Whale INSTANT MATCH SDS236T Assembly instructions

WITH
Quick Connect Guide
SDS236T
Instant Match Transformer


Important Information
Please read the following information before setting up a Bluetooth®wireless technology connection
between the Whale Instant Match®transformer and Mira®Advance Flex Extra (J09N) shower:
• The electrical wiring must conform to EU wiring regulations BS7671:2008 Part 7 (17th Edition).
• The Bluetooth®function of the Whale Instant Match®transformer will only work with the Mira®
Advance Flex Extra (J09N) shower.
• Previous Whale Instant Match®Wireless transformers cannot be connected wirelessly to the Bluetooth®
wireless technology enabled Mira Advance Flex Extra Shower (J09N).
• Bluetooth® wireless technology enabled transformers can be easily identified by the blue test button.
• For optimum signal strength, mount the transformer within 5 metres of the shower within the same room.
• ocating the transformer outside of a 5 meter radius or in a different room can cause a communication
breakdown between the transformer and shower, resulting in intermittent or complete failure to operate.
• The Bluetooth connection is only to be used where the transformer is installed in the bathroom with
the shower. Where the transformer is installed in a boxing only plastic access panels are to be used.
• A hardwired connection must be established if a Bluetooth® wireless technology connection cannot be
made between the shower and transformer.
• If any component or cord is damaged, it must be replaced by a qualified person to avoid a hazard.
WARNING
Plumbing of the Waste Pipe
Bluetooth®wireless technology
A wireless Bluetooth connection may be used to allow the
SDS236T (755.678) Whale Instant Match®transformer to
communicate with the Mira Advance Flex Extra (J09N)
shower without the use of a physical hardwired connection
or external flow sensor to activate the pump. To set up
the wireless connection, please follow the process below.
2

Set Up
1. Shower and Transformer settings
• Before starting the Bluetooth® pairing process, please ensure that the "B E Pump Enable" or
"Pump K2" switch inside the front cover of the Mira®Advance Flex Extra (J09N) has been set
to the "ON" position, and that the “Wired Pump Mode” or "Pump K1" and "Reserved 2" or
"Pump K3" switches remain in the "OFF" position as per the diagram shown.
• At this stage, please ensure that your transformer is set to position 7 for “Bluetooth”
and the pipe inlet diameter must be set to 1 for 15mm.
BEAB
43 DEG C
45 DEG C
RESERVED
6L/MIN
PUMP LK3
PUMP LK2
PUMP LK1
Whale
Transformer
Settings
Blue Jumper - Sensor Position 7
Grey Jumper - Over run 10 Seconds
Red Jumper - Pipe inlet 15mm
1234
56
78
BEAB CARE MODE
OFF ON
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE
OR
3

4
• Turn on power to the shower using the pull cord.
• This will automatically pair the shower and pump.
3. Configuring the shower
2. Transformer set up
• Switch the mains electric supply to the transformer
ON and wait to hear the audible beep from the transformer.
The light on the transformer will now flash red to indicate
that a Bluetooth®connection has not yet been established.
• Press and HO D the blue test button on the transformer
until the light flashes red and green to indicate that the
transformer is now in pairing mode.
NOTE: You now have 120 seconds to pair the transformer
to the shower.
Plumbing of the Waste Pipe
Easy Pairing for Mira Advance Flex Extra J09
Manufactured after Week 2 2019 ie 02/19 on
production date label located on base of shower.
Skip to Page 7

• Ensure that the electric supply to the shower is turned OFF.
Then turn the dial on the shower to FULL COLD.
3. Shower set up
2. Transformer set up
• Switch the mains electric supply to the transformer
ON and wait to hear the audible beep from the transformer.
The light on the transformer will now flash red to indicate
that a Bluetooth®connection has not yet been established.
• Press and HO D the blue test button on the transformer
until the light flashes red and green to indicate that the
transformer is now in pairing mode.
NOTE: You now have 120 seconds to pair the transformer
to the shower.
• Switch the mains electric supply to the shower ON,
Start/Stop button will illuminate.
• Within 10 seconds press and HO D the Start/Stop
button on the shower until the Start/Stop light on
the black button goes off.
4. Configuring the shower
lumbing of the Waste Pipe
Pairing setup for Mira Advance Flex Extra
J09 Manufactured prior to Week 2 2019
5

6
6. Pairing the shower to the Whale
Instant Match®transformer
• Press and release the start/stop button on the shower.
The status light on the shower will now flash blue to
indicate that the shower is in pairing mode.
• The status light on the shower will then flash white and you
will hear an audible beep from the shower to indicate that the
transformer has successfully been paired to the shower.
• The Whale®transformer will flash green only to indicate
that it is paired to the Mira®shower.
• Turn the temperature control to full cold and press the
Start/Stop button on the shower. The shower will now
return to normal standby mode.
• You may now follow the “Post Installation Procedure” in
the Mira®Advance Flex Extra (J09N) Instruction Manual
(page 25) if necessary.
7. Completing the pairing
5. Slowly turn the dial on
the shower to position 2

Service work that may need to be carried out on the Mira®Advance Flex Extra (J09N) shower
e.g. the renewal of the control PCB board may require the Bluetooth® wireless technology
connection between the shower and Whale Instant Match®transformer to be terminated
and paired again. To unpair the transformer from the shower, please follow these steps.
1. Switch the mains electric
supply to the shower OFF
2. Be sure to leave the mains electric
supply to the pump O . The light on
the transformer will flash blue
lumbing of the Waste Pipe
Bluetooth® wireless technology unpairing
3. Press and HOLD the test button
on the transformer until the light
flashes red. The transformer and
shower have now been unpaired
NOTE: To pair the shower to the transformer
again, please follow the Bluetooth® wireless
technology set up procedure.
7

8
In cases where the Mira shower needs to be paired to a new transformer or re-paired
with an existing transformer, the following steps to unpair the shower must be taken.
1234
56
78
BEAB CARE MODE
OFF ON
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE
Plumbing of the Waste Pipe
Bluetooth wireless technology unpairing
Mira Advance Flex Extra (J09 )
1234
56
78
BEAB CARE MODE
OFF ON
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE
• Isolate power from Mira shower
• Remove front cover from Mira shower
• Move DIP switch ‘B E PUMP ENAB E’
to ‘OFF’ position (see opposite)
1. Unpair transformer and shower
• Replace front cover
• Turn power on to Mira shower
2. Power cycle shower
• Isolate power from Mira shower
• Remove front cover from Mira shower
• Move DIP switch ‘B E PUMP ENAB E’ to ‘ON’ position
(see opposite)
• Replace front cover
• The shower is ready to be paired with Whale transformer
3. Pair transformer and shower

9
From Transformer
TERMINAL BLOCK
N L
Brown
CN13
Black
Red
Plumbing of the Waste Pipe
Whale Instant Match®Transformer
Hardwired Connections
Mira®Advance Flex Extra 1.1785.005 (J09 )
Wired Connections to the Whale Instant Match®Transformer
Whale Transformer Settings
Blue Jumper - Sensor Position 6
Grey Jumper - Over run 10 Seconds
Red Jumper - Pipe inlet 15mm
Connection to Mira®Advance Flex Extra J09N Shower
Ensure all LK settings are set to
‘OFF’ for hardwired connection
Flex Extra J09N
Where a Bluetooth®connection cannot be established between the transformer and shower,
a hardwired connection may be used (on compatible showers) to activate the pump.
The hardwired connection allows the transformer and shower to communicate by means
of a physical wired connection, eliminating the need for an external flow sensor.
Compatible showers and their pump connections may be found below.
1234
56
78
BEAB CARE MODE
OFF ON
43 DEG C
45 DEG C
RESERVED 1
ECO
RESERVED 2
BLE PUMP ENABLE
WIRED PUMP MODE

Whale®Transformer Settings
Blue Jumper - Sensor Position 4
Grey Jumper - Over run 10 Seconds
Red Jumper - Pipe inlet 15mm
Triton®Safeguard +
Omnicare Design,
Omnicare Style, T150Z+
Wired Connections to
the Whale Instant
Match®Transformer
Redring®Selectronic WP
(SEL85WP or SEL95WP)
Wired Connections to the Whale
Instant Match®Transformer
Blue Jumper - Sensor Position 4
Grey Jumper - Over run 10 Seconds
Red Jumper - Pipe inlet 15mm
Redring Shower
Connections
and Settings
Plumbing of the Waste Pipe
Whale Instant Match®Transformer
Hardwired Connections Cont'd
Triton®Shower Connections and Settings
Redring®Shower Connections and Settings
Whale®Transformer Settings
10

Whale®Transformer Settings
Blue Jumper - Sensor Position 5
Grey Jumper - Over run 10 Seconds
Red Jumper - Pipe inlet 15mm
Venturi®sensor
Please ensure that water flow
through the sensor is in the
direction of the arrow on the sensor.
11
Whale®Transformer Settings
Blue Jumper - Sensor Position 2
Grey Jumper - Over run 10 Seconds
Red Jumper - Pipe inlet 15mm
Whale®Transformer Settings
Blue Jumper - Sensor Position 4
Grey Jumper - Over run 10 Seconds
Red Jumper - Pipe inlet 15mm
Sika®Sensor
Gems®Sensor
Please ensure that water flow
through the sensor is in the
direction of the arrow on the sensor.
Please ensure that water flow
through the sensor is in the
direction of the arrow on the sensor.
umbing of the Waste Pipe
Whale Instant Match®Transformer
Flow Sensor Connections
There are two versions of Gems®flow sensor:
1000 pulses per litre (ppl) and 2200 ppl.
Blue jumper position 3 = 1000 ppl
Blue jumper position 4 = 2200 ppl (shown below)
An external flow sensor should be used where a shower is not compatible with
a Bluetooth® wireless technology or hardwired connection to activate the pump.
Compatible flow sensors and their connections to the transformer are listed below.
Sika®Sensor Connection
Gems®Sensor Connection
When connecting to the Grundfos®Venturi sensor it is important to connect an earth wire
from the Venturi sensor to the signal earth connection on Whale®transformer (shown below).
Grundfos®(Venturi) Connection

12
Whale®Transformer Settings
Flow Switch
Step 1: Turn Dip switch 2 to the 'ON' position.
Step 2: Move red jumper to pipe size '1' for 15mm inlet pipe.
Step 3: Move the blue jumper to increase or decrease the pump
speed as required, using the table below as a guide.
Step 4: Move the grey jumper to increase or decrease the pump
overrun if necessary.
Whale Instant Match®Transformer
Flow Switch Connections
In a situation where a Bluetooth®wireless technology or
hardwired connection with the shower cannot be established,
or a suitable flow sensor has not been fitted, the Whale
SDS236T Instant Match transformer can be used with an
AK1568 flow switch to activate the pump.
Electric Shower Settings
Jumper Flow Rate
Position ( PM)
1. 4.5 - As shown opposite
2. 5.0
3. 5.5
4. 6.0
5. 6.5
6. 7.0
7. 7.5
• Flow rates are nominal values only.
This will vary depending on pipework.
Dip Switches
Please ensure that water flow
through the sensor is in the direction
of the arrow on the sensor.

Whale Instant Match®Transformer
Flow Switch Connections Cont'd
Blue Jumper - Sensor Position 1
Grey Jumper - Over run 10 seconds
Red jumper - Pipe inlet 15mm
Whale®Transformer Settings
Blue Jumper - Sensor Position 1
Grey Jumper - Over run 30 Seconds
Red Jumper - Pipe inlet 22mm
Note: An additional flow switch is available in the
AK1570 Mixer Valve Conversion kit (sold separately).
Step 1: Turn Dip switch 2 to the 'ON' position.
Step 2: Move red jumper to pipe size '2' for 22mm inlet pipe.
Step 3: Move the blue jumper to increase or decrease the pump
speed as required, using the below table as a guide.
Step 4: Move the grey jumper to increase or decrease the pump
overrun if necessary. 30 is the recommended setting for
use on mixer showers.
Mixer Shower Settings
Flow Switch x 2
Jumper Flow Rate
Position ( PM)
1. 7.5 - As shown opposite
2. 8.0
3. 8.5
4. 9.0
5. 9.5
6. 10.0
7. 11.0
• Flow rates are nominal values only.
This will vary depending on pipework.
Dip Switches
Please ensure that water flow
through the sensor is in the direction
of the arrow on the sensor.
13

©Copyright Whale 2019 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE® and WHALE
IN TANT MATCH® are registered trademarks of Munster imms Engineering Limited, Bangor, Northern Ireland trading as Whale.
Whale’s policy is one of continuous improvement and we reserve the right to change specications without prior notice. Illustrations are
for guidance purposes only. Neither the accuracy nor completeness of the information contained in this or any product literature is
guaanteed by the Company and may be subject to change at its sole discretion.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth IG, Inc. and any use of such marks by Munster
imms Engineering Ltd (trading as Whale) is under licence. Other trademarks and trade names are those of their respective owners.
MIRA® is a registered trade mark of Kohler Mira Limited.
TRITON® is a registered trade mark of Triton howers a division of Norcros Group (Holdings).
REDRING® is a registered trade mark of Redring Xpelair Group Limited.
IKA® is a registered trade mark of Dr. iebert & Kuhn GMbH & Co. KG
GEM ® is a registered trademark of Gems ensors & Controls.
GRUNDFO ® is a registered trademark owned by Grundfos Management A/ or Grundfos A/ , Denmark.
14

0345 9090 912
drainagesupport@whalepumps.com
www.whalepumps.com
@Whalecare
Whale, 2 Enterprise Road,
Bangor, Co. Down,
BT19 7TA, N.Ireland
Ref. 182.606_v4_1019
Other manuals for INSTANT MATCH SDS236T
1
Table of contents
Other Whale Transformer manuals