logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. White
  6. •
  7. Controllers
  8. •
  9. White WHI-SK20PPHS2 User manual

White WHI-SK20PPHS2 User manual

Popular Controllers manuals by other brands

Digiplex DGP-848 Programming guide

Digiplex

Digiplex DGP-848 Programming guide

YASKAWA SGM series user manual

YASKAWA

YASKAWA SGM series user manual

Sinope Calypso RM3500ZB installation guide

Sinope

Sinope Calypso RM3500ZB installation guide

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

Isimet

Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS sv-ip5a user manual

LSIS

LSIS sv-ip5a user manual

Airflow Uno hab Installation and operating instructions

Airflow

Airflow Uno hab Installation and operating instructions

ABB ACS580-01 drives Hardware manual

ABB

ABB ACS580-01 drives Hardware manual

Panasonic GM1 Series Reference manual

Panasonic

Panasonic GM1 Series Reference manual

Emerson SW93 owner's manual

Emerson

Emerson SW93 owner's manual

AutoAqua Smart ATO micro SATO-120P manual

AutoAqua

AutoAqua Smart ATO micro SATO-120P manual

Panasonic FP? Positioning Unit RTEX Technical manual

Panasonic

Panasonic FP? Positioning Unit RTEX Technical manual

Alpha IP MIOB 21001 manual

Alpha IP

Alpha IP MIOB 21001 manual

Siemens OpenAir GMA 1 Series Mounting instructions

Siemens

Siemens OpenAir GMA 1 Series Mounting instructions

Surecom SR-629 user manual

Surecom

Surecom SR-629 user manual

Regulus SRS1 T Installation and operation manual

Regulus

Regulus SRS1 T Installation and operation manual

3M MicroTouch EX113 reference guide

3M

3M MicroTouch EX113 reference guide

KUHN TKS user manual

KUHN

KUHN TKS user manual

S&C PMH Instructions for operation

S&C

S&C PMH Instructions for operation

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

WHI-SK20PPHS2 (2.2 bar Start Up)
AUTO RESTART
PUMP CONTROL
ELECTRONIC REGULATOR FOR ELECTRIC PUMPS
SPECIFICATIONS
Input Voltage 240V Maximum working pressure 10bar
Frequency 50Hz Max working temperature 60°C
Current Max. 16A Connection 1” male BSP
Protection Rating IP65
UNIT STARTING AND WORKING
Warning
Never take the electronic board out of the control box.
The wiring diagram inside the terminal block will show you how to correctly wire
the controller.Wrong connection will destroy the whole electronic circuit.
Cable used for connection must be a three-wired one with compulsory grounding
end. It shall have the outer diameter at 7.5mm min and 8.5mm max. One of the
the cable beingconnected to the power as shown in the Figure below.
fastened to avoid water entering into the control box and damaging the electronic
circuit.
STARTING
When the unit is connected to the electrical network, the green led “Power On” lights up and the
yellow led “On” (pump in operation) 2 seconds later indicating that the pump has been started.
reach the required pressure.
pressed and wait, with a tap opened, until the red led is off.
Once the button is released the tap is closed, the unit stops the pump at its maximum pressure.
FUNCTIONING
This unit is programmed to perform all the pump control operation automaticlly.
When breakdowns occur, such as water failure, obstruction of the suction pipe etc., the unit can
prevent damages caused by its working in the absence of water.
When there is no water supply to the system, the water pump will stop automatically after 20s
running and the red led will glint.The water pump runs automatically for 40s after stopping for 10s
and checks the water supply; If there is no water supply, the water pump runs automatically for
40s after stopping for 10s again and checks the water supply; If there is still no water supply, the
water pump will stop automatically and turn to the dry - running protection status.After 24 hours,
the pump will start automatically and repeat the above procedures. During stopping the pump, the
pressing the “Restart” button.
L1-1- 240V~50Hz
INSTRUCTIONS FOR CORRECT UNIT INSTALLATION
If the column of water
between the pump and the
highest tap exceeds 20m,
the unit cannot be installed
directly on the pump, but it
has to be raised until the
column of water between
the unit and the highest
tap does not exceed 20m.
i.e. If column of water is
25m from the pump, the
unit must be placed 5m
higher than the pump.
It is advisable to connect
the unit outlet to the
system by means of a
Safety valve preventing
water emission in case of
diaphram breaks
DO NOT TOUCH
It is imperative to install
the unit with the arrows in
the upwards position.
The unit can be installed
directly on the pump, or
between the pump and the
The unit is equipped with
a check valve to prevent
the pipeline from losing
pressure.
NO taps can be installed
between the pump and the
unit.
PUMP’S PRESSURE
The unit is pre-set by the
manufacturer at a restarting
pressure of 2.2 bar.
The pressure produced by
the pump must be normally
0.8 bar higher than the
pre-set pressure.
Before starting the unit
check suction and ensure
that the pump is primed.
20m max
Wiring diagram for
connection of single phase
240V pumps up to 1.5kW.
POSSIBLE WORKING DEFECTS
TYPE OF
DEFECT
CAUSES DEPENDING
ON THE UNIT
CAUSES NOT DEPENDING
ON THE UNIT
The pump
does not start
The electronic card is broken Voltage failure
Pump jammed
Electric cables inverted (line/
motor)
The pump
does not stop
The electronic card is broken
in the upper position
The reset button is blocked
The pump does not provide
Presence of leaks which are higher
min
Intermittent
pump working
The electronic card is broken
The pump does not provide
Presence of leaks which are lower
min
The pump is
jammed
The electronic card is broken
The pump provides a
pressure which is lower than
the restarting pressure
Water failure
Suction problems
WIRING DIAGRAMS FOR CONNECTING THE
UNIT TO DIFFERENT KINDS OF PUMP MOTORS
Installation and maintenance of
the controller must be performed
by a qualified professional.
L1-1- 240V~50Hz
INSTRUCTIONS FOR CORRECT UNIT INSTALLATION
If the column of water
between the pump and the
highest tap exceeds 20m,
the unit cannot be installed
directly on the pump, but it
has to be raised until the
column of water between
the unit and the highest
tap does not exceed 20m.
i.e. If column of water is
25m from the pump, the
unit must be placed 5m
higher than the pump.
It is advisable to connect
the unit outlet to the
system by means of a
Safety valve preventing
water emission in case of
diaphram breaks
DO NOT TOUCH
It is imperative to install
the unit with the arrows in
the upwards position.
The unit can be installed
directly on the pump, or
between the pump and the
The unit is equipped with
a check valve to prevent
the pipeline from losing
pressure.
NO taps can be installed
between the pump and the
unit.
PUMP’S PRESSURE
The unit is pre-set by the
manufacturer at a restarting
pressure of 2.2 bar.
The pressure produced by
the pump must be normally
0.8 bar higher than the
pre-set pressure.
Before starting the unit
check suction and ensure
that the pump is primed.
20m max
Wiring diagram for
connection of single phase
240V pumps up to 1.5kW.
POSSIBLE WORKING DEFECTS
TYPE OF
DEFECT
CAUSES DEPENDING
ON THE UNIT
CAUSES NOT DEPENDING
ON THE UNIT
The pump
does not start
The electronic card is broken Voltage failure
Pump jammed
Electric cables inverted (line/
motor)
The pump
does not stop
The electronic card is broken
in the upper position
The reset button is blocked
The pump does not provide
Presence of leaks which are higher
min
Intermittent
pump working
The electronic card is broken
The pump does not provide
Presence of leaks which are lower
min
The pump is
jammed
The electronic card is broken
The pump provides a
pressure which is lower than
the restarting pressure
Water failure
Suction problems
WIRING DIAGRAMS FOR CONNECTING THE
UNIT TO DIFFERENT KINDS OF PUMP MOTORS
Installation and maintenance of
the controller must be performed
by a qualified professional.
WHI-SK20PPHS2 (2.2 bar Start Up)
AUTO RESTART
PUMP CONTROL
ELECTRONIC REGULATOR FOR ELECTRIC PUMPS
SPECIFICATIONS
Input Voltage 240V Maximum working pressure 10bar
Frequency 50Hz Max working temperature 60°C
Current Max. 16A Connection 1” male BSP
Protection Rating IP65
UNIT STARTING AND WORKING
Warning
Never take the electronic board out of the control box.
The wiring diagram inside the terminal block will show you how to correctly wire
the controller.Wrong connection will destroy the whole electronic circuit.
Cable used for connection must be a three-wired one with compulsory grounding
end. It shall have the outer diameter at 7.5mm min and 8.5mm max. One of the
the cable beingconnected to the power as shown in the Figure below.
fastened to avoid water entering into the control box and damaging the electronic
circuit.
STARTING
When the unit is connected to the electrical network, the green led “Power On” lights up and the
yellow led “On” (pump in operation) 2 seconds later indicating that the pump has been started.
reach the required pressure.
pressed and wait, with a tap opened, until the red led is off.
Once the button is released the tap is closed, the unit stops the pump at its maximum pressure.
FUNCTIONING
This unit is programmed to perform all the pump control operation automatically.
If no water is supplied to the system, i.e no water in tank or closed supply/suction pipe, the system
will run the following sequence: Switch off after 20 seconds if no water is detected, stop for 10
seconds, run for 40 seconds stop for 10 seconds, run for 40 seconds stop for 10 seconds. The
controller at this point will go into run dry protection. The power light will stay illuminated and
the Failure light will flash slowly after this time. When the failure light is flashing, it means the
pump will restart after 24 hours in the sequence mentioned above. The system will repeat this
every 24 hours until water is detected.
The pump can be restarted at any time by pressing the reset button.