Winland Electronics WaterBug WB-200 Operating instructions

Electronic Water Detection Device
© 2012 Winland Electronics, Inc.
D-011-0116 Rev C (08/2012)
ONE YEAR LIMITED WARRANTY
Winland Electronics, Inc. (“Winland”) warrants to the end user/purchaser that each product of its manufacture shall be free from defects in material and
factory workmanship for a period of one year from the date of purchase, when properly installed and operated under normal conditions according to
Winland’s instruction. Winland’s obligation under this warranty is limited to correcting, without charge, at its factory any part or parts thereof which shall
be returned to the factory, by the original purchaser, transportation charges prepaid, within one year of the date of purchase and which upon examination,
shall disclose to Winland’s satisfaction to have been originally defective. Correction of such defects by repair to, or supplying replacements for, defective parts
shall constitute fulfillment of all Winland’s obligations to purchaser under this limited warranty. Repair service performed by Winland after one year from
date of purchase will be for a reasonable service charge. This limited warranty shall not apply to any of Winland’s products which have been subject to misuse,
negligence or accident or which have been repaired or altered outside of Winland’s factory. The warranty is void if the Product’s housing or cover is removed.
Winland shall not be liable for loss, damage or expense resulting, directly or indirectly, from the use of its products or any other cause. This warranty shall
be null and void in its entirety if: (i) the product is altered or modified in any way that is not consistent with the manufacturer’s instructions, or (ii) the
product is used with or connected to a device: (a) that such product is not intended to be used with or connected to, (b) is not otherwise consistent with the
manufacturer’s instructions, or (c) is not otherwise approved by the manufacturer. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES, NON-INFRINGEMENT AND TITLE, AND ANY
WARRANTIES ARISING FROM COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE. ALL OTHER REPRESENTATIONS MADE TO THE END USER/PURCHASER BY
ANY OTHER PARTY ARE ALSO EXCLUDED. WINLAND SHALL NOT BE LIABLE TO ANY PERSON FOR INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OF ANY DESCRIPTION, WHETHER ARISING OUT OF WARRANTY OR OTHER CONTRACT, NEGLIGENCE OR OTHER TORT, OR OTHERWISE. Under no circumstances
shall Winland’s liability under this limited warranty exceed the purchase price paid by the end user/purchaser for the product. No person, agent or dealer is
authorized to give warranties on behalf of Winland nor to assume for Winland any other liability in connection with any of its products.
SPECIFICATIONS
Power Requirement 8-28 VDC @ 35mA
8-28 VAC @ 100mA
Sensitivity Will not alarm due to high humidity or condensation.
Operating Temp 32˚ to 130˚F (0˚ to 54˚C); non-condensing environment (indoor use only)
Output 1 Form C Relay (N.O./N.C.)
1 Amp @ 30 VDC, resistive
1 Amp @ 24 VAC, resistive
Probe Options Includes 1 Standard Unsupervised Surface Probe (W-S-U)
Accepts up to 6 Unsupervised Surface Probes (W-S-U) wired in parallel or
Accepts up to 6 Unsupervised Under Carpet Probes (W-UC-U) wired in parallel.
Max Cable Length 1-2 probes; max recommended distance of 200’ (61 m)
3-6 probes; max recommended distance of 100’ (30.5 m)
Probe Cable Probes include 15' (4.6 m) cable. Extend using 22-18 AWG twisted pair.
Console Weight 2.4 oz (0.07 kg)
Console Dimensions 4.1 x 2.36 x 1.18” (10 x 6 x 3 cm) with flanges
Probe Dimensions Surface: 2 x 3 x 0.88” (5.1 x 7.6 x 2.2 cm)
Under Carpet: 2 x 3 x 0.18” (5.1 x 7.6 x 0.5 cm)
Mounting Flanges
Case Material ABS
Warranty 1 Year Limited
CONTENTS
This package contains:
• 1 WB-200
• 1 Surface Probe - Unsupervised (W-S-U)
• 1 Installation/Operating Instructions Guide
WB-200
ADDITIONAL PROBES
Multiple probes must be connected in parallel to the two
“sensor” terminals. The WB-200 accepts up to 6 probes
wired per console.
W-S-U
Water Probe - Surface
Unsupervised
W-UC-U
Water Probe - Under Carpet
Unsupervised
EPCOM - contact: [email protected]
San Diego, Cal El Paso, Tx Miami, Fl
(619) 661-9160 (915) 533-5119 (305) 889-1127
WEEE Product Recovery/Recycling for EU Customers
In an effort to improve waste management in the European Union, the European Union has enacted directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE Directive). According to the WEEE Directive, Winland Electronics must take back waste electrical or electronic equipment covered under the
WEEE Directive, at its cost, for all product it puts on the market after July 1, 2006. The Return Process: Contact Winland via our web site at www.winland.com.
Radio Frequency Interference Requirements: This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CE Marking and European Union Compliance: Products intended for sale within the European Union are marked with the CE Mark,
which indicates compliance to applicable Directives and European Norms (EN). Amendments to these Directives or ENs are included:
Electromagnetic Compatibility Directive 2004/108/EC; Low Voltage Directive 2006/95/EC; RoHS Directive 2002/95/EC; WEEE Directive
2002/96/EC.
Statement of Compliance: Winland Electronics, Inc. hereby declares that this device is in compliance with all the applicable Directives
2004/108/EC, 2006/95/EC, 2002/95/EC, 2002/96/EC.
Symbols on the Product or Manual Labeling
For product disposal, ensure the following:
• Do not dispose of this product as unsorted municipal waste.
• Collect this product separately.
• Use collection and return systems available to you.
WEEE Waste Electrical and Electronic Equipment
RoHS Restriction of Hazardous Substances

INTRODUCTION
Thank you for your purchase of the Winland WaterBug® model WB-200. The WB-200 is completely electronic and is designed
to detect water only (distilled and deionized water cannot be detected). The WB-200 is not a self contained warning device.
For proper operation, it must be used in conjunction with an alarm system, sounder, etc. It is designed so that the control
console mounts on a wall or other flat vertical surface and the remote probes are placed in the locations where water
leakage is most probable. Up to six remote probes may be connected to one control console. A film of moisture forming a
bridge between the two metallic contacts on any remote probe is all that is needed for the unit to signal an alarm condition.
The output on the WB-200 is non-latching, but will remain in alarm state until the moisture bridge is broken. As sensitive
as the WB-200 is, it will not alarm due to high humidity or condensation. The WB-200 is ideal for use in homes, offices,
computer rooms, warehouses, etc.
INSTALLATION
Locate the area where the WB-200 console is to be mounted. Using the WB-200 as a guide, mark the two locations on the
mounting surface where the holes will be drilled in order to use the case’s mounting flanges. If mounting on drywall, use the
two provided drywall anchors. Once the holes have been drilled, place the WB-200 against the surface and drive the screws
into the holes or anchors.
Multiple probes must be hooked up in parallel to the two “sensor” terminals. The remote surface probes may be mounted
securely to the floor or a wall. Mounting the probe(s) to a vertical surface like a wall enables you to monitor an area for rising
water levels. This is useful in basement sump pumps and other types of water storage and drainage systems.
TERMINAL BLOCK CONNECTIONS
Relay contacts are accessible on the terminal block (See
Figure 1). The WB-200 is in normal condition when
power is applied and no moisture is being detected. It’s
in alarm condition when water is detected by any one
of the remote probes.
Note: When connecting DC power to the WB-200 be
sure to observe polarity and test to see if the WB-200
is operating properly. This may be done by forming
a water bridge between two of the metallic contacts
located on the probe (See Figure 2) with a moistened
finger or cloth. If the WB-200 is not operating properly,
check the polarity of the power supply connections.
AC – Power input wires are interchangeable
DC – Positive to V+ and negative to Ground
TEST PROCEDURES
To test the WB-200 operational status, form a water bridge between the two metallic contact points (See Figure 2) with a
moistened finger or cloth. If working properly, the WB-200 will activate the warning device to which it is connected within
approximately three seconds. The WB-200 will reset automatically when the probe dries and there is no longer a water
bridge between the two metallic contact points.
WATER
WATER
WATER
WATER
VAC / +VDC
Relay Common
Relay N.O.
Relay N.C.
Ground (VAC / -VDC)
Figure 1
Figure 2
STANDARD SURFACE PROBE UNSUPERVISED
If a remote probe is to be bolted down in a permanent installation, drill
only in the innermost center recessed area (See Figure 3). Drilling anywhere
other than the innermost circle may damage the internal wiring causing the
WB-200 to fail.
MONITORING FOR THE ABSENCE OF WATER
The WB-200 can be used to monitor for the absence of water (water level).
This is done by:
1 - mounting the probe at the desired minimum waterline and ;
2 - using the opposite set of relay contacts that you would use if you were
detecting the presence of water.
ALARM NO ALARM
Four Probe Contacts
Mount the probe to ensure
these four stainless steel
contacts are against the
surface to be monitored.
Figure 3
Drill only in the
innermost area.
To insure proper operation, test weekly.
Concrete can be semi-conductive. If
experiencing false alarms, insulate all
probes mounted on concrete.

INTRODUCTION
Thank you for your purchase of the Winland WaterBug® model WB-200. The WB-200 is completely electronic and is designed
to detect water only (distilled and deionized water cannot be detected). The WB-200 is not a self contained warning device.
For proper operation, it must be used in conjunction with an alarm system, sounder, etc. It is designed so that the control
console mounts on a wall or other flat vertical surface and the remote probes are placed in the locations where water
leakage is most probable. Up to six remote probes may be connected to one control console. A film of moisture forming a
bridge between the two metallic contacts on any remote probe is all that is needed for the unit to signal an alarm condition.
The output on the WB-200 is non-latching, but will remain in alarm state until the moisture bridge is broken. As sensitive
as the WB-200 is, it will not alarm due to high humidity or condensation. The WB-200 is ideal for use in homes, offices,
computer rooms, warehouses, etc.
INSTALLATION
Locate the area where the WB-200 console is to be mounted. Using the WB-200 as a guide, mark the two locations on the
mounting surface where the holes will be drilled in order to use the case’s mounting flanges. If mounting on drywall, use the
two provided drywall anchors. Once the holes have been drilled, place the WB-200 against the surface and drive the screws
into the holes or anchors.
Multiple probes must be hooked up in parallel to the two “sensor” terminals. The remote surface probes may be mounted
securely to the floor or a wall. Mounting the probe(s) to a vertical surface like a wall enables you to monitor an area for rising
water levels. This is useful in basement sump pumps and other types of water storage and drainage systems.
TERMINAL BLOCK CONNECTIONS
Relay contacts are accessible on the terminal block (See
Figure 1). The WB-200 is in normal condition when
power is applied and no moisture is being detected. It’s
in alarm condition when water is detected by any one
of the remote probes.
Note: When connecting DC power to the WB-200 be
sure to observe polarity and test to see if the WB-200
is operating properly. This may be done by forming
a water bridge between two of the metallic contacts
located on the probe (See Figure 2) with a moistened
finger or cloth. If the WB-200 is not operating properly,
check the polarity of the power supply connections.
AC – Power input wires are interchangeable
DC – Positive to V+ and negative to Ground
TEST PROCEDURES
To test the WB-200 operational status, form a water bridge between the two metallic contact points (See Figure 2) with a
moistened finger or cloth. If working properly, the WB-200 will activate the warning device to which it is connected within
approximately three seconds. The WB-200 will reset automatically when the probe dries and there is no longer a water
bridge between the two metallic contact points.
WATER
WATER
WATER
WATER
VAC / +VDC
Relay Common
Relay N.O.
Relay N.C.
Ground (VAC / -VDC)
Figure 1
Figure 2
STANDARD SURFACE PROBE UNSUPERVISED
If a remote probe is to be bolted down in a permanent installation, drill
only in the innermost center recessed area (See Figure 3). Drilling anywhere
other than the innermost circle may damage the internal wiring causing the
WB-200 to fail.
MONITORING FOR THE ABSENCE OF WATER
The WB-200 can be used to monitor for the absence of water (water level).
This is done by:
1 - mounting the probe at the desired minimum waterline and ;
2 - using the opposite set of relay contacts that you would use if you were
detecting the presence of water.
ALARM NO ALARM
Four Probe Contacts
Mount the probe to ensure
these four stainless steel
contacts are against the
surface to be monitored.
Figure 3
Drill only in the
innermost area.
To insure proper operation, test weekly.
Concrete can be semi-conductive. If
experiencing false alarms, insulate all
probes mounted on concrete.

Electronic Water Detection Device
© 2012 Winland Electronics, Inc.
D-011-0116 Rev C (08/2012)
ONE YEAR LIMITED WARRANTY
Winland Electronics, Inc. (“Winland”) warrants to the end user/purchaser that each product of its manufacture shall be free from defects in material and
factory workmanship for a period of one year from the date of purchase, when properly installed and operated under normal conditions according to
Winland’s instruction. Winland’s obligation under this warranty is limited to correcting, without charge, at its factory any part or parts thereof which shall
be returned to the factory, by the original purchaser, transportation charges prepaid, within one year of the date of purchase and which upon examination,
shall disclose to Winland’s satisfaction to have been originally defective. Correction of such defects by repair to, or supplying replacements for, defective parts
shall constitute fulfillment of all Winland’s obligations to purchaser under this limited warranty. Repair service performed by Winland after one year from
date of purchase will be for a reasonable service charge. This limited warranty shall not apply to any of Winland’s products which have been subject to misuse,
negligence or accident or which have been repaired or altered outside of Winland’s factory. The warranty is void if the Product’s housing or cover is removed.
Winland shall not be liable for loss, damage or expense resulting, directly or indirectly, from the use of its products or any other cause. This warranty shall
be null and void in its entirety if: (i) the product is altered or modified in any way that is not consistent with the manufacturer’s instructions, or (ii) the
product is used with or connected to a device: (a) that such product is not intended to be used with or connected to, (b) is not otherwise consistent with the
manufacturer’s instructions, or (c) is not otherwise approved by the manufacturer. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSES, NON-INFRINGEMENT AND TITLE, AND ANY
WARRANTIES ARISING FROM COURSE OF DEALING, USAGE OF TRADE OR OTHERWISE. ALL OTHER REPRESENTATIONS MADE TO THE END USER/PURCHASER BY
ANY OTHER PARTY ARE ALSO EXCLUDED. WINLAND SHALL NOT BE LIABLE TO ANY PERSON FOR INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES
OF ANY DESCRIPTION, WHETHER ARISING OUT OF WARRANTY OR OTHER CONTRACT, NEGLIGENCE OR OTHER TORT, OR OTHERWISE. Under no circumstances
shall Winland’s liability under this limited warranty exceed the purchase price paid by the end user/purchaser for the product. No person, agent or dealer is
authorized to give warranties on behalf of Winland nor to assume for Winland any other liability in connection with any of its products.
SPECIFICATIONS
Power Requirement 8-28 VDC @ 35mA
8-28 VAC @ 100mA
Sensitivity Will not alarm due to high humidity or condensation.
Operating Temp 32˚ to 130˚F (0˚ to 54˚C); non-condensing environment (indoor use only)
Output 1 Form C Relay (N.O./N.C.)
1 Amp @ 30 VDC, resistive
1 Amp @ 24 VAC, resistive
Probe Options Includes 1 Standard Unsupervised Surface Probe (W-S-U)
Accepts up to 6 Unsupervised Surface Probes (W-S-U) wired in parallel or
Accepts up to 6 Unsupervised Under Carpet Probes (W-UC-U) wired in parallel.
Max Cable Length 1-2 probes; max recommended distance of 200’ (61 m)
3-6 probes; max recommended distance of 100’ (30.5 m)
Probe Cable Probes include 15” (4.6 m) cable. Extend using 22-18 AWG twisted pair.
Console Weight 2.4 oz (0.07 kg)
Console Dimensions 4.1 x 2.36 x 1.18” (10 x 6 x 3 cm) with flanges
Probe Dimensions Surface: 2 x 3 x 0.88” (5.1 x 7.6 x 2.2 cm)
Under Carpet: 2 x 3 x 0.18” (5.1 x 7.6 x 0.5 cm)
Mounting Flanges
Case Material ABS
Warranty 1 Year Limited
CONTENTS
This package contains:
• 1 WB-200
• 1 Surface Probe - Unsupervised (W-S-U)
• 1 Installation/Operating Instructions Guide
WB-200
ADDITIONAL PROBES
Multiple probes must be connected in parallel to the two
“sensor” terminals. The WB-200 accepts up to 6 probes
wired per console.
W-S-U
Water Probe - Surface
Unsupervised
W-UC-U
Water Probe - Under Carpet
Unsupervised
Tech Support 8:00am - 5:00pm Central Time
(800) 635-4269 • +1-507-625-7231 P
www.winland.com
WEEE Product Recovery/Recycling for EU Customers
In an effort to improve waste management in the European Union, the European Union has enacted directive 2002/96/EC on Waste Electrical and Electronic
Equipment (WEEE Directive). According to the WEEE Directive, Winland Electronics must take back waste electrical or electronic equipment covered under the
WEEE Directive, at its cost, for all product it puts on the market after July 1, 2006. The Return Process: Contact Winland via our web site at www.winland.com.
Radio Frequency Interference Requirements: This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
CE Marking and European Union Compliance: Products intended for sale within the European Union are marked with the CE Mark,
which indicates compliance to applicable Directives and European Norms (EN). Amendments to these Directives or ENs are included:
Electromagnetic Compatibility Directive 2004/108/EC; Low Voltage Directive 2006/95/EC; RoHS Directive 2002/95/EC; WEEE Directive
2002/96/EC.
Statement of Compliance: Winland Electronics, Inc. hereby declares that this device is in compliance with all the applicable Directives
2004/108/EC, 2006/95/EC, 2002/95/EC, 2002/96/EC.
Symbols on the Product or Manual Labeling
For product disposal, ensure the following:
• Do not dispose of this product as unsorted municipal waste.
• Collect this product separately.
• Use collection and return systems available to you.
WEEE Waste Electrical and Electronic Equipment
RoHS Restriction of Hazardous Substances
Table of contents
Other Winland Electronics Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Dwyer Instruments
Dwyer Instruments MS-021 Installation and operating instructions

MKS
MKS Ophir Spiricon BeamWatch Standard User notes

Keysight Technologies
Keysight Technologies M9393A Notes

FLIR
FLIR identiFINDER R200 quick start guide

KROHNE
KROHNE ALTOSONIC V Addition to the installation and operating instructions

IFM
IFM SV0527 operating instructions