is not working.
Problems Troubleshooting
a) Please check if 'MOTION DETECTION' mode
is turned on.
b) Please check if the MD LEVEL is too low.
c) Please check the setting of the MD AREA.
Colors are not
quite right. Please check the ' WHITE BAL ' setting.
The screen is
flickering.
a) Please check if the camera is facing directly into
sunlight or fluorescent light.
b) Please check if an auto iris lens is being used.
c) Please check the connection of the lens
connector cable.
L/L mode isnot
able to be selected.
Have you connected your camera to DC power
source? Connect it to AC power source.
L/L mode isnot
available.
Please check the frequency of power supply.
if it 60Hz for NTSC or 50Hz for PAL ?
COLOR mode is
not working.
Please check if the AGC menu is set to the
OFF position.
SENS-UP function is
not working.
a) Please check if the AGC menu is set to the
OFF position.
b) Please check if the SHUTTER menu is set to
MANUAL mode.
Troubleshooting
RS-485
Communication fails.
Check the polarity between RS-485 Control Port
and RS-485 cable.
Check the RS-485 Communication establishment
initial value
RS-485 Communication establishment initial valueö
We recommend that you make ground connect
between camera and controller in order to maintain
safety communication control.
Isn’t DAYNIGHT function setting up the color mode?
Please change it to the EXT mode for ir camera, and
change it to the AUTO mode for w/o ir camera.
485 Control Board Connection Port RS-485 Control Port
(+) CONNECTION TERMINAL (TRX+) 485+
( - ) CONNECTION TERMINAL (TRX-) 485-
Item
Initial value
Camera ID
1
BAUD RATE
9600
UART MODE
8-NONE-1
RET PKT
ENABLE
B/W not change?
Problems Troubleshooting
Troubleshooting
34

This manual suits for next models
2
Table of contents
Other WDR Security Camera manuals