XPR Access SC24000 User manual

www.xprgroup.com 1
2 Door standalone access control unit
EN
SC24000
CONTENTS:
1. FEATURES
1. Features .................................................................................................. 1
2.Mounting .................................................................................................. 2
3.Typical two door application .......................................................................2
4.Terminal block description ....................................................................... 3
5. DIP switch settings .................................................................................... 3
6. Wiring ................................................................................................. 4
7. Factory reset .................................................................................... 4
8. Programming .................................................................................... 5
9. Anti Pass Back .................................................................................... 7
10. Examples ................................................................................................. 8
11. Programming with Keypad (LCSP, VKP, INOX, MTPADM) ............. ... 8
12. Programming in double security mode (LCSP) ........................................... 9
• Programmable trough readers
• 4000 users (Cards)
• 2 reader inputs (Auto detect Wiegand26 / Wiegand34)
• 2 door relays (2 x 250VAC/4A)
• 2 door sensor inputs
• 2 push button inputs
• 2 Alarm relays: Output 1 (door forced alarm), Output 2
(door left open alarm)
• Programming done with Master1&2, Delete, Reset APB,
Master 1 and Master 2 card
• Adjustable Door relay time (1 - 250sec, or ON/OFF(toggle)
mode)
• Anti Pass Back option
• Normal wiegand mode (card only) and LCSP mode (card and
PIN code) on any reader
• Shadow delete card - per user or per group of users
• Max. Users in 1 groups: 4000 (each group has 1 card)
• Single door mode / 2 readers (one reader on each side of the
door)
• 2 door mode / 2 readers (one reader on each door)
• 60 sec lockout after 15 invalid cards
• Enroll sequential block of cards - max. block of 100 cards
Electrical Characteristics
Operating Voltage: 8 to 15V DC
Current consumption : max. 180 mA (without readers)
Door Relays: 250 VAC/4A
Output Relays: 250 VAC/4A
Environmental Characteristics
Operating Temperatures : 0ºC to +50ºC
Operating Humidity : 0 to 95% (non-condensing)
PCB Dimensions (mm) 102 L x 86 W
90 mm
107 mm
61 mm
v.b2

www.xprgroup.com 2
2. MOUNTING
3. TYPICAL TWO DOOR APPLICATION
On wall
On DIN Rail
Rear view
74,35mm
74,35mm

www.xprgroup.com 3
4. TERMINAL BLOCK DESCRIPTION
5. DIP SWITCH SETTINGS
led’s
power supply
wiegand
led’s
power supply
wiegand
(NC)
(NO)
(NC)
(NO)
Led Green -
Led Red -
GND
12 VDC
Data0
Data1
12 VDC
GND
12 VDC
GND
Led Green -
Led Red -
GND
12 VDC
Data0
Data1
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
Door Sensor 1
GND
Push Button 1
Door Sensor 2
GND
Push Button 2
Reader 1 Power Supply
Reader 2
Door 1 Relay
Door Left Open Alarm
Forced Door Alarm
Door 2 Relay
Door Sensors
Exit Buttons
Alarm Outputs
Output 1 (door left open alarm)
- ON if any door is left open by the time set in:
”Set door left open Alarm”
- OFF when door is closed
Output 2 (forced door alarm)
- ON if any door is open by force
- OFF when the door is closed
NOTE: If Door Sensors are not being used, the terminal
blocks Door Sensor1 and Door Sensor 2 should be
shorted with GND. By factory default, the controller will
be delivered with shorted Door sensors.
NOTE: Do not connect dierent Wiegand type of
readers. Both readers should be either Wiegand 26bit or
Wiegand 34bit.
1 2 3 4 5 6 7 8
ON
NOTE: Double wiegand is used for double security(Card + PIN Code). When LCSPEM/MF is connected and LCSPEM/-
MF is set in double security mode, put the dipswitch 1 or 2 to position ON.
NOTE: If Door sensors are not used, dipswitch No.3 should stay OFF.
NOTE: In 1 Door Mode, both readers are assigned to Door1. User Card can be programmed to trigger both relays,
which gives the option the second door relay to be used as alarm.
1 2 3 4 5 6 7 8
ON Double
Wiegand
on Reader 1
Double
Wiegand
on Reader 2
APB
follow
sensor ON
Anti Pass
Back option
ON
Enroll
Master Card
ON
Factory
Reset
ON
2 DOOR
Mode Not used
OFF Single
Wiegand
on Reader 1
Single
Wiegand
on Reader 2
APB
follow
sensor OFF
Anti Pass
Back option
OFF
Enroll
Master Card
OFF
Factory
Reset
OFF
1 DOOR
Mode Not used

www.xprgroup.com 4
6. WIRING
6.1 WIRING KEPADS LCSP, VKP, INOX, MTPADM
7. FACTORY RESET
1. Turn OFF the power Supply -
2. Put DIP Switch 6 in position ON -
3. Turn ON the power supply - Green LED - ON, Red LED - blinking
(wait for the Red LED to go OFF)
4. Put DIP Switch 6 in position OFF - Green LED - OFF, Red LED - blinking and goes OFF

www.xprgroup.com 5
8. PROGRAMMING
IMPORTANT:
Connect Proximity Reader(Wiegand26 or Wiegand34) to READER 1 Input, including its free tension
LED’s.The Reader’s Free tension LED’s are used for visual indication during the programming process.
Insert Master cards
Enroll a User
1. Turn OFF the power supply
2. Push the dip switch no.5 in position ON
3. Turn ON the power supply - Red LED - ON
4. On Reader1, present the master cards in this order: Master1&2, Delete, Reset APB, Master1, Master2
Note: For the irst inserted card, the green led will blink once, for the second, the green led will blink twice...etc
System can work without all master cards inserted (ex. Only Master, Delete and APB can be active).
Minimum master cards are two (Master1&2 and Delete)
5. Put the dip switch in position OFF (SC24000 will return to operational mode)
1. Present Master Card - Green LED - ON, Red LED - ON
2. Present Shadow Card - Green LED - ON, Red LED - OFF
3. Present User Card - Green LED - blinks twice on each user card
(or multiple User cards)
4. Present Master Card - Green LED - OFF, Red LED - OFF
Note: If the user is enrolled using MASTER1 card, the same user will have access only on DOOR1.
If the user is enrolled using MASTER2 card, the same user will have access only on DOOR2.
If the user is enrolled using Master1&2 card, the same user will have access on DOOR1 and DOOR2.
DELETE Card
217 40278
MASTER1&2 Card
204 27141
Reset APB Card
205 49142
Master1 Card
224 33143
Master2 Card
101 00147
Mark the master cards with the stickers provided in the kit
NOTE: Changing Master and Delete Card is done with the same procedure. Old Master/Delete Cards are deleted automatically.
NOTE: Shadow card can be issued for 1 user or for group of users. In both cases, write the name of the user on the shadow
card and keep all of the shadow cards on safe place.
NOTE: If more than one user is associated to same shadow card, deleting with that shadow card will result with deletion of all
the Users associated to that shadow card.
NOTE: If a shadow card needs to be changed, just enroll the same User with dierent Shadow card.
204 27142
130 22349
User Card 1
130 22348
130 22347
User Card 2
User Card 3
130 22346
Shadow
Card 1
130 22345
130 22344
Shadow
Card 2
Shadow
Card 3
130 22349
User Card 1
130 22348
130 22347
User Card 2
User Card 3
233 26735
Group
Shadow
Card
OR

www.xprgroup.com 6
Enroll Sequential Block of Cards
Delete a User with its shadow card
Delete a User with user card
Delete ALL Users
Delete ALL Users assigned to DOOR1
Delete ALL Users assigned to DOOR2
Reset All APB statuses
1. Present Master1 Card - Green LED- ON, Red LED - ON
2. Present Shadow Card - Green LED - ON, Red LED - OFF
3. Present the beginning card of the block 3 times - Green LED - blinks twice
4. Present the ending card of the block 3 times - Green LED - blinks twice
5. Present Master1 Card - Green LED - OFF, Red LED - OFF
1. Present Delete Card - Green LED - ON, Red LED - ON
2. Present Shadow Card - Green LED-blinks twice, Red LED - ON
(or multiple shadow cards)
3. Present Delete Card - Green LED - OFF, Red LED - OFF
1. Present Delete Card - Green LED - ON, Red LED - ON
2. Present User Card - Green LED - blinks twice, Red LED - ON
(or multiple user cards)
3. Present Delete Card - Green LED - OFF, Red LED - OFF
1. Present Delete Card - Green LED - ON, Red LED - ON
2. Present Master 1&2 Card 3 times - Green LED - ON, Red LED - ON, Orange LED blinks once
3. Present Delete Card - Green LED - OFF, Red LED - OFF
1. Present Delete Card - Green LED - ON, Red LED - ON
2. Present Master 1 Card 3 times - Green LED - ON, Red LED - ON, Orange LED blinks once
3. Present Delete Card - Green LED - OFF, Red LED - OFF
1. Present Delete Card - Green LED - ON, Red LED - ON
2. Present Master 2 Card 3 times - Green LED - ON, Red LED - ON, Orange LED blinks once - Green
3. Present Delete Card - Green LED - OFF, Red LED - OFF
1. Present Reset APB card on any reader
Enroll a Block of 100 sequential cards assigned to Door1: Note:
There is no sequence of numbering
Mifare cards.
Note:
Before enrolling block of cards,
make sure that the numbers are in
sequence and that sequence is
smaller than 100.
Note: By deleting a shadow card, all the Users associated to that shadow card will be deleted.

www.xprgroup.com 7
Set Door1 Open Time
Set Door2 Open Time
Set Door1 in Toggle (ON/OFF) Mode
Set Door2 in Toggle (ON/OFF) Mode
Set door left open Alarm
1. Present Master 1 Card 3 times - Green LED - OFF, Red LED - ON
2. Present Delete Card - Green LED - blinks twice, Red LED - ON
Present the card X times for X seconds
(Door open Time)
3. Present Master 1 Card - Green LED - OFF, Red LED - OFF
1. Present Master 2 Card 3 times - Green LED - OFF, Red LED - ON
2. Present Delete Card - Green LED - blinks twice, Red LED - ON
Present the card X times for X seconds
(Door open Time)
3. Present Master 2 Card - Green LED - OFF, Red LED - OFF
1. Present Master 1 Card 3 times - Green LED - OFF, Red LED - ON
2. Present Master 1 Card - Green LED - OFF, Red LED - OFF
1. Present Master 2 Card 3 times - Green LED - OFF, Red LED - ON
2. Present Master 2 Card - Green LED - OFF, Red LED - OFF
To set 40 seconds for door left open time:
1. Present Master1&2 Card 3 times - Green LED - OFF, Red LED - ON
2. Present Delete Card 4 times - Green LED - blinks twice, Red LED - ON
(4 x 10 sec. = 40 sec.)
3. Present Master1&2 Card - Green LED - OFF, Red LED - OFF
To disable the alarm:
Present Master1&2 Card 3 times - Red LED - ON
Present Master1&2 Card - Red LED - OFF
9. ANTI PASS BACK
If Door sensors are not being used at the installation, keep the dipswitch No.3 to position OFF. In this case, the APB
Status shall be determined by a card punch (was the card presented or not).
If Door sensors are used, then dipswitch. No3 should be in position ON. In this case, the APB status is determined by
the door status (was the door open or not).
To enable the Anti Pass Back option simply put the dipswitch no.4 to position ON.
DipSwitch No.4 - ON
1 2 3 4 5 6 7 8
ON

www.xprgroup.com 8
10. EXAMPLES
11. PROGRAMMING WITH KEYPADLCSP, VKP, INOX,MTPADM
Task1:
Task2:
Task3:
Make 1 Door installation with 1 Reader. Enroll 2 users to open the door.
Make 1 Door installation with IN and OUT Reader. Enroll User1 with access to Door1 in Anti Pass Back Mode and additional
User2 that will not have access to Door1, but will be able to turn the lights in the oice ON/OFF.
Make 2 Door installation. Enroll User 1 to open only DOOR1 and User 2 to open DOOR2 and User3 to open Door1 and Door2.
DIP switch settings: all are OFF
1. Present Master1 Card
2. Present Shadow Card
3. Present User Card 1
4. Present User Card 2
4. Present Master1 Card
DIP switch settings:
No.4ON, all other are OFF
DIP switch settings:
7 - ON; all others OFF
Relay connection:
Door relay1 - Door Lock; Door Relay 2 - Lights Main Switch
Relay connection:
Door relay1 - Door Lock; Door Relay 2 - Door Lock
1. Present Master1 Card
2. Present Shadow Card 1
3. Present User Card 1
4. Present Master1 Card
1. Present Master1 Card
2. Present Shadow Card 1
3. Present User Card 1
4. Present Master1 Card
1. Present Master2 Card
2. Present Shadow Card 2
3. Present User Card 2
4. Present Master2 Card
1. Present Master2 Card
2. Present Shadow Card 2
3. Present User Card 2
4. Present Master2 Card
1. Present Master 2 Card 3 times
2. Present Master 2 Card
1. Present Master1&2 Card
2. Present Shadow Card 3
3. Present User Card 3
4. Present Master1&2 Card
User1 with Access to Door1
User1 with Access to Door1
User2 to be able to activate
Door Relay2 (Lights), but not
Door Relay 1.
User2 with Access to Door2
Make Door relay 2 to work in ON/OFF Mode
User3 with Access to Door1 and Door2
The programming with Keypad is same as programming with proximity reader.
Please refer to programming explained on pages 4 to 7, just replace the word “Card” with “PIN Code”
Keypad settings
Set the keypad to be compatible with SC24000 Standalone Controller
Press B+000000 to enter the menu
Press 6
Press 1
Press Ato exit the menu
This will set the Keypad in “Wiegand26 bit Normal”, “4 Digits PIN Code” and “Card or PIN Code” mode(LCSP).
For other settings (like changing PIN Code length), please refer to the keypad’s manual.

www.xprgroup.com 9
12. PROGRAMMING IN DOUBLE SECURITY MODELCSP
Insert Master cards
1. Turn OFF the power supply
2. Push the dip switch no.5 in position ON
3. Turn ON the power supply - Red LED - ON
4. On Reader1, present the master cards in this order:
Master1&2 + ANY 4 digit Code
Delete + ANY 4 digit Code
Reset APB + ANY 4 digit Code
Master1 + ANY 4 digit Code
Master2 + ANY 4 digit Code
Note: For the irst inserted card, the green led will blink once, for the second, the green led will blink twice...etc
System can work without all master cards inserted (ex. Only Master, Delete and APB can be active).
Minimum master cards are two (Master1&2 and Delete)
5. Put the dip switch in position OFF (SC24000 will return to operational mode)
Double Security Mode is possible only with double technology readers (proximity + keypad, LCSP)
1. If LCSP is connected to Reader1 Input put the dipswitch1 to position ON
If LCSP is connected to Reader2 Input put the dipswitch2 to position ON
2. Set the keypad to double security mode
Press B+000000 to enter the menu
P ress 6
Press 4
Press 5
Press 3
Press Ato exit the menu
This will set the Keypad in “Wiegand26 bit Double”, “4 Digits PIN Code” and “Card and PIN Code” mode.
DELETE Card
217 40278
MASTER1&2 Card
204 27141
Reset APB Card
205 49142
Master1 Card
224 33143
Master2 Card
101 00147
Mark the master cards with the stickers provided in the kit
NOTE: Changing Master and Delete Card is done with the same procedure. Old Master/Delete Cards are deleted automatically.
1 2 3 4 5 6 7 8
ON

www.xprgroup.com 10
Enroll a User
Delete a User with its shadow card
Delete a User with user card
1. Present Master Card + ANY 4 digit Code - Green LED - ON, Red LED - ON
2. Present Shadow Card + ANY 4 digit Code - Green LED - ON, Red LED - OFF
3. Present User Card + ANY 4 digit Code - Green LED - blinks twice on each user card
(or multiple User cards + ANY 4 digit Code)
4. Present Master Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
Note: If the user is enrolled using MASTER1 card, the same user will have access only on DOOR1.
If the user is enrolled using MASTER2 card, the same user will have access only on DOOR2.
If the user is enrolled using MASTER1&2 card, the same user will have access on DOOR1 and DOOR2.
1. Present Delete Card + ANY 4 digit Code - Green LED - ON, Red LED - ON
2. Present Shadow Card + ANY 4 digit Code - Green LED - blinks twice, Red LED - ON
(or multiple shadow cards)
3. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
Note: By deleting a shadow card, all the Users associated to that shadow card will be deleted.
1. Present Delete Card + ANY 4 digit Code - Green LED - ON, Red LED - ON
2. Present User Card + ANY 4 digit Code - Green LED - blinks twice, Red LED - ON
(or multiple user cards)
3. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
IMPORTANT:
With the procedure above, ONLY the Card is stored. To store the PIN Code, present the newly enrolled Card
(the Orange LED will start blinking) and type the desired PIN code.
In other words, after exiting the programming, the irst time the card is punched, the irst PIN Code typed
becomes the Pin Code assigned to that card only.
This feature can prevent the installer to know the PIN Code of the user. The user can choose his own PIN Code.
NOTE: Shadow card can be issued for 1 user or for group of users. In both cases, write the name of the user on the shadow
card and keep all of the shadow cards on safe place.
NOTE: If more than one user is associated to same shadow card, deleting with that shadow card will result with deletion of all
the Users associated to that shadow card.
NOTE: If a shadow card needs to be changed, just enroll the same User with dierent Shadow card.
204 27142
130 22349
User Card 1
130 22348
130 22347
User Card 2
User Card 3
130 22346
Shadow
Card 1
130 22345
130 22344
Shadow
Card 2
Shadow
Card 3
130 22349
User Card 1
130 22348
130 22347
User Card 2
User Card 3
233 26735
Group
Shadow
Card
OR

www.xprgroup.com 11
Delete ALL Users
Delete ALL Users assigned to DOOR1
Delete ALL Users assigned to DOOR2
Set Door1 in Toggle (ON/OFF) Mode
Set Door2 in Toggle (ON/OFF) Mode
Reset All APB statuses
Set Door1 Open Time
Set Door2 Open Time
1. Present Delete Card + ANY 4 digit Code - Green LED - ON, Red LED - ON
2. Present Master 1&2 Card + ANY 4 digit Code 3 times - Green LED - ON, Red LED - ON, Orange LED blinks once
3. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
1. Present Delete Card + ANY 4 digit Code - Green LED - ON, Red LED - ON
2. Present Master 1 Card + ANY 4 digit Code 3 times - Green LED - ON, Red LED - ON, Orange LED blinks once
3. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
1. Present Delete Card + ANY 4 digit Code - Green LED - ON, Red LED - ON
2. Present Master 2 Card + ANY 4 digit Code 3 times - Green LED - ON, Red LED - ON, Orange LED blinks once
3. Present Delete Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
1. Present Master 1 Card + ANY 4 digit Code 3 times - Green LED - OFF, Red LED - ON
2. Present Master 1 Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
1. Present Master 2 Card + ANY 4 digit Code 3 times - Green LED - OFF, Red LED - ON
2. Present Master 2 Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
1. Present Reset APB card + ANY 4 digit Code on any reader
1. Present Master 1 Card + ANY 4 digit Code 3 times - Green LED - OFF, Red LED - ON
2. Present Delete Card + ANY 4 digit Code - Green LED - blinks twice, Red LED - ON
Present the card X times for X seconds
(Door open Time)
3. Present Master 1 Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
1. Present Master 2 Card + ANY 4 digit Code 3 times - Green LED - OFF, Red LED - ON
2. Present Delete Card + ANY 4 digit Code - Green LED - blinks twice, Red LED - ON
Present the card X times for X seconds
(Door open Time)
3. Present Master 2 Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF

www.xprgroup.com 12
Set door left open Alarm
To set 40 seconds for door left open time:
1. Present Master1&2 Card + ANY 4 digit Code 3 times - Green LED - OFF, Red LED - ON
2. Present Delete Card + ANY 4 digit Code 4 times - Green LED - blinks twice, Red LED - ON
(4 x 10 sec. = 40 sec.)
3. Present Master1&2 Card + ANY 4 digit Code - Green LED - OFF, Red LED - OFF
To disable the alarm:
Present Master1&2 Card + ANY 4 digit Code 3 times - Red LED - ON
Present Master1&2 Card + ANY 4 digit Code - Red LED - OFF
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS2 directive EN50581:2012
Table of contents
Other XPR Access Control Unit manuals