Whyte 5 Lite Series User manual

MULTISWITCH
INSTRUCTION MANUAL
Whyte
www.whytetechnologies.com
MODELS:
WM508L
WM512L
WM516L
WM524L
WM532L

www.whytetechnologies.com
2
Safety
Precauons
Guarantee
General Descripon
Product Descripon
Technical Descripon
Installaon Instrucons
Example Applicaon
Specicaons
3
3
3
4
5
6
6
9
10
CONTENTS

www.whytetechnologies.com 3
SAFETY
The Mulswitches are intended for indoor use only. Do not install the
Mulswitch in damp, humid, hot or dusty areas.
Switch o and remove the power supply when making connecons to the
Mulswitch to avoid damaging the unit.
Always earth bond the Mulswitch using the earth bonding lug and/or the
earth terminal bars to a suitable earth bonding point using minimum 4mm²
diameter earth cable.
PRECAUTIONS
To ensure trouble free operaon:
Do not remove the cover of the Mulswitch or disassemble it as this will
invalidate the guarantee.
The female F connectors on this unit were designed for use with '100' type
coaxial cable with a centre core diameter of 1mm². When using larger CT125
or CT167 cables, you must ensure that suitable F connectors with reducing
pins are used otherwise damage to the unit will occur which will invalidate the
guarantee.
Do not over ghten the F connectors (nger ght only).
GUARANTEE
All Whyte products are guaranteed for a period of 24 months from the date of
purchase.

www.whytetechnologies.com
4
The Whyte Series 5 Lite Standalone Mulswitch range is designed for domesc
installaons as well as for small apartment blocks. The range is compable with
both Quad and Quaro LNB’s and comes in sizes ranging from 8 way to 32 way.
Features include:
►Hi quality Standalone Mulswitch with 2 years warranty
►Industry leading performance at a compeve price
►Includes separate Power Supply Unit with F-Type DC Lead
►Gain SAT 0dB TERR 3dB
►Switchable12V supply to power Mast Head Amplier
►Colour coded inputs
►LED power indicator
►Inbuilt Hi-Rejecon LTE 4G lter
►Adequate clearance to route cables under the Mulswitch
GENERAL DESCRIPTION

www.whytetechnologies.com 5
1. SAT Inputs
2. TERR Input
3. Corner Brackets
4. Auxiliary 18V Input
5. LED Power Indicator
6. Subscriber (REC) Outputs
7. TERR 12V Switch
8. Earth Lug
PRODUCT DESCRIPTION

www.whytetechnologies.com
6
TECHNICAL DESCRIPTION
Whyte Series 5 Lite Mulswitches are compable with Quad and Quaro
LNB’s. The inputs are colour coded for ease of installaon which is especially
useful when using a Quaro LNB. For convenience, exisng satellite dishes
which are already ed with a Quad LNB may be used, whereby the drop
cables can be connected to the SAT inputs in no parcular order.
The 5 Lite range provides a nominal gain of 0dB(±2dB) for Satellite and
3dB(±2dB) Terrestrial Recepon. To facilitate the recepon of FM and DAB
radio at the outlets, the FM and DAB aerials must be combined with the
Terrestrial TV Aerial using a Triplexer. The combined signals are then connected
the TERR input of the Mulswitch.
A high rejecon LTE lter is ed to avoid interference from 4G LTE signals.
If required, a Terrestrial mast amplier can be powered via the mulswitch by
seng the 12V switch to the “ON” posion. If a mast amplier is not being
used, this switch must be le in the “OFF” posion.
The Power Supply Unit provided must be connected to the 18V DC Input. This
will power the Mulswitch as well as provide power to the Satellite LNB inputs.
A maximum of 500mA LNB power is available which enables the use of a line
powered launch amplier if required.
If a local mains supply is not available such as in los and outdoor cabinets, the
Power Supply Unit may be conveniently ed elsewhere whereby the 18V DC
F-Type lead can be extended using coaxial cable.
INSTALLATION INSTRUCTIONS
MOUNTING THE MULTISWITCH
Select a suitable locaon to install the Mulswitch. Do not install the
Mulswitch in damp, humid, hot or dusty areas. Using the screw slots on the

www.whytetechnologies.com 7
Corner Brackets, secure the Mulswitch using the appropriate xing screws
and wall plugs to suit the relevant wall surface or cabinet.
CONNECTING THE SAT & TERR INPUT CABLES
Use a suitably sized Satellite Dish to provide adequate signal levels from the
satellite being received. Ensure that the Satellite Drop Cables are connected
correctly in the corresponding order with respect to the LNB and the
Mulswitch SAT inputs (Quaro LNB only). Ensure that the F Connectors are
properly sealed against water ingress.
If a Composite Cable (mul core coaxial cable) has been used, ensure that the
outer jacket is not facing upwards and cannot collect rain water. Check the
Terrestrial Drop Cable and ensure that this has also been sealed against water
ingress. If a Triplexer has been used to combine FM and DAB aerials with the
UHF Terrestrial Aerial, ensure that this is also water ght. Ensure that all drop
cables have drip loops prior to their entering the building.
Connect the SAT and TERR drop cables to the corresponding Satellite & TERR
Inputs of the Mulswitch.
CONNECTING THE SUBSCRIBER CABLES
Terminate the Subscriber Cables with good quality F Connectors and connect
to the Subscriber Outputs. The F Connectors should be ed to the coaxial
cable correctly, ensuring that the centre core protrudes 3mm above the F
Connector body. See gure 3 (on page 8). Ensure that you do not exceed the
bending radius of the Coaxial Cable being used.
The Subscriber Cables may be arranged either side of the Mulswitch before
being terminated and connected. If required, the Subscriber Cables may be
arranged to one side of the Mulswitch, with the cables passing under the
Mulswitch before being terminated and connected to the Subscriber Outputs
on the opposite side. See gure 4 (on page 8). Always use CAI approved high
quality coaxial cable.

www.whytetechnologies.com
8
EARTH BONDING
Earth bond the Mulswitch to the Earth Bonding Lug using minimum 4mm²
Earth Bonding Cable. Make sure that the Earth Bonding Cable is connected
directly to the building’s PME (Protecve Mulple Earthing) point.
CONNECTING THE POWER SUPPLY UNIT (PSU)
The PSU must be xed to the relevant wall surface using the appropriate xings.
Connect the DC F-type lead to the 18V DC Input of the Mulswitch.
Once all connecons have been made, connect the plug to a 240V socket to
power up the Mulswitch. If a local mains supply is not available such as in
los and outdoor cabinets, the Power Supply Unit may be conveniently ed
elsewhere whereby the 18V DC F-Type lead may be extended using coaxial
cable.
Connecting the Subscriber Cables
Terminate the Subscriber Cables with good quality F Connectors and connect to the Subscriber
Outputs. The F Connectors should be fitted to the coaxial cable correctly, ensuring that the centre
core protrudes 3mm above the F Connector body. See figure 3. Ensure that you do not exceed the
bending radius of the Coaxial Cable being used. The Subscriber Cables may be arranged either
side of the Multiswitch before being terminated and connected. If required, the Subscriber Cables
may be arranged to one side of the Multiswitch, with the cables passing under the Multiswitch before
being terminated and connected to the Subscriber Outputs on the opposite side. See figure 4.
Always use CAI approved high quality coaxial cable.
Connecting the Power Supply Unit (PSU)
The PSU must be fixed to the relevant wall surface using the appropriate fixings. Connect the DC F-
type lead to the 18V DC Input of the Multiswitch.
Once all connections have been made, connect the plug to a 240V socket to power up the
Multiswitch. If a local mains supply is not available such as in lofts and outdoor cabinets, the Power
Supply Unit may be conveniently fitted elsewhere whereby the 18V DC F-Type lead may be extended
using coaxial cable.
5
Whyte
Earth Bonding
Earth bond the Multiswitch to the Earth Bonding Lug using minimum 4mm² Earth Bonding Cable.
Make sure that the Earth Bonding Cable is connected directly to the building’s PME (Protective
Multiple Earthing) point.
Figure 3
3mm
Figure 4

www.whytetechnologies.com 9
EXAMPLE APPLICATION
6
Whyte
Example Typical Application
Figure 5
SAT
TV FM DAB
TV Radio
SAT2
SAT1
Whyte
0.8A Power
Supply Unit
Model: WPSU-0.8A
Output: 18VDC 0.8A
Input: 110-240VAC 50/60Hz
Short Circuit Overload Protection

www.whytetechnologies.com
10
SPECIFICATIONS
7
Whyte
Example Application
Model
WM508L
WM512L
WM516L
WM524L
WM532L
Frequency
Satellite
950-2150MHz
950-2150MHz
950-2150MHz
950-2150MHz
950-2150MHz
Terrestrial
47-790MHz
47-790MHz
47-790MHz
47-790MHz
47-790MHz
Inputs (F Connectors)
4 SAT+1 TERR
4 SAT+1 TERR
4 SAT+1 TERR
4 SAT+1 TERR
4 SAT+1 TERR
Outputs (F Connectors)
8 Tap Outputs
12 Tap Outputs
16 Tap Outputs
24 Tap Outputs
32 Tap Outputs
Gain
SAT
0±2dB
0±2dB
0±2dB
0±2dB
0±2dB
TERR
3±2dB
3±2dB
3±2dB
3±2dB
3±2dB
TERR 12V DC Supply
(switchable)
100mA
100mA
100mA
100mA
100mA
Isolation
Trunk-Trunk
≥28dB
≥28dB
≥28dB
≥28dB
≥28dB
Cross-Polar
≥25dB
≥25dB
≥25dB
≥25dB
≥25dB
Tap-Tap (SAT)
≥25dB
≥25dB
≥25dB
≥25dB
≥25dB
Tap-Tap (TERR)
≥23dB
≥23dB
≥23dB
≥23dB
≥23dB
Rejection
≥20dB
≥20dB
≥20dB
≥20dB
≥20dB
Output
Level
SAT (IMA³-35dB)
100dBμV
100dBμV
100dBμV
100dBμV
100dBμV
TERR (IMA³-60dB)
>90dBμV
>85dBμV
>85dBμV
>85dBμV
>85dBμV
Switching Voltage
15±0.8V
15±0.8V
15±0.8V
15±0.8V
15±0.8V
LNB Power Max
500mA
500mA
500mA
500mA
500mA
Switching Commands
13V-18V
13V22k-18V22K
13V-18V
13V22k-18V22K
13V-18V
13V22k-18V22K
13V-18V
13V22k-18V22K
13V-18V
13V22k-18V22K
Current Consumption (DC In)
100mA Max
100mA Max
100mA Max
130mA Max
130mA Max
Dimensions (mm)
187x151x43
187x215x43
187x215x43
187x279x43
187x343x43
Weight
450g
550g
600g
700g
950g

www.whytetechnologies.com 11

www.whytetechnologies.com
@WhyteTech
@WhyteTechnologies
Whyte Technologies
@WhyteTechnologies
Whyte Technologies
Unit 13, Watermill Business Centre
Edison Road
Eneld, EN3 7XF
Phone: 0330 999 1980
E-mail: inf[email protected]
Whyte
Other manuals for 5 Lite Series
1
This manual suits for next models
5
Table of contents
Other Whyte Switch manuals