TROUBLESHOOTING
Wirepath structured wire modules are designed to function trouble-free. Most problems that
occur are due to simple issues. If you have trouble, please check the list of simple xes
below. If the problem persists, contact your authorized Wirepath dealer or Wirepath customer
service at 866.424.4489.
No Video output or picture on outputs
• Power supply is connected incorrectly or plugged into an outlet that does not have power.
Check connections and verify power on the outlet. The red LED on module will be lit when
power is correctly connected.
• Verify that there is signal on any of the inputs being used.
• Check all wiring connections on output(s) with no signal including any wall-plate
connections at the remote location.
No Telephone signal
• Verify that there is signal on the input being used.
• Check all wiring connections on output(s) with no signal including any wall-plate
connections at the remote location.
• Disconnect RJ-31X cable if this option is being used. Retry operation.
INSTALLATION GUIDE
2X6 POWERED RF VIDEO COMBINED WITH 1X6 TELEPHONE SECTION
>>WP-MOD-COMBOVT
®
INTRODUCTION & FEATURES
INSTALLATION
SPECIFICATIONS
2
2/3
4
Wirepath
10405 Granite Street
Charlotte, NC 28273
704.927.7607
Tech Support: 1.866.424.4489
email: [email protected]
www.snapav.com
©2007 Snap AV • Charlotte, NC
®
Two-Year Warranty
All Wirepath®products have a two-year Limited Warranty. This
warranty includes parts and labor repairs on all components
found to be defective in material or workmanship under normal
conditions of use. This warranty shall not apply to products which
have been abused, modied or disassembled. Products to be
repaired under this warranty must be returned to the SnapAV or a
designated service center with prior notication and an assigned
return authorization number (RA).
Thank you for purchasing a great item from one of the highest value lines in structured wiring
available today, Wirepath. We appreciate your purchase and are committed to being the best
choice for your needs.
The Episode WP-MOD-COMBOVT is a superb choice for almost every basic type of home
installation. It has been designed with advanced technology components that allow high
performance while being exible enough for any type of installation. Use other Wirepath
structured wire items for your installation needs to get the best value possible in your systems.
IMPORTANT INSTRUCTIONS
• Read and understand all instructions.
• Do not use this product near water, such as a bath tub, wash bowl, sink, pool or in a wet basement.
• Never install wiring for telephones during a lightning storm.
• Never touch bare telephone wires or connections unless the main line has been disconnected at
the interface.
• Use caution when installing, terminating or modifying any type of wire.
WIREPATH COMBO VIDEO / TELEPHONE MODULE FEATURES
MULTIPLE RF INPUTS
Two 75-ohm inputs for Antenna and Cable signals. Only one input is required for proper operation.
RF AMPLIFICATION
Bi-directional amplication provides 15 dB of gain in a CATV or antenna system. 40 MHz to 1 GHz
forward bandwidth with 10 MHz to 40 MHz reverse bandwidth.
POWER SUPPLY INCLUDED
The 12 volt power supply is required for the Video amplier to work properly. You may also substitute
the Episode IR-PS power supply if needed.
TELEPHONE DISTRIBUTION FOR UP TO FOUR LINES TO SIX LOCATIONS
Maximize your exibility by using Binary™ 8 conductor CAT5e UTP cabling.
TELEPHONE EXPANSION FOR UP TO FOUR LINES TO EIGHT LOCATIONS
The Wirepath WP-MOD-TELEXP8 can be easily added to the WP-MOD-COMBOVT for expanding four
lines to up to eight additional locations.
RJ-31X JACK FOR EASY INTEGRATION WITH SECURITY SYSTEMS
This allows easy integration for security systems.
INSTALLATION
PLACING YOUR WIREPATH STRUCTURED WIRE MODULE
Wirepath structured wiring modules are designed to t Wirepath structured wiring enclosures, but also t
most major brands of enclosures as well. Installation is simple with our familiar expansion pins. Plan the
placement of each model in the enclosure based on how you have wire entering the enclosure and what
will allow for the cleanest routing of wires.
If the Wirepath module is being used in an enclosure of another brand, it may be necessary to use one
of the included spare mounting pins in the extra mounting ange hole and remove the two pins on that
side to t the mounting pattern of other enclosures from another brand.
VIDEO CABLE WIRING
Use standard F connectors for terminating the wire.
TELEPHONE WIRING
A standard 110 punch down tool is all that is required to properly connect the wiring to the module.
Please see illustration.
RJ-31X WIRING
If it is necessary to interface the telephone wiring with a security system, simply use the provided jack.
Follow the illustration below if you need to make a cable for this use.
POWER SUPPLY
Do not route the power supply wire in a way that could cause it to be pinched or cut.
Proper Connection
Do not untwist pairs
more than 1/2”
The connector is a insulation
displacement system. Use a
high quality 110 punch down
tool to push the wire into the
contacts. Use of other tools such
as screwdrivers or pliers will
result in poor performance and
may damage the connectors.
Ring Return - 1
Ring - 4
Tip - 5
Tip Return - 8
1
4
5
8
RJ-31X

Other Wirepath Control Unit manuals

Wirepath WP-MOD-TEL1x6 User manual

Wirepath

Wirepath WP-MOD-TEL1x6 User manual

Wirepath WP-MOD-RJ45-TEL1X12 User manual

Wirepath

Wirepath WP-MOD-RJ45-TEL1X12 User manual

Popular Control Unit manuals by other brands

Victaulic 867-7UF Installation, operation and maintenance manual

Victaulic

Victaulic 867-7UF Installation, operation and maintenance manual

SMC Networks SJ 1000 Series manual

SMC Networks

SMC Networks SJ 1000 Series manual

Megmeet MC100 Series user manual

Megmeet

Megmeet MC100 Series user manual

Sunshine Solar ETFE user manual

Sunshine Solar

Sunshine Solar ETFE user manual

CIAT CIATControl OPC Server Installation and operating instructions

CIAT

CIAT CIATControl OPC Server Installation and operating instructions

WEG CFW100-IODR Installation, configuration and operations guide

WEG

WEG CFW100-IODR Installation, configuration and operations guide

Velleman-Kit K8030 quick start guide

Velleman-Kit

Velleman-Kit K8030 quick start guide

Detection Systems DS7436 Installation instructions manual

Detection Systems

Detection Systems DS7436 Installation instructions manual

Vimar By-alarm 01704 quick start guide

Vimar

Vimar By-alarm 01704 quick start guide

Bray/VAAS Slurry 760 Series Operation and maintenance manual

Bray/VAAS

Bray/VAAS Slurry 760 Series Operation and maintenance manual

ACM DTM Series Installation and operating instructions

ACM

ACM DTM Series Installation and operating instructions

National Instruments NI 9242 Getting started guide

National Instruments

National Instruments NI 9242 Getting started guide

Watts BT-FR02-RF Installation and user guide

Watts

Watts BT-FR02-RF Installation and user guide

Interlogix UM-ZW installation manual

Interlogix

Interlogix UM-ZW installation manual

Allen-Bradley ArmorBlock 1732E Wiring diagrams

Allen-Bradley

Allen-Bradley ArmorBlock 1732E Wiring diagrams

Richter RSS/F Series Installation and operating manual

Richter

Richter RSS/F Series Installation and operating manual

SPX 9500 Operating & installation instructions

SPX

SPX 9500 Operating & installation instructions

AzureWave AW-CU544 Reference Design Guide

AzureWave

AzureWave AW-CU544 Reference Design Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.