Wen 3410 Use and care manual

Air Filtration System
Model: 3410
Questions? Problems?
Please call our customer help line:
(800) 232-1195 M-F 8-5 CST or
by email:
Operation and Safety Instructions

Air Filtration System Model: 3410 WENPRODUCTS.COM
2
Table of Contents
Technical data ………………………………………………………………… 2
General safety rules …………………………………………………………… 3
Specific safety rules for air filters …………………………………………….. 5
Electrical information …………………………………………………………. 6
Know your air filtration system………………………………………………… 7
Assembly and adjustments ……………………………………………………. 8
Operation ……………………………………………………………………… 9
Maintenance …………………………………………………………………… 10
Exploded view and parts list …………………………………………………... 12
Warranty ………………………………………………………………………. 14
Technical data
Air Filtration System Model: 3410
Motor: 120 V, 60 Hz, 1A, 1/6HP
Air Flow Speeds: 300, 350, and 400 cfm
Filters: 1 micron inner/ 5 microns outer
Noise: 50-60 dB
Maximum remote control distance: 26'
Net weight: 31 lb
Part #
Description
90243-026
Inner Filter
90243-027
Outer Filter

Air Filtration System Model: 3410 WENPRODUCTS.COM
3
General safety rules
Safety is a combination of common sense, staying alert and knowing how the air filter works.
SAVE THESE SAFETY INSTRUCTIONS.
WARNING: To avoid mistakes that could cause serious injury, do not plug in the saw
until the following steps have been read and understood.
1. READ and become familiar with this entire instruction manual. LEARN the tool’s applications,
limitations, and possible hazards.
2. AVOID DANGEROUS CONDITIONS. Do not use power tools in wet or damp areas or expose
them to rain. Keep work areas well-lit.
3. DO NOT use power tools in the presence of flammable liquids or gases.
4. ALWAYS keep your work area clean, uncluttered, and well-lit. DO NOT work on floor
surfaces that are slippery.
5. KEEP BYSTANDERS AT A SAFE DISTANCE from the work area, especially when the tool
is operating. NEVER allow children or pets near the tool.
6. DO NOT FORCE THE TOOL to do a job for which it was not designed.
7. DRESS FOR SAFETY. Do not wear loose clothing, gloves, neckties, or jewelry (rings, watches,
etc.) when operating the tool. Inappropriate clothing and items can get caught in moving parts
and draw you in. ALWAYS wear non-slip footwear and tie back long hair.
8. ALWAYS remove the power cord plug from the electrical outlet when making adjustments,
changing parts, cleaning, or working on the tool.
9. KEEP GUARDS IN PLACE AND IN WORKING ORDER.
10. AVOID ACCIDENTAL START-UPS. Make sure the power switch is in the OFF position
before plugging in the power cord.
11. NEVER LEAVE A RUNNING TOOL UNATTENDED. Turn the power switch to OFF. Do
not leave the tool until it has come to a complete stop.
12. NEVER STAND ON A TOOL. Serious injury could result if the tool tips or is accidentally hit.
DO NOT store anything above or near the tool.
13. MAINTAIN TOOLS PROPERLY. ALWAYS keep tools clean and in good working order.
Follow instructions for lubricating and changing accessories.

Air Filtration System Model: 3410 WENPRODUCTS.COM
4
General safety rules (continued)
14. DO NOT operate the tool if you are under the influence of drugs, alcohol, or medication that
could affect your ability to use the tool properly.
15. USE SAFETY GOGGLES AT ALL TIMES—that comply with ANSI Z87.1. Normal safety
glasses only have impact resistant lenses and are not designed for safety. Wear a face or dust
mask when working in a dusty environment. Use ear protection, such as plugs or muffs, during
extended periods of operation.

Air Filtration System Model: 3410 WENPRODUCTS.COM
5
Specific safety rules for air filters
1. To reduce the risk of injury, unplug the air filter from the power source before changing
filters or servicing.
2. If mounting the air filter to the ceiling:
a. Make sure the bottom of the air filter is at least 7' above the floor.
b. Make sure the air filter is anchored to a building structure that is capable of
supporting a minimum of 100 lbs.
c. Do not mount the air filter to non-structural elements such as dry wall, false ceiling
panels, etc.
3. Position the air filter so that it is at least 3' from a corner and from any heating or cooling
vents.
4. Do not use the air filter in environments that have volatile fumes or smoke. This air filter is
designed and intended for the filtration of air borne wood dust only.
5. Do not expose the air filter to water or rain. Do not use in damp environments.
6. Do not duct a power tool or machine directly into the air filter.

Air Filtration System Model: 3410 WENPRODUCTS.COM
6
Electrical information
Grounding Instructions
IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides the path of
least resistance for electric current and reduces the risk of electric shock. This tool is equipped with
an electric cord that has an equipment grounding conductor and a grounding plug. The plug MUST
be plugged into a matching outlet that is properly installed and grounded in accordance with ALL
local codes and ordinances.
DO NOT MODIFY THE PLUG PROVIDED. If it will not fit the outlet, have the proper outlet
installed by an electrician.
IMPROPER CONNECTION of the equipment grounding conductor can result in electric shock.
The conductor with the green insulation (with or without yellow stripes) is the equipment
grounding conductor. If repair or replacement of the electric cord or plug is necessary, DO NOT
connect the equipment grounding conductor to a live terminal.
CHECK with a licensed electrician or service personnel if you do not completely understand the
grounding instructions, or if you are not sure if the tool is properly grounded.
USE ONLY THREE-WIRE EXTENSION CORDS that have 3-pronged plugs and outlets that
accept the tool's plug as shown in Fig. A. Repair or replace a damaged or worn cord immediately.
CAUTION: In all cases, make certain the outlet in question is properly grounded. If you are not
sure if it is, have a licensed electrician check the outlet.
WARNING: This unit is for indoor use only. Do not expose to rain or use in damp
location.

Air Filtration System Model: 3410 WENPRODUCTS.COM
7
Know your air filtration system
A
Carrying handle
F
Outer filter
B
Control panel/receiver
G
Hangers and locknuts (4)
C
Fuse
H
Wood screw hooks (4)
D
Power cord
I
Chains (4)
E
Filter lock clip
J
Remote control
Not shown:
1-Inner filter (Assembled on the machine)
2-AA batteries
Unpacking
Carefully unpack the air filter and all its parts. Do not discard the carton or any packaging until the
air filter is completely assembled.

Air Filtration System Model: 3410 WENPRODUCTS.COM
8
Assembly and adjustments
The air filter is designed to circulate air and filter wood and other non-metallic dust. The unit
requires only minimal assembly. However, it is important to consider how and where to place the
unit. When selecting a site, make sure there is a suitable power source nearby. Do not use extension
cords with the air filter.
Hanger placement (Fig. 1)
1. Thread the locknuts (1) almost all the way up the hanger (2).
2. Thread a hanger into each of the four mounting holes (3) on the top of the air filter cabinet.
3. Tighten each locknut against the cabinet top. Hold the hangers so that they do not spin
while tightening the locknut.
Ceiling placement (Fig.1 and 2)
Make sure the unit will be situated at least 7' above the floor and at least 3' (1 m) away from a
corner and from any heating or air vents.
1. Install the wood screw hooks (4) into the building support structure. Do not mount the air filter to
non-structural surfaces such as dry wall or false ceiling grids.
The hooks are rated for this air filter, and can support a minimum of 100 lbs.
2. Place a chain (6) on each wood screw hook (4).
3. Attach the hangers (2) on each chain (6).
4. Make sure the unit is level horizontally, and is at least 7' above the floor. If it is not, remove the
air filter and adjust the length of the chain as needed. Then remount the unit.
5. Plug the air filter power cord directly into a power source.

Air Filtration System Model: 3410 WENPRODUCTS.COM
9
Operation
The air filter can be operated directly using the control panel or with the remote control.
Turn on the air filter and speed setting (Fig. 3 and 4)
1. Plug the power cord into an appropriate power source.
2. Press the ON/Speed button (1) on the control panel or the remote control to power on the air
filter. The air filter will be running at low speed. The LO LED will light, indicating that the
unit has been worked at low speed.
3. Press the ON/Speed button (1) again to change the speed. The LEDs (2) next to the
ON/speed button on the control panel indicate the selected speed-high, medium, or low.
Set the timer (Fig. 3 and 4)
A timer allows you to operate the filter set the length of time (1, 2, 4 hours and clear the timer) that
the air filter will operate before shutting off automatically. The air filter can be set the timer with
the remote control only.
1. Press the TIME button (5) on the remote control to start the timer. The cycle is 1 hour, 2
hours, 4 hours and clear the timer.
2. Press the TIME button (5) on the remote control to set the timer. The LEDs (4) on the
control panel indicate the amount of time selected.
Note: the unit will shut off automatically after the selected time interval elapses. When you choose
clear the timer, the air filter will keep running until turning it off.
Turn off the air filter
To turn off the air filter, press the OFF button on the control or on the remote control.

Air Filtration System Model: 3410 WENPRODUCTS.COM
10
Maintenance
WARNING: To reduce the risk of injury, unplug the air filter from the power source
before changing the filters or servicing the air filter.
Change the filters (Fig. 5 and 6)
Check the inner and outer filters periodically, depending on the amount of use, and change the
filters when needed. Clogged filters will reduce the amount of air circulating through the filter.
1. Lift up the clips (1) and remove the outer filter (2) from the cabinet housing.
2. Pull the inner filter (3) out of the cabinet.
3. Install a new inner filter.
4. Install a new outer filter. The arrow on the outside of the filter indicates the proper direction
to insert the filter into the cabinet.
Check and replace the fuse (Fig. 7)
1. Turn the fuse cap (1) counterclockwise to loosen and pull the fuse away from the control panel.
2. Insert a new fuse (2amps) (2) in the fuse cap and put it into the control panel.

Air Filtration System Model: 3410 WENPRODUCTS.COM
11
Maintenance (continued)
Replace the batteries in the remote control
1. Open the battery compartment on the remote control.
2. Remove the old batteries.
3. Install 2 new "AA" batteries according to the picture shown in the battery compartment.

Air Filtration System Model: 3410 WENPRODUCTS.COM
12
Exploded view and parts list

Air Filtration System Model: 3410 WENPRODUCTS.COM
13
Exploded view and parts list (continued)
Item#
Part #
Description
Qty
Item#
Part #
Description
Qty
1
90243-001
Hex Nut 4
13
39
90243-039
Fuse Holder
1
2
90243-002
Flat Washer 4
13
40
90243-040
Fuse Cap
1
3
90243-003
Lock Washer 4
13
41
90243-041
Fuse (2A)
1
4
90243-004
Screw M4X12
5
42
90243-042
Control Panel Label
1
5
90243-005
Screw M6X16
6
43
90243-043
Screw M3X15
1
6
90243-006
Air Box Front Cover
1
44
90243-044
Screw M3X30
1
7
90243-007
Grid Plate
1
45
90243-045
Screw ST3.2X8
1
8
90243-008
Air Guide
1
46
90243-046
Printed Circuit Board
1
9
90243-009
Hex Nut 6
6
47
90243-047
Switch Box
1
10
90243-010
Flat Washer 6
6
48
90243-048
Flat Washer 3
2
11
90243-011
Lock Washer 6
6
49
90243-049
Lock Washer 3
2
12
90243-012
Screw M4X12
8
50
90243-050
Hex Nut 3
2
13
90243-013
Screw ST4X10
34
51
90243-051
Wire
1
14
90243-014
Air Box
1
As02
90243-AS02
Motor & Fan Assembly
1
15
90243-015
Screw M6X12
4
52
90243-052
Fan Wheel
1
16
90243-016
Carrying Handle
1
53
90243-053
Fan Housing Cover
1
17
90243-017
Handle Bracket
1
54
90243-054
Fan Housing
1
18
90243-018
Screw M5X16
2
55
90243-055
Rubber Spacer
4
19
90243-019
Flat Washer 5
3
56
90243-056
Large Washer 5
4
20
90243-020
Lock Washer 5
3
57
90243-057
Lock Nut 5
4
21
90243-021
Hex Nut 5
6
58
90243-058
Motor
1
22
90243-022
Screw M5X12
1
59
90243-059
Capacitor Cover
1
23
90243-023
Lock Washer 5
2
60
90243-060
Capacitor
1
24
90243-024
Wire
1
61
90243-061
Fan Housing Cover
1
25
90243-025
Grid Plate
1
62
90243-062
Screw M5X25
4
26
90243-026
Inner Filter
1
63
90243-063
Hanger
4
27
90243-027
Outer Filter
1
64
90243-064
Flange Nut 6
4
28
90243-028
Rubber Foot
4
65
90243-065
Chain
4
29
90243-029
Remote Control Unit
1
69
90243-069
Switch Box Cover
1
As01
90243-AS01
Control Panel Assembly
1
72
90243-072
Wood Screw Hook
4
36
90243-036
Power Cord
1
37
90243-037
Strain Relief
1
38
90243-038
Screw M5X20
1

Air Filtration System Model: 3410 WENPRODUCTS.COM
14
Warranty
WEN®AIR FILTRATION SYSTEM WARRANTY
WEN Products is committed to build tools that are dependable for years. Our warranties are consistent with this commitment and our
dedication to quality.
LIMITED WARRANTY OF WEN CONSUMER POWER TOOLS PRODUCTS FOR HOME USE
GREAT LAKES TECHNOLOGIES, LLC ("Seller") warrants to the original purchaser only, that all WEN consumer power tools
will be free from defects in material or workmanship for a period of two (2) years from date of purchase. Ninety days for all WEN
products, if the tool is used for professional use.
SELLER'S SOLE OBLIGATION AND YOUR EXCLUSIVE REMEDY under this Limited Warranty and, to the extent permitted
by law, any warranty or condition implied by law, shall be the repair or replacement of parts, without charge, which are defective in
material or workmanship and which have not been misused, carelessly handled, or misrepaired by persons other than Seller or
Authorized Service Center. To make a claim under this Limited Warranty, you must make sure to keep a copy of your proof of
purchase that clearly defines the Date of Purchase (month and year) and the Place of Purchase. Place of purchase must be a direct
vendor of Great Lakes Technologies, LLC. Third party vendors such as garage sales, pawn shops, resale shops, or any other
secondhand merchant void the warranty included with this product. Contact[email protected] or 1-800-232-1195 to
make arrangements for repairs and transportation.
When returning a product for warranty service, the shipping charges must be prepaid by the purchaser. The product must be shipped
in its original container (or an equivalent), properly packed to withstand the hazards of shipment. The product must be fully insured
with a copy of the warranty card and/or the proof of purchase enclosed. There must also be a description of the problem in order to
help our repairs department diagnose and fix the issue. Repairs will be made and the product will be returned and shipped back to the
purchaser at no charge.
THIS LIMITED WARRANTY DOES NOT APPLY TO ACCESSORY ITEMS THAT WEAR OUT FROM REGULAR USAGE
OVER TIME INCLUDING BELTS, BRUSHES, BLADES, ETC.
ANY IMPLIED WARRANTIES SHALL BE LIMITED IN DURATION TO ONE (1) YEAR FROM DATE OF PURCHASE.
SOME STATES IN THE U.S., SOME CANADIAN PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN
IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.IN NO EVENT SHALL
SELLER BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING BUT NOT LIMITED TO
LIABILITY FOR LOSS OF PROFITS) ARISING FROM THE SALE OR USE OF THIS PRODUCT. SOME STATES IN THE
U.S. AND SOME CANADIAN PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS
WHICH VARY FROM STATE TO STATE IN THE U.S., PROVINCE TO PROVINCE IN CANADA AND FROM COUNTRY
TO COUNTRY.
THIS LIMITED WARRANTY APPLIES ONLY TO PORTABLE ELECTRIC TOOLS, BENCH POWER TOOLS, OUTDOOR
POWER EQUIPMENT AND PNUMATIC TOOLS SOLD WITHIN THE UNITED STATES OF AMERICA, CANADA AND
THE COMMONWEALTH OF PUERTO RICO. FOR WARRANTY COVERAGE WITHIN OTHER COUNTRIES, CONTACT
THE WEN CUSTOMER SUPPORT.
SAVE YOUR RECEIPTS. THIS WARRANTY IS VOID WITHOUT THEM.
Other manuals for 3410
2
Table of contents
Popular Fan manuals by other brands

LEGRAND
LEGRAND MIDDLE ATLANTIC UQFP Series instruction sheet

Home Decorators Collection
Home Decorators Collection BELFORD Use and care guide

NuTone
NuTone 765hl instruction manual

Progress Lighting
Progress Lighting AirPro Midvale P250011 installation manual

cecotec
cecotec 05912 instruction manual

Stavoklima
Stavoklima AXI2 Series user manual