INSTALLATION AND
OPERATION MANUAL
PAGE 1
© Rev. 2/2021
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
WILLOUGHBY INDUSTRIES
ACCESSORY
IR FAUCET ASSEMBLY
SEE FOLLOWING PAGES FOR FAUCET
DIMENSIONS AND PART NUMBERS
LRFC PART#: 703000IR / 703000BO
LIGATURE-RESISTANT IR FAUCET
STANDARD FEATURES
- Willoughby (LRFC) Ligature-resistant IR faucet is designed to allow users
to wash without the use of pushbuttons.
- Specically for mental & behavioral healthcare facility use.
- Recommended operational pressure, 35-70 PSI.
DISASSEMBLY
1. Unscrew the (2) 1/4-20 nuts on the all thread rod and take off the lock
washers and centering washers.
INSTALLATION
1. Make sure the deck gasket for the faucet is on the faucet and both
all-thread rods, PTC tting, and wires for the IR valve are through the
gasket.
Note: Faucet can be mounted with or without the gasket and the
bottom edge sealed with non-pick caulking.
2. From the underside of the xture, align the (2) 1/4-20 all-thread
rods with the mounting holes, making sure the PTC tting and IR
sensor wires are going through the central hole.
3. Place the centering washer, lock washer and thread the nut onto the
all-thread rods (all included). Tighten the nuts down.
4. After thorough ushing, connect the faucet to the water line from the
valve using the 3/8" PTC Fitting (included).
If you have Plug-In infrared sensors, go to Page 2.
If you have Battery Operated infrared sensors, go to Page 3.
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 2 © Rev. 2/2021
FIG. 3- 24V AC SYSTEM INFRARED ASSEMBLY
FIG. 1- IR SENSOR
FIG. 2- IR REMOTE
DETECTION AND ACTIVATION
- When the sensor detects a user, a slow-ashing
red light appears in the sensor window.
- After 1-2 seconds of detection, the light ashes
rapidly, the sensor immediately activates the
solenoid valve, beginning water ow.
- The valve remains open while the user is detected.
- The valve closes when the user is no longer detected.
- The sensor is set to activate the solenoid valve for a
maximum of 30 seconds before automatically
shutting off.
Note: Sensor range is factory preset to 20";
Optional range adjustment remote available
to adjust range from 1" min. to 30" max.
(SEE FIG. 2).
INSTALLATION AND REPLACEMENT
1) Disconnect the 24V AC power at either the
transformer or fuse box.
2) Remove the faucet to expose the sensor and sensor
mounting bracket.
3) Remove the PTC tting and sensor mounting bracket.
4) Install the new sensor with arrow pointing
upwards (SEE FIG. 1).
4) Replace the sensor mounting bracket and PTC tting.
5) Remount the faucet to the xture making sure both the
red and black cables from the sensor are pushed
through the center hole.
6) Connect the red male power cable to the female
connector on the sensor (SEE FIG. 3).
7) Connect the black female solenoid cable to the
male connector on the sensor.
8) Reconnect the power.
(LRFC) FAUCET 24V AC System Infrared Sensor
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 3
© Rev. 2/2021
FIG. 3- BATTERY OPERATED INFRARED ASSEMBLY
FIG. 1- IR SENSOR
FIG. 2- IR REMOTE
DETECTION AND ACTIVATION
- When the sensor detects a user, a slow-ashing
red light appears in the sensor window.
- After 1-2 seconds of detection, the light ashes
rapidly, the sensor immediately activates the
latching solenoid valve, beginning water ow.
- The valve remains open while the user is detected.
- The valve closes when the user is no longer detected.
- The sensor is set to activate the latching solenoid
valve for a maximum of 30 seconds before
automatically shutting off.
Note: Sensor range is factory preset to 20";
Optional range adjustment remote available
to adjust range from 1" min. to 30" max.
(SEE FIG. 2).
INSTALLATION AND REPLACEMENT
1) Disconnect battery pack and remove it from cradle.
2) Remove the faucet to expose the sensor and sensor
mounting bracket.
3) Remove the PTC tting and sensor mounting bracket.
4) Install the new sensor with arrow pointing
upwards (SEE FIG. 1).
4) Replace the sensor mounting bracket and PTC tting.
5) Remount the faucet to the xture making sure both the
red and black cables from the sensor are pushed
through the center hole.
6) Connect the red male power cable to the female
connector on the sensor (SEE FIG. 3).
7) Connect the black female solenoid cable to the
male connector on the sensor.
8) Reconnect battery pack and place back into cradle.
(LRFC) FAUCET Battery Opperated Infrared Sensor
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 4 © Rev. 2/2021
(LRFC) FAUCET Dimensions
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 5
© Rev. 2/2021
(LRFC) FAUCET Part Numbers
703000IR
703000BO
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 6 © Rev. 2/2021
(LRFC) FAUCET Part Numbers
HARD-WIRED
BATTERY OPERATED
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 7
© Rev. 2/2021
DRAWING: 24V Electronic Valve Detail
3 4 6
7
2
1
5
EXPLODED VIEW
ASSEMBLED VIEW
ITEM #
PART #
DESCRIPTION
QTY.
1 980501
PM1 VALVE BRACKET
1
2 980183
CHECKSTOP ASSEMBLY
1
3
980408PR
E1L VALVE ASSEMBLY - RIGHT PLUGGED PORT
1
4 980140
SPRING CLIP, ROUND
2
5 800133
#10-16 SELF TAP TYPE B HEX HEAD SCREW
4
6
980600A
VALVE FITTING ASSEMBLY, 3/8" ELBOW
1
7 980520
20" FLEX HOSE, 1/2 F.I.P CONNECTION
1
EEF
NAL 11/30/20
2/5/15
A
1 OF 1
E1L11XXXXE
1:4
N/A
PART #:
VALVE ASSY ELECTRONIC SINGLE TEMP - NFC - LEAD FREE
SHEET:
REV.:
ORIG.:
REVISION:
SCALE:
REF.:
MAT'L:
TITLE / DESC.:
TOLERANCES
EXCEPT AS
NOTED
2 PLCS:
3 PLCS:
FRACTIONS:
ANGLE:
0.03
0.015
1/32"
1
A
SIZE:
Willoughby Industries, Inc.
Indianapolis, Indiana
STANDARD
WILLOUGHBY INDUSTRIES
ACCESSORY FAUCET ASSEMBLY INSTALLATION & OPERATION MANUAL
1.800.428.4065 TOLL FREE
| www.willoughby-ind.com
PAGE 8 © Rev. 2/2021
DRAWING: 9V Battery Operated Valve Detail
3 4 6
7
2
1
5
EXPLODED VIEW
ASSEMBLED VIEW
ITEM #
PART #
DESCRIPTION
QTY.
1 980501
PM1 VALVE BRACKET
1
2 980183
CHECKSTOP ASSEMBLY
1
3
980416PR
VALVE ASSY, BATTERY OPERATED, RH PLUGGED PORT
1
4 980140
SPRING CLIP, ROUND
2
5 800133
#10-16 SELF TAP TYPE B HEX HEAD SCREW
4
6
980600A
VALVE FITTING ASSEMBLY, 3/8" ELBOW
1
7 980520
20" FLEX HOSE, 1/2 F.I.P CONNECTION
1
NAL
NAL 11/30/20
11/30/20
A
1 OF 1
EBL11XXXXE
1:4
N/A
PART #:
VALVE ASSY, BATTERY OPERATED SINGLE TEMP - NFC - LEAD FREE
SHEET:
REV.:
ORIG.:
REVISION:
SCALE:
REF.:
MAT'L:
TITLE / DESC.:
TOLERANCES
EXCEPT AS
NOTED
2 PLCS:
3 PLCS:
FRACTIONS:
ANGLE:
0.03
0.015
1/32"
1
A
SIZE:
Willoughby Industries, Inc.
Indianapolis, Indiana
STANDARD

This manual suits for next models

1

Other Willoughby Plumbing Product manuals

Willoughby Aquafount WAF-3603 Series User manual

Willoughby

Willoughby Aquafount WAF-3603 Series User manual

Willoughby WH-1900 User manual

Willoughby

Willoughby WH-1900 User manual

Willoughby WWF-3606 User manual

Willoughby

Willoughby WWF-3606 User manual

Willoughby WAF-2200 Series User manual

Willoughby

Willoughby WAF-2200 Series User manual

Willoughby Aquafount WAF-5404 Series User manual

Willoughby

Willoughby Aquafount WAF-5404 Series User manual

Willoughby AquaFount WAF-4400 Series User manual

Willoughby

Willoughby AquaFount WAF-4400 Series User manual

Willoughby WH-2800 Series User manual

Willoughby

Willoughby WH-2800 Series User manual

Willoughby AquaFount WAF-3606 Series User manual

Willoughby

Willoughby AquaFount WAF-3606 Series User manual

Popular Plumbing Product manuals by other brands

Moen SANI-STREAM 8797 manual

Moen

Moen SANI-STREAM 8797 manual

Grohe Allure Brilliant 19 784 manual

Grohe

Grohe Allure Brilliant 19 784 manual

Cistermiser Easyflush EVO 1.5 manual

Cistermiser

Cistermiser Easyflush EVO 1.5 manual

Kohler Triton Rite-Temp K-T6910-2A installation guide

Kohler

Kohler Triton Rite-Temp K-T6910-2A installation guide

BEMIS FNOTAB100 Installation instruction

BEMIS

BEMIS FNOTAB100 Installation instruction

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe ShowerTablet Select 700 13184000 Instructions for use/assembly instructions

Akw Stone Wash Basin Installation instructions manual

Akw

Akw Stone Wash Basin Installation instructions manual

Enlighten Sauna Rustic-4 user manual

Enlighten Sauna

Enlighten Sauna Rustic-4 user manual

Moen ShowHouse S244 Series quick start guide

Moen

Moen ShowHouse S244 Series quick start guide

Sanela SLWN 08 Mounting instructions

Sanela

Sanela SLWN 08 Mounting instructions

Franke 7612982239618 operating instructions

Franke

Franke 7612982239618 operating instructions

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Heritage Bathrooms

Heritage Bathrooms Granley Deco PGDW02 Fitting Instructions & Contents List

Tres TOUCH-TRES 1.61.445 instructions

Tres

Tres TOUCH-TRES 1.61.445 instructions

STIEBEL ELTRON WS-1 Operation and installation

STIEBEL ELTRON

STIEBEL ELTRON WS-1 Operation and installation

Miomare HG00383A manual

Miomare

Miomare HG00383A manual

BELLOSTA revivre 6521/CR1 quick start guide

BELLOSTA

BELLOSTA revivre 6521/CR1 quick start guide

American Standard Heritage Amarilis 7298.229 parts list

American Standard

American Standard Heritage Amarilis 7298.229 parts list

BorMann Elite BTW5024 quick start guide

BorMann

BorMann Elite BTW5024 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.