manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Willoughby
  6. •
  7. Plumbing Product
  8. •
  9. Willoughby LRFC 703000IR User manual

Willoughby LRFC 703000IR User manual

INSTALLATION AND
OPERATION MANUAL
PAGE 1
© Rev. 2/2021
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
WILLOUGHBY INDUSTRIES
ACCESSORY
IR FAUCET ASSEMBLY
SEE FOLLOWING PAGES FOR FAUCET
DIMENSIONS AND PART NUMBERS
LRFC PART#: 703000IR / 703000BO
LIGATURE-RESISTANT IR FAUCET
STANDARD FEATURES
- Willoughby (LRFC) Ligature-resistant IR faucet is designed to allow users
to wash without the use of pushbuttons.
- Specically for mental & behavioral healthcare facility use.
- Recommended operational pressure, 35-70 PSI.
DISASSEMBLY
1. Unscrew the (2) 1/4-20 nuts on the all thread rod and take off the lock
washers and centering washers.
INSTALLATION
1. Make sure the deck gasket for the faucet is on the faucet and both
all-thread rods, PTC tting, and wires for the IR valve are through the
gasket.
Note: Faucet can be mounted with or without the gasket and the
bottom edge sealed with non-pick caulking.
2. From the underside of the xture, align the (2) 1/4-20 all-thread
rods with the mounting holes, making sure the PTC tting and IR
sensor wires are going through the central hole.
3. Place the centering washer, lock washer and thread the nut onto the
all-thread rods (all included). Tighten the nuts down.
4. After thorough ushing, connect the faucet to the water line from the
valve using the 3/8" PTC Fitting (included).
If you have Plug-In infrared sensors, go to Page 2.
If you have Battery Operated infrared sensors, go to Page 3.
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 2 © Rev. 2/2021
FIG. 3- 24V AC SYSTEM INFRARED ASSEMBLY
FIG. 1- IR SENSOR
FIG. 2- IR REMOTE
DETECTION AND ACTIVATION
- When the sensor detects a user, a slow-ashing
red light appears in the sensor window.
- After 1-2 seconds of detection, the light ashes
rapidly, the sensor immediately activates the
solenoid valve, beginning water ow.
- The valve remains open while the user is detected.
- The valve closes when the user is no longer detected.
- The sensor is set to activate the solenoid valve for a
maximum of 30 seconds before automatically
shutting off.
Note: Sensor range is factory preset to 20";
Optional range adjustment remote available
to adjust range from 1" min. to 30" max.
(SEE FIG. 2).
INSTALLATION AND REPLACEMENT
1) Disconnect the 24V AC power at either the
transformer or fuse box.
2) Remove the faucet to expose the sensor and sensor
mounting bracket.
3) Remove the PTC tting and sensor mounting bracket.
4) Install the new sensor with arrow pointing
upwards (SEE FIG. 1).
4) Replace the sensor mounting bracket and PTC tting.
5) Remount the faucet to the xture making sure both the
red and black cables from the sensor are pushed
through the center hole.
6) Connect the red male power cable to the female
connector on the sensor (SEE FIG. 3).
7) Connect the black female solenoid cable to the
male connector on the sensor.
8) Reconnect the power.
(LRFC) FAUCET 24V AC System Infrared Sensor
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 3
© Rev. 2/2021
FIG. 3- BATTERY OPERATED INFRARED ASSEMBLY
FIG. 1- IR SENSOR
FIG. 2- IR REMOTE
DETECTION AND ACTIVATION
- When the sensor detects a user, a slow-ashing
red light appears in the sensor window.
- After 1-2 seconds of detection, the light ashes
rapidly, the sensor immediately activates the
latching solenoid valve, beginning water ow.
- The valve remains open while the user is detected.
- The valve closes when the user is no longer detected.
- The sensor is set to activate the latching solenoid
valve for a maximum of 30 seconds before
automatically shutting off.
Note: Sensor range is factory preset to 20";
Optional range adjustment remote available
to adjust range from 1" min. to 30" max.
(SEE FIG. 2).
INSTALLATION AND REPLACEMENT
1) Disconnect battery pack and remove it from cradle.
2) Remove the faucet to expose the sensor and sensor
mounting bracket.
3) Remove the PTC tting and sensor mounting bracket.
4) Install the new sensor with arrow pointing
upwards (SEE FIG. 1).
4) Replace the sensor mounting bracket and PTC tting.
5) Remount the faucet to the xture making sure both the
red and black cables from the sensor are pushed
through the center hole.
6) Connect the red male power cable to the female
connector on the sensor (SEE FIG. 3).
7) Connect the black female solenoid cable to the
male connector on the sensor.
8) Reconnect battery pack and place back into cradle.
(LRFC) FAUCET Battery Opperated Infrared Sensor
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 4 © Rev. 2/2021
(LRFC) FAUCET Dimensions
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 5
© Rev. 2/2021
(LRFC) FAUCET Part Numbers
703000IR
703000BO
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 6 © Rev. 2/2021
(LRFC) FAUCET Part Numbers
HARD-WIRED
BATTERY OPERATED
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 7
© Rev. 2/2021
DRAWING: 24V Electronic Valve Detail
3 4 6
7
2
1
5
EXPLODED VIEW
ASSEMBLED VIEW
ITEM #
PART #
DESCRIPTION
QTY.
1 980501
PM1 VALVE BRACKET
1
2 980183
CHECKSTOP ASSEMBLY
1
3
980408PR
E1L VALVE ASSEMBLY - RIGHT PLUGGED PORT
1
4 980140
SPRING CLIP, ROUND
2
5 800133
#10-16 SELF TAP TYPE B HEX HEAD SCREW
4
6
980600A
VALVE FITTING ASSEMBLY, 3/8" ELBOW
1
7 980520
20" FLEX HOSE, 1/2 F.I.P CONNECTION
1
EEF
NAL 11/30/20
2/5/15
A
1 OF 1
E1L11XXXXE
1:4
N/A
PART #:
VALVE ASSY ELECTRONIC SINGLE TEMP - NFC - LEAD FREE
SHEET:
REV.:
ORIG.:
REVISION:
SCALE:
REF.:
MAT'L:
TITLE / DESC.:
TOLERANCES
EXCEPT AS
NOTED
2 PLCS:
3 PLCS:
FRACTIONS:
ANGLE:
0.03
0.015
1/32"
1
A
SIZE:
Willoughby Industries, Inc.
Indianapolis, Indiana
STANDARD
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 8 © Rev. 2/2021
DRAWING: 9V Battery Operated Valve Detail
3 4 6
7
2
1
5
EXPLODED VIEW
ASSEMBLED VIEW
ITEM #
PART #
DESCRIPTION
QTY.
1 980501
PM1 VALVE BRACKET
1
2 980183
CHECKSTOP ASSEMBLY
1
3
980416PR
VALVE ASSY, BATTERY OPERATED, RH PLUGGED PORT
1
4 980140
SPRING CLIP, ROUND
2
5 800133
#10-16 SELF TAP TYPE B HEX HEAD SCREW
4
6
980600A
VALVE FITTING ASSEMBLY, 3/8" ELBOW
1
7 980520
20" FLEX HOSE, 1/2 F.I.P CONNECTION
1
NAL
NAL 11/30/20
11/30/20
A
1 OF 1
EBL11XXXXE
1:4
N/A
PART #:
VALVE ASSY, BATTERY OPERATED SINGLE TEMP - NFC - LEAD FREE
SHEET:
REV.:
ORIG.:
REVISION:
SCALE:
REF.:
MAT'L:
TITLE / DESC.:
TOLERANCES
EXCEPT AS
NOTED
2 PLCS:
3 PLCS:
FRACTIONS:
ANGLE:
0.03
0.015
1/32"
1
A
SIZE:
Willoughby Industries, Inc.
Indianapolis, Indiana
STANDARD

This manual suits for next models

1

Other Willoughby Plumbing Product manuals

Willoughby Aquafount WAF-3603 Series User manual

Willoughby

Willoughby Aquafount WAF-3603 Series User manual

Willoughby WWF-3606 User manual

Willoughby

Willoughby WWF-3606 User manual

Willoughby AquaFount WAF-3606 Series User manual

Willoughby

Willoughby AquaFount WAF-3606 Series User manual

Willoughby WH-1900 User manual

Willoughby

Willoughby WH-1900 User manual

Willoughby WH-2800 Series User manual

Willoughby

Willoughby WH-2800 Series User manual

Willoughby Aquafount WAF-5404 Series User manual

Willoughby

Willoughby Aquafount WAF-5404 Series User manual

Willoughby WAF-2200 Series User manual

Willoughby

Willoughby WAF-2200 Series User manual

Willoughby AquaFount WAF-4400 Series User manual

Willoughby

Willoughby AquaFount WAF-4400 Series User manual

Popular Plumbing Product manuals by other brands

Grohe Blue 31 251 installation instructions

Grohe

Grohe Blue 31 251 installation instructions

Hans Grohe Fixfit 27453003 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Fixfit 27453003 Instructions for use/assembly instructions

Bourgeat AQUARIS Instructions for use and maintenance

Bourgeat

Bourgeat AQUARIS Instructions for use and maintenance

deante BQH 028R Installation and Usage Instruction

deante

deante BQH 028R Installation and Usage Instruction

Linie MILA installation guide

Linie

Linie MILA installation guide

Moen TS2141 installation guide

Moen

Moen TS2141 installation guide

IKEA OPPEJEN 504.313.61 installation instructions

IKEA

IKEA OPPEJEN 504.313.61 installation instructions

Kohler 11829T-B installation instructions

Kohler

Kohler 11829T-B installation instructions

Helvex 110-38-3.5 installation guide

Helvex

Helvex 110-38-3.5 installation guide

Sanela SLP 54RB Instructions for use

Sanela

Sanela SLP 54RB Instructions for use

American Standard Coventry 0575.000 Dimensions

American Standard

American Standard Coventry 0575.000 Dimensions

Rohl CA2201LMAPC-2 installation instructions

Rohl

Rohl CA2201LMAPC-2 installation instructions

Brizo Artesso 64025LF Series manual

Brizo

Brizo Artesso 64025LF Series manual

IKEA SUNNERSTA manual

IKEA

IKEA SUNNERSTA manual

Alveus ULURU Fitting instructions

Alveus

Alveus ULURU Fitting instructions

Pura BW105 Installation & user guide

Pura

Pura BW105 Installation & user guide

American Standard Acclivity Countertop Sink 3409.001 Specification sheet

American Standard

American Standard Acclivity Countertop Sink 3409.001 Specification sheet

Sanela 93230 Mounting instructions

Sanela

Sanela 93230 Mounting instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.