externalvoltage of2.5Visapplied,corresponding resistancevalues atdifferent
temperatures areshowninTable1
Table1The inspecting temperatureand resistance corresponding tableofPTCheat
detector
Resistance of3PTCheatdetecting
elementsconnectedwitheachother
inseries (Ω) ≤300 ≤1650 ≥3990 ≥12000
Temperatureinthe corresponding
winding (℃) 25 115 125 ≥135
4.3.2 Connectionof thebrake electromagnet connection box
●The electromagneticcoilinthe brake electromagnetshouldbe connected withDC
voltage.Whenthe brake isrequired torelease,quickresponse excitation voltage of
DC200±10Vshouldbe electrified until the power supplyisswitched off.
●Forthe connection ofthe brake,itisnecessarytouse 2-corecablewithits
cross-section ≥0.75mm2and itsinsulating withstand voltage≥500V
●The connectionterminalsofelectromagneticcoil and2micro-switches areinside the
connectionbox,and thereshouldbe no dust, humidityand othersobjectsinside the
connectionbox duringconnecting(see picture3).
●The connection terminalofbrakingmicro-switch shouldbe connected in
normally-closed state, namelywhen the brakeisinbraking state(the electromagnetic
coilisde-energized), the twogroupsswitchcontactsareinclosed state,and when the
electromagneticcoil ofthebrake isenergized (the brake isreleased), the twogroups
switch contactsofthe braking micro-switch areinopen state
●The currentis0.3Awhenthe excitationvoltageforbraking electromagneticcoilis
DC200V.
●Forthe interrupting capacityofmicro-switch,the voltagedoes notexceed AC250V,
current doesnot exceed 0.5A
●The actuation position ofthe braking micro-switch can be implementedbythe
adjustingbolt ofbrake switch.
4.3.3 Encoderconnection
●Beforethe encoderisconnected ordisconnected withthe frequencyconverter,power
supplied tothe frequencyconverter must be turned offinorder toavoidany damages
tothe inverter and encoder.
●WYJ140 series traction machinesmaybe provided withawiderange ofoptional
encodersso thatcan selectdifferent inverters.Onordering,usersshouldselect
corresponding encoderaccording tothe usedfrequencyconverter,orselectthe
frequencyconverteraccordingtothe used encoder.Ifusersfeeldifficulttodetermine
it, theyshouldconsult the manufacturer ofthe frequencyconverter.
●The standardlengthofthesignalcableofencoderis10m.It alsocan be provided as
per users’requirements, but the max lengthcannot exceed10m
●Inordertopreventthe interferetothesignalcableofencoderfromthe cableof
traction machine,the powersupplycableoftraction machines andsignalcableof
encodersshouldbe laidseparately.
5Commissioningof traction machine
●Commissioning oftractionmachine isactuallytoensureoptimumadaptation between
frequencyconverterandtraction machine.Thereforeitisnecessarytohaveagood
understandingand abundantexperiences tothe frequencyconverterin
commissioning and use