XPR Access WS4 Instruction manual

4 Door access control unit with web access
EN
QUICK USER GUIDE
WS4 is a 4 door control unit designed to operate with readers with RS485 output.
There is no need to install any software. There is no need to have a dedicated PC
either. Everything is available online and the operators just need to register with
controller’s serial number to start using the software application.
Capacity: 2500 Users
Events: 50000 max.
Doors: 4 (max. 20 doors in same network)
Readers: 4
Door contact inputs: 4
Push button inputs: 4
Auxiliary Inputs: 2 (emergency, vehicle detection)
Auxiliary Outputs: 2 (alarm, storing alarm status, presence)
Power supply: 120 to 240 V AC, 100 VA-1.52A with fuse (1 A)
Supply for the readers: 225 mA each max.
Supply for the locks: 600 mA each max.
Relay characteristics: 2A/48 VAC/DC#
Processor: ARM A5 - 528 Mhz
Memory: 64 MB Ram DDR2 133 Mhz
TCP/IP connection: 10/100/1000 Base-T – HTTP or HTTPS
Housing dimensions: 350 x 250 x 80 mm
Operating temperature: 0 °C to +50 °C
Humidity: 0% to 85% (non-condensing)
Tamper: Yes
Wiegand readers connection: Yes, via Wiegand to RS485 converter - WS4-CNV
Elevator feature: Yes, 2 elevators per installation, each - 24 floors
Interlock, Anti pass back, people counter, presence, system logs, reports in CSV
FIRST CONNECTION AND CONFIGURATION
The WS4 does not have default IP address. By default is set to DHCP. There are 2
methods to connect to and configure WS4 - LAN and Standalone method.
If you can not connect, it is because your network does not recognize the name of the
WS4 controller. In this case, go to our web site http://www.xprgroup.com/products/ws4/
and download the tool called “Device Finder”.
The “Device Finder” will enable you to find out the IP address of the WS4 controller.
Run the “Device Finder” and you will get a list of all the WS4 controllers connected in
your network, including their IP addresses, just like the picture below.
1. Put the DIP switch 1 in position OFF.
2. Connect a cable from your network to the ethernet connector of Ws4.
3. Open a web browser and enter http://ws4 followed dash and the serial number of
the WS4 controller
METHOD 1 (For use in a home or business LAN network)
Open a browser and type the IP of the WS4 controller and you will be prompted to the
login page.
User Name: admin
Password: WS4 followed by Dash and the Serial Number (ex. WS4-110034) just like the
image below, all in capital letters without space.
WS4-110034
In this configuration, the network’s DHCP server will assign an IP address to your WS4
METHOD 2 (For standalone use - without LAN network)
In this configuration, the WS4 will assign an IP address to your PC. The PC must be set to obtain IP
address automatically.
Serial number
DIP Switch
pos. 1
1
2
3
1. Put the DIP switch 1 in position ON.
2. Connect a cable from your PC directly to the ethernet connector of WS4.
3. Open a web browser and enter the following IP - 192.168.50.100, then put the login
credentials like explained above
192.168.50.100
FACTORY RESET
DIP Switch 4 allows to log into the system as an administrator if
login or password is forgotten. Toggle this dip switch ON for about
15 seconds, then back to OFF. The system will then allow, for 5
minutes, to connect (from the local network only) with the default
login and password.
DIP Switch 4 allows a complete re-initialization of the system. To
do this, switch this dip switch 3 times OFF - ON - OFF within 10
seconds.
ON
1
2
3
4
OFF
Factory reset
CHANGE PASSWORD
ON
1
2
3
4
OFF
Change
password
SOFTWARE SETTINGS
Go to “Doors”, select the reader(fig.2) and then select the type of the reader in the
field ”Card”. (fig.3). While off line, red LED blinks fast and buzzer beeps continuously.
Once communication is established, the red LED and the buzzer stop. Green LED
starts to blink continuously. If you want to stop the green LED, go to Settings/System
Options and select for the backlight ON or OFF (not default) fig.4
fig. 1
fig. 3
ADDING READERS
Go to Users (fig.1), select “New”(fig.2) and then fill the form (Name, category, card
number...)(fig.3).
ADDING USERS
fig. 1
fig. 2
WS4 system can manage up to 10 WS4 boards in the same installation (with up to 20
doors, whether single or double). One WS4 must be master, the others must be
slaves. The master/slave selection is made with Dip-switch 2: OFF - Master (factory
setting), ON - Slave.
Go to “Doors” and click on the link “Add slave”(fig.1). Enter the serial number of the
WS4 to be added and click Search. If it finds it, the system directly adds this slave
into the installation and you can configure its doors (fig.2).
In case of error, a message is displayed in red.
ADDING SLAVE CONTROLLERS
To add 2 readers on 1 Door, select the reader (fig.2) and there, for “Type of Access”
select “Access with 2 readers” (fig 5). Fill the form for both readers and they will
merge in one door (fig. 6)
fig. 5
ON
1
2
3
4
OFF
Master/
Slave
Switch
DIP switch 2
OFF
Master
DIP switch 2
ON
Slave 1
DIP switch 2
ON
Slave 9
fig. 1
fig. 2
fig. 4
1
WS4
DESCRIPTION
SPECIFICATIONS
fig. 2
fig. 3
fig. 6
v.a1
Example of a door with 2 readers + electric strike fail close
Door contact
OUT
Address 0
Power supply 14,2V
Push button
Push button
Door contact
Electromagnetic Lock 12V/600mA max
Box Tamper
Network
IN
Address 1
Reader
Address 0
Address 1
12V/600mA max
12V/600mA max
electric strike (fail close)
Reader
See user manual
A
B
B
B
A
A
www.xprgroup.com
V+
V- +
-
2
Connection example of 3 doors
1. The readers for Doors 1.0 and 2.0 must be at address 0 and
those for Doors 1.1 and 2.1 at address 1.
2. For doors equipped with 2 readers, one must be at address
0 and the other at address 1.
3. The function of OUT1 and OUT2 can be configured in the
software
4. In1 & In2: Connect to GND by a volt-free contact to activate
the input
5. LIYCY cable, twisted pair, up to 80m.
If more than 80 m. are needed, then termination resistors(120
ohm) may be required at both ends of the RS485 line, while
taking into consideration the lengths proposed on our web
site.
6. Alarm cable 2x0,22
7. The cross section of the cable depends on the current
needed by the lock
Note: The elevators relay boards (WS4-RB-12) are connected
on the same Rs485 lines as the readers.
4
6
7
55
33
6
7
6
5
5
7
6
2 2
1
1
12V battery
Example of a door with 1 reader + electric strike fail open
Example of a door with 1 reader + electromagnetic lock
electric strike (fail open)
Emergency
button
Alarm siren
or
flash siren
This product herewith complies with requirements of EMC directive 2014/30/EU.
In addition it complies with RoHS2 directive EN50581:2012

Other XPR Access Control Unit manuals

XPR Access SC24000 User manual

XPR Access

XPR Access SC24000 User manual

XPR Access EWS-DR User guide

XPR Access

XPR Access EWS-DR User guide

Popular Control Unit manuals by other brands

Siemens SIMADYN D T400 Brief description

Siemens

Siemens SIMADYN D T400 Brief description

Banner ES-TN-1H Series manual

Banner

Banner ES-TN-1H Series manual

Novoferm TA MS 400V / 230V Mounting and operating instructions

Novoferm

Novoferm TA MS 400V / 230V Mounting and operating instructions

enviro-tech ET3-M quick start guide

enviro-tech

enviro-tech ET3-M quick start guide

Moen 8310S35 installation guide

Moen

Moen 8310S35 installation guide

oventrop AV9 operating instructions

oventrop

oventrop AV9 operating instructions

Festo CPI-CL Series manual

Festo

Festo CPI-CL Series manual

Coreline Fig.223 Wafer Installation, operation & maintenance manual

Coreline

Coreline Fig.223 Wafer Installation, operation & maintenance manual

Siemens CM 1542-5 operating instructions

Siemens

Siemens CM 1542-5 operating instructions

GSK 980TC3 Series manual

GSK

GSK 980TC3 Series manual

Burkert 0142 operating instructions

Burkert

Burkert 0142 operating instructions

ProSoft Technology inRax MVI56E-GSC quick start guide

ProSoft Technology

ProSoft Technology inRax MVI56E-GSC quick start guide

Vingtor Stentofon EAM-200 quick start guide

Vingtor Stentofon

Vingtor Stentofon EAM-200 quick start guide

Winsen MH-Z19B user manual

Winsen

Winsen MH-Z19B user manual

Warner Electric CBC-700-90 installation instructions

Warner Electric

Warner Electric CBC-700-90 installation instructions

Banner ES-TA-3F1 operating instructions

Banner

Banner ES-TA-3F1 operating instructions

ATIM ACW-RPI user guide

ATIM

ATIM ACW-RPI user guide

SCHUNK KEH-P Assembly and operating manual

SCHUNK

SCHUNK KEH-P Assembly and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.