Welotec EG500 Series User manual

Welotec GmbH
Zum Hagenbach 7
2
Table of Contents
1Copyright ....................................................................................................................................................... 3
2Regulatory Compliances.............................................................................................................................. 3
2.1 CE Notice ............................................................................................................................................... 3
3Safety Instructions ....................................................................................................................................... 4
4Radio frequencies (only relevant for EG503L) .......................................................................................... 5
4.1 Radio frequencies 4G LTE Europe ........................................................................................................ 5
4.2 Radio frequencies 3G UMTS Europe..................................................................................................... 5
5Product Specifications................................................................................................................................. 6
6Power Supply ................................................................................................................................................ 6
7Dimensions .................................................................................................................................................... 7
7.1 Product Drawings ................................................................................................................................. 7
8Interfaces and Connections......................................................................................................................... 8
9Power Consuption ........................................................................................................................................ 9

Welotec GmbH
Zum Hagenbach 7
3
1Copyright
Copyright and Trademarks, 2017 Publishing. All Rights Reserved
This manual, software and firmware described in it are copyrighted by their respective owners and
protected under the laws of the Universal Copyright Convention. You may not reproduce, transmit,
transcribe, store in a retrieval system, or translate into any language, in any form or by any means,
electronic, mechanical, magnetic, optical, chemical, biological, molecular, manual, or otherwise, any part
of this publication without the express written permission of the publisher.
All products and trade names described within are mentioned for identification purpose only. No affiliation
with or endorsement of the manufacturer is made or implied. Product names and brands appearing in this
manual are registered trademarks of their respective companies. The information published herein has
been checked for accuracy as of publishing time. No representation or warranties regarding the fitness of
this document for any use are made or implied by the publisher.
We reserve the right to revise this document or make changes in the specifications of the product described
therein at any time without notice and without obligation to notify any person of such revision or change.
2Regulatory Compliances
2.1 CE Notice
This device complies with the requirements of the CE directive.

Welotec GmbH
Zum Hagenbach 7
4
3Safety Instructions
Please read these instructions carefully and keep these instructions for future references.
1. Disconnect this equipment from Power outlet before cleaning. Do not use liquid or sprayed detergent for
cleaning. Use moisture sheet or cloth for cleaning.
2. Keep this equipment from humidity.
3. Make sure power cord in laid in such a way that people cannot step on it. Do not place anything over the
power cord.
4. All cautions and warning on the equipment should be noted.
5. If the equipment is not used for a long time, disconnect the equipment from main power to avoid being
damaged by transient over voltage.
6. Prolonged usage with less than 9V may damage the PSU or destroy the Mainboard
7. Never pour any liquid into opening as this could cause fire or electrical shock.
8. If one of the following situations arises, have the equipment checked by service personnel.
a. The power cord or plug is damaged.
b. Liquid has penetrated the equipment.
c. The equipment has been exposed to moisture in a condensation Environment.
d. The equipment does not work well, or it is unable to get it working on following this user manual.
e. The equipment has dropped and damaged.
9. Do not leave this equipment in an environment unconditioned, storage temperature below -
20 degrees or above 60 degrees in Celsius for longer periods of time, it may damage the equipment.
10. Unplug the power cord when doing any service or adding optional kits.
11. Lithium Battery Caution:
a. Danger or explosion can happen if the battery is incorrectly replaced. Replace only the original or
equivalent type recommended by the manufacturer. Dispose used batteries according to the
manufacturer’s instructions.
b. Do not remove the cover and ensure no user serviceable components are present inside. Take the
unit to the service Center for service and repair.

Welotec GmbH
Zum Hagenbach 7
5
4Radio frequencies (only relevant for EG503L Models)
4.1 Radio frequencies 4G LTE Europe
Frequency Frequency range and transmission power
Band 1(FDD)
•Frequency range Down: 2110 MHz – 2170 MHz
•Frequency range Up: 1920 MHz – 1980 MHz
•Max. transmission power: 199 mW
Band 3 (FDD)
•Frequency range Down: 1805 MHz – 1880 MHz
•Frequency range Up: 1710 MHz – 1785 MHz
•Max. transmission power: 199 mW
Band 7 (FDD)
•Frequency range Down: 2620 MHz – 2690 MHz
•Frequency range Up: 2500 MHz – 2570 MHz
•Max. transmission power: 199 mW
Band 8 (FDD)
•Frequency range Down: 925 MHz – 960 MHz
•Frequency range Up: 880 MHz – 915 MHz
•Max. transmission power: 199 mW
Band 20 (FDD)
•Frequency range Down: 791 MHz – 821 MHz
•Frequency range Up: 832 MHz – 862 MHz
•Max. transmission power: 199 mW
Band 28 (FDD)
•Frequency range Down: 758 MHz – 803 MHz
•Frequency range Up: 703 MHz – 748 MHz
•Max. transmission power: 199 mW
Band 38 (TDD)
•Frequency range Down: 2570 MHz – 2620 MHz
•Frequency range Up: 2570 MHz – 2620 MHz
•Max. transmission power: 199
Band 41 (TDD)
•Frequency range Down: 2496 MHz – 2690 MHz
•Frequency range Up: 2496 MHz – 2690 MHz
•Max. transmission power: 199
4.2 Radio frequencies 3G UMTS Europe
Frequency Frequency range and transmission power
Band 1 (WCDMA)
•Frequency range Down: 2110 MHz – 2170 MHz
•Frequency range Up: 1920 MHz – 1980 MHz
•Max. transmission power: 251 mW
Band 8 (WCDMA)
•
Frequency range Down: 925 MHz – 960 MHz
•Frequency range Up: 880 MHz – 915 MHz
•Max. transmission power: 251 mW

Welotec GmbH
Zum Hagenbach 7
6
5Product Specifications
Technical Details
EG503 (4GB RAM)
EG503 (Standard)
General
Information
Type
Edge Gateway
Series EG500
Hardware
CPU
Intel® Atom™ x5-E3940 /
Intel® Atom™ x7-E3950
Intel® Atom™ x5-E3940
RAM
4 GB
8 GB
Free storage for
container and
data
45 GB
TPM
TPM 2.0 with TrEE 1.1
Gigabit Ethernet
3x RJ45
USB 3.0
1
4
Serial
-
1x RS-232 or 1x RS-485
Power Supply
Input voltage
12 to 24 V DC
Connector
Terminal block
Physical
characteristic
Housing material
Steel / Aluminum
Ingress protection
IP20
Dimensions
(W x H x D)
110x 90x 30 mm
Weight
500 g
Mounting
DIN- Rail
Environmental
Conditions
Operation
temperature range
-20 - +60 °C
Humidity
5 – 95 % (non-condensing)
6Power Supply
Use the terminal block to connect the Edge Gateway to 12…24V DC
Pin Description
Pin 0 – GND (left) Ground
Pin 1 – VCC V+ 12-24
Pin 2 – GND Ground
Pin 3 – PSW (right) External power switch

Welotec GmbH
Zum Hagenbach 7
9
9Power Consumption
Results are for reference only!
Voltage
Power off
Start up
max.
Start up
stable
EG503W
Burn in max
EG503L
Burn in max
Shut down
12V
0.14A
0.95A
0.62A
1.10A
1.50A
0.82A
24V
0.09A
0.50A
0.32A
0.57A
0.77A
0.42A
The Power consumption depends on options and software.