manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. WHITECROFT LIGHTING
  6. •
  7. Floodlight
  8. •
  9. WHITECROFT LIGHTING SELISE User manual

WHITECROFT LIGHTING SELISE User manual

Other WHITECROFT LIGHTING Floodlight manuals

WHITECROFT LIGHTING Selise Maxi User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Selise Maxi User manual

WHITECROFT LIGHTING Euroflood MidiLED Manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Euroflood MidiLED Manual

WHITECROFT LIGHTING Selise Maxi User manual

WHITECROFT LIGHTING

WHITECROFT LIGHTING Selise Maxi User manual

Popular Floodlight manuals by other brands

V-TAC VT-5192S installation instructions

V-TAC

V-TAC VT-5192S installation instructions

Major tech HLF30CW instruction manual

Major tech

Major tech HLF30CW instruction manual

EuroLite LED Cube user manual

EuroLite

EuroLite LED Cube user manual

EuroLite LED IP FL-100 SMD user manual

EuroLite

EuroLite LED IP FL-100 SMD user manual

Cooper Wheelock XB12 specification

Cooper Wheelock

Cooper Wheelock XB12 specification

Allen + Roth 17624-000 user manual

Allen + Roth

Allen + Roth 17624-000 user manual

ADJ 4 STAGE PAK User instructions

ADJ

ADJ 4 STAGE PAK User instructions

Cooper Lighting EGL91SW233 Specification sheet

Cooper Lighting

Cooper Lighting EGL91SW233 Specification sheet

Max 37496 instruction manual

Max

Max 37496 instruction manual

BEGA 85 143 Instructions for use

BEGA

BEGA 85 143 Instructions for use

Cameo CLPST64Q8W user manual

Cameo

Cameo CLPST64Q8W user manual

Beamz 151.226 user manual

Beamz

Beamz 151.226 user manual

EuroLite LED IP FL-8 user manual

EuroLite

EuroLite LED IP FL-8 user manual

Ledj PERFORMER 36 RGB user manual

Ledj

Ledj PERFORMER 36 RGB user manual

Perel ELS3 user manual

Perel

Perel ELS3 user manual

Perel ELS3WD user manual

Perel

Perel ELS3WD user manual

Xtricity 4-80053 instructions

Xtricity

Xtricity 4-80053 instructions

Stahl 6521/4 Series operating instructions

Stahl

Stahl 6521/4 Series operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Whitecroft Lighting Limited
Burlington Street, Ashton-under-Lyne, Lancashire OL7 0AX
Telephone +44 (0)870 5 087 087 Facsimile: +44 (0)870 5 084 210
Registered No. 3848973 England Registered Office: As above
May 2014 –Rev A
PK/LEAF/SELISE
GENERAL INFORMATION
1) A qualified electrician, in accordance with IEE wiring regulations should carry out connection to
mains wiring. Do not attempt to fit the luminaire whilst the mains supply is live.
2) Ensure that the rated voltage and frequency requirements are compatible with the available
mains supply.
3) Do not carry out high voltage insulation test, i.e. 500/1000v this may damage internal
components.
4) Some luminaires installed in outdoor environments may experience a build-up of internal
condensation. This is due to a difference in temperature between inside and outside the luminaire
which is quite common and acceptable under BSEN60598.
SPECIFICATION
Lamp types LED with wide, asymmetric or symmetric optics in 4000K
Materials Die cast aluminium body in graphite grey or silver finish
4mm thick glass luminaire cover
Supply 220V-240V
Power 25W to 94W dependant on Lumen output
Operating temp -20°C to +40°C
Ingress protection IP66
IK Rating IK08
Weight 4.0KG Small Housing
5.5KG Medium Housing
Mains Frequency 50/60Hz
DIMENSIONS
SELISE
SMALL AND MEDIUM LED FLOODLIGHTS
INSTALLATION INSTRUCTIONS
Installation Instructions
SMALL HOUSING
MEDIUM HOUSING
Class 2 product
1
2
TECHNICAL SUPPORT
Telephone: 0161 331 5700
E-mail: technical@whitecroftlight.com
http://www.whitecroftlighting.com/
INSTALLATION
Please note that this leaflet shows the installation process for both the small and
medium housing products. Any differentiation in the process will be highlighted.
SMALL HOUSING
MEDIUM HOUSING
1. Mount the unit to the wall using the diagram fig.1. Ensure that a suitable air gap between the
highest point of the luminaire and any features above is maintained. See fig. 2. Use suitable
mounting hardware.
SMALL HOUSING
MEDIUM HOUSING
2. To set the angle of the luminaire loosen the grub screw and then use a spanner to loosen
the nut. The luminaire will then freely pivot on the bracket. Once you have set the luminaire to
the desired angle tighten the nut with a spanner then tighten the grub screw to the torque
ratings as shown in fig.3. You may wish to set the angle before or after wiring the luminaire in
place. Note that you should not angle the luminaire greater than 100° off horizontal (fig.4).
SMALL HOUSING
MEDIUM HOUSING
3. To access the luminaire internals remove the 4
hex bolts from the upper section. The lower section
will come loose. Ensure you have hold of the lower
section as the two halves become disconnected as
fig 5.
Remove the internal terminal block cover if
required.
SMALL HOUSING
MEDIUM HOUSING
4. Wire the mains to the luminaire as per the images in fig.6. Feed through the mains
cable via the IP gland ensuring correct installation as to not compromise the integrity of
the product. Use a cable suitable for exterior use. The gland will accept wire with a
diameter between 9 and 12mm. This product is not suitable for through wiring.
5. To connect a DALI pair
to the internal LED driver
you will need to first
break an extra hole into
the luminaire housing
before using a suitable IP
gland and wire to the
terminal blocks as
specified in image 4.
6. Carefully reattach the
terminal block cover and
lower section (tighten
screws evenly) and
reinstate the mains
supply.