
Page 3Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Pre-Installation Information
When installing the Willoughby Industries' WODF-1-PET Series fountain system:
Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location.
The valve assembly, including the spray head, MUST NOT BE connected until after all lines have
been flushed to remove the small particles of debris that are inherent with new construction projects
and all chemicals that are used in flushing are purged from the system.
Chemicals used in flushing plumbing systems can attack the internal components of the valve and
spray head and severely damage them, so any flushing of the system must be followed by a full
flushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if
allowed to enter the valve assembly and spray head can cause poor performance or outright failure.
Again DO NOT attempt to connect the valve assembly and spray head until after all flushing is
complete and pure water is the only media that will be passing through the system. Damage to the
valve assembly or spray head caused by harsh chemicals or debris will not be covered by the
manufacturer's warranty.
Any fittings provided by the installer should be made of plastic to electrically isolate the unit from the
building or connected plumbing system.
The grounding of electric equipment such as telephones, computers, etc, to water lines is a common
procedure. This grounding can cause electrical feedback into a water fountain or similar fixture,
causing electrolysis, which results in a metallic taste or an increase in the metal content of the water.
This can easily be avoided by using the proper materials as indicated.
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up