Willoughby WODF-1-PET Series User manual

Rev. 10/2016
Installation &
Operation Manual
Willoughby Industries, Inc.
5105 West 78th Street
Indianapolis, IN 46268
Toll Free: (800) 428-4065
Local: (317) 875-0830
Fax: (317) 875-0837
www.willoughby-ind.com MADE IN THE U.S.A.
WODF-1-PET Series
Outdoor Pet Drinking Fountain
Table of Contents
Pre-Installation Information.....................................3
Physical Dimensions ..............................................4
Rough-In Dimensions.............................................5
Required Installation Supplies................................6
Hardware Identification Chart.................................7
Installation Instructions.............................................
Step 1: Fixture Installation.................................8
Step 2: Adjusting Drinking Spout Flow...............9
Care and Maintenance.........................................10
Troubleshooting....................................................11
Detail Drawings ........................................................
General Dimensions.........................................12
Exploded View w/BOM.....................................13
Rough-in Dimensions.......................................14
Freeze Resistant Valve Installation Detail........15
Warranty...............................................................16
WODF-1-PET

Page 2Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
(Page intentionally left blank)

Page 3Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Pre-Installation Information
When installing the Willoughby Industries' WODF-1-PET Series fountain system:
Before Step 1 of the installation instructions, ensure that rough-ins are in the correct location.
The valve assembly, including the spray head, MUST NOT BE connected until after all lines have
been flushed to remove the small particles of debris that are inherent with new construction projects
and all chemicals that are used in flushing are purged from the system.
Chemicals used in flushing plumbing systems can attack the internal components of the valve and
spray head and severely damage them, so any flushing of the system must be followed by a full
flushing with pure water to clear any harsh chemicals remaining in the system. Debris in the system if
allowed to enter the valve assembly and spray head can cause poor performance or outright failure.
Again DO NOT attempt to connect the valve assembly and spray head until after all flushing is
complete and pure water is the only media that will be passing through the system. Damage to the
valve assembly or spray head caused by harsh chemicals or debris will not be covered by the
manufacturer's warranty.
Any fittings provided by the installer should be made of plastic to electrically isolate the unit from the
building or connected plumbing system.
The grounding of electric equipment such as telephones, computers, etc, to water lines is a common
procedure. This grounding can cause electrical feedback into a water fountain or similar fixture,
causing electrolysis, which results in a metallic taste or an increase in the metal content of the water.
This can easily be avoided by using the proper materials as indicated.
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up
Installation notice!
Check Rough-In location PRIOR to installation
Flush lines thoroughly PRIOR to hook-up

Page 4Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Physical Dimensions- WODF-1-PET
15-7/8"
9-1/2"
9/16" THRU ALL4X
14-1/2" 4-1/4"
12-1/2"
BOLT CIRCLE
7"
10-3/4"
4-3/8"
3-13/16"

Page 5Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Rough-In Dimensions WODF-1-PET
3/8" O.D. SUPPLY CONNECTION
#600285
VALVE CARTRIDGE
1/4" TUBE
#980632
INLINE STRAINER
1/4" TO 3/8" PRESS LOCK
NOTE:
VALVE ASSEMBLY DETAIL
NOTE:
UNIT MUST BE DISCONNECTED AND DRAINED DURING
WINTERIZATION, PER THE FOLLOWING RECOMMENDED
PRACTICES:
SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY•STOP AND WATER LINES BY OTHERS)
DISCONNECT AND REMOVE IN-LINE FILTER•PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS•TO ALLOW WATER LINES TO DRAIN
(BY OTHERS)
1-1/2" PVC COUPLING
WATER SUPPLY LINE
(BY OTHERS)
4X 1/2"-13 UNC X 4"
(BY OTHERS)
CONCRETE PAD
CONCRETE ANCHORS
(BY OTHERS)
OTHERS)
SERVICE SHUT-OFF VALVE (BY
OPEN HUB DRAIN TO BE 1-1/2" IPS
MINIMUM TO A POROUS GRAVEL FILL OR
MAIN SEWER LINE LOCATED BELOW
FROST LINE (BY OTHERS)
4X 9/16" THRU ALL
BOLT CIRCLE
12-1/2"
14-1/2"

Page 6Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Required Installation Supplies
• Proper mounting hardware
• Proper plastic fittings as indicated
• Hardware for waste oulet connections
• Gasket for waste outlet connection
• Shims (for installation if necessary)
• Supply piping
• Silicone caulk
• Plumbers putty
WARNING: Willoughby Industries does not assume any
responsibility for personal injury or damage to equipment
due to an improperly installed WODF-1-PET Series
Fountain

Page 7Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Hardware Identification Chart
1/4-20 x 1/2"
SECURITY SCREW
4500NSS
T27
1/4" PINNED TORX BIT
800115
1/4"-20 x 2"
FLAT HEAD SECURITY SCREW
4509SSN
3/4" NPT
BRASS LOCKNUT
600612N
6-32 x 1/4"
SOCKET HEAD CAP SCREW
800157
1/4"-20 x 1/2"
PHILLIPS SCREW
800144

Page 8Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Installation Instructions
Step 1: Fixture Installation
Note: the WODF-1-PET outdoor fountain is to be mounted on a flat, level surface
(concrete or otherwise) with an adequate support structure.
Note: refer to Rough-In Dimensions for locating plumbing connections.
1.) Install service shut-off valve in water supply line (valve not furnished).
2.) Locate and install drinking fountain using 1/2"-13 x 4" concrete anchors (anchors not furnished).
3.) As noted previously, flush the water supply line with clean drinking water before making final
connections to the drinking fountain.
4.) Connect water supply line to inline strainer inside drinking fountain using 3/8" plastic tubing
(extra tubing not furnished). Push tube straight into fitting on filter about 3/4" until it reaches a
positive stop. Water supply connection must comply with local codes.
5.) Connect fountain drain line to drainage system. Drain is to be 1-1/2" IPS minimum to a porous
gravel flll or main sewer line located below frost line. Installer to provide waste trap downstream
of drain connection. Drain and waste trap must comply with local codes.
6.) Turn on water supply and check both the water supply lines and drain lines for leaks.

Page 9Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Step 2: Adjusting Drinking Spout Flow
1.) Remove valve box screws.
2.) Remove valve box cover and push button (together).
3.) Remove spring.
4.) Insert a standard flat-head screwdriver into adjustment opening of valve, as shown in Figure 4.
5.) Rotate screwdriver to adjust until desired flow is achieved.
a.) Rotate clockwise to increase flow.
b.) Rotate counterclockwise to decrease flow.
SPRING
VALVE BOX SCREWS
VALVE BOX COVER
w/ PUSHBUTTON
Removing valve box cover
Installation Instructions (cont.)
STANDARD SCREWDRIVER
(FLAT-HEAD)
Adjusting flow with screwdriver

Page 10Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Care and Maintenance
Stainless Steel Care
Stainless Steels are basically alloys of iron and chromium and are corrosion resistant. Stainless
steel has a bright surface that is easy to clean and is free from oxides. Therefore, cleaning of
stainless steel is relatively simple and easy if done on a regular basis.
)UHTXHQF\RIFOHDQLQJVKRXOGGHSHQGRQWKHUDWHDWZKLFKWKH¿[WXUHEHFRPHVGLUW\5HPHPEHU
that fresh (soft) deposits of all kinds are relatively easy to remove, while removing older (hard)
GHSRVLWVDUHPXFKPRUHGLI¿FXOW(VWDEOLVKDFOHDQLQJ6&+('8/(
5RXWLQH FOHDQLQJ VKRXOG LQYROYH RUGLQDU\ VRDS RU GHWHUJHQW DQG ZDWHU DSSOLHG ZLWK D VSRQJH
brush or cloth. Baking soda, borax or any of several non-abrasive commercial cleansing agents
FDQKHOSKDVWHQWKHFOHDQLQJDFWLRQ$IWHUVFUXEELQJULQVH7+2528*+/<DQGZLSHGU\
'2127XVHFRPPRQVWHHOZRROVFRXULQJSDGVVFUDSHUVZLUHEUXVKHV¿OHVRURWKHUVWHHOWRROVWR
clean stainless steel. Such items will scratch the surface or leave small particles of iron imbedded
in the surface, which will eventually rust and stain the surface - even appearing as if the stainless
itself was rusting.
&HUWDLQFKHPLFDOFRPSRXQGVLIXVHGRQVWDLQOHVVVWHHOFDQJLYHWKHDSSHDUDQFHRIUXVWDQGLI
allowed to stand for long periods of time, can pit the surface of even stainless. Products containing
hydrochloric acid, muriatic acid or potassium hydrochloride can ruin the surface.
Unit Care
Willoughby Industries’WODF Outdoor Drinking Fountains are not freeze resistant without the FRV
Freeze Resistant Valve option. The unit should be disconnected or shut off from the water supply
and drained during the colder months. For more information, refer to the rough-in detail.
In order to ensure adequate flow and cleanliness of water, the inlLne strainer in the supply line
should be cleaned or replaced regularly. New inline strainers can be ordered using Willoughby Part
No. 980632.

Page 11Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Troubleshooting
I. Insufficient Flow
A. Ensure the service shut-off valve is fully open (provided by installer).
B. Ensure water supply is within the normal operating range of 40-60 psi.
1. If pressure is too low, flow can be drastically reduced.
2. If pressure is too high, the strainer and/or valve may have been damaged.
3. The unit is rated for a maximum range of 30-105 psi.
C. Inspect the unit's valve for damage, and replace if necessary.
D. Inspect the inline strainer for damage and/or clogging, and clean or replace as necessary.
E. Check all fittings and tubing for damage and leaks. Replace components as necessary.
II. Unit has problems draining
A. Remove any debris from the drain.
B. Remove any debris from the PVC pipe and fittings.
C. Check and clear the waste trap (provided by installer).

Page 12Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
DRAWING: General Dimensions
15-7/8"
9-1/2"
9/16" THRU ALL4X
14-1/2" 4-1/4"
12-1/2"
BOLT CIRCLE
7"
10-3/4"
1
Indianapolis, Indiana BEH
EEF 3/16/15
10-08-14
C1 OF 3
P0711-0003
1:5
2 PLCS: SIZE:
OUTDOOR PET DRINKING FOUNTAIN
SHEET:REV.:
ORIG.:REVISION:
SCALE: REF.:
MAT'L:
PART #:
A
ANGLE:
WODF-1-PET
TITLE / DESC.:
FRACTIONS:
3 PLCS:
EXCEPT AS
TOLERANCES
NOTED
0.03
0.015
1/32"
Willoughby Industries, Inc.
STANDARD
4-3/8"
3-13/16"
WILLOUGHBY

Page 13Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
DRAWING: Exploded View w/BOM
NOTE: WILLOUGHBY PART #600471 - 1/4" TUBING
NOT SHOWN IN EXPLODED VIEW.
ITEM
#PART # DESCRIPTION QT
Y.
1 S200223 WELDED BODY ASSEMBLY 1
2 320280 PVC PIPE, 1-1/2" SCHED. 40 X 2-15/16" LONG 1
3 320284 PVC THREADED ADAPTER, 1-1/2" 1
4 S200031 RECEPTOR SUPPORT ASSEMBLY 1
5 800144 1/4-20 X 1/2" PHILLIPS TRUSS HEAD SCREW 3
6 320437 ADAPTER, 3/8" NPTF MALE X 1/4" TUBE PUSH-TO-CONNECT 1
7 320091 COUPLING, 3/8" FPT STAINLESS STEEL 1
8 320469 NIPPLE, 3/8" NPT X 2.5" LONG 1
9 600612N HEXNUT, 3/4"-14 NPSM 2
10 600116 O-RING, #023, BUNA N-70 1
11 4509SSN 1/4"-20 x 2" FH SECURITY SCREW 1
12 S200237 PET BOWL - 1-3/4" DEPTH 1
13 980632 STRAINER, IN-LINE, 1/4 TO 3/8 PRESS LOCK 1
14 380113 PUSH PIN FOR PET FOUNTAIN ADJUSTABLE PUSHBUTTON VALVE 1
15 800157 6-32 x 1/4" SH CAP SCREW 1
16 4500NSS 1/4-20 X 1/2" BUTTON HEAD SECURITY SCREW 3
17 S200249 COVER ASSEMBLY, VALVE, WODF-1-PET 1
18 980142 SPRING FOR PET FOUNTAIN ADJUSTABLE PUSHBUTTON VALVE 1
19 380112 SLEEVE FOR PET FOUNTAIN ADJUSTABLE PUSHBUTTON VALVE 1
20 600286 NUT, CARTRIDGE MOUNTING 1
21 600285 SELF-CLOSING CARTRIDGE, 1.0 GPM 1
22 600471 TUBING, 1/4" O.D. X 0.17" I.D. X 18" LONG 1
24 600601HE DECK MOUNTED DRINKING FOUNTAIN BUBBLER 1
Indianapolis, Indiana BEH
EEF 3/16/15
10-08-14
C2 OF 3
P0711-0003
1:6
PART #:
1
OUTDOOR PET DRINKING FOUNTAIN
SHEET:REV.:
ORIG.:REVISION:
SCALE: REF.:
MAT'L:
TITLE / DESC.: WODF-1-PET
SIZE:
NOTED
EXCEPT AS
TOLERANCES A
ANGLE:
3 PLCS:
FRACTIONS:
2 PLCS: 0.03
0.015
1/32"
Willoughby Industries, Inc.
STANDARD
12
11
24
9
8
7
6
4
3
2
1
13
19
5
10
14
15
18
9
20
21
16
17
C
WILLOUGHBY

Page 14Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
DRAWING: Rough-in Dimensions
3/8" O.D. SUPPLY CONNECTION
#600285
VALVE CARTRIDGE
1/4" TUBE
#980632
INLINE STRAINER
1/4" TO 3/8" PRESS LOCK
NOTE:
VALVE ASSEMBLY DETAIL
NOTE:
UNIT MUST BE DISCONNECTED AND DRAINED DURING
WINTERIZATION, PER THE FOLLOWING RECOMMENDED
PRACTICES:
SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY•STOP AND WATER LINES BY OTHERS)
DISCONNECT AND REMOVE IN-LINE FILTER•PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS•TO ALLOW WATER LINES TO DRAIN
Indianapolis, Indiana BEH
EEF 3/16/15
10-08-14
C3 OF 3
P0711-0003
1:8
PART #:
1
OUTDOOR PET DRINKING FOUNTAIN
SHEET:REV.:
ORIG.:REVISION:
SCALE: REF.:
MAT'L:
TITLE / DESC.: WODF-1-PET
SIZE:
NOTED
EXCEPT AS
TOLERANCES A
ANGLE:
3 PLCS:
FRACTIONS:
2 PLCS: 0.03
0.015
1/32"
Willoughby Industries, Inc.
STANDARD
(BY OTHERS)
1-1/2" PVC COUPLING
WATER SUPPLY LINE
(BY OTHERS)
4X 1/2"-13 UNC X 4"
(BY OTHERS)
CONCRETE PAD
CONCRETE ANCHORS
(BY OTHERS)
OTHERS)
SERVICE SHUT-OFF VALVE (BY
OPEN HUB DRAIN TO BE 1-1/2" IPS
MINIMUM TO A POROUS GRAVEL FILL OR
MAIN SEWER LINE LOCATED BELOW
FROST LINE (BY OTHERS)
4X 9/16" THRU ALL
BOLT CIRCLE
12-1/2"
14-1/2"
WILLOUGHBY

Page 15Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
DRAWING: Freeze Resistant Valve Installation Detail

Page 16Rev. 10/2016 www.willoughby-ind.com
Installation & Operation Manual
Outdoor Pet Drinking Fountain
WODF-1-PET Series
Willoughby Industries, Inc. TOLL FREE (800) 428-4065 ●LOCAL (317) 875-0830 ●FAX (317) 875-0837
Warranty
Willoughby Industries, Inc. warrants to commercial and institutional purchasers only that each unit
will be free from defects in workmanship and materials under normal use and service upon the
following terms and conditions for a period of one (1) year from date of shipment.
This warranty does not cover installation or any other labor charges and does not apply to any
components damaged by accident, abuse, improper installation or improper maintenance. This
warranty does not cover any installation that did not comply with national, state and local building,
plumbing or electrical codes. The warranty is limited to replacing or repairing at manufacturer’s
option, transportation charges prepaid by the purchaser, any component or part which upon our
inspection shall be deemed as defective within the limitations of this warranty. The replacement or
repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser
and the sole liability of Willoughby Industries, Inc. Willoughby Industries, Inc. shall not otherwise be
liable under any indirect damages caused by defects in the repair or replacement thereof.
This warranty only extends to commercial and industrial purchasers and does not extend to any
others, including consumer customers of commercial institutional purchasers. This warranty is in
lieu of all other warranties, expressed or implied, including implied warranty of merchantability or
¿WQHVVIRUDSDUWLFXODUSXUSRVHRURWKHUZLVH
Other manuals for WODF-1-PET Series
1
Table of contents
Other Willoughby Pet Care Product manuals
Popular Pet Care Product manuals by other brands

whisker
whisker Litter Robot quick start guide

Savic
Savic Geneva Assembly instructions

Petsafe
Petsafe In-Ground Fence System Operating and training guide

Petsafe
Petsafe In-Ground Cat Fence Operating and training guide

CEVA
CEVA FELIWAY FRIENDS Instructions for use

Garmin
Garmin ATEMOS 50 WITH K5 owner's manual