1Safety and Agency Approvals
1.1 Legal Reference and Safety Standards
Generally, the operator of a communication system is responsible for its safe operation. Some
important points to respect are e.g.
Assessment of hazard levels at accessible locations,
Care for the proper installation and maintenance,
Measures for the safe operation, like access control and adequate staff training.
1.2 Electrical Safety
The CHAMELEON equipment must be grounded in accordance with local and national electrical
standards. Risk of bodily injury from electric shock! Failure to adhere to these instructions could result in
personal injury and/or damage to electrical components.
Each power supply unit must be switched on or off using a circuit breaker which have to be
implemented as part of the building wiring.
Each shelf and the rack must be properly grounded before power is applied by turning on the
respective circuit breaker.
1.3 ESD Protection
This product contains electrostatic sensitive devices. These devices can be damaged or effectively
destroyed by electrostatic discharge (ESD) during unpacking, installation, removal, storage, or shipment
if incorrectly handled.
Please note that discharge might go unnoticed by a user. Always take normal
static precautions when handling the equipment!
2Getting started
This chapter briefly describes how you get the CHAMELEON Encoder up and running. A more detailed
description is available in the manual and installation guide.
2.1 Registration
Before anything can be done with a new CHAMELEON Encoder, it must be registered at
https://wisiconnect.tv.
After registration, the entitlement file must be uploaded to the CHAMELEON Encoder.
2.2 Assembling in base unit
The CHAMELEON Encoder must be fitted in one of the base units that WISI provides. Following base
units will be supported:
GN50x Base unit with internal switch and controller for up to 10 modules, 3 HE
GN40x Base unit without internal switch and controller for up to 10 modules, 3 HE
GN20x Base unit without internal switch and controller, for up to 2 modules, 1 HE
GN01x Wall mount for up to 2 modules.
Depends of the base unit turn the chassis on the backside or frontside and insert the
CHAMELEON Encoder module.
Fix the module with delivered screws.