manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Whirlpool
  6. •
  7. Air Conditioner
  8. •
  9. Whirlpool 1163570 User manual

Whirlpool 1163570 User manual

Other Whirlpool Air Conditioner manuals

Whirlpool ACH082 User manual

Whirlpool

Whirlpool ACH082 User manual

Whirlpool SPIW309A3WF.1 User manual

Whirlpool

Whirlpool SPIW309A3WF.1 User manual

Whirlpool ACE244PT3 User manual

Whirlpool

Whirlpool ACE244PT3 User manual

Whirlpool ACM082PS7 User manual

Whirlpool

Whirlpool ACM082PS7 User manual

Whirlpool AR1230XA0 User manual

Whirlpool

Whirlpool AR1230XA0 User manual

Whirlpool ACQ088PV User manual

Whirlpool

Whirlpool ACQ088PV User manual

Whirlpool ACPE102PS2 User manual

Whirlpool

Whirlpool ACPE102PS2 User manual

Whirlpool ACS052XH1 User manual

Whirlpool

Whirlpool ACS052XH1 User manual

Whirlpool AR1800XA0 Operation manual

Whirlpool

Whirlpool AR1800XA0 Operation manual

Whirlpool ATE0743SPP Quick start guide

Whirlpool

Whirlpool ATE0743SPP Quick start guide

Whirlpool ACM184XA0 User manual

Whirlpool

Whirlpool ACM184XA0 User manual

Whirlpool 881406658997 Assembly instructions

Whirlpool

Whirlpool 881406658997 Assembly instructions

Whirlpool WHAW050CW User manual

Whirlpool

Whirlpool WHAW050CW User manual

Whirlpool CA10WXP0 User manual

Whirlpool

Whirlpool CA10WXP0 User manual

Whirlpool 1188910 Assembly instructions

Whirlpool

Whirlpool 1188910 Assembly instructions

Whirlpool TA07002F0 User manual

Whirlpool

Whirlpool TA07002F0 User manual

Whirlpool ACQ142 User manual

Whirlpool

Whirlpool ACQ142 User manual

Whirlpool WHAP081AW User manual

Whirlpool

Whirlpool WHAP081AW User manual

Whirlpool WHHW182AW User manual

Whirlpool

Whirlpool WHHW182AW User manual

Whirlpool YACQ082XK1 User manual

Whirlpool

Whirlpool YACQ082XK1 User manual

Whirlpool ACC108PS Assembly instructions

Whirlpool

Whirlpool ACC108PS Assembly instructions

Whirlpool R511 User manual

Whirlpool

Whirlpool R511 User manual

Whirlpool SLIM RANGE R22 User manual

Whirlpool

Whirlpool SLIM RANGE R22 User manual

Whirlpool SPOW 407 User manual

Whirlpool

Whirlpool SPOW 407 User manual

Popular Air Conditioner manuals by other brands

Fujitsu ASYG 09 LLCA installation manual

Fujitsu

Fujitsu ASYG 09 LLCA installation manual

York HVHC 07-12DS Installation & owner's manual

York

York HVHC 07-12DS Installation & owner's manual

Carrier Fan Coil 42B Installation, operation and maintenance manual

Carrier

Carrier Fan Coil 42B Installation, operation and maintenance manual

intensity IDUFCI60KC-3 installation manual

intensity

intensity IDUFCI60KC-3 installation manual

Frigidaire FAC064K7A2 Factory parts catalog

Frigidaire

Frigidaire FAC064K7A2 Factory parts catalog

Sanyo KS2432 instruction manual

Sanyo

Sanyo KS2432 instruction manual

LG MultiV Series installation manual

LG

LG MultiV Series installation manual

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

CLIMAVENETA

CLIMAVENETA a-CHD U-2T 606+2209 OPERATING AND INSTALLATION Manual

Midea EWK06CW5 user manual

Midea

Midea EWK06CW5 user manual

Pioneer FAB Series installation manual

Pioneer

Pioneer FAB Series installation manual

SPT WA-1511S user manual

SPT

SPT WA-1511S user manual

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric

Mitsubishi Electric Mr.Slim MSZ-A24NA operating instructions

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Mitsubishi Electric

Mitsubishi Electric PUHZ-RP50VHA4 Service manual

Panasonic CS-S18HKQ Service manual

Panasonic

Panasonic CS-S18HKQ Service manual

Panasonic CS-E15NKE3 operating instructions

Panasonic

Panasonic CS-E15NKE3 operating instructions

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Friedrich ZoneAire Compact P08SA owner's manual

Friedrich

Friedrich ZoneAire Compact P08SA owner's manual

Daikin R32 Split Series installation manual

Daikin

Daikin R32 Split Series installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Part No. 1163570 Rev. A
IMPORTANT:
Read and save
these instructions.
IMPORTANT:
Installer: Leave Installation Instructions
with the homeowner.
Homeowner: Keep Installation Instructions
for future reference.
Save Installation Instructions for local
electrical inspector’s use.
Air Conditioner
Proper installation is your responsibility. supply cord is required
Make sure you have everything See Electrical requirements.
necessary for correct installation. It is
the customer’s responsibility to comply
Important: Observe all
with the installation specifications
governing codes and
ordinances.
provided.
9
re
/Electrical outlet
must be available
within the reach of
\ the P~~~;~s~PP~Y
opening si2
Check location where air
conditioner will be installed:
l
Correct opening size,
l
Adequate wall support for
weight of air conditioner,
l
An electrical outlet within
Do Not use an
extension cord.
l
Free movement of air to
rooms to be cooled.
The opening dimensions must
have 24-7/8” width and a
15-l/4” height.
reach of power supply cord,
Electrical Shock Hazard
It is the customer’s responsibility: Electrical Code, ANSI/NFPA
l
To contact a qualified 704atest edition”, and all
electrical installer. local codes and ordinances.
. To assure that the electrical
installation is adequate and in Failure to do so could result in
conformance with National fire, electrical shock or other
personal injury.
Personal Injury/Product Damage Hazard
l
Because of the weight and size falling out of opening during
of the air conditioner, more installation.
than one person is needed to
l
Do Not locate air conditioner
move, lift and safely install it. where cabinet front is
l
Handle air conditioner with exposed to a heat source
care. Metal fins on front and that raises the surface
rear coils are sharp. temperature above 12O’F.
. Do Not drink the water that
collects inside the air Failure to follow these
conditioner. It is not sanitary. instructions could result in
l
Maintain a firm hold on the air personal injury or damage to
conditioner to prevent it from air conditioner.
Copies of the standards listed may be obtained from:
‘National Fire Protecllon Association
Balierymarch Park
Quincy. Massachusetts 02269
Page 2
Tools
and
materials needed
for installation:
%
Parts supplied for
installation:
-
2 screws
- gasket
-drain hose connector
Mounting Kit, Part No. 1158268 from
authorized parts distributor.
Electrical
requirements
Electrical Shock Hazard
0Electrical ground is required on
this appliance.
elf cold water pipe is interrupted by
plastic, non-metallic gaskets or
other insulating materials, Do Not
use for grounding.
*Do Not ground to a gas pipe.
*Do Not modify the power supply
cord plug. If it does not fit the
outlet, have a proper outlet
installed by a qualified electrician.
*Do Not have a fuse in the neutral
or grounding circuit. A fuse in the
neutral or grounding circuit could
result in electrical shock.
*Do Not use an extension cord with
this appliance.
*Check with a qualified electrician
if you are in doubt as to whether
the appliance is properly
grounded.
Failure to follow these instructions
could result in serious injury or
death.
If codes permit and a separate
grounding wire is used, it is
recommended that a qualified
electrician determine that the
grounding path is adequate.
A single-phase, 60-Hz, AC-only,
electrical supply is required on a
separate circuit. A 15amp time-
delay fuse or circuit breaker is
required Copper wire (#14
gauge) is required. The fuse size
must not exceed the circuit rating
specified on the model and serial
label. The model and serial label is
located behind the front panel on
the base flange.
Specific electrical requirements
are listed in the chart. Follow the
requirements for the type of plug
on the power supply cord.
W&g
requirements
Plug Type A Plug Type B
;$f%g
P
Lb
W”blade
receotacls
0
‘J
3-pron
fJou”cf”g-
ype wall
receptacle.
grouncllng
prow
power supply cord groundlng prong
115volt - 230/208-volt -
103% min., 197.6~ min.,
126.5~ max.
253~
max.
7.5-amp 12-amp rating
rating or less or less - use a
- a double single outlet
outlet is and a sep-
acceptable. orate circuit.
7.6- through 12- through 16-
12-amp ratings amp ratings -
- use only a use only a
jingle outlet single outlet
and separate and a sep-
Zircuit. orate circuit.
Exordmended grounding
For your personal safety, this
appliance must be grounded.
This appliance is equipped with a
power supply cord having a
3-prong grounding plug. To
minimize possible shock hazard,
the cord must be plugged into a
mating, 3-prong grounding-type
wall receptacle, grounded in
accordance with the National
Electrical Code, ANSVNFPA 70 -
latest edition*, and all local codes
and ordinances. If a mating wall
receptacle is not available, it is the
personal responsibility and
obligation of the customer to have
a properly grounded, 3-prong wall
receptacle installed by a qualified
electrician.
Now start...
With air conditioner in room where
it will be installed.
I
THROUGH-THE-WALL
INSTALLATION INSTRUCTIONS.
It is the customer’s responsibility
and obligation to have this
product installed by a qualified
technician familiar with through-
the-wall room air conditioner
installations.
appropriate header
if required \
Pl
ss
Frame
Construction
appropriate header
if required,
lintel
I
alternate
construction
for plaster
-
’
Brick Veneer to frame.
Construction
1
When using a wood,
n
metal or plastic molding,
the finish frame should line up with
inside wall. If the plastered wall is
to be flush with the cabinet and
no molding is used, the finish
frame must be set l/2 inch into
the wall.
hi
wall opening
w
t
24-718”
2,
-I
Dimension
Cut opening
depends on wall
through the wall.
thickness and
Remove insulation.
type of molding.
3
Use 1-inch or heavier
lumber for wood frame.
n
Measure depth of wall
opening and frame. Apply wood
preservative to the outside
exposed surface.
4
Insert the frame in the wall
opening. Square and level
n
frame. Nail frame securely
to the wall studs.
5
Remove air conditioner and
n
front panel from carton.
6
If you plan to install a drain
hose to the back of the air
1 condiiioner, install the drain
hose connector as follows:
1, Remove the drain hose
connector, gasket and screws
from the plastic bag.
2. Attach them on the back of the
air conditioner as shown above.
Note: If you are installing a new
unit into an existing sleeve, you
may need to modify the sleeve for
the drain connector.
Page 3
Personal Injury/Product
Damage Hazard
Maintain a firm hold on the air
conditioner to prevent it from
falling out of the opening during
installation.
Failure to follow this instruction
could result in personal injury or
damage to the air conditioner.
7
If Through-the-Wall Sleeve
n
No. AOW22WZ has been
purchased, go to Step 90.
mounting brackets air conditioner
frame
If Through-the-Wall Mounting Kit
No. 1158268 will be used, attach
mounting brackets from Kit No.
1158268 as shown. Place air
conditioner in center of opening.
Property Damage
Check that air conditioner
cabinet is tilted to the outside so
that water will run to the outside.
Failure to do so may cause
damage to property.
8
Place level
n
on air con-
ditioner. There
should be a tilt to
the outside of
about one bubble
The air conditioner
should be level from side to side.
mounting brackets air conditioner
frame
9
Secure air conditioner in
n
opening by attaching the
mounting brackets to the frame
with wood screws. Go to Step 10.
9a.
Through-the-wall
sleeve installation:
Check the air conditioner model
number on the model/serial label
located behind the front panel on
the base flange. Check the air
conditioner cabinet model
number on the model/serial rating
label located in the lower right
front corner of the cabinet.
If air conditioner model number
starts with letters ACU, remove the
rear grille from the air conditioner
and discard the grille.
9b
Install the
n
AOW22WZ sleeve in
framed wall opening. Nail sleeve
securely to the frame with a tilt
(one full bubble) to the outside.
9t
bn
cabinet
Place the foam
seat between the
front edge of the
air conditioner
base and the
bottom flange
of the Through-the-Wall
base
cabinet. Slide the air conditioner
into the sleeve.
10.
tab-
Remove sheet metal
screws from air
conditioner front
base flange. Insert
tabs on the top edge
of front panel into
slots in the air
conditioner cabinet.
Use two sheet metal screws to
attach the bottom of the front
panel to the cabinet.
Ttih 01
4a
Corporation
11
Use insulation to seal
n
openina between
cabinet and’frame Caulk outside
wall openings around cabinet.
12
If needed, install
I molding around room
side of cabinet. -
If ybur air conditioner is not
operating properly...
Check that the circuit breaker is
not tripped or house fuse blown.
Check that power supply cord is
securely plugged into the
electrical outlet.
If you need assistance...
The, Whirlpool Consumer
Assistance Center will answer any
questions about operating or
maintaining your air conditioner
not covered in the Installation
Instructions. The Whirlpool
Consumer Assistance Center is
open 24 hours a day, 7 days a
week. Just dial l-800-253-1301 -
the call is free.
When you call, you will need the
air conditioner model number
and serial number. Both numbers
can be found on the model and
serial label located behind the
front panel on the base flange.
If you need service...
In the event that your Whirlpool
appliance should need service,
call the dealer from whom you
purchased the appliance or a
Whirlpool-authorized service
company. A Whirlpool-authorized
service company is listed in the
Yellow Pages of your telephone
directory under “Appliances -
Household - Major - Service or
Repair.” You can also obtain the
service company’s name and
telephone number by dialing,
free, within the continental United
States, the Whirlpool Consumer
Assistance Center telephone
number, 1-800-253-l 301. A
special operator will tell you the
name and number of your
nearest Whirlpool-authorized
service company.
Maintain the quality built into your
Whirlpool appliance - call a
Whirlpool-authorized service
company.
Pat-t No. 1163570 Rev. A
0 1993 Whirlpool Corporation Prepared by Whirlpool Corporation,
Benton Harbor, Michigan 49022 Printed in USA