Wearable Life Science ANTELOPE.TECHWEAR User manual

ANTELOPE.TECHWEAR
USER MANUAL

2
Wearable Life Science GmbH
ANTELOPE.TECHWEAR
This user manual forms part of the delivery scope of the ANTELOPE.TECH-
WEAR.
The instruction manual is aimed at the end user. You must be in a position
to read and understand the information contained in this instruction man-
ual and the accompanying documents.
This instruction manual must be kept in a well-known, easily accessible
location at all times, and Wearable Life Science GmbH must be consulted
if any issues or slightest doubts arise.
Wearable Life Science GmbH accept no liability for damage to persons, an-
imals, property or to the product itself which arise from improper use, fail-
ure to observe or inadequate observation of the safety criteria contained
in this user manual, or any alterations to the ANTELOPE.TECHWEAR or the
use of unsuitable replacement parts (non-original parts).
The ANTELOPE.TECHWEAR user manual carefully indicates situations and
risks by means of symbols and safety instructions.
IMPORTANT:
Please always refer to this user manual in order to avoid malfunction and
injury.
There are generally four warning levels, identied by the corresponding
symbols:
CAUTION Indicates a hazard with a low level of risk which, if
not avoided, could result in minor or moderate inju-
ry.
WARNING Indicates a hazard with a medium level of risk which,
if not avoided, could result in serious injury and
equipment damage.
DANGER Indicates a hazard with a high level of risk which, if
not avoided, will result in death or serious injury.
NOTE Indicates information helpful in particular areas or
functions.

3
Wearable Life Science GmbH
CONTACT CUSTOMER CARE
In case you have any further questions or queries regarding your
ANTELOPE.TECHWEAR, please contact our Customer Care Team:
www.antelope.club
+49 (0) 69 795 888 95

4
Wearable Life Science GmbH
TABLE OF CONTENTS
ANTELOPE.TECHWEAR .................................................. 2
CONTACT CUSTOMER CARE.......................................... 3
1. INTRODUCTION ......................................................... 5
2. INTENDED USE ........................................................... 5
3. PURPOSE..................................................................... 5
4. INDICATIONS ............................................................. 6
5. DISCLAIMER ............................................................... 6
6. CONTRAINDICATIONS............................................... 7
7. SCOPE OF SUPPLY...................................................... 8
7.1 ANTELOPE.SHIRT ....................................................... 8
7.2 ANTELOPE.SHORTS ................................................... 8
7.3 ANTELOPE.8C-BOOSTER........................................... 8
7.4 ANTELOPE.TANK-TOP ............................................... 9
7.5 ANTELOPE.CALF-GUARDS......................................... 9
7.6 ANTELOPE.2C-BOOSTER........................................... 9
7.7 ANTELOPE.APP........................................................... 10
7.8 ANTELOPE.SPRAY ...................................................... 10
7.9 BOOSTER Charging Cable......................................... 10
8. INSTRUCTIONS FOR USE ........................................... 11
8.1 Putting on the ANTELOPE.SUIT................................ 11
8.1.1 Connecting the ANTELOPE.SUIT and the
ANTELOPE.8C-BOOSTER...........................................................11
8.2 Putting on the ANTELOPE.TANK-TOP...................... 11
8.2.1 Connecting the ANTELOPE.TANK-TOP and the
ANTELOPE.2C-BOOSTER ...................................... 11
8.3 Putting on the ANTELOPE.CALF-GUARDS............... 12
8.3.1 Connecting the ANTELOPE.CALF-GUARDS and
the ANTELOPE.2C-BOOSTER ................................. 12
8.4 Switching the ANTELOPE.2C-BOOSTER and
ANTELOPE.8C BOOSTER ON/OFF............................ 12
8.5 Connecting the ANTELOPE.2C-BOOSTER and
ANTELOPE.8C-BOOSTER to the ANTELOPE.APP
via Bluetooth ............................................................. 12
8.6 Starting the Stimulation............................................ 13
8.7 Regulating Stimulation.............................................. 13
8.7.1 Ending the Stimulation ......................................... 13
8.8 Using the ANTELOPE.2C-BOOSTER and
ANTELOPE.8C-BOOSTER ........................................... 13
8.8.1 Battery status.......................................................... 14
8.8.2 Charging the BOOSTER.......................................... 14
9. TROUBLE SHOOTING................................................. 15
10. SAFETY INSTRUCTIONS ........................................... 17
11. CARE AND MAINTENANCE...................................... 17
11.1 BOOSTER CARE........................................................ 17
11.2 Washing instructions .............................................. 17
12. DISPOSAL.................................................................. 17
13. GUARANTEE AND WARRANTY................................ 18
14. LABELS ...................................................................... 18
15. TECHNICAL SPECIFICATIONS .................................. 19
15.1 ANTELOPE.8C-BOOSTER......................................... 19
15.2 ANTELOPE.2C-BOOSTER......................................... 19
16. COMPANY INFORMATION ...................................... 19

5
Wearable Life Science GmbH
1. INTRODUCTION
ANTELOPE.TECHWEAR uses Electrical Muscle Stimulation (EMS) for high
intensity training units
A condition of safe use is the responsible handling of ANTELOPE.TECH-
WEAR. In order to reduce risk this user manual must be carefully read
before use of ANTELOPE.TECHWEAR.
SCOPE OF SUPPLY:
• ANTELOPE.SUIT
ANTELOPE.SHIRT
ANTELOPE.SHORTS
• ANTELOPE.8C-BOOSTER
• ANTELOPE.TANK-TOP
• ANTELOPE.CALF-GUARDS
• ANTELOPE.2C-BOOSTER
• BOOSTER Charging Cable
• ANTELOPE.SPRAY
• ANTELOPE.APP
Available to download on iOS and Andriod.
• IOS: https://itunes.apple.com/de/app/antelope-club/
id1139453110?mt=8
• ANDROID: https://play.google.com/store/apps/details?id=club.
antelope.app&hl=en
2. INTENDED USE
The ANTELOPE.TECHWEAR is an Over-The-Counter device intended to
stimulate healthy muscles in order to improve or facilitate muscle perfor-
mance. This product should be used by adults only.
The ANTELOPE.TECHWEAR is not intended for adjunctive therapy in the
treatment of medical diseases and conditions of any kind. None of the
ANTELOPE.TECHWEAR stimulation programs are designed for injured or
disease aicted muscles. Its use on such muscles is contraindicated. The
stimulation imposed on the muscles by the ANTELOPE.TECHWEAR pro-
grams is denitely not suitable for rehabilitation and physiotherapy.
Electrical muscle stimulation may therefore be considered a technique of
muscle training and should only be used for this purpose.
3.PURPOSE
The ANTELOPE.TECHWEAR series stimulates the healthy muscles to im-
prove performance of human body or general well being. It is intended to
be used by healthy adults only.

6
Wearable Life Science GmbH
4. INDICATIONS
The ANTELOPE.TECHWEAR is intended to stimulate healthy muscles in or-
der to improve or facilitate muscle performance. It is to be used by adults
only.
Depending on the parameters of the electrical impulses (pulse frequency,
duration of contraction, duration of rest, total session duration), dierent
types of muscle work can be imposed on the stimulated muscles.
Only use the ANTELOPE.TECHWEAR when you are fully regenerated. Fol-
low our workout instructions and also work out without the ANTELOPE.
TECHWEAR regularly.
5. DISCLAIMER
Before using ANTELOPE.TECHWEAR please consult a physician. The fol-
lowing points should be taken into account. If one or more of the following
apply to you, you must NOT use ANTELOPE.TECHWEAR for safety reasons:
• You have a cardiac pacemaker or other electrical implant(s)
• You are pregnant
• You have a severe neurological, cardiovascular or tumour diseases
• You have a serious disease (i.e. fever, infections, inammations)
• You have muscle ache/soreness
• You have muscle spasms
CAUTION
Do not use the ANTELOPE.TECHWEAR on injured skin or to stimulate the
muscles of an aicted limb or joint.
A possible side-eect of unfamiliar and intensive training is damage to the
muscle tissue. This comes with the partial loss of strength, delayed muscle
soreness and a signicant increase of muscle protein levels (e.g. ceratine
kinase levels) found in the blood. Especially after the rst intense training
sessions with the ANTELOPE.TECHWEAR there is a heightened risk of mus-
cular damage.
Please follow our instructions carefully to avoid some of the problems
mentioned before.

7
Wearable Life Science GmbH
6. CONTRAINDICATIONS
Powered muscle stimulators should not be used on patients with cardiac
demand pacemakers.
1. The long-term eects of chronic electrical stimulation are unknown.
2. Stimulation should not be applied over the neck or mouth. Severe
spasm of the laryngeal and pharyngeal muscles may occur and the
contractions may be strong enough to close the airway or cause dif-
culty in breathing.
3. Stimulation should not be applied across the chest in that the in-
troduction of electrical current into the heart may cause cardiac ar-
rhythmias.
4. Stimulation should not be applied to the head.
5. Stimulation should not be applied over swollen, infected, or in-
amed areas or on skin eruptions.
6. Stimulation should not be applied over, or in proximity to, cancer-
ous lesions.
PRECAUTIONS:
1. Safety of powered muscle stimulators for use during pregnancy has
not been established.
2. Caution should be used for users with suspected or diagnosed heart
problems.
3. Caution should be used for users with suspected or diagnosed epi-
lepsy.
4. Caution should be used in the presence of the following:
a. When there is a tendency to bleed because of injury;
b. Following recent surgical procedures when muscle contrac-
tion may disrupt the healing process;
c. Over the menstruating or pregnant uterus; and
d. Over areas of the skin which lack normal sensation.
5. Some patients may experience skin irritation or hypersensitivity due
to the electrical stimulation or the electrodes.
6. Electrode placement and stimulation settings should be followed in
accordance with this manual.
7. Powered muscle stimulators should be kept out of the reach of chil-
dren.
8. Powered muscle stimulators should be used only with the leads and
electrodes recommended for use by the manufacturer.
9. Powered muscle stimulators should not be used while driving, oper-
ating machinery, or during any activity in which involuntary muscle
contractions may put the user at undue risk of injury.
ADVERSE REACTIONS
Skin irritation and burns beneath the electrodes have been reported with
the use of powered muscle stimulators.
The following points may indicate serious damage to the muscle tissue
(rhabdomyolysis). If you nd yourself displaying one of these symptoms
please contact a physician:
• Brown urine
• Myalgia (severe muscular pain)
• Extreme swelling of the muscle

8
Wearable Life Science GmbH
7. SCOPE OF SUPPLY
7.1 ANTELOPE.SHIRT
The fabric of the ANTELOPE.SHIRT consists of 54% polyamide, 36% poly-
propylene and 10% elastane. The ANTELOPE.SHIRT includes ten silicone
electrodes integrated into the compression fabric. A baseplate with mag-
netic buttons attached to the shirt enables the textile to be connected with
the ANTELOPE.8C-BOOSTER.
The ANTELOPE.SHIRT is only intended for training the neck, upper arm,
chest, abdomen and back. In combination with the ANTELOPE.SHORTS,
the ANTELOPE.SHIRT comprises the ANTELOPE.SUIT.
NOTE
The shirt can be connected individually to the ANTELOPE.8C-BOOSTER. A
muscle stimulating training without the ANTELOPE.SHORTS is possible.
7.2 ANTELOPE.SHORTS
The fabric of the ANTELOPE.SHORTS consists of 54% polyamide, 36% poly-
propylene and 10% elastane. The ANTELOPE.SHORTS includes six silicone
electrodes integrated into the compression fabric. A connection cable with
magnetic buttons hangs from the ANTELOPE.SHORTS to enables the tex-
tile to be connected with the ANTELOPE.8C-BOOSTER.
The ANTELOPE.SHORTS are only intended for training the hamstrings and
gluteal muscles. In combination with the ANTELOPE.SHIRT, the ANTELOPE.
SHORTS comprise the ANTELOPE.SUIT.
NOTE
The ANTELOPE.SHORTS cannot be used directly without the shirt. If you
only want to use the functions of the shorts, please put on the complete
ANTELOPE.SUIT and choose the relevant muscle parts in the ANTELOPE.
APP.
7.3 ANTELOPE.8C-BOOSTER
The ANTELOPE.8C-BOOSTER is the energy source of the ANTELOPE.SUIT.
The 8C-BOOSTER is equipped with a rechargeable lithium-ion battery.
The stimulation intensity is adjustable by pressing the [+/-] button on the
BOOSTER.
• By pressing [+] you increase the intensity of all channels by one unit
• By pressing [-] you decrease the intensity of all channels by one unit
The ANTELOPE.2C-BOOSTER should be charged using the Booster
Charging Cable and a standard USB-Charger. The ANTELOPE.8C-BOOSTER
is intended only to power and regulate the electrical stimulation for the
ANTELOPE.SUIT.

9
Wearable Life Science GmbH
7.4 ANTELOPE.TANK-TOP
The fabric of the ANTELOPE.TANK-TOP consists of 54% polyamide, 36%
polypropylene and 10% elastane.
The ANTELOPE.TANK-TOP includes four silicone electrodes integrated into
the compression fabric. Magnetic buttons attached to the ANTELOPE.SUIT
enables the textile to be connected with the ANTELOPE.2C-BOOSTER with
external cables.
The ANTELOPE.TANK-TOP is only intended for training the abdomen and
back.
7.5 ANTELOPE.CALF-GUARDS
The fabric of the ANTELOPE.CALF-GUARDS consists of 54% polyamide,
36% polypropylene and 10% elastane.
The ANTELOPE.CALF-GUARDS include two silicone electrodes integrat-
ed into the compression fabric. Magnetic buttons attached to the ANTE-
LOPE.CALF-GUARDS enables the textile to be connected with the ANTE-
LOPE.2C-BOOSTER with external cables
The ANTELOPE.CALF-GUARDS are only intended for training the calves.
7.6 ANTELOPE.2C-BOOSTER
The ANTELOPE.2C-BOOSTER is the energy source of the ANTELOPE.
TANK-TOP and ANTELOPE-CALF-GUARDS. The ANTELOPE.2C-BOOSTER is
equipped with a rechargeable lithium-ion battery.
The stimulation intensity is adjustable by pressing the [+/-] button on the
BOOSTER.
• By pressing [+] you increase the intensity of all channels by one unit
• By pressing [-] you decrease the intensity of all channels by one unit
The ANTELOPE.2C-BOOSTER should be charged using the Booster
Charging Cable and a standard USB-Charger.
The ANTELOPE.2C-BOOSTER is intended only to power and regulate the
electrical stimulation for the ANTELOPE.TANK-TOP and ANTELOPE.CALF-
GUARDS.

10
Wearable Life Science GmbH
7.7 ANTELOPE.APP
The ANTELOPE.APP acts as an alternative external control system to regu-
late the stimulation of ANTELOPE.TECHWEAR.
Without connecting the ANTELOPE.APP with the ANTELOPE.BOOSTER it is
not possible to begin electrical stimulation.
The following stimulation programs are available via the ANTELOPE.APP:
Endurance Strength Massage
Frequency 40 Hz 60-100 Hz 60 Hz
Impulse Wide 400 µs 350 µs 200 µs
Impulse Typ Contrast 4-second interval 2,5 seconds stimulation 1
second ramp
7.8 ANTELOPE.SPRAY
The ANTELOPE.SPRAY is a medically certied liquid that is purposed to
improve the consistency of electrical stimulation.
7.9 BOOSTER Charging Cable
The BOOSTER Charging Cable is a micro USB cable which connects to the
ANTELOPE.8C-and ANTELOPE.2C-BOOSTER for the purpose of charging

11
Wearable Life Science GmbH
8. INSTRUCTIONS FOR USE
NOTE
We recommend the use of ANTELOPE TECHWEAR in 20 minute sessions
twice per week. Between training sessions, sucient time for regenera-
tion should be allowed. Before, during and after your training you should
drink enough water.
8.1 Putting on the ANTELOPE.SUIT
1. Open the three zippers of the ANTELOPE.SHIRT - one on each side
and one in the middle.
2. Put on the shirt and make sure that the electrodes lie at on your
skin without folds or wrinkles.
3. Close the zippers.
4. Put on the ANTELOPE.SHORTS
NOTE
The electrodes must be placed directly onto the skin. Excessive hair growth
or extremely dry skin can aect the stimulation. Ensure that the electrodes
are placed directly on the targeted muscle.
8.1.1 CONNECTING THE ANTELOPE.SUIT AND THE ANTELOPE.8C-BOOSTER
DANGER
DO NOT CONNECT THE ANTELOPE.SUIT WITH ANTELOPE.8C-BOOSTER IF
THE BOOSTER IS TURNED ON.
1. On the back of the BOOSTER there is a grid of buttons. Hanging
from your ANTELOPE.SHORTS there is a connector with buttons. To
connect the two, place the shorts connector on the lower-most but-
tons of the BOOSTER.
2. On the side of your ANTELOPE.SHIRT there is another grid of but-
tons – this is the baseplate. To connect your shirt to the BOOSTER,
place the BOOSTER on the baseplate.
8.2 Putting on the ANTELOPE.TANK-TOP
1. Open the zippers on front and on each side of the TANK-TOP
2. Put on the TANK-TOP and make sure that the electrodes lie at on
your skin without folds or wrinkles.
3. Close the zippers.
8.2.1 Connecting the ANTELOPE.TANK-TOP and the ANTE-
LOPE.2C-BOOSTER
DANGER
DO NOT CONNECT THE ANTELOPE.TANK-TOP WITH ANTELOPE.2C-BOOST-
ER IF THE BOOSTER IS TURNED ON.
1. Connect the magnetic button ending of the external cables to the
magnetic buttons on the textile. One cable pair should connect to
the front buttons of the textile and the other pair to the back.
2. Connect the jack plugs of the external cables to the jack plug input
at the bottom of the 2C-BOOSTER.
NOTE
Be sure to observe which channel (I or II) the external cables are connect-
ed to.

12
Wearable Life Science GmbH
8.3 Putting on the ANTELOPE.CALF-GUARDS
1. Open the zipper on each CALF-GUARD.
2. Put on the CALF-GUARDS and make sure that the electrodes lie at
on your skin without folds or wrinkles.
3. Close the zippers.
8.3.1 Connecting the ANTELOPE.CALF-GUARDS and the ANTE-
LOPE.2C-BOOSTER
DANGER
V DO NOT CONNECT THE ANTELOPE.CALF-GUARDS WITH ANTE-
LOPE.2C-BOOSTER IF THE BOOSTER IS TURNED ON.
1. Connect the magnetic button ending of the external cable to the
magnetic buttons on the textile. Only one cable pair should be used
to connect both CALF-GUARDS.
2. Connect the jack plugs of the external cables to the jack plug input
at the bottom of the 2C-BOOSTER.
NOTE
Be sure to observe which channel (I or II) the external cables are connect-
ed to.
8.4 Switching the ANTELOPE.2C-BOOSTER and ANTELOPE.8C BOOST-
ER ON/OFF
• On: Press and hold the [+]-button for three seconds.
• O: Press and hold the [-]-button for three seconds.
8.5 Connecting the ANTELOPE.2C-BOOSTER and
ANTELOPE.8C-BOOSTER to the ANTELOPE.APP via Bluetooth
NOTE
The ANTELOPE.APP must rst be downloaded via the App Store or Google
Play Store before connecting.
1. Hold the [+] button on the BOOSTER until the blue shining LED be-
gins to ash. This indicates the BOOSTER is searching for a compat-
ible device via Bluetooth.
2. Switch the Bluetooth ON from your compatible device
3. Open the ANTELOPE.APP on your device and select the “connect”
tab. Your Booster appears on this page. Tap on the Booster to con-
nect and select the options in the elds to continue.
NOTE
• After switching on the BOOSTER and before connecting to a Blue-
tooth device, the BOOSTER will display a constant green LED.
• After connecting to the APP via Bluetooth, the LED will change to a
constant blue light.
DANGER
If the connection to a Bluetooth device is interrupted for several minutes,
the BOOSTER DOES NOT switch o automatically. If a connection between
a Bluetooth device and the BOOSTER is interrupted, immediately discon-
nect the connection between BOOSTER and Baseplate. (see 8.7.1)

13
Wearable Life Science GmbH
8.6 Starting the Stimulation
NOTE
Stimulation can only be started from the ANTELOPE.APP. App and BOOST-
ER must be connected before.
1. Tap the EMS tab of the ANTELOPE.APP and select a program.
NOTE The duration of each program can be adjusted.
2. Tap the “start” button at the bottom of the screen to begin stimula-
tion.
8.7 Regulating Stimulation
• Once the stimulation has been started it can be regulated using the
ANTELOPE.APP and/or directly from the ANTELOPE.BOOSTER.
• Pressing the [+] on the EMS tab of the ANTELOPE.APP OR on the
BOOSTER, will increase the intensity by one unit on all channels.
• Pressing the [-] on the EMS tab of the ANTELOPE.APP OR on the
BOOSTER, will reduce the intensity by one unit on all channels.
DANGER
If stimulation cannot be felt at an intensity of 25%, SWITCH OFF the BOOST-
ER and APPLY ANTELOPE. SPRAY directly to the electrodes in the textile.
Then restart the ANTELOPE.APP and make sure that all intensity levels are
set to 0. Once this process is completed, restart using your ANTELOPE.
TECHWEAR according to the instructions in this manual. (see 8.1).
NOTE
Tapping the muscle groups on the EMS tab of ANTELOPE.APP will enable
individual regulation of specic muscle groups.
8.7.1 Ending the Stimulation
Stimulation can be ended by:
• Pressing the [-] button on the BOOSTER for 3 Seconds.
• Pressing “pause” on the ANTELOPE.APP.
OR
DANGER
• Directly detaching the BOOSTER from the Baseplate or External Ca-
bles by pulling with force.
8.8 Using the ANTELOPE.2C-BOOSTER and ANTELOPE.8C-BOOSTER
NOTE
Please fully charge the ANTELOPE.8C-BOOSTER before initial use.

14
Wearable Life Science GmbH
8.8.1 Battery status
• Whilst charging the BOOSTER will display a ashing green LED.
• Once you disconnect the BOOSTER from the charger, the LED will
switch o.
• Once the remaining charge drops under 20%, the BOOSTER will dis-
play a red LED.
8.8.2 Charging the BOOSTER
The BOOSTER takes approximately one hour to fully charge and it pro-
vides approximately 6 sessions.
To avoid damage to your equipment please check the following require-
ments before charging the BOOSTER:
• Your charging plug is compatible with your country’s power socket.
• The nominal voltage in your electrical network ts the requirements
of the charging device you are using.

15
Wearable Life Science GmbH
9. TROUBLE SHOOTING
Problem POSSIBLE CAUSE SOLUTION
Unpleasant feel-
ing from Stimu-
lation
Skin condition is dry
• Spray the ANTELOPE.SPRAY directly on the electrodes.
• Drink enough water before, during and after training.
• If necessary, start your training with a light warm-up without stimulation.
DANGER If stimulation cannot be felt at an intensity of 25%, SWITCH OFF the BOOSTER and APPLY ANTELOPE. SPRAY directly to the
electrodes in the textile. Then restart the ANTELOPE.APP and make sure that all intensity levels are set to 0. Once this process is completed,
restart using your ANTELOPE.TECHWEAR according to the instructions in this manual. (see 8.1).
Stimulation intensity is
too high
• Reduce stimulation intensity
• Stop stimulation
Defect electrode Please contact our Customer Care-Team.
Stimulation is
weak / Cannot
feel Stimulation
Skin Condition is dry
Apply ANTELOPE.SPRAY directly onto the electrodes in the textile.
DANGER If stimulation cannot be felt at an intensity of 25%, SWITCH OFF the BOOSTER and APPLY ANTELOPE. SPRAY directly to the
electrodes in the textile. Then restart the ANTELOPE.APP and make sure that all intensity levels are set to 0. Once this process is completed,
restart using your ANTELOPE.TECHWEAR according to the instructions in this manual. (see 8.1).
Stimulation Intensity is
too low
Gradually increase stimulation intensity.
DANGER If stimulation cannot be felt at an intensity of 25%, SWITCH OFF the BOOSTER and APPLY ANTELOPE. SPRAY directly to the
electrodes in the textile. Then restart the ANTELOPE.APP and make sure that all intensity levels are set to 0. Once this process is completed,
restart using your ANTELOPE.TECHWEAR according to the instructions in this manual. (see 8.1).
Defect electrode Please contact our Customer Care-Team.

16
Wearable Life Science GmbH
BOOSTER will not
connect to ANTE-
LOPE.APP
GPS is not activated on
your Android device Activate GPS on your Android device.
Bluetooth connection
was not established via
ANTELOPE.APP
Always establish Bluetooth connection within the ANTELOPE.APP, not via the Bluetooth search on your device.
Bluetooth compatibility
issues
• Close or reinstall the app in task manager.
• Log in.
• Start the search for your BOOSTER.
• Turn on the BOOSTER.
• Tap once on the displayed BOOSTER.
• If a connection is still not possible, clear the Bluetooth cache and restart the search.
The stimulation
is too strong
in some areas
and too weak in
others
Stimulation of all mus-
cle groups has been
increased at once
Deselect the muscle groups from the ANTELOPE.APP and adjust accordingly.
Skin Condition varies GEFAHR ] SWITCH OFF the BOOSTER and APPLY ANTELOPE. SPRAY directly to the electrodes in the textile. Then restart the ANTELOPE.
APP and make sure that all intensity levels are set to 0. Once this process is completed, restart using your ANTELOPE.TECHWEAR according to
the instructions in this manual. (see 8.1).
Defect electrode Please contact our Customer Care-Team.

17
Wearable Life Science GmbH
10. SAFETY INSTRUCTIONS
Please follow the safety instructions. Doing otherwise may cause damage
to the device, expiry of your guarantee and injury.
• Store the ANTELOPE.TECHWEAR out of the reach of children in or-
der to prevent them from swallowing parts of the product.
• You must not try to replace the battery pack yourself. Opening the
BOOSTER yourself may cause damage and will lead to expiry of your
guarantee and warranty.
• Do not touch the electrodes with your ngers while operating your
device.
• Do not use the ANTELOPE.TECHWEAR while driving, operating ma-
chines or manual labour.
• Do not use the ANTELOPE.TECHWEAR in wet conditions such as
heavy rain or snow, while bathing, showering or swimming.
• Never put the BOOSTER or the cables into the washing machine.
The textile including the electrodes is washable by hand.
• Start at low intensities and slowly increase the power. Do not devi-
ate from the instructions given in this manual.
• While working out actively with the ANTELOPE.TECHWEAR always
keep your muscles tense or keep moving.
11. CARE AND MAINTENANCE
11.1 BOOSTER CARE
• Store your BOOSTER in a cool, dry place.
• Charge your BOOSTER at least every six months.
11.2 Washing instructions
The textile consists of 54% polyamide, 36% polypropylene and 10% elas-
tane. It is hand-washable WITHOUT the BOOSTER. To ensure maximum
durability of the ANTELOPE.TECHWEAR please follow the instructions:
• The textile is washable per hand (max. 30°C ).
• Do not tumble-dry. Hang damp garment from line or bar, in or out
doors.
NOTE
Textile colour may bleed during washing.
12. DISPOSAL
Products with an ANTELOPE logo must not be disposed of with your
household waste. Please dispose it in compliance with statutory regula-
tions. The equipment cannot be discarded with household refuse. The
equipment must be delivered to a suitable collection point for disposal. By
doing so, you will be contributing to the safeguarding of natural resources
and health.

18
Wearable Life Science GmbH
13. GUARANTEE AND WARRANTY
We assure a 24-month warranty on all our ANTELOPE products according
to statutory provisions.
We oer a guarantee on electrodes of six months or 1300 minutes. (De-
pending on the facts)
We also oer a guarantee on the ANTELOPE.2C-BOOSTER and ANTE-
LOPE.8C-BOOSTER of six-month or 2000 minutes. (Depending on the facts)
Should your ANTELOPE product develop a fault within the warranty peri-
od, Wearable Life Science will undertake to repair or replace the product
or any parts found to be defective with no charge for labor or materials,
provided the product:
• Has been used for its intended purpose and in the manner de-
scribed in this user manual.
• The ANTELOPE.BOOSTER was only charged with the supplied
BOOSTER Charging Cable and a standard USB charger.
• Has not been subjected to misuse or neglect.
• Has not been modied or repaired by anyone other than an ap-
proved ANTELOPE agent.
Please contact our Customer Care- Team in case you have any questions
regarding your guarantee.
14. LABELS
The following labels are printed on the package or the user manual (colour
and size may vary):
By displaying the CE mark the
manufacturer conrms that
the product complies with all
necessary requirements of
the EU regulations. Confor-
mity assessment procedures
have been completed.
Manufacturer Details
Serial Number
Critical information (as per
the user manual)
Do not use if the package is
damaged
Important instruction inside
This device must be sepa-
rated from household waste
and recycled as electronic
waste
Wash by hand
Do not iron
Do not tumble dry
Do not dry clean
Do not bleach
Handle with care
Do not wring
Temperature limits to which
the medical device can be
safely exposed
Class II device with internal
power supply

19
Wearable Life Science GmbH
15. TECHNICAL SPECIFICATIONS
15.1 ANTELOPE.8C-BOOSTER
Parameter Description
Model ANTELOPE.8C-BOOSTER
Storage Conditions Temperature (0-35°C),
Humidity (20 – 85%)
Operating Conditions Temperature (0-40°C),
Humidity (20 – 65%)
Measurements 14,2cm x 8,5cm x 2,6cm
Weight 220g
Current max. 80mA
Frequency 1-2000 HZ (depending on the program)
Impulse Width 50 µs - 500µs
The serial number of the BOOSTER can be found on the device.
15.2 ANTELOPE.2C-BOOSTER
Parameter Beschreibung
Model ANTELOPE.2C-BOOSTER
Storage Conditions Temperature (0-35°C),
Humidity (20 – 85%)
Operating Conditions Temperature (0-40°C),
Humidity (20 – 65%)
Measurements 10,3cm x 4,9cm x 1,9cm
Weight 80g
Current max. 100mA
Frequency 1-5000 HZ (depending on the program)
Impulse Width 50 µs - 400µs
The serial number of the BOOSTER can be found on the device.
16. COMPANY INFORMATION
Wearable Life Science GmbH
Niddastraße 64
D - 60329 Frankfurt am Main
Managing Directors: Dr. Maria Deeg-Neuhaus, Antonio Gatti Balsarri
Commercial Register: local court Frankfurt am Main, HRB 112098
VAT-ID: DE295000570
Contact:
Phone.: +49 (0) 69 79588-895
E-Mail: [email protected]
Website: www.antelope.club
Table of contents