manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Wirepath
  6. •
  7. Control Unit
  8. •
  9. Wirepath WP-MOD-TEL1x6 User manual

Wirepath WP-MOD-TEL1x6 User manual

This manual suits for next models

1

Other Wirepath Control Unit manuals

Wirepath WP-MOD-RJ45-TEL1X12 User manual

Wirepath

Wirepath WP-MOD-RJ45-TEL1X12 User manual

Wirepath WP-MOD-COMBOVT User manual

Wirepath

Wirepath WP-MOD-COMBOVT User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TROUBLESHOOTING
Wirepath structured wire modules are designed to function trouble-free. Most problems that
occur are due to simple issues. If you have trouble, please check the list of simple xes
below. If the problem persists, contact your authorized Wirepath dealer or Wirepath customer
service at 866.424.4489.
No Telephone signal
• Verify that there is signal on the input being used.
• Check all wiring connections on output(s) with no signal including any wall-plate
connections at the remote location.
• Disconnect RJ-31X cable if this option is being used. Retry operation.
• Check jumper wire from WP-MOD-TEL1X6 if the only trouble is with locations connected
to the WP-MOD-TELEXP8.
INSTALLATION GUIDE
TELEPHONE MODULES
>>WP-MOD-TEL1x6 / TELExP8
®
INTRODUCTION & FEATURES
INSTALLATION
SPECIFICATIONS
2
2/3
4
Wirepath
10405 Granite Street
Charlotte, NC 28273
704.927.7607
Tech Support: 1.866.424.4489
email: [email protected]
www.snapav.com
©2007 Snap AV • Charlotte, NC
®
Lifetime Warranty
All Wirepath®products have a Lifetime Limited Warranty. This
warranty includes parts and labor repairs on all components
found to be defective in material or workmanship under normal
conditions of use. This warranty shall not apply to products which
have been abused, modied or disassembled. Products to be
repaired under this warranty must be returned to the SnapAV or a
designated service center with prior notication and an assigned
return authorization number (RA).
3
44
Nylon6(Black)
Snap-onBotton
8
8
Brass platedwith nickelPlastic: Nylon Pin:
IDC
PIN: Phos-bronze plated with hard gold 15U"
Plastic:POM
RJ45JACK
1
2
RS-009 PLATE
PARTNO. MATERIAL Q'TY
1
STEEL PLATED WITHLACQUER(T=1.2MM)
R
RS-009
99-RS90-0001
2003.03.20, A1
2005/08/31
Thank you for purchasing a great item from one of the highest value lines in structured wiring
available today, Wirepath. We appreciate your purchase and are committed to being the best
choice for your needs.
The Episode WP-MOD-TEL1X6 and WP-MOD-TELEXP8 are superb choices for almost every
type of home installation. They have been designed with advanced technology components
that allow high performance while being exible enough for any type of installation. Use other
Wirepath structured wire items for your installation needs to get the best value possible in
your systems.
IMPORTANT INSTRUCTIONS
• Read and understand all instructions.
• Do not use this product near water, such as a bath tub, wash bowl, sink, pool or in a wet basement.
• Never install wiring for telephones during a lightning storm.
• Never touch bare telephone wires or connections unless the main line has been disconnected at
the interface.
• Use caution when installing, terminating or modifying any type of wire.
WIREPATH TELEPHONE MODULE FEATURES
TELEPHONE DISTRIBUTION FOR UP TO FOUR LINES TO SIx LOCATIONS
Maximize your exibility by using Binary™ 8 conductor CAT5e UTP cabling.
TELEPHONE ExPANSION FOR UP TO FOUR LINES TO EIGHT LOCATIONS
The Wirepath WP-MOD-TELEXP8 can be easily added to the WP-MOD-TEL1X6 for expanding four
lines to up to eight additional locations using a simple jumper cable.
RJ-31x JACK FOR EASY INTEGRATION WITH SECURITY SYSTEMS
This allows easy integration for security systems.
INSTALLATION
PLACING YOUR WIREPATH STRUCTURED WIRE MODULE
Wirepath structured wiring modules are designed to t Wirepath structured wiring enclosures, but also t
most major brands of enclosures as well. Installation is simple with our familiar expansion pins. Plan the
placement of each model in the enclosure based on how you have wire entering the enclosure and what
will allow for the cleanest routing of wires.
If the Wirepath module is being used in an enclosure of another brand, it may be necessary to use one
of the included spare mounting pins in the extra mounting ange hole and remove the two pins on that
side to t the mounting pattern of other enclosures from another brand.
TELEPHONE WIRING
A standard 110 punch down tool is all that is required to properly connect the wiring to the module.
Please see illustration.
RJ-31x WIRING (WP-MOD-TEL1x6 only)
If it is necessary to interface the telephone wiring with a security system, simply use the provided jack.
Follow the illustration below if you need to make a cable for this use.
ExPANSION PORT
If it is necessary to expand beyond six locations, connect the WP-MOD-TELEXP8 with an 8 conductor
jumper cable. Multiple WP-MOD-TELEXP8 modules can be daisy-chained. The limit of total units
possible will vary based on the installation.
Proper Connection
Do not untwist pairs
more than 1/2”
The connector is a insulation
displacement system. Use a
high quality 110 punch down
tool to push the wire into the
contacts. Use of other tools such
as screwdrivers or pliers will
result in poor performance and
may damage the connectors.
Ring Return - 1
Ring - 4
Tip - 5
Tip Return - 8
1
4
5
8
RJ-31X