SAFETY
HAND RAIL INSTRUCTION
FOOT/LEG REST INSTRUCTION
ACCESSORIES
52520-R00
800.255.3126 | wyeastmedical.com
TOTALIFT
Instructions For Use
02Tank Holder IV Pole Storage IV Pole Placement
1. Push Top of Rail in
Toward Center of
Bed
2. Pull Black Lever
Upward
3. Lower Side Rail
1. Red Adjustment
Lever
2. Push Up and
Slide Foot Rest to
Position Length
3. Squeeze Lever and
Adjust into Position
Stretcher
3 Positions
• Brake
• Free
• Steer
To adjust seat
position, squeeze red
handle and hold while
positioning chair
Release red handles
when chair is in
desired position
Chair
Lateral Transfer

1
12
2
3
3
4
Lower Leg Rest
To lowest position before
lowering back rest
Figure 1
Figure 2
Squeeze handle to release leg-
rest then push down
CORRECT TRANSFER INCORRECT TRANSFER
Store Crank Handle
Whenever not in use
TOTALIFT QUICK REFERENCE GUIDE
READ USERS MANUAL BEFORE OPERATING
Adjusting TOTALIFT From Chair to Stretcher Position:
Adjust leg rest to lowest position. Lower back rest to horizontal
by squeezing handle located at head and pushing down. Lower
siderails and position TOTALIFT next to bed.
Moving patient from TOTALIFT to bed
Moving patient from bed to TOTALIFT
Adjusting TOTALIFT From Chair to Stretcher Position:
Adjust leg rest to lowest position. Lower back rest to horizontal
by squeezing handle located at head and pushing down. Lower
siderails and position TOTALIFT next to bed.
Positioning For Transfer To Bed:
Raise TOTALIFT to 2 or 3 inches above bed mattress. Pull out
crank handle (swings out from under seat section) on the side
nearest operator. (Figure 2) Opposite crank handle must be
stored away. Push TOTALIFT against the bed and SET BRAKE
Transferring Patient from Bed:
Using crank, extend transfer pad 2 to 3 inches over bed and
lower TOTALIFT until pad rests on bed mattress. (Be sure that
TOTALIFT and bed are at the same height – Figure 3.) Roll patient
onto side with draw sheet. Continue to advance the transfer pad
against the patient’s back. (Figure 4)
Tuck leading edge of transfer pad under patient, then allow
patient to roll onto pad. Adjust patient to center of pad with draw
sheet. With crank handle, retract patient and pad to center of
TOTALIFT. and release brake.
Adjust TOTALIFT for Comfort/Transport:
Raise TOTALIFT to clear bed. SET BRAKE. Adjust to desired
height. You may transport in stretcher position. Lower TOTALIFT
before adjusting back to chair position. Adjust foot rest, leg rest,
and safety belts as needed.
Position For Transfer To Bed:
Raise TOTALIFT to 2 or 3 inches above bed mattress. Pull out
crank handle (swings out from under seat section) on the side
nearest operator. (Figure 2) Opposite crank handle must be
stored away. Push TOTALIFT against the bed and SET BRAKE
Transferring Patient To Bed:
Using crank, extend patient on transfer pad 3 to 4 inches
across bed mattress. Lower TOTALIFT until pad rests on
bed mattress and finish extending pad to middle of bed
(Figure 3). Adjust patient onto bed with drawsheet. Retract
transfer pad back into TOTALIFT and release brake. Pull
TOTALIFT away from bed. Store crank handle and TOTALIFT
is ready for your next patient.
IMPORTANT
Figure 3 Figure 4

5-01031-00 R02 AN 180201
OPERATOR'S
MANUAL
TOTALIFT - II
LATERAL TRANSFER / TRANSPORT CHAIR
Model No. 90600

TOTALIFT-II OPERATOR'S MANUAL

TOTALIFT-II OPERATOR'S MANUAL
WARRANTY
Wy’East Medical Corporation warrants to the original user that the TotaLift-II Transfer-Transport Chair manufactured by
the company is free from defects in material and workmanship under normal use and service. The term of warranty
from the date of purchase/shipment is two (2) years during which Wy’East will provide to the user replacement
components or repaired components with the exception of the hydraulic pump/cylinder and gas springs, which are
warranted for one (1) year, and the mattresses, which are warranted for ninety (90) days.
In order to initiate a warranty claim the original user must provide prompt notice to Wy’East Medical Corporation within
the applicable warranty period specifying the nature of the claim. Wy’East will issue instructions as to the procedure to
follow. Wy’East reserves the right to confirm the existence of any claimed defect and to determine whether any damage
was caused by neglect, misuse, unauthorized alteration or failure to follow maintenance instructions. With respect to a
claim covered by this warranty, the defective part will be replaced or repaired at no charge, provided the defective part
is returned to Wy’East Medical. The user has the responsibility for shipping charges and installation. Assistance is
available by calling (503) 657-3101 in Oregon. This is the exclusive remedy for a claim under this warranty and in no
event shall Wy’East be liable for consequential damages. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED.
PLEASE
Read this entire manual before operating
the TotaLift-II Transfer-Transport Chair.
This warranty applies to the Wy’East TotaLift-II Transfer-Transport Chair only.
For questions or information regarding other Wy’East products, contact:
Wy’East Medical Corporation
P.O. Box 1625
Clackamas, Oregon, USA
Telephone: (503) 657-3101
(800) 255-3126
FAX: (503) 657-6901
www.wyeastmed.com
contact@wyeastmed.com

TOTALIFT-II OPERATOR'S MANUAL
PAGE 1
TABLE OF CONTENTS
This manual provides maintenance and service information for the TotaLift-II Lateral Transfer / Transport Chair. If
replacement parts are required, contact WY’EAST MEDICAL with the serial number of your TotaLift-II to ensure the
accuracy of replacement parts.
Consistent with our policy of continuing product improvement, WY’EAST MEDICAL reserves the
right to change these specifications without notice or obligation.
DESCRIPTION PAGE NO.
Warranty Inside Front Cover
Introduction, Definitions 2
Features 3
Operating Instructions 4
Procedures 10
Factory Assistance 13
Specifications 14
Periodic Maintenance 15
Notes 16
Contact Information Back Cover

TOTALIFT-II OPERATOR'S MANUAL
PAGE 2
INTRODUCTION
HOW TO USE THIS MANUAL
This manual is designed to familiarize you with the operation of the TotaLift-II Lateral Transfer / Transport Chair.
Read it thoroughly before using or servicing the equipment. Keep the manual for future reference and for new members
of your staff.
DO NOT ATTEMPT TO USE EQUIPMENT WITHOUT UNDERSTANDING THIS MANUAL
To ensure safe operation, read carefully the entire manual, before installing, operating, or servicing this equipment.
If anything is not completely understood, please contact your supplier for more details. Failure to comply with warnings
in this manual may result in injury.
Keep this manual with the TotaLift-II and refer to it as required. Contents of this manual are subjected to change without
prior notice to users.
DEFINITIONS
The words WARNING, CAUTION, and NOTE carry specific meanings and should be carefully reviewed.
WARNING: The personal safety of the patient or user may be involved. Disregarding this information could result in
injury to the patient or user.
CAUTION: These instructions point out special procedures or precautions that must be followed to avoid damaging the
TotaLift II.
NOTE: This provides special information to make maintenance easier or important instructions more clear.
MEANING OF SYMBOLS
Caution
Locked motion lockout control
Consult instructions for use
Unlocked motion lockout control
Manufacturer’s catalog number
Do not step on surface
Manufacturer’s serial number Side rail
Manufacturer Trendelenburg patient position
Date of manufacture Maximum patient weight
Safe working load

TOTALIFT-II OPERATOR'S MANUAL
PAGE 3
FEATURES
Your TotaLift-II is designed for a wide range of uses, and therefore has a variety of functions.
Surface to surface transfer of patients to and from beds and radiology or therapy tables.
Transporting patients between departments in chair or stretcher position.
Easy access for wheelchair or ambulatory patients (lower position with side rail tucked away).
Total adjustability for convenience, transport and treatment.
Sturdy dependability in code situations (quick Trendelenburg positioning).
Your TotaLift-II is intended for use in intensive/critical care, acute care, long-term care and outpatient care. It is not
recommended for use in a shower.
Prior to using the TotaLift-II for transfer, transport or any other procedure the patient must be assessed by a
qualified professional to determine the suitability of using the TotaLift-II with that patient.

TOTALIFT-II OPERATOR'S MANUAL
PAGE 4
OPERATING INSTRUCTIONS
LATERAL PATIENT TRANSFER SYSTEM
To use the Lateral Patient Transfer System, pull out the
crank handle which swings out from under the seat or
middle section.
WARNING
Only one crank handle can be out at a time and, when not
in use, must be stored under the seat, to avoid damage or
injury.
OXYGEN TANK HOLDER
To insert an oxygen tank, lift the black lid with bottom
of tank and slide into place. Then tighten knob to secure.
CENTRAL BRAKE / STEER
Red and green pedals are positioned at both sides and at
the head end of the base. When the Red pedal is down,
the brakes are set. When the pedals are horizontal, Free
Steer mode is activated, and all four wheels are completely
free for movement. When the Green pedals are down,
Tracking mode is activated, and the front right wheel is
locked in position for steering.

TOTALIFT-II OPERATOR'S MANUAL
PAGE 5
OPERATING INSTRUCTIONS
HYDRAULIC FOOT CONTROL
To raise the chair, step on the long end or head end,
of the foot control. To lower the chair, step on the
short end, or tail end, of the foot control.
ADJUSTABLE BACKREST
Squeeze lever located at the head end of chair to
position the back to any point between upright,
flat or Trendelenburg.
ADJUSTABLE FOOTREST
The footrest folds flat when not in use.
To adjust the length of the footrest, lift the center
Red lever and adjust to desired length.
WARNING
As with a wheelchair, do not allow the
patient to stand on the footrest.

TOTALIFT-II OPERATOR'S MANUAL
PAGE 6
OPERATING INSTRUCTIONS
ADJUSTABLE LEG REST
Squeeze the lever located at the side of the leg
rest, and push down or lift up to the desired position.
SIDE RAILS
To raise the side rail, just lift it to the raised position, it will
automatically lock into place. To lower the side rail, push it
towards the middle of the chair, and lift the black release
handle. Then, lower the side rail until it locks into it's
lowered position.
BLACK PUSH BAR
The black push bar provides convenient grip for
transporting the TotaLift-II when in the chair position.

TOTALIFT-II OPERATOR'S MANUAL
PAGE 7
OPERATING INSTRUCTIONS
IV POLE
The IV pole can be found in the back cover, in the IV pole
storage location. To use the IV pole, simply insert the IV
pole into the holder at the edge of the seat section, and
adjust to required height.
TRENDELENBURG
The TotaLift-II can be placed into the Trendelenburg
position at any height. To activate Trendelenburg, squeeze
lever located at the head end of chair and push down.
When Trendelenburg is activated, simply release the
squeeze lever. To return from trendelenburg, squeeze the
lever and let the chair return to the bed position.
SAFTY STRAPS
Large, quick locking and unlocking buckles make securing
a patient easy.
20 LB
9 KG

TOTALIFT-II OPERATOR'S MANUAL
PAGE 8
OPERATING INSTRUCTIONS
OPTIONAL EQUIPMENT
UPPER SIDE RAILS
The upper side rails lower by lifting the black tabs, and
pushing down. Lower the side rail until it locks into the
tucked away position. To raise side rail, simply lift into
the upright position.
Part No. 5-00990-00
HEAD REST
The headrest can be adjusted for height and
patient comfort. To attach the headrest, insert
long strap through the metal loop on the upper
portion of the back rest. Use the Velcro strip to
adjust the headrest for height and comfort.
Part No. 51084
PATIENT TRAY
The patient tray attaches to the right side of the chair, to
the holder at the edge of the seat section. Position to
desired location, and tighten knob.
NOTE
The patient tray can be stored on the left side of
the chair in the storage position.
Part No. 5-01023-00
20 LB
9 KG

TOTALIFT-II OPERATOR'S MANUAL
PAGE 9
OPERATING INSTRUCTIONS
OPTIONAL EQUIPMENT
STIRRUPS
The stirrups are fully adjustable in length and width
for both the procedure being performed and the
patient's comfort. Loosen the knob, and adjust to
desired position, then tighten knob.
Part No. 51069
THE RISK OF SIDE RAIL ENTRAPMENT
Contact Wy’East Medical before using this equipment if you are unable to understand the Side Rail Entrapment
information below. Failure to comply with this information can result in serious patient injury or death.
The term "Side Rail Entrapment" describes an event in which a patient in the TotaLift-II is entangled or trapped in the
space in or about a side rail, mattress, or mattress support platform.
The risk of entrapment can be increased with patient conditions such as restlessness, seizure disorders (uncontrolled
body movements), dementia, mental deterioration or sleeping problems. Small body size and Pediatric patients may
also increase the risk of entrapment.
The side rails are intended to prevent a patient from inadvertently moving out of the TotaLift-II, provide a sense of
security and assistance to a patient for repositioning. The side rails are never to be used to restrain an uncooperative
patient or to prevent a patient from exiting the TotaLift-II as they wish. The risk of entrapment is significantly increased
if side rails are used as a means of patient restraint.
The TotaLift-II side rails are intended to be used in pairs. Both the left and right side rail must be in the up and locked
position when in use except when transferring a patient to or from the TotaLift-II. Use of only one side rail can increase
the risk of entrapment.
The side rails should not be used for moving the TotaLift-II as they could become deformed or otherwise damaged if
excessive force is applied to them. Deformed or damaged side rails should not be used due to the possibility of
increased gaps that can increase the risk of entrapment.
Accessories are available that reduce the openings in existing side rails that could cause entrapment. Prior to using any
such accessories the patient must be assessed by a qualified professional to determine the suitability of using that
accessory. Refer to the Hospital Bed Safety Workgroup’s “A Guide for Modifying Bed Systems and Using Accessories to
Reduce Risk of Entrapment” found at http://www.fda.gov for more information on this subject.
The TotaLift-II is designed solely for use with Wy’East Medical accessories and mattresses. Accessories and mattresses
designed by other manufacturers may have variations in construction that have not been tested by Wy’East Medical and
may significantly increase the risk of patient entrapment.

TOTALIFT-II OPERATOR'S MANUAL
PAGE 10
PROCEDURES
TO TRANSFER A PATIENT FROM A BED TO THE TOTALIFT-II
Lower back rest (see Adjustable Backrest, pg 5)
and side rails (see Side Rails, pg 6) to lowest
position. Position the TotaLift-II next to the bed,
set the brake (see Central Brake / Steer, pg 4),
and raise the litter top to 2 or 3 inches above
the patient's bed (see Hydraulic Foot Control,
pg 5). Using the crank handle (see Lateral
Patient Transfer System, pg 4) extend the
transfer pad 2 to 3 inches over the bed.
Lower the litter top until it rests on patient's
bed. To prepare the patient for transfer, roll
the patient onto their side using a draw sheet,
slip sheet, or slide sheet. Continue to extend
the transfer pad until it either comes in contact
with the patient's back or reaches the red line
printed on the litter top of the TotaLift-II. Tuck
the leading edge of the transfer pad under the
patient and allow the patient to roll backward
onto the transfer pad.
With the draw sheet, slip sheet, or slide sheet,
adjust the patient to the center of the transfer
pad. Using the crank handle, retract the patient
and the pad to the center of the TotaLift-II.
Store away crank handle and lift the side rails
and into upright position. Then adjust the
TotaLift-II for patient's comfort and
transportation (see to Adjust the TotaLift-II for
Comfort or Transport, pg 12).

TOTALIFT-II OPERATOR'S MANUAL
PAGE 11
PROCEDURES
TO TRANSFER A PATIENT FROM THE TOTALIFT II TO A BED
Lower back rest (see Adjustable Backrest, pg 5),
slowly for patient's comfort, and side rails (see
Side Rails, pg 6) to lowest position. Position the
TotaLift-II and patient next to the bed, set the
brake (see Central Brake / Steer, pg 4) and raise
the top to 2 or 3 inches above the bed (see
Hydraulic Foot Control, pg 5).
WARNING
Remove Safety Straps (see Safety Straps, pg7)
from patient before transferring.
Using the crank handle (see Lateral Patient
Transfer System, pg 4) extend the transfer pad
and patient 2 to 3 inches over the bed. Lower
the litter top until it rests on bed. Continue to
extend the transfer pad until it the red line
printed on the litter top of the TotaLift-II.
With a draw sheet, slip sheet, or slide sheet,
adjust the patient to the edge of the transfer
pad, then roll the patient off of the transfer
pad, and onto the bed onto his/her side. Using
the crank handle, retract the transfer pad to the
center of the TotaLift-II. Store away crank
handle and lift the side rails and adjustable
backrest into upright position for transportation
and storage.

TOTALIFT-II OPERATOR'S MANUAL
PAGE 12
PROCEDURES
TO ADJUST THE TOTALIFT II FOR COMFORT OR TRANSPORT
Make sure to have crank handles stored away, and side rails in upright position, then release brake and pull the TotaLift-
II away from bed or any other obstructions. Adjust the foot rest (see Adjustable Foot Rest, pg 5), leg rest (see Adjustable
Leg Rest, pg 6), and back rest (see Adjustable Back Rest, pg 5), for patients comfort. Do not transport patient in the
highest position, lower the TotaLift-II (see Hydraulic Foot Control, pg 5) for transportation. Secure patient with safety
straps, and adjust for snug fit. Place the IV pole (see IV Pole) or oxygen tank (see Oxygen Tank Holder, pg 4) at this time,
if necessary. Trendelenburg can also be activated if necessary (see Trendelenburg, pg 7). Set the chair to Free Steer or
Tracking modes (see Central Brake / Steer, pg 4) for transportation. Then use Black Push Bar (see Black Push Bar, pg 6) to
push and navigate the TotaLift-II, much like a wheel chair.
SAFETY CONSIDERATIONS FOR ALL PROCEDURES
Prior to using the TotaLift-II for transfer, transport or any other procedure the patient must be assessed by a qualified
professional to determine the suitability of using the TotaLift-II with that patient.
When transporting or leaving the patient unattended in the TotaLift-II adjust it to the lowest position.
When routing cables or tubing from the patient or other equipment care must be taken not to squeeze or otherwise
impair them between parts of the TotaLift-II.
When using a mobile hoist in conjunction with the TotaLift-II be sure it fits properly with the undercarriage and that it
can be used according to the manufacturer’s instructions.

TOTALIFT-II OPERATOR'S MANUAL
PAGE 13
FACTORY ASSISTANCE
REPLACEMENT ITEMS
WARNING
Incompatible mattresses can create hazards. Use only replacement mattresses specified by Wy'East Medical.
To order replacement parts, contact Wy’East Medical customer service or your Wy’East Medical representative.
Include the following information with your request:
1. Serial and Model numbers of your TotaLift-II,
2. Purchase date, if available.
3. Part number and description of the replacement part needed (see Technical Service Manual).
4. Shipping and billing instructions, including complete address.
RETURNING ITEMS
To return parts or goods, contact Wy’East Medical for authorization.
Contact information:
Telephone: (503) 657-3101
Toll Free: (800) 255-3126
Fax: (503) 657-6901
Email: admin@wyestmed.com
WARNING
No unauthorized modification of this equipment is allowed. Contact Wy’East Medical prior to any modification of this
equipment.

TOTALIFT-II OPERATOR'S MANUAL
PAGE 14
SPECIFICATIONS
ENVIRONMENTAL CONDITIONS FOR SHIPMENT AND STORAGE FOR USE
Temperature -40°F to 158°F (-40°C to 70°C) 50°F to 104°F (10°C to 40°C) ambient
Relative Humidity 10% to 95% non-condensing 20% to 95% non-condensing
Atmospheric Pressure 50 kPa to 106 kPa 70 kPa to 106 kPa
Maximum Height
36.5 in
93.0 mm
Minimum Height
21.0 in
53.5 mm
Maximum Length
71.5 in
181.5 mm
Maximum Width (Side-Rails Up)
27.0 in
68.5 mm
Maximum Width (Side-Rails Down)
24.5 in
62.0 mm
Mattress Length
70.0 in
178.0 mm
Mattress Width
23.0 in
58.5 mm
Mattress Height
2.0 - 3.0 in
5.0 - 7.5 mm
Foot Rest Adjustment
6.5 in
16.5 mm
Side-Rail Length
24.0 in
61.0 mm
Side-Rail Height
12.0 in
30.5 mm
Side-Rail Width
25.0 in
63.5 mm
Wheelbase Length
32.5 in
82.5 mm
Wheelbase Width
20.0 in
51.0 mm
Back-Frame Travel
80.0 deg
80.0 deg
Leg-Frame Travel
61.0 deg
61.0 deg
Transfer Travel
20.0 in
51.0 in
Maximum Patient Weight
Safe Working Load 400 lbs 181 kg

TOTALIFT-II OPERATOR'S MANUAL
PAGE 15
PERIODIC MAINTENANCE
The following scheduled maintenance and inspections will help to ensure trouble-free
operation of your TotaLift-II Transfer-Transport Chair
Not recommended for use in shower.
Do not pressure-wash the unit.
ONCE A MONTH
Check for loose or missing snap rings.
Check for loose or missing nuts and bolts.
Clean Unit – Wipe off dust.
TWICE A YEAR
Lubricate the area where the crank handle turns against the lockout surface with bearing grease.
Apply a light coating of paste wax or Armor-all to the litter-top to reduce friction with the glide.
Raise the chair to its max height and wipe the cylinder rod of the pump clean, apply light coating of oil to the
cylinder rod.
Lubricate the transfer gear mechanism with bearing grease.
Check drive belts to ensure they are centered on drive rollers.
Tighten up drive belts on rollers.
Lubricate pins with Permatex Super Lube or equivalent.
Wipe and clean gas spring cylinder on trendelenburg assembly, apply light coat of oil.
Apply a small amount of light oil to footrest release mechanism and extension rods.
EVERY TWO YEARS
Replace mattress with a new mattress.
Replace safety straps if equipped.
Replace head rest if equipped.
This manual suits for next models
1
Table of contents
Other WY'EAST MEDICAL Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Interactive Metronome
Interactive Metronome Portable Pro Unit Setup instructions

Nasco
Nasco Life/form KERi LF04024U instruction manual

Stryker
Stryker 5050 Operation manual

AREX
AREX CHIROBLOC CBM INSTRUCTION FOR USE AND STERILIZATION

Rhythm Healthcare
Rhythm Healthcare P2 Getting started guide

aidapt
aidapt VP100C Fixing and maintenance instructions