3.3 Mounting the WhisperPower Touch Display
Createamountingholeaccordingtothedimensionspecicationsfoundbelow.Installthe
WhisperPower Touch screen panel. Fix the panel with the four clips with screws.
Pleasenotethetouchscreenpanelismeantforin-door/interioruse.Itmustbeinstalledina
dry and clean place protected from strong vibrations The touch screen panel must be
mounted so as to avoid any contact with acid from the battery, dust, rain, snow or liquids of
any type. Long exposure to direct sunlight may cause discoloration of the touch screen
panels.
WP-TOUCH 5”
PICCOLO/SCALINO
4/5 GENVERTER
WP-TOUCH 5”
SYSTEM PANEL
WP-TOUCH 7”
SYSTEM PANEL
WP-TOUCH
10”
SYSTEM
PANEL
Art. No. 40280105 40280100 40280101 40280102
External width (W1) 150 mm 150 mm 206 mm 280 mm
External length (L1) 110 mm 110 mm 139 mm 186 mm
External depth (D1) 40 mm 40 mm 40 mm 42 mm
Internalwidth(W2) 139 mm 139 mm 194 mm 248 mm
Internallength(L2) 91 mm 91 mm 117 mm 159 mm
Internaldepth(D2) 32 mm 32 mm 32 mm 34 mm
3.4 Connecting the WhisperPower Touch Display
WARNING!
Wrong or improper connections may cause damage to your WhisperPower Touch
screen panel or any other equipment connected to the system. Wrong installation
is not covered by guarantee.
-Remove the green 3 pole power connector from the rear side of the panel.
- Connect the DC (plus and minus) and the earth connection as shown on the
rear side of the panel.
- Connect the communication busses (WhisperConnect, WPC-bus, DDC bus)
of all the devices in the energy system as explained below. For more informa-
tion on installation of these communication busses see the section below
andthemanualofthespeciccommunicationbus.
- IfapplicableconnectthetouchpaneltotheWhisperCareequipment.Seethe
manual of WhisperCare for more details.
- Reconnect the green 3 pole power connector.
The power supply to the touch screen panel must be fused by a fast blow 3A fuse. All equip-
ment connected to the touch screen panel must be powered by a common ground supply.
For example this means the negative sides of the starter battery and service battery must be
connected together in a system. When it is not possible to create a common ground system,
one must use galvanic isolators on all communication busses. Galvanic isolators are standard
included with the 10 inch touch screen panel.